Search NASA⌕ Search

SEARCH · Search NASA

Results for “MICROPHONE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Nonlinear Signal Processing for Removing Microphonic Noise from Nuclear Spectrometer Measurements: Sparse Linear Modeling via L1 Norm Regularization [Slides]

The focus of this initial work is to apply recent breakthroughs in sparse linear modeling and nonlinear signal processing to the problem of removing microphonic noise from nuclear spectrum measurements. The resolution of nuclear spectrum measurements is commonly degraded by microphonic noise caused by the vibration of supporting equipment (i.e. cryocoolers) as well as motion of the detector itself in mobile applications. Current signal processing techniques cannot remove microphonic noise without modifying the desired characteristics of the spikes induced by nuclear detection events. The LANL Engineering Institute has been working with NEN‐1 to remedy this problem. Initial work focused on developing active control systems to cancel the vibrations experienced by nuclear detectors. As work on progressed along these lines the team realized that a more robust, lower‐energy, lower‐cost solution to the microphonic noise problem could be realized using recent breakthroughs in nonlinear signal processing. Over the course of the last decade significant advances have been made in the field of sparse linear modeling using L1 norm minimization to find linear representations of sparse signals. The problem of removing microphonic noise from nuclear detection measurements appears to be well suited to the L1 minimization approach because these measurements tend to be inherently sparse in two different domains. The nuclear detections are sparse in a spike domain, and the microphonic noise is sparse in the Fourier basis. L1 minimization allows us to decompose the measurements into these two domains. The result is that we can potentially separate the spikes from the microphonic noise. Initial investigations into this technique look very promising. In this work microphonic noise is induced in an HE‐3 detector by a wrench impact. A pulser is used to generate uniform, synthetic, nuclear events and is fed into the detector front end electronics. Nearly all the microphonic noise is separated from the spike measurements. The histograms in Figure 2 illustrate that spectrum widening caused by noise is significantly reduced. The goal of future work to further develop this technique to account for variations in spike characteristics, as well as to use adaptive signal processing and modern Graphical Processing Unit (GPU) technology to speed up the signal decompositions.

42 ENGINEERING↗

Characterization of condenser microphones under different environmental conditions for accurate speed of sound measurements with acoustic resonators

Condenser microphones are more commonly used and have been extensively modeled and characterized in air at ambient temperature and static pressure. However, several applications of interest for metrology and physical acoustics require to use these transducers in significantly different environmental conditions. Particularly, the extremely accurate determination of the speed of sound in monoatomic gases, which is pursued for a determination of the Boltzmann constant k by an acoustic method, entails the use of condenser microphones mounted within a spherical cavity, over a wide range of static pressures, at the temperature of the triple point of water (273.16 K). To further increase the accuracy achievable in this application, the microphone frequency response and its acoustic input impedance need to be precisely determined over the same static pressure and temperature range. Few previous works examined the influence of static pressure, temperature, and gas composition on the microphone's sensitivity. In this work, the results of relative calibrations of 1/4 in. condenser microphones obtained using an electrostatic actuator technique are presented. The calibrations are performed in pure helium and argon gas at temperatures near 273 K and in the pressure range between 10 and 600 kPa. These experimental results are compared with the predictions of a realistic model available in the literature, finding a remarkable good agreement. The model provides an estimate of the acoustic impedance of 1/4 in. condenser microphones as a function of frequency and static pressure and is used to calculate the corresponding frequency perturbations induced on the normal modes of a spherical cavity when this is filled with helium or argon gas.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A method for estimating the amplitude response of smartphone built-in microphone sensors below 4 kHz

A method for estimating the amplitude response of built-in smartphone microphone sensors is pre- sented. The method is intended to be accessible to the general public, and comparison calibration measurements are performed in a non-isolated environment using conventional consumer products. A double reference sensor scheme is set up, consisting of a MB3 digital microbarometer (reference over the 0.5–2 Hz octave bands) and the iPrecisionMic smartphone microphone (reference above the 2 Hz octave band). The amplitude response of the iPrecisionMic sensor is first evaluated over the 1–2000 Hz octave bands. The amplitude response of three Samsung Galaxy S8 built-in smart- phone microphone sensors is then measured over the 0.5–2000 Hz octave bands. The Redvox Infrasound Recorder application (app) for Android is used to measure acoustic signals with the built-in smartphone microphone sensors. Amplitude response models in terms of digital gain are estimated for the test sensors based on the results. Last, self-noise levels for the iPrecisionMic and Samsung Galaxy S8 microphones are estimated and compared to infrasound ambient noise models. Results show an experimental capability for estimating the amplitude response of built-in smartphone microphone sensors in a non-isolated environment with conventional consumer products.

47 OTHER INSTRUMENTATION↗

Laser-induced breakdown spectroscopy acoustic testing of the Mars 2020 microphone

Here, the SuperCam instrument suite onboard the Mars 2020 rover will include the Mars Microphone, an experiment designed to record the sounds of the SuperCam laser strikes on rocks and also aeolian noise. In order to record shock waves produced by the laser blasts, the Mars Microphone must be able to record audio signals from 100 Hz to 10 kHz on the surface of Mars, with a sensitivity sufficient to monitor a laser impact at distances up to 4 m. We have used the Aarhus planetary simulator facility to test the Mars 2020 rover microphone in a controlled Martian environment. The end-to-end tests performed in a 6 mbar CO 2 atmosphere, with wind, and also with the microphone at –80°C have demonstrated that the SuperCam/Mars Microphone requirements are satisfied. Tests were also performed on Martian soil simulant targets showing that the variation of the acoustic energy of the shock wave depends on the level of compaction of the target.

47 OTHER INSTRUMENTATION↗

A new microphonics measurement method for superconducting RF cavities

Mechanical vibrations of the superconducting cavity, also known as microphonics, cause shifts in the resonant frequency of the cavity. In addition to requiring additional RF power, these frequency shifts can contribute to errors in the closed loop phase and amplitude regulation. In order to better understand these effects, a new microphonics measurement method was developed, and the method was successfully used to measure microphonics on the half-wave superconducting cavity when it was operated in a production style cryostat. The test cryostat held a single β=0.1 half-wave cavity which was operated at 162.5 MHz [1] and [2]. It's the first time that the National Instruments PXIe-5641R intermediate frequency transceiver has been used for microphonics measurements in superconducting cavities. The new microphonics measurement method and results will be shown and analyzed in this paper.

Gao, Zheng↗

Development of an MEMS ultrasonic microphone array system and its application to compressed wavefield imaging of concrete

Abstract Although contactless ultrasonic wavefield imaging shows potential for effective nondestructive inspection of various engineering materials, it has been rarely applied to concrete materials owing to technical challenges including low signal-to-noise ratio (SNR) caused by inherent heterogeneity of concrete. This paper presents development of a multi-channel MEMS ultrasonic microphone array system and its application to compressed wavefield imaging of concrete materials. The developed multi-channel MEMS ultrasonic microphone array system contains eight MEMS ultrasonic microphone elements and a signal conditioning circuit that enables measurements of ultrasonic signals with high SNR. A compressed sensing approach, based on the multiple measurement vector (MMV) concept, is applied to reconstruct a full dense ultrasonic wavefield data from sparsely sampled ultrasonic wavefield data. Experiments are carried out on a laboratory concrete sample to verify the performance of the developed MEMS microphone array system and proposed compressed sensing approach and then large-scale concrete samples to demonstrate practical application. The experimental results demonstrate that the developed MEMS microphone array system provides high-quality (SNR > 20 dB) ultrasonic data collected from concrete elements; furthermore, the proposed compressed sensing approach provides accurate reconstruction of dense wavefield data, as determined by peak signal-to-noise ratio (PSNR), from sparsely measured wavefield data with compression ratios up to 85% and PSNR above 25 dB in data collected form realistic large-scale concrete samples. By combining the MEMS array system and compressed sensing approach, the total ultrasonic data acquisition time needed to produce dense wavefield data can be significantly reduced.

Instruments & Instrumentation↗

Microphonics in the LCLS-II Superconducting Linac

The LCLS-II project has installed a new superconducting linac at SLAC that consists of 35 1.3 GHz cryomodules and 2 3.9 GHz cryomodules. The linac will provide a 4 GeV electron beam for generating soft and hard X-ray pulses. Cavity detuning induced by microphonics was a significant design challenge for the LCLS-II cryomodules. Cryomodules were produced that were within the detuning specification (10 Hz for 1.3 GHz cryomodules) on test stands. Here we present first measurements of the microphonics in the installed LCLS-II superconducting linac. Overall, the microphonics in the linac are manageable with 94% of cavities coming within the detune specification. Only two cavities are gradient limited due to microphonics. We identify a leaking cool down valve as the source of microphonics limiting those two cavities.

43 PARTICLE ACCELERATORS↗

Analysis of Electronic Damping of Microphonics in Superconducting Cavities

In low current applications superconducting cavities have a high susceptibility to microphonics induced by external vibrations and pressure fluctuations. Due to the narrow bandwidth of the cavities, the amount of rf power required to stabilize the phase and amplitude of the cavity field is dictated by the amount of microphonics that need to be compensated. Electronic damping of microphonics is investigated as a method to reduce the level of microphonics and of the amount of rf power required. The current work presents a detailed analysis of electronic damping and of the residual cavity field amplitude and phase errors due to the fluctuations of cavity frequency and beam current.

Delayen, Jean↗

Eliminating flow-induced microphonics in a superfluid helium cryogenic system

Superconducting radio frequency cavities are the devices of choice when it comes to accelerating charged particle beams in modern particle accelerators. They are held in a bath of liquid helium, to maintain their operating temperature at 2.0 K. The dimensions of these cavities are controlled within microns to facilitate operation at design conditions. During operation however, these cavities experience microphonic disturbances i.e., small mechanical deformations, that cause an undesired response in the electrical performance of the cavity. This paper proposes solutions to mitigate microphonics caused by fluid flow, particularly by the fill line into the helium bath in a 2.0 K cryogenic system. Specifically, three different systems designs are proposed, two of which dramatically reduce vapor generation and thereby its contribution to microphonics. The third design is found to completely suppress vapor generation and is explored in further detail.

09 BIOMASS FUELS↗

A comparison of smartphone and infrasound microphone data from a fuel air explosive and a high explosive

For prompt detection of large (>1 kt) above-ground explosions, infrasound microphone networks and arrays are deployed at surveyed locations across the world. Denser regional and local networks are deployed for smaller explosions, however, they are limited in number and are often deployed temporarily for experiments. With the expanded interest in smaller yield explosions targeted at vulnerable areas such as population centers and key infrastructures, the need for more dense microphone networks has increased. An “attritable” (affordable, reusable, and replaceable) and flexible alternative can be provided by smartphone networks. Explosion signals from a fuel air explosive (thermobaric bomb) and a high explosive with trinitrotoluene equivalent yields of 6.35 and 3.63 kg, respectively, were captured on both an infrasound microphone and a network of smartphones. The resulting waveforms were compared in time, frequency, and time-frequency domains. The acoustic waveforms collected on smartphones produced a filtered explosion pulse due to the smartphone's diminishing frequency response at infrasound frequencies (<20 Hz) and was found difficult to be used with explosion characterization methods utilizing waveform features (peak overpressure, impulse, etc.). However, the similarities in time frequency representations and additional sensor inputs are promising for other explosion signal identification and analysis. As an example, a method utilizing the relative acoustic amplitudes for source localization using the smartphone sensor network is presented.

47 OTHER INSTRUMENTATION↗

MICROPHONICS TESTING OF LCLS II CRYOMODULES AT JLAB

Jefferson Lab is partnering with Fermilab to build 40 cryomodules for the LCLS II accelerator that will be installed at the Stanford Linear Accelerator (SLAC). The LCLS II cryomodule is an 8-seat CW cryomodule which operates at 1300 MHz and is based on the XFEL design. The cavities have design loaded-Q of 4×107, which means that it has a control bandwidth of 16 Hz. The JLab prototype cryomodule was instrumented with a series of 10 accelerometers, and impulse hammer response measurements were made while the cryomodule was being built and after it was installed in the JLAB cryomodule test facility. This was done so that we could better understand the shapes of the modes of the structure. These results were compared to impulse hammer testing from the outside of the cryomodule to individual cavity frequency shifts when the cryomodule was cold. Additionally, background microphonics and transfer function measurements were made on several other LCLS II cryomodules in the JLab cryomodule test facility (CMTF). The prototype cryomodule had excessive microphonics up to 100 Hz peak due to a thermo-acoustic oscillation in the cryogenic supply circuit. Design modifications were implemented and subsequently the cryomodules had microphonics on the order of 10 to 20 Hz.

Powers, Thomas↗

Noise Reduction with Microphone Arrays for Speaker Identification

Reducing acoustic noise in audio recordings is an ongoing problem that plagues many applications. This noise is hard to reduce because of interfering sources and non-stationary behavior of the overall background noise. Many single channel noise reduction algorithms exist but are limited in that the more the noise is reduced; the more the signal of interest is distorted due to the fact that the signal and noise overlap in frequency. Specifically acoustic background noise causes problems in the area of speaker identification. Recording a speaker in the presence of acoustic noise ultimately limits the performance and confidence of speaker identification algorithms. In situations where it is impossible to control the environment where the speech sample is taken, noise reduction filtering algorithms need to be developed to clean the recorded speech of background noise. Because single channel noise reduction algorithms would distort the speech signal, the overall challenge of this project was to see if spatial information provided by microphone arrays could be exploited to aid in speaker identification. The goals are: (1) Test the feasibility of using microphone arrays to reduce background noise in speech recordings; (2) Characterize and compare different multichannel noise reduction algorithms; (3) Provide recommendations for using these multichannel algorithms; and (4) Ultimately answer the question - Can the use of microphone arrays aid in speaker identification?

42 ENGINEERING↗

Analysis and Management of Microphonics in Operational SRF Cavities With Bandwidths of approximately 10 Hz

Superconducting Radio Frequency Cavity detuning can be due to several effects. These effects include helium pressure variations, vibrations driven by external narrow band sources such as HVAC motors, cooling water systems, tuner motor operation, cryogenic system machinery, and occasionally cryogenic system instabilities such as thermo-acoustic oscillations. They can also be driven by broadband white or pink noise which, in general, will excite the resonant modes of the structure. All of these affect the cavity resonant frequency. Variations that occur at frequencies above a few tenths of a Hertz are considered microphonics. CEBAF 0.7 m C100 cavities operated at 1500 MHz with 20 Hz bandwidths, changes in cavity lengths on the order of 10 nm are sufficient to shift the cavity frequency by more than one bandwidth. Jefferson Lab is the first lab to install and operate a large number of SRF cavities with relatively high loaded-Qs, 88 in CEBAF and 16 in the LERF (previously the FEL). Production was halted for several months after the first 3 production C100 cryomodules were built, and modifications were developed in order to reduce the background microphonics. Additionally, in the spring of 2016 we started a program to harden and damp the cryomodule interface structures in order to reduce the sensitivity to outside perturbations as well as to damp out the natural vibrational modes of the structures. This work will focus on the approaches and measurements that one should consider when designing a system in order to understand the modal nature of the structure, the measurement techniques for determining the extent of the microphonics, and the mitigations that can be implemented in order to reduce the effects of outside perturbances. Examples of results at various other institutions will also be presented.

Powers, Thomas↗

Active microphonic noise cancellation in radiation detectors

A new adaptive filtering technique to reduce microphonic noise in radiation detectors is presented. The technique is based on system identification that actively cancels the microphonic noise. A sensor is used to measures mechanical disturbances that cause vibration on the detector assembly, and the digital adaptive filtering estimates the impact of these disturbances on the microphonic noise. The noise then can be subtracted from the actual detector measurement. In this paper the technique is presented and simulations are used to support this approach.

47 OTHER INSTRUMENTATION↗

Predicting chatter using machine learning and acoustic signals from low-cost microphones

Machining chatter is a phenomenon resulting from self-oscillation between a machining tool and workpiece. This self-oscillation results in variation on the machined product that reduces the ability to meet desired specifications. Chatter is a widely studied topic as it directly relates to the quality of machined products. Here, this study details the application of a Random Forest (RF) classifier with Recursive Feature Elimination (RFE) to machining audio collected by a single microphone during down-milling operations. This approach allows straightforward feature elimination that results in an easily understood set of analyzed dimensions. Stability is predicted solely based on the classification output of the RF classifier. Our approach proves highly predictive with consistent machining setup and a small sample set. We also review transferability between machining setups and present key findings. Our RF approach demonstrates the ability to analyze and classify chatter through a low-cost approach with limited training data required. The motivation for using a single microphone is to enable detection on machines without other sensors, such as accelerometers, present in the machining setup. The value of the in-process sensor and chatter classifier is highlighted because the machining setup included asymmetric dynamics that reduced the accuracy of the traditional analytical stability solution. We see a natural progression to deploying this audio-only methodology with real-time processing and classification using either a laptop or smartphone. This progression will allow visual indicators during the machining process that can alert machinists of progression into unstable machining processes.

42 ENGINEERING↗

Control of microphonics for a superconducting radio-frequency photo-injector cryomodule

A superconducting radio-frequency photo-injector cryomodule is being developed for the high-energy upgrade of the Linac Coherent Light Source (LCLS-II-HE). This effort is a collaboration between the Facility for Rare Isotope Beams at Michigan State University (MSU), Argonne National Laboratory, Helmholtz-Zentrum Dresden-Rossendorf, and SLAC National Accelerator Laboratory. The cryomodule features a 185.7 MHz superconducting quarter-wave resonator (QWR) designed to operate with an RF electric field of 30 MV/m at the photo-cathode. Mechanical vibrations must be controlled for operation with stable amplitude and phase. The first prototype cryomodule was cold-tested at MSU with a QWR, fundamental power coupler, tuner, and cathode stalk. In the cold test, we observed microphonics that made it difficult to control the RF phase at high gradient. The cryogenic circuit was identified as a likely culprit. This paper presents our studies of microphonics during the cryomodule cold test and follow-up investigations at room temperature. Our findings provided valuable feedback for modifications to the cryogenic circuit and a successful second cold test of the cryomodule.

Accelerator Physics↗

Active Microphonics Compensation for LCLS-II

Testing of early LCLS-II cryomodules showed microphonics-induced detuning levels well above specification. As part of a risk-mitigation effort, a collaboration was formed between SLAC, LBNL, and Fermilab to develop and implement active microphonics compensation into the LCLS-II LLRF system. Compensation was first demonstrated using a Fermilab FPGA-based development system compensating on single cavities, then with the LCLS-II LLRF system on single and multiple cavities simultaneously. The primary technique used for this effort is a bank of narrowband filter set using the piezo-to-detuning transfer function. Compensation automation, optimization, and stability studies were done. Details of the techniques used, firmware/software implementation, and results of these studies will be presented.

43 PARTICLE ACCELERATORS↗