Search NASA⌕ Search

SEARCH · Search NASA

Results for “MICROTRONS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

I. Final Report for DOE SBIR Phase I Project DE-SC0013795 Final Report for DOE SBIR Phase I Project DE-SC0013795 Microtron-based Compact, Portable Gamma-Ray Source

Microtron-based Compact, Portable Gamma-Ray Source. The objective of Phase I of this project was to produce a conceptual design of a prototype compact microtron electron accelerator, which could be designed, built, and demonstrated in Phase II of the project. The conceptual design study included an analysis of the parameters of the microtron and its components, and the expected performance of the prototype microtron as a source of x-rays and/or RF neutrons in the MeV energy range. The major components of the microtron are the magnet, the accelerating system, the power system, the vacuum system, the control system, the beam extraction system and the targets to produce x-rays (and/or neutrons). Our objectives for the design of the prototype were for it to be compact, cost-effective, capable of producing high intensity x-ray (an/or neutron) fluxes. In addition, the prototype was to be easily assembled and disassembled so that components could be easily replaced. The main parameters for the prototype are the following: the range of electron kinetic energies, the output power, the RF frequency band (X-band, C-band, or S-Band), the type of injection (Type I or Type II), the magnet type, i.e. permanent magnet, electromagnet, or a hybrid combination of permanent and electromagnet. The results of the Phase I study and analysis for a prototype microtron are the following: The electron energy range can be varied from below 6 MeV to 9 MeV, the optimal frequency range is S-Band (2-4 GHz) RF frequency, Type II injection (described below), and the magnet type is the hybrid version. The prototype version will be capable of producing gamma ray doses of ~1800 R/min-m and neutron fluxes of up to ~6 x 10 10 n/s with appropriate targets. The results of the Phase I study and analysis are provided below. The proposed Phase II plan was to demonstrate the prototype at low beam power. In the subsequent Phase III, high power tests would be performed, and the design of commercial versions of microtrons with various energies, sizes and types would be produced and marketed, including a more compact and more portable 6 MeV battery-powered model that more closely meets the requirements in the original FOA topic description. In the course of the Phase I study, we also identified another microtron version, one that was larger (not compact) and more powerful than that of the Phase II prototype, which could serve as an intense source of photo- neutrons, up to 4 x 10 12 n/s for use in nuclear medicine, short-lived isotope production, or other applications. In addition, it could produce gamma dose rates up to 130 kR/min-m with a heavy metal bremsstrahlung target. The results and specifications of this were submitted to IPAC16 (Reference [12]) the paper is included in Addendum B. Because this version was beyond the scope of the Phase I project, there is no additional description in the Final Report.

43 PARTICLE ACCELERATORS↗

Phase stability of a microtron driving a terahertz FEL

The phase stability of bunches accelerated by a magnetron-driven microtron-injector of a terahertz Free Electron Laser (FEL) has been studied to optimize the microtron regimes providing good operation of the FEL. The study is based on a simulation of the beam dynamics in the microtron considering 2-D motion of the electrons in the median plane. This allows the computation of the current loading the accelerating cavity as well as the output microtron current. The loading current has been used to calculate the frequency deviations caused by the incremental loading in the accelerating cavity coupled with the magnetron. Further computations using the 2-D simulation show noticeable phase oscillation of the accelerated bunch leaving the microtron on the macro-pulse front. The phase oscillation is in agreement with the measured one and affects the lasing in the microtron-based FEL. Optimization of the microtron regimes allows one to minimize the effect. As a result, the terahertz microtron-based FEL provides radiated macro-pulse energy up to 0.2 mJ tunable in the range of 0.85-3 THz with good stability. Results of the simulation and the measurements are presented in this article.

43 PARTICLE ACCELERATORS↗

Microtron Data Log

The Microtron at Los Alamos National Laboratory (LANL) is a versatile electron accelerator originally designed for medical therapy. Since 2001, it has been used for non-destructive radiographic imaging and research and development applications. Operating at four different energy levels—6, 10, 15, and 20 MeV—the Microtron produces dose rates of approximately 780, 1800, 2700, and 2800 R/min at a distance of one meter from the source, respectively. This high-energy X-ray source enables detailed internal examination of dense and thick objects without causing damage, making it invaluable for various scientific and industrial applications. For instance, LANL’s Microtron has been utilized to study the performance of large-panel cerium-doped lutetium yttrium silicon oxide (LYSO) scintillators, which are essential components in advanced imaging systems.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Microtron MT 25 as a source of neutrons

The objective was to describe Microtron MT25 as a source of neutrons generated by bremsstrahlung induced photonuclear reactions in U and Pb targets. Bremsstrahlung photons were produced by electrons accelerated at energy 21.6 MeV. Spectral fluence of the generated neutrons was calculated with MCNPX code and then experimentally determined at two positions by means of a Bonner spheres spectrometer in which the detector of thermal neutrons was replaced by activation Mn tablets or track detectors CR-39 with a {sup 10}B radiator. The measured neutron spectral fluence and the calculated anisotropy served for the estimation of neutron yield from the targets and for the determination of ambient dose equivalent rate at the place of measurement. Microtron MT25 is intended as one of the sources for testing neutron sensitive devices which will be sent into the space.

43 PARTICLE ACCELERATORS↗

Tuning the operational parameters of the first microtron stage

The Laboratorio do Acelerador Linear is building a racetrack microtron electron accelerator. It has two acceleration stages: the booster and the main microtron. The aim of this work is to optimize the operation parameters of the booster stage by means of simulation tools. The accelerator admittances were determined successfuly and the results are presented. The injection beam has been characterized previously, and the available data were used to match the transverse beam emittances of the injector to the transverse beam admittances of the booster. Preliminary results showed that the simulations have a good agreement with the working parameters.

43 PARTICLE ACCELERATORS↗

The Microtron M-30: Current State and Research Program

The main characteristics of the Microtron M-30 accelerator are reviewed. Examples of its application to fundamental and applied researches carried out at the Institute of Electron Physics are described.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Microtron Modelling and Control

The article describes the design of the mathematical model and automatic control system of the microtron (high frequency cyclic electron accelerator). This type of accelerator was controlled manually till now. The critical values have been set up empirically on the basis of the previous operational experiences. The designed automatic control system with fuzzy controller should increase the accelerated electrons current value and improve the beam stability.

97 MATHEMATICS AND COMPUTING↗

Measurement of the {gamma}p{yields}{eta}p Reaction with the Crystal Ball Detector at the Mainz Microtron (MAMI-C)

The {gamma}p{yields}{eta}p reaction has been measured with the Crystal Ball and TAPS multiphoton spectrometers in the energy range from the production threshold to 1.4 GeV (1.49{<=}W{<=}1.87 GeV). Bremsstrahlung photons produced by the 1.5-GeV electron beam of the Mainz Microtron MAMI-C and momentum analyzed by the Glasgow Tagging Spectrometer were used for the {eta}-meson production. Our accumulation of 3.8x10{sup 6} {gamma}p{yields}{eta}p{yields}3{pi}{sup 0}p{yields}6{gamma}p events allows a detailed study of the reaction dynamics. The {gamma}p{yields}{eta}p differential cross sections were determined for 120 energy bins and the full range of the production angles. Our data show a dip near W = 1680 MeV in the total cross section related to a substantial dip in {eta} production at forward angles. The data are compared to predictions of previous SAID and MAID partial-wave analyses and to the latest SAID and MAID fits that included our data.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Searches for dark photons at the Mainz Microtron

The A1 Collaboration at the Mainz Microtron (MAMI) operates high resolution spectrometers at very high luminosities for fixed target electron scattering experiments. The setup is well suited for the search for dark photons in the mass range between 50 MeV and 300 MeV. In these experiments, a possible dark photon would appear as a sharp peak in the mass spectrum of di-lepton electro-production. In this presentation the potential of the setup is presented and the possibilities for future experiments for dark photon searches at MAMI are discussed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurement of the slope parameter {alpha} for the {eta}{yields}3{pi}{sup 0} decay with the Crystal Ball detector at the Mainz Microtron (MAMI-C)

The dynamics of the {eta}{yields}3{pi}{sup 0} decay have been studied with the Crystal Ball multiphoton spectrometer and the TAPS calorimeter. Bremsstrahlung photons produced by the 1.5-GeV electron beam of the Mainz microtron MAMI-C and tagged by the Glasgow photon spectrometer were used for {eta}-meson production. The analysis of 3x10{sup 6} {gamma}p{yields}{eta}p{yields}3{pi}{sup 0}p{yields}6{gamma}p events yields the value {alpha}=-0.032{+-}0.003 for the {eta}{yields}3{pi}{sup 0} slope parameter, which agrees with the majority of recent experimental results and has the smallest uncertainty. The {pi}{sup 0}{pi}{sup 0} invariant-mass spectrum was investigated for the occurrence of a cusplike structure in the vicinity of the {pi}{sup +}{pi}{sup -} threshold. The observed effect is small and does not affect our measured value for the slope parameter.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Experimental study of the {gamma}p{yields}{eta}p reaction with the Crystal Ball detector at the Mainz Microtron (MAMI-C)

The {gamma}p{yields}{eta}p reaction has been measured with the Crystal Ball and TAPS multiphoton spectrometers in the energy range from the production threshold of 707 MeV to 1.4 GeV (1.49{<=}W{<=}1.87 GeV). Bremsstrahlung photons produced by the 1.5-GeV electron beam of the Mainz Microtron MAMI-C and momentum analyzed by the Glasgow tagging spectrometer were used for the {eta}-meson production. Our accumulation of 3.8x10{sup 6} {gamma}p{yields}{eta}p{yields}3{pi}{sup 0}p{yields}6{gamma}p events allows a detailed study of the reaction dynamics. The {gamma}p{yields}{eta}p differential cross sections were determined for 120 energy bins and the full range of the production angles. Our data show a dip near W=1680 MeV in the total cross section caused by a substantial dip in {eta} production at forward angles. The data are compared to predictions of previous SAID and MAID partial-wave analyses and to the latest SAID and MAID fits that included our data.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurement of the π 0 → e + e - γ Dalitz decay at the Mainz Microtron

The Dalitz decay π 0 → e + e - γ has been measured in the γp → π 0 p reaction with the A2 tagged-photon facility at the Mainz Microtron, MAMI. The value obtained for the slope parameter of the π 0 electromagnetic transition form factor, a π = 0.030 ± 0.010 tot , is in agreement with existing measurements of this decay and with recent theoretical calculations. The uncertainty obtained in the value of a π is lower than in previous results based on the π 0 → e + e - γ decay.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurement of the ω → π 0 e + e - and η → e + e - γ Dalitz decays with the A2 setup at the Mainz Microtron

The Dalitz decays η → e + e - γ and ω → π 0 e + e - have been measured in the γp → ηp and γp → ωp reactions, respectively, with the A2 tagged-photon facility at the Mainz Microtron. The value obtained for the slope parameter of the electromagnetic transition form factor of η, Λ$-2\atop{η}$ = (1.97 ± 0.11 tot ) GeV -2 , is in good agreement with previous measurements of the η → e + e - γ and η → μ + μ - γ decays. The uncertainty obtained in the value of Λ$-2\atop{η}$ is lower than in previous results based on the η → e + e - γ decay. The value obtained for the ω slope parameter, Λ$-2\atop{ωπ^0}$ = (1.99 ± 0.21 tot ) GeV -2 , is somewhat lower than previous measurements based on ω → π 0 μ + μ - , but the results for the ω transition form factor are in better agreement with theoretical calculations, compared to earlier experiments.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Search for Light Gauge Bosons of the Dark Sector at the Mainz Microtron

A new exclusion limit for the electromagnetic production of a light U(1) gauge boson {gamma}{sup '} decaying to e{sup +}e{sup -} was determined by the A1 Collaboration at the Mainz Microtron. Such light gauge bosons appear in several extensions of the standard model and are also discussed as candidates for the interaction of dark matter with standard model matter. In electron scattering from a heavy nucleus, the existing limits for a narrow state coupling to e{sup +}e{sup -} were reduced by nearly an order of magnitude in the range of the lepton pair mass of 210 MeV/c{sup 2}<m{sub e}{sup +}{sub e}{sup -}<300 MeV/c{sup 2}. This experiment demonstrates the potential of high current and high resolution fixed target experiments for the search for physics beyond the standard model.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Experimental study of the γ p → π 0 η p reaction with the A2 setup at the Mainz Microtron

Here, the data available from the A2 Collaboration at MAMI were analyzed to select the γp → π 0 ηp reaction on an event-by-event basis, which allows for partial-wave analyses of three-body final states to obtain more reliable results, compared to fits to measured distributions. These data provide the world’s best statistical accuracy in the energy range from threshold to E γ = 1.45 GeV, allowing a finer energy binning in the measurement of all observables needed for understanding the reaction dynamics. The results obtained for the measured observables are compared to existing models, and the impact from the new data is checked by the fit with the revised Mainz model.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗