Search NASA⌕ Search

SEARCH · Search NASA

Results for “MICROWAVE INTERFEROMETER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Assessment of the beam path deflection for a vertically installed microwave interferometer in SUNIST

Microwave interferometry has been widely employed to provide reliable line averaged electron density measurement on plasma devices. For a vertically installed interferometer on a tokamak, the refraction problem, which distorts the beam path and aggravates power loss at the receiving antenna, may become significant if taking the cross section shape into account. Increasing the frequency of the probing microwave can alleviate the distortion, but at the expense of losing the density resolution. To seek for an optimized frequency, previous calculations are mainly based on the cylindrical column geometry which grossly underestimates the deflection of the beam path induced by the plasma shape, and empirical suggestions indicating n{sub e0}/n{sub c} = 1/2 ∼ 1/3 may not always be the appropriate option. Here a single ray tracing method is applied to estimate the final horizontal deviation at the receiving antenna, which is supposed to represent the level of power loss. The calculation is carried out under the real tokamak geometry in Sino-UNIted Spherical Tokamak (SUNIST) with the cross section parameters obtained from the equilibrium reconstruction, and the result indicates that for a target density of 1.2 × 10{sup 19} m{sup −3}, a frequency of at least 100 GHz is desirable to reduce the power loss to an acceptable level. This would be helpful for the design of a vertically installed interferometer on SUNIST.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Microwave interferometer controls cutting depth of plastics

Microwave interferometer system controls the cutting of plastic materials to a prescribed depth. The interferometer is mounted on a carriage with a spindle and cutting tool. A cross slide, mounted on the carriage, allows the interferometer and cutter to move toward or away from the plastic workpiece.

Heisman, R. M.↗

A high speed compact microwave interferometer for density fluctuation measurements in Sino-UNIted Spherical Tokamak

A single-channel 3 mm interferometer has been developed for plasma density diagnostics in the Sino-UNIted Spherical Tokamak (SUNIST). The extremely compact microwave interferometer utilizes one corrugated feed horn antenna for both emitting and receiving the microwave. The beam path lies on the equatorial plane so the system would not suffer from beam path deflection problems due to the symmetry of the cross section. A focusing lens group and an oblique vacuum window are carefully designed to boost the signal to noise ratio, which allows this system to show good performance even with the small-diameter central column itself as a reflector, without a concave mirror. The whole system discards the reference leg for maximum compactness, which is particularly suitable for the small-sized tokamak. An auto-correcting algorithm is developed to calculate the phase evolution, and the result displays good phase stability of the whole system. The intermediate frequency is adjustable and can reach its full potential of 2 MHz for best temporal resolution. Multiple measurements during ohmic discharges proved the interferometer’s capability to track typical density fluctuations in SUNIST, which enables this system to be utilized in the study of MHD activities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The space microwave interferometer and the search for cosmic background gravitational wave radiation

Present and planned investigations which use interplanetary spacecraft for gravitational wave searches are severely limited in their detection capability. This limitation has to do both with the Earth-based tracking procedures used and with the configuration of the experiments themselves. It is suggested that a much improved experiment can now be made using a multiarm interferometer designed with current operating elements. An important source of gravitational wave radiation, the cosmic background, may well be within reach of detection with these procedures. It is proposed to make a number of experimental steps that can now be carried out using TDRSS spacecraft and would conclude in the establishment of an operating multiarm microwave interferometer. This interferometer is projected to have a sensitivity to cosmic background gravitational wave radiation with an energy of less than 10(exp -4) cosmic closure density and to periodic waves generating spatial strain approaching 10(exp -19) in the range 0.1 to 0.001 Hz.

Anderson, Allen Joel↗

A metal-ceramic coaxial cable Fabry-Pérot microwave interferometer for monitoring fluid dielectric constant

We report a metal-ceramic coaxial cable Fabry-Pérot interferometer (MCCC-FPI) has been developed as a new microwave sensor and demonstrated for fast and reliably measuring and continuously monitoring dielectric constants for pure and mixed liquids. The sensor only requires a simple reference scan of the interferogram for the FPI with its sensing chamber filled with air or under vacuum to determine the actual inter-reflector length. The sensor is validated by measuring room temperature dielectric constant (εr) at high frequencies around 1.4–4.7 GHz for three vegetable oils (corn, sesame, and olive), the synthetic Mobil ® -1 engine oil, and mixtures containing sesame oil and water. The sensor has been also successfully demonstrated for determining εr values for the Mobil-1 oil at various temperatures and for the well-dispersed sesame oil-water mixtures of different compositions. The Bottcher’s model of effective medium theory is shown to be better suited for predicting the ε r of the sesame oil-water mixture than the Maxwell-Garnett and Bruggeman equations of spherical solutions.

47 OTHER INSTRUMENTATION↗

A Polarimetric Extension of the van Cittert-Zernike Theorem for Use with Microwave Interferometers

The van Cittert-Zernike theorem describes the Fourier-transform relationship between an extended source and its visibility function. Developments in classical optics texts use scalar field formulations for the theorem. Here, we develop a polarimetric extension to the van Cittert-Zernike theorem with applications to passive microwave Earth remote sensing. The development provides insight into the mechanics of two-dimensional interferometric imaging, particularly the effects of polarization basis differences between the scene and the observer.

Piepmeier, J. R.↗

Design and characterization of a single-channel microwave interferometer for the Helicon Physics Prototype eXperiment

A heterodyne interferometer for measuring the plasma electron density in Helicon Physics Prototype eXperiment (HPPX) has been developed and characterized in the laboratory. The heterodyne-type interferometer uses a probing beam of 85 GHz and a reference beam of 85.7 GHz by using two Gunn oscillators for facilitating frequency modulation. The cutoff density for this frequency is 8.96 x 10 19 m –3 that is much higher than the nominal electron density of the HPPX plasmas. The maximum deflection angle due to the refraction effect is estimated to be 0.63° assuming a parabolic electron density profile, and the impact on the measurement is negligible for the plasmas with a size of 100 mm. Two identical HDPE lenses act as the vacuum windows, and the lenses working together with the transmitter and receiver horns, form a beam with the beam waist of about 20 mm located at the plasma center. The characterization results of the lens and the critical microwave components show good performance. The plasma electron density measurement results are in line with the expectation. Furthermore, the Signal to Noise Ratio (SNR) of the measurement is defined as SNR = 20lg($\bar{n}_{e}$/S), where $\bar{n}_{e}$ and S are respectively the average electron density and the standard deviation of the signal, and the SNR is 80 dB. Finally, this demonstrates the system's capability of providing a clear and detailed density resolution.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Instrument Reflections and Scene Amplitude Modulation in a Polychromatic Microwave Quadrature Interferometer

A polychromatic microwave quadrature interferometer has been characterized using several laboratory plasmas. Reflections between the transmitter and the receiver have been observed, and the effects of including reflection terms in the data reduction equation have been examined. An error analysis which includes the reflections, modulation of the scene beam amplitude by the plasma, and simultaneous measurements at two frequencies has been applied to the empirical database, and the results are summarized. For reflection amplitudes around 1096, the reflection terms were found to reduce the calculated error bars for electron density measurements by about a factor of 2. The impact of amplitude modulation is also quantified. In the complete analysis, the mean error bar for high- density measurements is 7.596, and the mean phase shift error for low-density measurements is 1.2". .

Dobson, Chris C.↗

Low-noise interferometer for microwave radiometry

An interferometer for precision measurements in microwave radiometry is proposed which uses two low-noise heterodyne receivers based on SIS tunnel junction mixers in the 40-50-GHz band. The antenna interference pattern has lobes which lead to positive output signals and lobes which give negative output, and the radiometer measures the difference in the power from these lobes without beam switching or instrument motion. The present system cancels instrumental signals, has a very low 1/f noise in the output, and has a zero outpus signal when viewing a uniform source. It is noted that application of the interferometer may be limited to radiometry with relatively large beams.

Timbie, P. T.↗

Study of detached plasma profile in the divertor simulation experimental module of tandem mirror GAMMA 10/PDX

A divertor simulation experimental module (D-module) in the tandem mirror GAMMA 10/PDX was used for the study of plasma detachment. In previous studies, it was difficult to measure far-upstream plasma parameters in the D-module, and only electrostatic probes on the target plate were used to perform electron temperature and density measurements. Furthermore, to study the detached plasma structure, a Thomson scattering (TS) system and a microwave interferometer system have been installed to measure the inside plasma parameters of the D-module, and a movable electrostatic probe has been placed at the inlet of the D-module to measure the inlet plasma density and temperature. The TS system in the central cell observed the electron temperature and density of the core plasma simultaneously. These measurements revealed the entire density and temperature structure from the core plasma to the divertor plate. The line average electron density measured by the microwave interferometer showed a rollover behavior during detachment. The results indicated that the ionization region was located around the center of the D-module, and it appears to move upstream along the axis.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Reactive flow modeling of small scale detonation failure experiments for a baseline non-ideal explosive

Small scale characterization experiments using only 1–5 g of a baseline ammonium nitrate plus fuel oil (ANFO) explosive are discussed and simulated using an ignition and growth reactive flow model. There exists a strong need for the small scale characterization of non-ideal explosives in order to adequately survey the wide parameter space in sample composition, density, and microstructure of these materials. However, it is largely unknown in the scientific community whether any useful or meaningful result may be obtained from detonation failure, and whether a minimum sample size or level of confinement exists for the experiments. In this work, it is shown that the parameters of an ignition and growth rate law may be calibrated using the small scale data, which is obtained from a 35 GHz microwave interferometer. Calibration is feasible when the samples are heavily confined and overdriven; this conclusion is supported with detailed simulation output, including pressure and reaction contours inside the ANFO samples. The resulting shock wave velocity is most likely a combined chemical-mechanical response, and simulations of these experiments require an accurate unreacted equation of state (EOS) in addition to the calibrated reaction rate. Other experiments are proposed to gain further insight into the detonation failure data, as well as to help discriminate between the role of the EOS and reaction rate in predicting the measured outcome.

42 ENGINEERING↗

Microwave frequency sweep interferometer for plasma density measurements in ECR ion sources: Design and preliminary results

The Electron Cyclotron Resonance Ion Sources (ECRISs) development is strictly related to the availability of new diagnostic tools, as the existing ones are not adequate to such compact machines and to their plasma characteristics. Microwave interferometry is a non-invasive method for plasma diagnostics and represents the best candidate for plasma density measurement in hostile environment. Interferometry in ECRISs is a challenging task mainly due to their compact size. The typical density of ECR plasmas is in the range 10{sup 11}–10{sup 13} cm{sup −3} and it needs a probing beam wavelength of the order of few centimetres, comparable to the chamber radius. The paper describes the design of a microwave interferometer developed at the LNS-INFN laboratories based on the so-called “frequency sweep” method to filter out the multipath contribution in the detected signals. The measurement technique and the preliminary results (calibration) obtained during the experimental tests will be presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Electro-optic modulation of a laser at microwave frequencies for interferometric purposes

A multi-point microwave interferometer (MPMI) concept was previously proposed by the authors for spatially-resolved, non-invasive tracking of a shock, reaction, or detonation front in energetic media [P. Specht et al., AIP Conf. Proc. 1793, 160010 (2017).]. The advantage of the MPMI concept over current microwave interferometry techniques is its detection of Doppler shifted microwave signals through electro-optic (EO) modulation of a laser. Since EO modulation preserves spatial variations in the Doppler shift, collecting the EO modulated laser light into a fiber array for recording with an optical heterodyne interferometer yields spatially-resolved velocity information. This work demonstrates the underlying physical principle of the MPMI diagnostic: the monitoring of a microwave signal with nanosecond temporal resolution using an optical heterodyne interferometer. For this purpose, the MPMI concept was simplified to a single-point construction using two tunable 1550 nm lasers and a 35.2 GHz microwave source. A (110) ZnTe crystal imparted the microwave frequency onto a laser, which was combined with a reference laser for determination of the microwave frequency in an optical heterodyne interferometer. A single, characteristic frequency associated with the microwave source was identified in all experiments, providing a means to monitor a microwave signal on nanosecond time scales. Lastly, areas for improving the frequency resolution of this technique are discussed, focusing on increasing the phase-modulated signal strength.

Specht, Paul E. (ORCID:000000027007000X)↗

Plasma decay in hydrocarbons and hydrocarbon- and H 2 O-containing mixtures excited by high-voltage nanosecond discharge at elevated gas temperatures

Plasma decay after a high-voltage nanosecond discharge was experimentally and numerically studied in pure hydrocarbons (C 2 H 6 and C 3 H 8 ), and H 2 O:N 2 and C 3 H 8 :O 2 mixtures for pressures in the range 2–4 Torr and gas temperatures from 300 to 600 K. In a stoichiometric C 3 H 8 :O 2 mixture, plasma decay was also studied in a repetitively pulsed discharge for varing numbers of discharge pulses (varying degrees of fuel oxidation). The rate of plasma decay was determined from the temporal evolution of electron density measured using the microwave interferometer. It was observed that gas heating to 600 K leads to a decrease in the rate of plasma decay in all cases. The effect of heating on plasma decay was most profound in the H 2 O:N 2 mixture (after a single discharge pulse) and in the C 3 H 8 :O 2 mixture for high degrees of fuel oxidation. A kinetic scheme was developed to numerically simulate the plasma decay in hydrocarbons and combustible mixtures. Numerical analysis showed that, under the conditions studied, plasma decay was controlled by dissociative electron recombination with simple molecular and cluster ions. Gas heating led to a decrease in the rate of the electron-ion recombination and the rate of conversion of molecular ions to cluster ions. As a result, the gas temperature increase caused a decrease in the fraction of cluster ions for which the recombination coefficients are an order of magnitude higher than the recombination coefficients for molecular ions. The influence of gas heating on the decrease of the amount of cluster ions was more important when the ion composition was dominated by hydrated H 3 O + (H 2 O) k ions. The rates of the formation of these ions are extremely sensitive to any variations in gas temperature. A result, in agreement with our observations, gas heating led to an anomalous decrease in the rates of plasma decay in the H 2 O:N 2 mixture, as well as in the C 3 H 8 :O 2 mixture when H 2 O molecules were produced due to fuel oxidation.

20 FOSSIL-FUELED POWER PLANTS↗