Assessment of the beam path deflection for a vertically installed microwave interferometer in SUNIST

Microwave interferometry has been widely employed to provide reliable line averaged electron density measurement on plasma devices. For a vertically installed interferometer on a tokamak, the refraction problem, which distorts the beam path and aggravates power loss at the receiving antenna, may become significant if taking the cross section shape into account. Increasing the frequency of the probing microwave can alleviate the distortion, but at the expense of losing the density resolution. To seek for an optimized frequency, previous calculations are mainly based on the cylindrical column geometry which grossly underestimates the deflection of the beam path induced by the plasma shape, and empirical suggestions indicating n{sub e0}/n{sub c} = 1/2 ∼ 1/3 may not always be the appropriate option. Here a single ray tracing method is applied to estimate the final horizontal deviation at the receiving antenna, which is supposed to represent the level of power loss. The calculation is carried out under the real tokamak geometry in Sino-UNIted Spherical Tokamak (SUNIST) with the cross section parameters obtained from the equilibrium reconstruction, and the result indicates that for a target density of 1.2 × 10{sup 19} m{sup −3}, a frequency of at least 100 GHz is desirable to reduce the power loss to an acceptable level. This would be helpful for the design of a vertically installed interferometer on SUNIST.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multichannel microwave interferometer for the levitated dipole experiment

A four-channel microwave interferometer (center frequency: 60 GHz) has been constructed to measure plasma density profiles in the levitated dipole experiment (LDX). The LDX interferometer has a unique design owing to the unique geometry of LDX. The main design features of the interferometer are: (1) the transmitted beam traverses the plasma entirely in O-mode; (2) the interferometer is a heterodyne system employing two free-running oscillators; (3) four signals of data are received from just on transmitted beam; (4) phase shifts are detected in quadrature. Calibration tests demonstrate that the interferometer measures phase shifts with an uncertainty of approximately 5 deg. Plasma densities in LDX corresponding to phase shifts of up to 5{pi} are routinely and successfully measured.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High accuracy plasma density measurement using hybrid Langmuir probe and microwave interferometer method

High spatial resolution plasma density measurements have been taken as part of an investigation into magnetic nozzle physics at the NASA/MSFC Propulsion Research Center. These measurements utilized a Langmuir triple probe scanned across the measurement chord of either of two stationary rf interferometers. By normalizing the scanned profile to the microwave interferometer line-integrated density measurement for each electrostatic probe measurement, the effect of shot-to-shot variation of the line-integrated density can be removed. In addition, by summing the voltage readings at each radial position in a transverse scan, the line density can be reconstituted, allowing the absolute density to be determined, assuming that the shape of the profile is constant from shot to shot. The spatial and temporal resolutions of this measurement technique depend on the resolutions of the scanned electrostatic probe and the interferometer. The measurement accuracy is 9%-15%, which is on the order of the accuracy of the rf interferometer. The measurement technique was compared directly with both scanning rf interferometer and standard Langmuir probe theory. The hybrid technique compares favorably with the scanning rf interferometer, and appears more accurate than probe theory alone. Additionally, our measurement technique is generally applicable even for nonaxisymmetric plasmas.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A microwave interferometer for small and tenuous plasma density measurements

The non-intrusive density measurement of the thin plasma produced by a mini-helicon space thruster (HPH.com project) is a challenge, due to the broad density range (between 10{sup 16} m{sup -3} and 10{sup 19} m{sup -3}) and the small size of the plasma source (2 cm of diameter). A microwave interferometer has been developed for this purpose. Due to the small size of plasma, the probing beam wavelength must be small ({lambda}= 4 mm), thus a very high sensitivity interferometer is required in order to observe the lower density values. A low noise digital phase detector with a phase noise of 0.02 Degree-Sign has been used, corresponding to a density of 0.5 Multiplication-Sign 10{sup 16} m{sup -3}.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multichannel microwave interferometer with an antenna switching system for electron density measurement in a laboratory plasma experiment

This study presents a simple and powerful technique for multichannel measurements of the density profile in laboratory plasmas by microwave interferometry. This technique uses electromechanical microwave switches to temporally switch the connection between multiple receiver antennas and one phase-detection circuit. Using this method, the phase information detected at different positions is rearranged into a time series that can be acquired from a minimum number of data acquisition channels (e.g., two channels in the case of quadrature detection). Our successfully developed multichannel microwave interferometer that uses the antenna switching method was applied to measure the radial electron density profiles in a magnetized plasma experiment. The advantage of the proposed method is its compactness and scalability to multidimensional measurement systems at low cost.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A high speed compact microwave interferometer for density fluctuation measurements in Sino-UNIted Spherical Tokamak

A single-channel 3 mm interferometer has been developed for plasma density diagnostics in the Sino-UNIted Spherical Tokamak (SUNIST). The extremely compact microwave interferometer utilizes one corrugated feed horn antenna for both emitting and receiving the microwave. The beam path lies on the equatorial plane so the system would not suffer from beam path deflection problems due to the symmetry of the cross section. A focusing lens group and an oblique vacuum window are carefully designed to boost the signal to noise ratio, which allows this system to show good performance even with the small-diameter central column itself as a reflector, without a concave mirror. The whole system discards the reference leg for maximum compactness, which is particularly suitable for the small-sized tokamak. An auto-correcting algorithm is developed to calculate the phase evolution, and the result displays good phase stability of the whole system. The intermediate frequency is adjustable and can reach its full potential of 2 MHz for best temporal resolution. Multiple measurements during ohmic discharges proved the interferometer’s capability to track typical density fluctuations in SUNIST, which enables this system to be utilized in the study of MHD activities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A metal-ceramic coaxial cable Fabry-Pérot microwave interferometer for monitoring fluid dielectric constant

We report a metal-ceramic coaxial cable Fabry-Pérot interferometer (MCCC-FPI) has been developed as a new microwave sensor and demonstrated for fast and reliably measuring and continuously monitoring dielectric constants for pure and mixed liquids. The sensor only requires a simple reference scan of the interferogram for the FPI with its sensing chamber filled with air or under vacuum to determine the actual inter-reflector length. The sensor is validated by measuring room temperature dielectric constant (εr) at high frequencies around 1.4–4.7 GHz for three vegetable oils (corn, sesame, and olive), the synthetic Mobil ® -1 engine oil, and mixtures containing sesame oil and water. The sensor has been also successfully demonstrated for determining εr values for the Mobil-1 oil at various temperatures and for the well-dispersed sesame oil-water mixtures of different compositions. The Bottcher’s model of effective medium theory is shown to be better suited for predicting the ε r of the sesame oil-water mixture than the Maxwell-Garnett and Bruggeman equations of spherical solutions.

47 OTHER INSTRUMENTATION↗

Design and characterization of a single-channel microwave interferometer for the Helicon Physics Prototype eXperiment

A heterodyne interferometer for measuring the plasma electron density in Helicon Physics Prototype eXperiment (HPPX) has been developed and characterized in the laboratory. The heterodyne-type interferometer uses a probing beam of 85 GHz and a reference beam of 85.7 GHz by using two Gunn oscillators for facilitating frequency modulation. The cutoff density for this frequency is 8.96 x 10 19 m –3 that is much higher than the nominal electron density of the HPPX plasmas. The maximum deflection angle due to the refraction effect is estimated to be 0.63° assuming a parabolic electron density profile, and the impact on the measurement is negligible for the plasmas with a size of 100 mm. Two identical HDPE lenses act as the vacuum windows, and the lenses working together with the transmitter and receiver horns, form a beam with the beam waist of about 20 mm located at the plasma center. The characterization results of the lens and the critical microwave components show good performance. The plasma electron density measurement results are in line with the expectation. Furthermore, the Signal to Noise Ratio (SNR) of the measurement is defined as SNR = 20lg($\bar{n}_{e}$/S), where $\bar{n}_{e}$ and S are respectively the average electron density and the standard deviation of the signal, and the SNR is 80 dB. Finally, this demonstrates the system's capability of providing a clear and detailed density resolution.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Study of detached plasma profile in the divertor simulation experimental module of tandem mirror GAMMA 10/PDX

A divertor simulation experimental module (D-module) in the tandem mirror GAMMA 10/PDX was used for the study of plasma detachment. In previous studies, it was difficult to measure far-upstream plasma parameters in the D-module, and only electrostatic probes on the target plate were used to perform electron temperature and density measurements. Furthermore, to study the detached plasma structure, a Thomson scattering (TS) system and a microwave interferometer system have been installed to measure the inside plasma parameters of the D-module, and a movable electrostatic probe has been placed at the inlet of the D-module to measure the inlet plasma density and temperature. The TS system in the central cell observed the electron temperature and density of the core plasma simultaneously. These measurements revealed the entire density and temperature structure from the core plasma to the divertor plate. The line average electron density measured by the microwave interferometer showed a rollover behavior during detachment. The results indicated that the ionization region was located around the center of the D-module, and it appears to move upstream along the axis.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Reactive flow modeling of small scale detonation failure experiments for a baseline non-ideal explosive

Small scale characterization experiments using only 1–5 g of a baseline ammonium nitrate plus fuel oil (ANFO) explosive are discussed and simulated using an ignition and growth reactive flow model. There exists a strong need for the small scale characterization of non-ideal explosives in order to adequately survey the wide parameter space in sample composition, density, and microstructure of these materials. However, it is largely unknown in the scientific community whether any useful or meaningful result may be obtained from detonation failure, and whether a minimum sample size or level of confinement exists for the experiments. In this work, it is shown that the parameters of an ignition and growth rate law may be calibrated using the small scale data, which is obtained from a 35 GHz microwave interferometer. Calibration is feasible when the samples are heavily confined and overdriven; this conclusion is supported with detailed simulation output, including pressure and reaction contours inside the ANFO samples. The resulting shock wave velocity is most likely a combined chemical-mechanical response, and simulations of these experiments require an accurate unreacted equation of state (EOS) in addition to the calibrated reaction rate. Other experiments are proposed to gain further insight into the detonation failure data, as well as to help discriminate between the role of the EOS and reaction rate in predicting the measured outcome.

42 ENGINEERING↗

A Software Tool for Processing the Displacement Time Series Extracted from Raw Radar Data

The application of high-resolution radar waveform and interferometric principles recently led to the development of a microwave interferometer, suitable to simultaneously measuring the (static or dynamic) deflection of several points on a large structure. From the technical standpoint, the sensor is a Stepped Frequency Continuous Wave (SF-CW), coherent radar, operating in the K{sub u} frequency band.In the paper, the main procedures adopted to extract the deflection time series from raw radar data and to assess the quality of data are addressed, and the MATLAB toolbox developed is described. Subsequently, other functions implemented in the software tool (e.g. evaluation of the spectral matrix of the deflection time-histories, identification of natural frequencies and operational mode shapes evaluation) are described and the application to data recorded on full-scale bridges is exemplified.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

High-resolution Thomson scattering system on the COMPASS tokamak: Evaluation of plasma parameters and error analysis

The electron density and temperature profiles measured by the Thomson scattering diagnostic on the COMPASS tokamak are used for estimation of electron kinetic energy, energy confinement time, and effective charge number Z{sub eff}. Data are compared with the line-integrated electron density measured by a microwave interferometer in an ohmically heated plasma with a circular cross section. An error analysis of both electron temperature and density are performed by two methods-a constant chi-square boundaries method and a Monte Carlo simulation, determining asymmetrical error bars for the electron temperature.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Microwave frequency sweep interferometer for plasma density measurements in ECR ion sources: Design and preliminary results

The Electron Cyclotron Resonance Ion Sources (ECRISs) development is strictly related to the availability of new diagnostic tools, as the existing ones are not adequate to such compact machines and to their plasma characteristics. Microwave interferometry is a non-invasive method for plasma diagnostics and represents the best candidate for plasma density measurement in hostile environment. Interferometry in ECRISs is a challenging task mainly due to their compact size. The typical density of ECR plasmas is in the range 10{sup 11}–10{sup 13} cm{sup −3} and it needs a probing beam wavelength of the order of few centimetres, comparable to the chamber radius. The paper describes the design of a microwave interferometer developed at the LNS-INFN laboratories based on the so-called “frequency sweep” method to filter out the multipath contribution in the detected signals. The measurement technique and the preliminary results (calibration) obtained during the experimental tests will be presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Investigation of helicon ion source extraction systems

Various versions of an extraction system for a helicon ion source have been investigated in high plasma density (>10{sup 12} cm{sup -3}) modes. The measurements of the plasma density were carried out with a microwave interferometer. Experiments were performed with hydrogen and helium gases. The preliminary results indicate that specially designed extractors are very promising for improving ion beam paraxial brightness.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗