Search NASA⌕ Search

SEARCH · Search NASA

Results for “MICROWAVE PLASMA PROBE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Theoretical and experimental study of the microwave cut-off probe for electron density measurements in low-temperature plasmas

The microwave cut-off probe for the electron density measurement in low-temperature plasmas is described in this article. It is based on the wave cutoff in an unmagnetized plasma. The measurement principle is analyzed theoretically using a model of plasma slab. Because of the high-pass characteristic of plasma, the waves above the cut-off frequency can penetrate the plasma slab, whereas the lower frequency waves are reflected from the cut-off layer. Therefore, an obvious critical point can be observed in the wave transmission spectrum. The abscissa of the critical point indicates the cut-off frequency, which is directly related to the maximum electron density between transmitting/receiving antennas of the cut-off probe. The measured electron densities are in agreement with the data obtained by the Langmuir probe. Experimental results show that the microwave cut-off probe can be used to diagnose the plasmas with a wide range of parameters.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High accuracy plasma density measurement using hybrid Langmuir probe and microwave interferometer method

High spatial resolution plasma density measurements have been taken as part of an investigation into magnetic nozzle physics at the NASA/MSFC Propulsion Research Center. These measurements utilized a Langmuir triple probe scanned across the measurement chord of either of two stationary rf interferometers. By normalizing the scanned profile to the microwave interferometer line-integrated density measurement for each electrostatic probe measurement, the effect of shot-to-shot variation of the line-integrated density can be removed. In addition, by summing the voltage readings at each radial position in a transverse scan, the line density can be reconstituted, allowing the absolute density to be determined, assuming that the shape of the profile is constant from shot to shot. The spatial and temporal resolutions of this measurement technique depend on the resolutions of the scanned electrostatic probe and the interferometer. The measurement accuracy is 9%-15%, which is on the order of the accuracy of the rf interferometer. The measurement technique was compared directly with both scanning rf interferometer and standard Langmuir probe theory. The hybrid technique compares favorably with the scanning rf interferometer, and appears more accurate than probe theory alone. Additionally, our measurement technique is generally applicable even for nonaxisymmetric plasmas.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Synthetic aperture microwave imaging with active probing for fusion plasma diagnostics

A Synthetic Aperture Microwave Imaging (SAMI) system has been designed and built to obtain 2-D images at several frequencies from fusion plasmas. SAMI uses a phased array of linearly polarised antennas. The array configuration has been optimised to achieve maximum synthetic aperture beam efficiency. The signals received by antennas are down-converted to the intermediate frequency range and then recorded in a full vector form. Full vector signals allow beam focusing and image reconstruction in both real time and a post-processing mode. SAMI can scan over 16 pre-programmed frequencies in the range of 10-35GHz with a switching time of 300ns. The system operates in 2 different modes simultaneously: both a 'passive' imaging of plasma emission and also an 'active' imaging of the back-scattered signal of the radiation launched by one of the antennas from the same array. This second mode is similar to so-called Doppler backscattering (DBS) reflectometry with 2-D resolution of the propagation velocity of turbulent structures. Both modes of operation show good performance in fusion plasma experiments on Mega Amp Spherical Tokamak (MAST). We have obtained the first ever 2-D images of BXO mode conversion windows. With active probing, first ever turbulence velocity maps have been obtained. We present an overview of the diagnostic and discuss recent results. In contrast to quasi-optical microwave imaging systems SAMI requires neither big aperture viewing ports nor large 2-D detector arrays to achieve the desired imaging resolution. The number of effective 'pixels' of the synthesized image is proportional to the number of receiving antennas squared. Thus only a small number of optimised antennas is sufficient for the majority of applications. Possible implementation of SAMI on ITERand DEMO is discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Microwave resonances of a hairpin probe in a magnetized plasma

The effect due to the electron cyclotron frequency on the microwave resonances of a hairpin probe is investigated in a moderate to strongly magnetized plasma. The magnetic field is independently varied over a wide range from 0.01-0.13 T while maintaining the local plasma density constant. At strong magnetic fields the resonance frequency is found to be lower than that measured in vacuum implying that the relative plasma dielectric permittivity, epsilon{sub p}>1. It is proposed that the experiments reported here are consistent with a permittivity model that includes magnetic field.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Probing the plasma chemistry in a microwave reactor used for diamond chemical vapor deposition by cavity ring down spectroscopy

Absolute column densities of C{sub 2}(a) and CH radicals and H(n=2) atoms have been measured in a diamond growing microwave reactor operating with hydrocarbon/Ar/H{sub 2} gas mixtures as functions of height (z) above the substrate surface and process conditions. The monitored species are each localized in the hot plasma region, where T{sub gas}{approx}3000 K, and their respective column densities are each reproduced, quantitatively, by two-dimensional (r,z) modeling of the plasma chemistry. The H(n=2) distribution is seen to peak nearer the substrate, reflecting its sensitivity both to thermal chemistry (which drives the formation of ground state H atoms) and the distributions of electron density (n{sub e}) and temperature (T{sub e}). All three column densities are found to be sensitively dependent on the C/H ratio in the process gas mixture but insensitive to the particular choice of hydrocarbon (CH{sub 4} and C{sub 2}H{sub 2}). The excellent agreement between measured and predicted column densities for all three probed species, under all process conditions investigated, encourages confidence in the predicted number densities of other of the more abundant radical species adjacent to the growing diamond surface which, in turn, reinforces the view that CH{sub 3} radicals are the dominant growth species in microwave activated hydrocarbon/Ar/H{sub 2} gas mixtures used in the chemical vapor deposition of microcrystalline and single crystal diamond samples.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Measurement of effective sheath width around cutoff probe in low-pressure plasmas

Previous studies indicated that the measurement results of microwave probes can be improved by applying the adequate sheath width to their measurement models, and consequently the sheath width around the microwave probe tips has become very important information for microwave probe diagnostics. In this paper, we propose a method for measuring the argon plasma sheath width around the cutoff probe tips by applying the circuit model to the cutoff probe phase spectrum. The measured sheath width of the cutoff probe was found to be in good agreement with the floated sheath width calculated from the Child-Langmuir sheath law. The physical reasons for a discrepancy between the two measurements are also discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Determination of the electron density in plasma by means of a floating double probe

Investigations are performed in a microwave plasma expansion containing argon-nitrogen gas mixture. The purpose of this work is to measure accurate electron density values by means of a floating double probe. We check the accuracy of the different methods developed for the double probe under different experimental conditions in Ar-N{sub 2} gas mixture, comparing results to single probe measurements. On the basis of previous works, we propose a simple way to determine the electron density without the knowledge of the plasma potential.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Electric probe investigations of microwave generated, atmospheric pressure, plasma jets

We examine the applicability of the Langmuir-type of characterization for atmospheric pressure plasma jets generated in a millimeter-size cavity microwave resonator at 2.45 GHz. Wide range I-V characteristics of helium, argon, nitrogen, air and oxygen are presented for different gas fluxes, distances probe-resonator, and microwave powers. A detailed analysis is performed for the fine variation in the current around the floating potential. A simplified theory specially developed for this case is presented, considering the ionic and electronic saturation currents and the floating potential. Based on this theory, we conclude that, while the charge carrier density depends on gas flow, distance to plasma source, and microwave absorbed power, the electron temperature is quite independent of these parameters. The resulting plasma parameters for helium, argon, and nitrogen are presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Observation of plasma instabilities related to dust particle growth mechanisms in electron cyclotron resonance plasmas

Instabilities are observed in the self-bias voltage measured on a probe immersed in microwave plasma excited at Electron Cyclotron Resonance (ECR). Observed in the MHz range, they were systematically measured in dust-free or dusty plasmas (obtained for different conditions of applied microwave powers and acetylene flow rates). Two characteristic frequencies, well described as lower hybrid oscillations, can be defined. The first one, in the 60–70 MHz range, appears as a sharp peak in the frequency spectra and is observed in every case. Attributed to ions, its position shift observed with the output power highlights that nucleation process takes place in the dusty plasma. Attributed to lower hybrid oscillation of powders, the second broad peak in the 10–20 MHz range leads to the characterization of dust particles growth mechanisms: in the same way as in capacitively coupled plasmas, accumulation of nucleus confined near the probe in the magnetic field followed by aggregation takes place. Then, the measure of electrical instabilities on the self-bias voltage allows characterizing the discharge as well as the chemical processes that take place in the magnetic field region and their kinetics.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Electrical characterization of the flowing afterglow of N{sub 2} and N{sub 2}/O{sub 2} microwave plasmas at reduced pressure

A cylindrical Langmuir probe was used to analyze the spatial distribution of the number density of positive ions and electrons as well as the electron energy distribution function (EEDF) in the flowing afterglow of a 6 Torr N{sub 2} and N{sub 2}/O{sub 2} plasma sustained by a propagating electromagnetic surface wave in the microwave regime. In pure N{sub 2} discharges, ion densities were in the mid 10{sup 14} m{sup −3} in the pink afterglow and in the mid 10{sup 12} m{sup −3} early in the late afterglow. In both pink and late afterglows, the ion population was much higher than the electron population, indicating non-macroscopically neutral media. The EEDF was close to a Maxwellian with an electron temperature of 0.5 ± 0.1 eV, except in the pink afterglow where the temperature rose to 1.1 ± 0.2 eV. This latter behavior is ascribed to N{sub 2} vibration-vibration pumping in the pink afterglow that increases the concentration of high N{sub 2} vibrational states and thus rises the electron temperature by vibration-electron collisions. After addition of small amounts of O{sub 2} in the nominally pure N{sub 2} discharge, the charged particles densities and average electron energy first strongly increased and then decreased with increasing O{sub 2} concentration. Based on these data and the evolution of the N{sub 2}{sup +}(B) band emission intensities, it is concluded that a significant change in the positive ion composition of the flowing afterglow occurs, going from N{sub 2}{sup +} in nominally pure N{sub 2} discharges to NO{sup +} after addition of trace amounts of O{sub 2} in N{sub 2}.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Electron plasmas as a diagnostic tool for hyperfine spectroscopy of antihydrogen

Long term magnetic confinement of antihydrogen atoms has recently been demonstrated by the ALPHA collaboration at CERN, opening the door to a range of experimental possibilities. Of particular interest is a measurement of the antihydrogen spectrum. A precise comparison of the spectrum of antihydrogen with that of hydrogen would be an excellent test of CPT symmetry. One prime candidate for precision CPT tests is the ground-state hyperfine transition; measured in hydrogen to a precision of nearly one part in 10{sup 12}. Effective execution of such an experiment with trapped antihydrogen requires precise knowledge of the magnetic environment. Here we present a solution that uses an electron plasma confined in the antihydrogen trapping region. The cyclotron resonance of the electron plasma is probed with microwaves at the cyclotron frequency and the subsequent heating of the electron plasma is measured through the plasma quadrupole mode frequency. Using this method, the minimum magnetic field of the neutral trap can be determined to within 4 parts in 10{sup 4}. This technique was used extensively in the recent demonstration of resonant interaction with the hyperfine levels of trapped antihydrogen atoms.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Langmuir probe diagnostics of plasma in high current electron cyclotron resonance proton ion source

A high current Electron Cyclotron Resonance (ECR) proton ion source has been developed for low energy high intensity proton accelerator at Bhabha Atomic Research Centre. Langmuir probe diagnostics of the plasma generated in this proton ion source is performed using Langmuir probe. The diagnostics of plasma in the ion source is important as it determines beam parameters of the ion source, i.e., beam current, emittance, and available species. The plasma parameter measurement in the ion source is performed in continuously working and pulsed mode using hydrogen as plasma generation gas. The measurement is performed in the ECR zone for operating pressure and microwave power range of 10{sup −4}–10{sup −3} mbar and 400–1000 W. An automated Langmuir probe diagnostics unit with data acquisition system is developed to measure these parameters. The diagnostics studies indicate that the plasma density and plasma electron temperature measured are in the range 5.6 × 10{sup 10} cm{sup −3} to 3.8 × 10{sup 11} cm{sup −3} and 4–14 eV, respectively. Using this plasma, ion beam current of tens of mA is extracted. The variations of plasma parameters with microwave power, gas pressure, and radial location of the probe have been studied.

43 PARTICLE ACCELERATORS↗

Measurement of axial neutral density profiles in a microwave discharge ion thruster by laser absorption spectroscopy with optical fiber probes

In order to reveal the physical processes taking place within the ''{mu}10'' microwave discharge ion thruster, internal plasma diagnosis is indispensable. However, the ability of metallic probes to access microwave plasmas biased at a high voltage is limited from the standpoints of the disturbance created in the electric field and electrical isolation. In this study, the axial density profiles of excited neutral xenon were successfully measured under ion beam acceleration by using a novel laser absorption spectroscopy system. The target of the measurement was metastable Xe I 5p{sup 5}({sup 2}P{sup 0}{sub 3/2})6s[{sup 3}/{sub 2}]{sup 0}{sub 2} which absorbed a wavelength of 823.16 nm. Signals from laser absorption spectroscopy that swept a single-mode optical fiber probe along the line of sight were differentiated and converted into axial number densities of the metastable neutral particles in the plasma source. These measurements revealed a 10{sup 18} m{sup -3} order of metastable neutral particles situated in the waveguide, which caused two different modes during the operation of the {mu}10 thruster. This paper reports a novel spectroscopic measurement system with axial resolution for microwave plasma sources utilizing optical fiber probes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Experimental investigation of plasma flows in open trap with toroidal diverter under ECR discharge

The results of experimental investigations of plasma flows from an open trap with a toroidal diverter are presented. Cold plasma is generated when introducing microwave power under conditions of electron cyclotron resonance (ECR). The radiation is introduced by a waveguide through a vacuum-tight ceramic window across the axis of the device. By means of the Langmuir probes, the spatial distributions of plasma parameters are measured. The highest density is limited to a critical value n{sub c} (∼10{sup 12} cm{sup –3}) for the generator frequency under use. It is found that the temperature and density of the plasma in the trap and in escaping flows are almost independent of the radius when the ECR zone is located near the open-trap confinement region and the density is close to n{sub c}. At the density n < n{sub c}, ring plasma structures, which collapse under the action of a low-frequency instability, are observed near the separatrix. The possible mechanisms of the occurrence of plasma structures and the nature of the plasma streams are discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Probing the fields in an ultracold plasma by microwave spectroscopy

By observing the Stark shift of the Rb 42s{sub 1/2}-42p{sub 1/2} microwave transition we have measured the electric fields in an ultracold plasma formed by photoionizing Rb atoms in a magneto-optical trap. Using this approach and a model of the electron charge distribution we have been able to measure both the microscopic fields due to nearest-neighbor ions and the macroscopic fields due to the charge imbalance in the plasma.

74 ATOMIC AND MOLECULAR PHYSICS↗

Beam current enhancement of microwave plasma ion source utilizing double-port rectangular cavity resonator

Microwave plasma ion source with rectangular cavity resonator has been examined to improve ion beam current by changing wave launcher type from single-port to double-port. The cavity resonators with double-port and single-port wave launchers are designed to get resonance effect at TE-103 mode and TE-102 mode, respectively. In order to confirm that the cavities are acting as resonator, the microwave power for breakdown is measured and compared with the E-field strength estimated from the HFSS (High Frequency Structure Simulator) simulation. Langmuir probe measurements show that double-port cavity enhances central density of plasma ion source by modifying non-uniform plasma density profile of the single-port cavity. Correspondingly, beam current from the plasma ion source utilizing the double-port resonator is measured to be higher than that utilizing single-port resonator. Moreover, the enhancement in plasma density and ion beam current utilizing the double-port resonator is more pronounced as higher microwave power applied to the plasma ion source. Therefore, the rectangular cavity resonator utilizing the double-port is expected to enhance the performance of plasma ion source in terms of ion beam extraction.

43 PARTICLE ACCELERATORS↗

Development of asymmetric double probe formula and its application for collisional plasmas

The ratio of the electron and ion saturation currents in single probe I-V characteristics for microwave-sustained plasma jets at atmospheric pressure are found to be much smaller than the value expected from the standard high-pressure single probe theory providing an over estimation of electron temperatures. By assuming that the single probe characteristic behaves as an asymmetric double probe when the electron to ion saturation current ratio is reduced, the whole characteristics may be fitted and significantly lower electron temperatures may be derived. In this study, asymmetric double probe theory for collisional plasmas is developed and employed to microwave-sustained helium plasma jets in order to estimate the plasma parameters (electron temperature and plasma density) at atmospheric pressure avoiding the overestimation of electron temperature.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Spectroscopic and probe measurements of the electron temperature in the plasma of a pulse-periodic microwave discharge in argon

A pulse-periodic 2.45-GHz electron-cyclotron resonance plasma source on the basis of a permanent- magnet mirror trap has been constructed and tested. Variations in the discharge parameters and the electron temperature of argon plasma have been investigated in the argon pressure range of 1 × 10{sup –4} to 4 × 10{sup –3} Torr at a net pulsed input microwave power of up to 600 W. The plasma electron temperature in the above ranges of gas pressures and input powers has been measured by a Langmuir probe and determined using optical emission spectroscopy (OES) from the intensity ratios of spectral lines. The OES results agree qualitatively and quantitatively with the data obtained using the double probe.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗