Search NASA⌕ Search

SEARCH · Search NASA

Results for “MIMS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

InGaAs/InP Monolithic Interconnected Modules (MIM) for Thermophotovoltaic Applications

There has been a traditional trade-off in thermophotovoltaic (TPV) energy conversion development between systems efficiency and power density. This trade-off originates from the use of front surface spectral controls such as selective emitters and various types of filters. A monolithic interconnected module (MIM) structure has been developed which allows for both high power densities and high system efficiencies. The MIM device consists of many individual indium gallium arsenide (InGaAs) devices series -connected on a single semi-insulating indium phosphide (InP) substrate. The MIMs are exposed to the entire emitter output, thereby maximizing output power density. An infrared (IR) reflector placed on the rear surface of the substrate returns the unused portion of the emitter output spectrum back to the emitter for recycling, thereby providing for high system efficiencies. Initial MIM development has focused on a 1 sq cm device consisting of eight series interconnected cells. MIM devices, produced from 0,74 eV InGAAs, have demonstrated V(sub infinity) = 3.23 volts, J(sub sc) = 70 mA/sq cm and a fill factor of 66% under flashlamp testing. Infrared (IR) reflectance measurement (less than 2 microns) of these devices indicate a reflectivity of less than 82%. MIM devices produced from 0.55 eV InGaAs have also been den=monstrated. In addition, conventional p/n InGaAs devices with record efficiencies (11.7% AM1) have been demonstrated.

Wilt, David M.↗

Monolithic Interconnected Modules (MIMs) for Thermophotovoltaic Energy Conversion

Monolithic Interconnected Modules (MIM) are under development for thermophotovoltaic (TPV) energy conversion applications. MIM devices are typified by series-interconnected photovoltaic cells on a common, semi-insulating substrate and generally include rear-surface infrared (IR) reflectors. The MIM architecture is being implemented in InGaAsSb materials without semi-insulating substrates through the development of alternative isolation methodologies. Motivations for developing the MIM structure include: reduced resistive losses, higher output power density than for systems utilizing front surface spectral control, improved thermal coupling and ultimately higher system efficiency. Numerous design and material changes have been investigated since the introduction of the MIM concept in 1994. These developments as well as the current design strategies are addressed.

Wilt, David↗

Effects of G-Jitter on Interfacial Dynamics of Two Miscible Liquids: Application of MIM

We designed an experiment to examine the effects of g-jitter on mixing of two miscible liquids using the Microgravity Vibration Isolation Mount (MIM). The global bifurcation of the interface was observed with the MIM operating alternatively to either transmit the g-jitter, isolate from the g-jitter or to provide controlled vibration levels with well defined amplitude and frequency content. With the MIM in isolation mode, the interface remains stationary indicating buoyancy induced convection is negligibly small such that mixing occurs via intrinsic mass diffusion without the masking effect of vibration driven convection. Analytical and computational results are in agreement with the experimental findings. Operation of the MIM in forced mode with conditions typical of g-jitter shows that vibration induced convective flows can excite instability mechanisms such as Kelvin-Helmholtz to generate large amplitude quasi-stationary waves oriented vertically for various cases with Stokes-Reynolds number in the range of 0.003 to 0.5. The two and four mode quasi-stationary waves are also predicted with a mathematical model. Though unplanned, the effect of a primary thruster filing was captured and shown to cause a catastrophic bifurcation, enhancing local mass transport. In light of the findings, experiments planned for the International Space Station should consider the potential effects of g-jitter.

Duval, Walter M. B.↗

n/p/n Tunnel Junction InGaAs Monolithic Interconnected Module (MIM)

The Monolithic Interconnected Module (MIM), originally introduced at the First NREL thermophotovoltaic (TPV) conference, consists of low-bandgap indium gallium arsenide (InGaAs) photovoltaic devices, series interconnected on a common semi-insulating indium phosphide (inP) substrate. An infrared reflector is deposited on the back surface of the substrate to reflect photons, which were not absorbed in the first pass through the structure. The single largest optical loss in the current device occurs int he heavily doped p-type emitter. A new MIM design (pat.pend.) has been developed which flips the polarity of the conventional MIM cell (i.e., n/p rather than p/n), eliminating the need for the high conductivity p-type emitter. The p-type base of the cell is connected to the n-type lateral conduction layer through a thin InGaAs tunnel junction. 0.58 eV and 0.74 eV InGaAs devices have demonstrated reflectances above 90% for wavelengths beyond the bandgap (greater than 95% for unprocessed structures). Electrical measurements indicate minimal voltage drops across the tunnel junction (less than mV/junction under 1200K-blackbody illumnination) and fill factors that are above 70% at current densities (J(sub sc)) above 8 Angstroms per square centimeters for the 0.74eV devices.

Wilt, David M.↗

Optimal Controller Design for the Microgravity Isolation Mount (MIM)

H2 controllers, when designed using an appropriate design model and carefully chosen frequency weightings, appear to provide robust performance and robust stability for Microgravity Isolation Mount (MIM). The STS-85 flight data will be used to evaluate the H2 controllers' performance on the actual hardware under working conditions. Next, full-order H-infinity controllers will be developed, as an intermediate step, in order to determine appropriate H-infinity performance weights for use in the mixed-norm design. Finally the basic procedure outlined above will be used to develop fixed-order mixed-norm controllers for MIM.

Hampton, R. David↗

Fluids and Materials Science Studies Utilizing the Microgravity-vibration Isolation Mount (MIM)

Canada's Microgravity Sciences Program (MSP) is the smallest program of the ISS partners and so can participate in only a few, highly focused projects in order to make a scientific and technological impact. One focused project involves determining the effect of accelerations (g-jitter) on scientific measurements in a microgravity environment utilizing the Microgravity-vibration Isolation Mount (MIM). Many experiments share the common characteristic of having a fluid stage in their process. The quality of the experimental measurements have been expected to be affected by g-jitters which has lead the ISS program to include specifications to limit the level of acceleration allowed on a subset of experimental racks. From finite element analysis (FEM), the ISS structure will not be able to meet the acceleration specifications. Therefore, isolation systems are necessary. Fluid science results and materials science results show significant sensitivity to g-jitter. The work done to date should be viewed only as a first look at the issue of g-jitter sensitivity. The work should continue with high priority such that the international science community and the ISS program can address the requirement and settle on an agreed to overall approach as soon as possible.

Herring, Rodney↗

Medical Information Management System (MIMS): An automated hospital information system

An automated hospital information system that handles all data related to patient-care activities is described. The description is designed to serve as a manual for potential users, nontechnical medical personnel who may use the system. Examples of the system's operation, commentary on the examples, and a complete listing of the system program are included.

Alterescu, S.↗

Medical Information Management System (MIMS): A generalized interactive information system

An interactive information system is described. It is a general purpose, free format system which offers immediate assistance where manipulation of large data bases is required. The medical area is a prime area of application. Examples of the system's operation, commentary on the examples, and a complete listing of the system program are included.

Alterescu, S.↗

A Multi-Faceted Approach to Demonstrating Multi-Functional Integrated Medical Devices to Advance Earth-Independent Medical Operations

INTRODUCTION TO MIM DEVICES Multi-functional Integrated Medical (MIM) devices conveniently incorporate multiple medical system capabilities within one device. The NASA Exploration Medical Integrated Product Team (XM-IPT) sponsored a market survey and trade study which identified the Tempus ProTM and the LifeBot 10® as the MIM devices that best met the evaluation criteria of the trade study. The Tempus ProTM (Remote Diagnostic Technologies, Ltd., Philips Corp., Farnborough, UK) and LifeBot 10® (LifeBot Health, Chicago, IL) both provide vital sign measurements such as blood pressure, electrocardiograms, heart rate, end tidal CO2, respiration rate, pulse oximetry and temperature along with ultrasound imaging. A video laryngoscopy capability is unique to the Tempus ProTM, while the LifeBot 10® supports connectivity with a digital stethoscope, otoscope, eye exam camera, and dermatoscope. Both devices include procedural guidance capabilities and have various data transmission and report generation features. TECHNOLOGY DEMONSTRATIONS NASA’s exploration-class missions will have severe resource constraints, long return trip durations, significant communication delays, and limited resupply opportunities. The medical systems of these missions will need to fit within an Earth-Independent Medical Operations (EIMO) construct. Key features of an EIMO medical system include: 1) technologies that support the prevention, diagnosis, and treatment of spaceflight medical events; 2) components that meet mass, volume, power and crew time/training constraints; 3) consideration of the medical skill level of the astronaut caregiver; 4) collection, storage and analysis of medical data within a central data architecture; and 5) incorporation of appropriate guidance and support tools that allow crew autonomy. Evaluations are underway to determine if it will be beneficial to include MIM devices within exploration medical systems by conducting a series of planned technical demonstrations. Exploration Atmosphere Chamber studies are being performed to determine MIM functionality in a high oxygen concentration atmosphere. A side-by-side comparison of the Tempus ProTM and LifeBot 10® will be performed during ground-based demonstrations. Use of the MIM devices within an EIMO medical scenario simulation will be practiced during ground-based demonstrations in preparation for International Space Station (ISS) demonstrations of the MIM device. These various demonstrations are designed to gather evidence for or against the inclusion of MIM devices within an EIMO medical system. EXPECTED DEMONSTRATION OUTCOMES Information will be gained about the feasibility, benefits, and challenges of using a multifunctional, all-in-one, medical device for medical diagnosis. Information will also be collected about performance differences as available ground support decreases. Gaining this understanding will allow for further development of exploration medical system capabilities, which take the EIMO construct into consideration.

B. E. Lewandowski↗

Custom Integration of Multiple Medical Functionalities

INTRODUCTION: Previous spaceflight experience and results from probabilistic risk assessment of spaceflight medical risk have highlighted the need for vital sign measurements, medical scopes, and clinical imaging tools for managing medical conditions during spaceflight. The Human Research Program’s Exploration Medical Capability (ExMC) Element and the Mars Campaign Office’s Exploration Medical Integrated Product Team (XMIPT) have performed ground-based evaluations of two Commercial-off-the-Shelf (COTS) Multi-functional Integrated Medical (MIM) devices, which integrate various medical capabilities together in one device. The key findings from these evaluations are presented in a complementary presentation, leaving this presentation to focus on forward recommendations for customized integration of multiple medical functionalities. KEY COMPONENTS: The key features of a custom integration of multiple medical functionalities includes devices and capabilities that optimally reduce medical risk. The COTS MIM devices incorporated functionality for best supporting Earth-based, emergency, pre-hospital care. Our custom integration will use probabilistic risk assessment tools, such as the Medical Extensible Dynamic Probabilistic Risk Assessment Tool (MEDPRAT), to determine the optimal functionality to include based on medical risk minimization. An additional feature of custom integration includes the ability to adapt to different requirements within different vehicles and/or missions. The COTS MIM devices store data in patient specific records, however, the format of the records is not modifiable, and data are not easily transferred from the MIM device to a central data architecture outside of the manufacturer’s established system. Our concept for custom integration will use devices that have an open application programming interface, which can easily connect to independent data architectures and third-party visualization software. The ultrasound capabilities included within the COTS MIM devices did not satisfy many of the Artemis Research and Operations Working Group’s ultrasound functional needs, and therefore, incorporation of higher quality ultrasound capabilities within a customized integration will be beneficial. The COTS MIM devices included minimal procedural guidance and clinical decision support tools. Supplemental tools of this type would need to be supplied along with the COTS MIM devices if they were to be used operationally, so another advantage of customization is the ability to integrate these support tools along with the medical functionality, for a more streamlined user experience. CONCLUSION: Investigation of a customized integration of medical functionality provides a method for further understanding the needs of a long-term exploration spaceflight medical system. The crew members of these exploration missions will need to operate more and more independently from Earth-based ground support. Therefore, having an optimized, streamlined medical system, which contains the functionality and supporting information needed, while remaining within mission and vehicle constraints, will help to maintain crew health and performance, which is necessary for achieving high levels of mission success.

B E Lewandowski↗

Electrical and Optical Performance Characteristics of 0.74-eV p/n InGaAs Monolithic Interconnected Modules

There has been a traditional trade-off in thermophotovoltaic (TPV) energy conversion development between system efficiency and power density. This trade-off originates from the use of front surface spectral controls such as selective emitters and various types of filters. A monolithic interconnected module (MIM) structure has been developed which allows for both high power densities and high system efficiencies. The MIM device consists of many individual indium gallium arsenide (InGaAs) cells series-connected on a single semi-insulating indium phosphide (InP) substrate. The MIM is exposed to the entire emitter output, thereby maximizing output power density. An infrared (IR) reflector placed on the rear surface of the substrate returns the unused portion of the emitter output spectrum back to the emitter for recycling, thereby providing for high system efficiencies. Initial MIM development has focused on a 1 sq cm device consisting of eight (8) series interconnected cells. MIM devices, produced from 0.74-eV InGaAs, have demonstrated V(sub oc) = 3.2 volts, J(sub sc) = 70 mA/sq cm, and a fill factor of 66% under flashlamp testing. Infrared (IR) reflectance measurements (greater than 2 micron) of these devices indicate a reflectivity of greater than 82%. MIM devices produced from 0.55-eV InGaAs have also been demonstrated. In addition, conventional p/n InGaAs devices with record efficiencies (11.7% AM0) have been demonstrated.

Wilt, David M.↗

Electrical and Optical Performance Characteristics of p/n InGaAs Monolithic Interconnected Modules

There has been a traditional trade-off in ThermoPhotoVoltaic (TPV) energy conversion development between system efficiency and power density. This trade-off originates from the use of front surface spectral controls such as selective emitters and various types of filters. A Monolithic Interconnected Module (MIM) structure has been developed which allows for both high power densities and high system efficiencies. The MIM device consists of many individual Indium Gallium Arsenide (InGaAs) devices series-connected on a single semi-insulating Indium Phosphide (InP) substrate. The MIMs are exposed to the entire emitter output, thereby maximizing output power density. An InfraRed (IR) reflector placed on the rear surface of the substrate returns the unused portion of the emitter output spectrum back to the emitter for recycling, thereby providing for high system efficiencies. Initial MIM development has focused on a 1 sq cm device consisting of eight (8) series interconnected cells. MIM devices, produced from 0.74eV InGaAs, have demonstrated V(sub infinity) = 3.2 volts, J(sub sc) = 70 mA/sq cm and a fill factor of 66% under flashlamp testing. IR reflectance measurements (greater than 2 microns) of these devices indicate a reflectivity of greater than 82%. MIM devices produced from 0.55 eV InGaAs have also been demonstrated. In addition, conventional p/n InGaAs devices with record efficiencies (11.7% AM0) have been demonstrated.

Wilt, David M.↗

Thin-film chemical sensors based on electron tunneling

The physical mechanisms underlying a novel chemical sensor based on electron tunneling in metal-insulator-metal (MIM) tunnel junctions were studied. Chemical sensors based on electron tunneling were shown to be sensitive to a variety of substances that include iodine, mercury, bismuth, ethylenedibromide, and ethylenedichloride. A sensitivity of 13 parts per billion of iodine dissolved in hexane was demonstrated. The physical mechanisms involved in the chemical sensitivity of these devices were determined to be the chemical alteration of the surface electronic structure of the top metal electrode in the MIM structure. In addition, electroreflectance spectroscopy (ERS) was studied as a complementary surface-sensitive technique. ERS was shown to be sensitive to both iodine and mercury. Electrolyte electroreflectance and solid-state MIM electroreflectance revealed qualitatively the same chemical response. A modified thin-film structure was also studied in which a chemically active layer was introduced at the top Metal-Insulator interface of the MIM devices. Cobalt phthalocyanine was used for the chemically active layer in this study. Devices modified in this way were shown to be sensitive to iodine and nitrogen dioxide. The chemical sensitivity of the modified structure was due to conductance changes in the active layer.

Khanna, S. K.↗

Inverted Three-Junction Tandem Thermophotovoltaic Modules

An InGaAs-based three-junction (3J) tandem thermophotovoltaic (TPV) cell has been investigated to utilize more of the blackbody spectrum (from a 1,100 C general purpose heat source GPHS) efficiently. The tandem consists of three vertically stacked subcells, a 0.74-eV InGaAs cell, a 0.6- eV InGaAs cell, and a 0.55-eV InGaAs cell, as well as two interconnecting tunnel junctions. A greater than 20% TPV system efficiency was achieved by another group with a 1,040 C blackbody using a single-bandgap 0.6- eV InGaAs cell MIM (monolithic interconnected module) (30 lateral junctions) that delivered about 12 V/30 or 0.4 V/junction. It is expected that a three-bandgap tandem MIM will eventually have about 3 this voltage (1.15 V) and about half the current. A 4 A/cm2 would be generated by a single-bandgap 0.6-V InGaAs MIM, as opposed to the 2 A/cm2 available from the same spectrum when split among the three series-connected junctions in the tandem stack. This would then be about a 50% increase (3xVoc, 0.5xIsc) in output power if the proposed tandem replaced the single- bandgap MIM. The advantage of the innovation, if successful, would be a 50% increase in power conversion efficiency from radioisotope heat sources using existing thermophotovoltaics. Up to 50% more power would be generated for radioisotope GPHS deep space missions. This type of InGaAs multijunction stack could be used with terrestrial concentrator solar cells to increase efficiency from 41 to 45% or more.

Wojtczuk, Steven↗

The Microgravity Vibration Isolation Mount: A Dynamic Model for Optimal Controller Design

Vibration acceleration levels on large space platforms exceed the requirements of many space experiments. The Microgravity Vibration Isolation Mount (MIM) was built by the Canadian Space Agency to attenuate these disturbances to acceptable levels, and has been operational on the Russian Space Station Mir since May 1996. It has demonstrated good isolation performance and has supported several materials science experiments. The MIM uses Lorentz (voice-coil) magnetic actuators to levitate and isolate payloads at the individual experiment/sub-experiment (versus rack) level. Payload acceleration, relative position, and relative orientation (Euler-parameter) measurements are fed to a state-space controller. The controller, in turn, determines the actuator currents needed for effective experiment isolation. This paper presents the development of an algebraic, state-space model of the MIM, in a form suitable for optimal controller design.

Hampton, R. David↗

The Microgravity Isolation Mount: A Linearized State-Space Model a la Newton and Kane

Vibration acceleration levels on large space platforms exceed the requirements of many space experiments. The Microgravity Vibration Isolation Mount (MIM) was built by the Canadian Space Agency to attenuate these disturbances to acceptable levels, and has been operational on the Russian Space Station Mir since May 1996. It has demonstrated good isolation performance and has supported several materials science experiments. The MIM uses Lorentz (voice-coil) magnetic actuators to levitate and isolate payloads at the individual experiment/sub-experiment (versus rack) level. Payload acceleration, relative position, and relative orientation (Euler-parameter) measurements are fed to a state-space controller. The controller, in turn, determines the actuator currents needed for effective experiment isolation. This paper presents the development of an algebraic, state-space model of the MIM, in a form suitable for optimal controller design. The equations are first derived using Newton's Second Law directly; then a second derivation (i.e., validation) of the same equations is provided, using Kane's approach.

Hampton, R. David↗

A Solar Thermophotovoltaic Electric Generator for Remote Power Applications

We have successfully demonstrated that a solar thermophotovoltaic (TPV) system with a SiC graybody emitter and the monolithic interconnected module device technology can be realized. A custom-designed solar cavity was made to house the SiC emitter and the Monolithic Integrated Module (MIM) strings for testing in a Stirling dish solar concentrator. Five 1x1-cm MIMs, with a bandgap of 0.74 eV, were mounted on a specially designed water-cooled heatsink and were electrically connected in series to form a string. Two such strings were fabricated and tested, as well as high-performance 2x2-cm MIMs with a bandgap of 0.74 eV. Very high output power density values between 0.82 and 0.90 W/ square cm were observed for an average emitter temperature of 1501 K.

Fatemi, Navid S.↗