Search NASASearch

SEARCH · Search NASA

Results for “MIXER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Effects of gamma, electron beam, and X-ray irradiation on the plastic components of a universal bone cement mixer medical device

Due to market and regulatory pressures, many healthcare manufacturers are considering alternatives to cobalt-60 gamma radiation, including accelerator-based electron beam (E-beam) and X-ray radiation for product sterilization. In this work, the effects of irradiation on a representative medical product, comprised of eight distinct polymer materials, were directly compared for three radiation technologies – cobalt-60 gamma, E-beam, and X-ray – at four dose levels (15, 25, 50, and 70 kGy). The objective was to determine how radiation effects (deleterious or beneficial) are influenced by source and dose level, with the specific goal of determining whether E-beam radiation and/or X-ray radiation could be viable alternatives to gamma radiation for device sterilization. Here, the specific product considered is a single-use medical device for orthopedic surgery, the Stryker Instruments MixeVac III bone cement mixer, which is currently sterilized using gamma radiation from cobalt-60 sources. Following ASTM International standards and input from the manufacturer, we characterized the effects of the three radiation sources on product functionality as well as on the mechanical and optical properties of the constituent polymers. Results indicate that although measurable differences in properties between the standard gamma irradiated materials and the alternative E-beam and X-ray irradiated materials were observed, those differences were small. Statistically significant differences were noted in the case of yellowness index for polyvinyl chloride, high-density polyethylene, and polycarbonate, and in the case of tensile elongation at break for high impact polystyrene and polyvinyl chloride. In general, the results of this study support the viability of E-beam and X-ray radiation as alternative options to cobalt-60 gamma radiation for sterilization of Stryker single-use universal bone cement mixer medical devices.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND

Fast jet tagging with MLP-Mixers on FPGAs

We explore the innovative use of MLP-Mixer models for real-time jet tagging and establish their feasibility on resource-constrained hardware like FPGAs. MLP-Mixers excel in processing sequences of jet constituents, achieving state-of-the-art performance on datasets mimicking Large Hadron Collider conditions. By using advanced optimization techniques such as High-Granularity Quantization and Distributed Arithmetic, we achieve unprecedented efficiency. These models match or surpass the accuracy of previous architectures, reduce hardware resource usage by up to 97%, double the throughput, and half the latency. Additionally, non-permutation-invariant architectures enable smart feature prioritization and efficient FPGA deployment, setting a new benchmark for machine learning in real-time data processing at particle colliders.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND

In‐situ Analysis of Paste Properties in Resonant Acoustic Mixers for Quality Monitoring

Formulation control is key to achieving consistent target properties of energetic materials, as feedstock variations and slight deviations in the ratios of different ingredients can have major effects on final product properties, particularly in dense pastes with high particle loading >65 vol.%. In large‐scale operations, it is imperative to either correct or remove batches of material that perform outside baseline property specifications as early as possible to avoid unnecessary processing of suboptimal material. Quality monitoring is the practice of measuring material properties during processing using process analytical technologies as opposed to only testing the properties of the final product; it is a key principle in the quality‐by‐design frameworks used for designing formulations and manufacturing processes. Herein, a process analytical technology method for correlating material properties of dense pastes directly after mixing in a Resonant Acoustic Mixer to motor data is developed and used to detect differences in the particle content of dense paste formulations. This method was also capable of detecting variations in powder feedstock properties, such as particle packing efficiency, and is sensitive enough to detect changes of 2 wt.% in the total solids content of the formulation. The techniques presented herein show excellent promise for use as a process analytical technology capable of quantifying formulation effects on material movement modes during resonant acoustic mixing.

Materials science

Gamma, electron beam and X-ray irradiation effects on polymers in an advanced bone cement mixer device

The medical device industry has been investigating ways to increase the use of alternatives to cobalt-60 gamma radiation and ethylene-oxide gas sterilization, such as electron beam (E-beam) and X-ray radiation, due to regulatory and market pressures. One impediment to switching to E-beam or X-ray technology for sterilization is the lack of data on the effects of these radiation sources on medical device polymers. To provide such data this work considers irradiation and testing of a common single-use medical bone cement mixing system, the Stryker Advanced Cement Mixer (ACM®), that is composed of seven polymer materials. The ACM® devices considered here were processed to sterilization-relevant doses (15, 25, 50, and 70 kGy) using three radiation technologies: gamma, E-beam, and X-ray. The system and its polymer components were tested for product functionality, as well as mechanical and visual properties to determine how exposure effects may be influenced by radiation technology and dose level. We found that although there were instances of statistically significant differences in effects between the gamma-irradiated products and those irradiated with E-beam and X-ray, those effects were negligible in terms of retained functionality of the product and retained mechanical properties of the polymer components. Overall, results of this study demonstrate that, for of the effects studied, E-beam and X-ray are viable alternatives to cobalt-60 gamma radiation for sterilization of the polymer-based device investigated.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS

Linear Quantum Coupler for Clean Bosonic Control

Quantum computing with superconducting circuits relies on high-fidelity driven nonlinear processes. An ideal quantum nonlinearity would selectively activate desired coherent processes at high strength, without activating parasitic mixing products or introducing additional decoherence. The wide bandwidth of the Josephson nonlinearity makes this difficult, with undesired drive-induced transitions and decoherence limiting qubit readout, gates, couplers, and amplifiers. Significant strides have recently been made into building better “quantum mixers,” with promise being shown by Kerr-free three-wave mixers that suppress driven frequency shifts, and balanced quantum mixers that explicitly forbid a significant fraction of parasitic processes. We propose a novel mixer that combines both these strengths, with engineered selection rules that make it essentially linear (not just Kerr-free) when idle, and activate clean parametric processes even when driven at high strength. Furthermore, its ideal Hamiltonian is simple to analyze analytically, and we show that this ideal behavior is first-order insensitive to dominant experimental imperfections. We expect this mixer to allow significant advances in high-𝑄 control, readout, and amplification.

Quantum circuits

Biased degenerate ground-state sampling of small Ising models with converged quantum approximate optimization algorithm

The quantum alternating operator ansatz, a generalization of the quantum approximate optimization algorithm (QAOA), is a quantum algorithm used for approximately solving combinatorial optimization problems. QAOA typically uses the transverse field mixer as the driving Hamiltonian. One of the interesting properties of the transverse field driving Hamiltonian is that it results in nonuniform sampling of degenerate ground states of optimization problems. In this study, we numerically examine the fair sampling properties of the transverse field mixer QAOA, and Grover mixer QAOA (GM-QAOA), which provides theoretical guarantees of fair sampling of degenerate optimal solutions, up to a large enough p such that the mean expectation value converges to an optimal approximation ratio of 1. This comparison is performed with high-quality heuristically computed, but not necessarily optimal, QAOA angles, which give strictly monotonically improving solution quality as p increases. These angles are computed using the Julia based numerical simulation software JuliQAOA. Fair sampling of degenerate ground states is quantified using the Shannon entropy of the ground-state amplitudes distribution. The fair sampling properties are reported on several quantum signature Hamiltonians from previous quantum annealing fair sampling studies. Small random fully connected spin glasses are shown, which exhibit exponential suppression of some degenerate ground states with transverse field mixer QAOA. The transverse field mixer QAOA simulations show that some problem instances clearly saturate the Shannon entropy of 0 with a maximally biased distribution that occurs when the learning converges to an approximation ratio of 1 while other problem instances never deviate from a maximum Shannon entropy (uniform distribution) at any p step. Published by the American Physical Society 2025

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC

Saltstone Paddles and Augers Materials of Construction Study

The Saltstone Production Facility (SPF) uses a 10-inch READCO continuous, co-rotating twin-screw mixer to mix the dry premix with the low-level radioactive waste (LLW) salt solution to produce fresh saltstone grout. The paddles and augers within the mixer degrade via erosion in the region where the salt solution is introduced into the mixer. After the paddles/augers erode to a point where the throughput impacts operations, the mixer is disassembled, the effected paddles/augers are replaced, and the mixer is reassembled. Saltstone Engineering indicated that this effort requires an approximately three-week outage. The objective of this task is to assess alternative materials of construction (MOCs) that will provide better erosion characteristics and decrease the frequency in which the paddles and augers need replacement. Previous Astralloy V studies looked only at Charpy Impact and Rockwell Hardness Testing. Each of these will be examined for different alloys as well as Miller Testing (abrasion to determine wear) which will provide a good assessment of an alloy’s erosion/wear characteristics. The following facts concerning the current and proposed alloys for Saltstone Paddles and Augers are provided in this report. • Current Astralloy V material and alloy E52100 had the most favorable Miller Testing Results. • Charpy Impact Testing did not correlate with Miller Testing Results. • Hardness Testing correlated with Miller Testing results meaning that higher hardness will provide more favorable wear resistance. • Further investigation of E52100 and various tool grade steels is recommended for achieving wear resistant properties.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W

Thermokinetic mixing compounding for polymer composites – a comprehensive review

High-speed thermokinetic mixers (K-mixers) represent an advanced compounding technology that employs intense shear and friction to convert kinetic energy directly into thermal energy. This mechanism enables rapid mixing cycles, often under one minute, facilitating exceptional filler dispersion while minimizing the material’s thermal history. This is particularly effective for compounding challenging materials, including heat-sensitive biopolymers, wet filler feedstocks, and nanofillers prone to agglomeration. As the first comprehensive review of this technology, this article synthesizes the fundamental principles of thermokinetic mixing (K-mixing) and surveys recent advances in polymer composite fabrication. We contrast the working principles of K-mixers with conventional twin-screw extrusion, highlighting distinct advantages in dispersing nanoscale fillers, exfoliating layered materials, and processing wet cellulosic feedstocks and ultra-high filler loadings (e.g., 85 wt%). Furthermore, strategies to optimize filler–matrix interfacial bonding under rapid-processing constraints, such as the kinetic selection of compatibilizers and fiber surface treatments, are evaluated. Finally, we analyze key structure-processing-property relationships and outline future directions in scaling up, reactive processing, and hybrid material development.

Zhang, Xuefeng [University of Maine]

Lightwave-electronic harmonic frequency mixing

Electronic frequency mixers are fundamental building blocks of electronic systems. Harmonic frequency mixing in particular enables broadband electromagnetic signal analysis across octaves of spectrum using a single local oscillator. However, conventional harmonic frequency mixers do not operate beyond hundreds of gigahertz to a few terahertz. If extended to the petahertz scale in a compact and scalable form, harmonic mixers would enable field-resolved optical signal analysis spanning octaves of spectra in a monolithic device without the need for frequency conversion using nonlinear crystals. Here, we demonstrate lightwave-electronic harmonic frequency mixing beyond 0.350 PHz using plasmonic nanoantennas. We demonstrate that the mixing process enables complete, field-resolved detection of spectral content far outside that of the local oscillator, greatly extending the range of detectable frequencies compared to conventional heterodyning techniques. Our work has important implications for applications where optical signals of interest exhibit coherent femtosecond-scale dynamics spanning multiple harmonics.

Science & Technology - Other Topics

High Linearity RF Circuits in CMOS Platforms (CRADA Final Report)

The goal of this CRADA was to understand high linearity silicon-on-insulator (SOI) radio frequency switches. The first direction investigated was high linearity RF mixers as these components are composed of a network of switches. During the course of the investigation, it was determined that while the SOI RF switches were effective in the application in mixers and produced state of the art performance, the use of SOI for mixers is not economically feasible because the technology only worked with advanced CMOS nodes <65nm which can have an NRE cost (from lithography masks) in excess of $\$$500,000.

42 ENGINEERING

Purification of U from U-10Mo scrap generated during the fabrication of high performance research reactor fuel

A low enriched U-Mo alloy fuel is under development to replace highly enriched U fuels currently used in United States high performance research reactors. The alloy casting and fuel fabrication processes will generate scrap streams containing low enriched U (LEU) which must be recovered. Solvent extraction processes were designed using the Argonne Model for Universal Solvent Extraction (AMUSE) to purify solutions containing 20 and 50 g/L U. The feed for the solvent extraction processes was prepared from solutions generated from the dissolution of U-10Mo-Zr foils and U-10Mo-Zr-Al mini-plates. The U purification processes were demonstrated using two, 16-stage banks of miniature mixer-settlers. The solvent extraction experiments demonstrated that all design objectives for the U purification processes could be met. The U recovery in the product stream for each flowsheet was ≥99.9%. The flowsheet demonstrations also showed that the purity of the U Product will meet the requirements of the ASTM International C1462-21 specification for LEU metal enriched to less than 20% 235 U. In conclusion, the AMUSE modeling for both flowsheet demonstrations was validated by comparing predicted and measured concentrations of U, Mo, and Zr in the exit streams and stage samples at steady-state conditions in the mixer-settlers.

modified PUREX process

DIRECT RF SAMPLING BASED LLRF CONTROL SYSTEM FOR C-BAND LINEAR ACCELERATOR

Low Level RF (LLRF) control systems of linear accel- erators (LINACs) are typically implemented with hetero- dyne based architectures, which have complex analog RF mixers for up and down conversion. The Gen 3 Radio Fre- quency System-on-Chip (RFSoC) device from AMD Xilinx integrates data converters with maximum RF frequency of 6 GHz. This enables direct RF sampling of C-band LLRF signal typically operated at 5.712 GHz without any analogue mixers, which can significantly simplify the system architec- ture. The data converters sample RF signals in higher order Nyquist zones and then up or down convert digitally by the integrated data path in RFSoC. The closed-loop feedback control firmware implemented in FPGA integrated in RF- SoC can process the base-band signal from the ADC data path and calculate the updated phase and amplitude to be up- mixed by the DAC data path. We have developed a C-band LLRF control RFSoC platform with direct RF sampling, which targets Cool Copper Collider (𝐶3) and other C or S band LINAC research and development projects. In this paper, the architecture of the platform will be described. We have optimized the configuration of the data converter and characterized performance of them with RF pulses. The test results for some of the key performance parameters for the LLRF platform with our custom solid-state amplifier, such as phase and amplitude stability, will be discussed in this paper.

Liu, C

Microchannel-based Membrane-less Extraction of Li from Unconventional Lithium Sources & the Separation of REE

This final report provides an overview of the Project's entire duration, covering July 1, 2021 to December 31, 2023. It primarily focuses on the achievements, technological developments, and unique challenges the team faced while working on separating and extracting Lithium from produced waters. The project's primary aim was to create an integrated, high-throughput, membrane-less, and modular microfluidic platform that could extract Lithium from unconventional sources. We have successfully met all goals and milestones envisioned in the SOPO document. The most critical primary milestones, including the Go-No-Go milestone (refer to the Gantt chart in the Appendices), were successfully accomplished. We demonstrated phase separation (>90%) and extraction (>85%) performance in the MPSE using synthetic, and representative produced water composition feed at 50 ml/min total flow through MPSE 36. We have also performed a parametric study of the MPSE operations, beyond the scope of SOPO, exploring operating conditions of current and broader interest. The extended investigation of operational parameters is concurrent with our efforts to seek further development of the MPSE technology beyond the scope of the Project. Along these lines of development, we have made efforts to be responsive to DOE calls for technological developments of other types of resources (beyond PW) for the recovery of Critical Materials and higher TRL development (beyond TRL 4). During the work on this Project, we developed and implemented three innovative technical approaches that emerged from our efforts to successfully meet the Project milestones. The innovative & original technical approaches developed and implemented in this Project are now the contributions to process engineering that could be clearly credited to the Project. First, Convergent Design Approach is a comprehensive feedforward & feedback loop of four design phases: i) design for functionality, ii) design for manufacturing, iii) design for sustainability, and iv) design for market. Next was Process Intensification. A major aim of this Project was to create an innovative phase separation & extraction microscale-based technology for Li separation – thus the words microchannel-based in the Project title. A microscale-based technology is intrinsically in the center of the Process Intensification domain as defined by its unique principles. Therefore, Process Intensification was implicitly envisioned in the Project’s SOPO. Lastly, Time Scale Analysis is a novel tool for discovering the needs and directions of Process Intensification implementations in any process technology. This Project is fully credited for developing and implementing the three novel technical approaches mentioned above. These are general contributions to process engineering that emerged from this Project. Beyond the original SOPO scope, the OSU-U.Pitt research group utilized a Convergent Design methodology, integrating first-principles mathematical modeling with experimental validation on the Minimum Development Vehicle. By creating these Digital Twins, the team rapidly assessed manufacturing iterations to support TEA analysis. This framework further enabled the development of advanced Surface Modification Techniques, where hydrophobic and oleophobic coating strategies were optimized via Digital Twin tools and validated through rigorous 100-hour longevity testing. TEA Analysis: The closing efforts of this Project were focused on the TEA analysis. TEA analysis had two primary functions: i) enabling critical assessments of design variations withing 10 the Concurrent Design Approach, thus enabling evolution of the MPSE design to reach faster- better-cheaper alternatives; and ii) to create a bridge between the accomplishments of this Project and future projects of higher TRL, beyond TRL 6 level. It is important to note that the TEA model created in the Project stirred the technological solutions for the recovery of critical materials toward a vision of a very profitable modular plant that has unique zero-waste water discharge signature. More importantly, thanks to our experimental performance data and conservative assumptions, the TEA model predicts minimal technological and investment risks. Low cost of a modular unit of a nominal capacity of [1000 tons of Li 2 CO 3 /year] positions the MPSE based technology within the reach of community investors, thus offering a paradigm shift in the development of critical technologies. The project successfully navigated two primary challenges: solvent selection and manufacturing adaptation. Restricted by the SOPO to existing literature for lithium recovery, the team identified a critical need for a "material excellence program" to develop next-generation solvents, eventually concluding with a preliminary investigation into promising Ionic Liquids (ILs). Simultaneously, COVID-19 supply chain disruptions forced a pivot from traditional manufacturing to advanced additive methods at ATAMI-OSU. By transitioning from stainless steel to 3D-printed polymer substrates, the team achieved a transformative three-order-of- magnitude reduction in manufacturing costs and compressed prototyping timelines from several months to just two days. The MPSE technology offers significant energy, environmental, and economic advantages by overcoming the traditional bottlenecks of phase-separation hardware and contactor size. Unlike conventional mixer-settlers or membrane-based systems, MPSE operates without moving parts or fouling-prone membranes, achieving robust performance even with challenging, viscous, or particulate-heavy feeds. Key performance metrics include an energy intensity reduction of 5–50x (3–40 kJ/m 3 ) compared to incumbent technologies and a dramatic reduction of processing time to under 60 seconds, which drastically reduces the physical plant footprint. These technical efficiencies translate into superior economic outcomes; for a 100 t/year Li 2 CO 3 facility, implementing MPSE is projected to nearly halve contactor CAPEX (from $\$$6.08M to $\$$3.01M) and significantly increase the project's Net Present Value (NPV), derisking new investment and enabling distributed critical-mineral processing configurations. The commercialization of MPSE technology is being spearheaded by Vigsur Dynamics Inc., which has adopted a structured, parallel approach to technical and business development since its formation in January 2026. Following extensive customer discovery and engagement with the Oregon State University accelerator, Vigsur Dynamics is working to establish a business model that transitions from pilot demonstrations to modular hardware sales, ultimately aiming for a "build-own-operate" service strategy. Current technical milestones—including 100 hours of continuous operation, superior energy efficiency, and successful 6-unit modular scale-up— provide a foundation for this transition. Backed by ongoing IP licensing and a growing network of industrial and venture advisors, the company is actively de-risking the platform to replace conventional mixer-settler systems in the critical minerals market.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH

Characterization of Flashback and Flame-Holding in a Jet-In-Crossflow Mixing Configuration with Methane-Hydrogen Fuel Blends

An approach that combines experimental and numerical analyses has been implemented to characterize the fundamentals of flashback events and flame-holding phenomena during high-hydrogen combustion in a jet-in-crossflow (JICF) configuration. Such flame dynamics are visualized experimentally using nanosecond (ns)-based hydroxyl planar laser-induced fluorescence (OH-PLIF) and chemiluminescence (CL) diagnostics techniques. The JICF burner has an optically accessible pre-mixing tube allowing the optical diagnostics. The testing was conducted for varied pre-mixer velocities (V) and equivalence ratio (ϕ) for 90%-100% (H2, by mole) H2/CH4 reactant mixtures at atmospheric temperature and pressure conditions. Two distinct flashbacks were identified – conventional rich flashback and lean flashback, recorded while increasing ϕ and decreasing ϕ, respectively. The cause of lean flashback was attributed to lower flux ratio which bends the jet sharply, closer toward the injection plane. The flashback was found to occur along the boundary layer, assisted by the inner wall of the pre-mixer tube. The mean OH-PLIF images characterized the flame-holding behavior where the flame was found to be stabilized on the leeward side only or on both windward and leeward sides as a lifted flame near the fuel port.

flame holding

Extrusion compression molded critical rare earth free bonded permanent magnets

Samarium iron nitride (Sm-Fe-N) bonded magnets have emerged as promising candidates for various industrial applications due to their exceptional magnetic properties. Compounds with magnetic material 95 wt fraction (wt.%) (∼74 vol%) and 97 wt.% (∼81 vol%) of SmFeN in a polyamide (PA12) polymer binder are manufactured using a batch mixer followed by compression molding. A maximum energy product ( BH ) max of 186.21 kJ.m -3 (23.4 MGOe) is achieved in the 95 wt.% bonded magnets; 97 wt.% magnets had a ( BH ) max of 165.52 kJ.m -3 (20.8 MGOe). It is found that the degree of alignment (DoA) of 99 % is achieved in the 95 wt.% magnets, whereas the 97 wt.% magnets are limited to a DoA of 90 % respectively. The high DoA can be attributed to low particle-particle interaction during the post-magnetic field alignment process. Finally, this research provides a useful insight of binder-particle interactions at very high magnet weight fractions and their effect on magnetic strength and performance.

36 MATERIALS SCIENCE

Impact of melt viscosity on filler dispersion in elastomeric nanocomposites

Compounding of commercial nanocomposites usually involves the addition of viscosity enhancers such as binder resins in ink jet inks, and paints. Contrary to this, plasticizers such as process oils are added to reduce the melt viscosity and ease processability of reinforced elastomers. Nanofillers such as silica and carbon black are typically added to reinforce rubber and enhance performance of automotive tire treads. Filler dispersion has traditionally been qualitatively (indirectly) assessed by measuring the properties of reinforced elastomers. While dispersion can be quantified by examining filler agglomeration through surface roughness measurements and microscopy, the size-scale dependence for these hierarchical fillers has usually been ignored. Here, we have recently devised a method to quantify nano-scale dispersion of fillers using Ultra small-angle X-ray scattering (USAXS) techniques. This method is advantageous since it directly links the controllable processing/compounding parameters such as the mixing speed, mixer geometry, residence time (or mixing duration), melt density, flow gap distance, and melt viscosity to nano-scale dispersion. While our previous studies have explored the impact of different processing parameters, this study specifically investigates the impact of melt viscosity on nano-scale filler dispersion in elastomer compounds. Commercially available polybutadienes with different Mooney viscosities were used in conjunction with different grades and amounts of process oils to modify the melt viscosity.

Carbon black

Upgrade of DIII-D radial interferometer–polarimeter for large bandwidth, low noise, and toroidal mode number measurements

Near ion-cyclotron frequency (f ci ) fluctuations, such as those originating from Global and Compressional Alfvén Eigenmodes (GAEs/CAEs), are expected to be present in future fusion reactors but are not well understood due to the limited availability of core measurements in present-day tokamaks. The measurement bandwidth of the Radial Interferometer–Polarimeter (RIP) diagnostic has been upgraded from 1 to 5 MHz to detect these fluctuations in DIII-D. RIP adopts the three-wave technique for simultaneous polarimetric and interferometric measurements. Solid-state microwave sources operating at 650 GHz are used as probe beams and provide 5 MHz bandwidth for both polarimetric and interferometric measurements. Bandwidths of related hardware, including mixer amplifier, signal cable, and digital phase demodulator, are increased correspondingly. Measurement noise is minimized by reducing the time delay between reference and probe signals to nanosecond level and employing correlation-based techniques. Using the upgraded diagnostic, CAE/GAE-like bursting fluctuations are observed in neutral-beam heated plasmas with toroidal magnetic field B φ ≈ 1 T. Current upgrades being undertaken would enable the evaluation of toroidal mode number for these modes. Furthermore, this work opens the possibility of better understanding near ion-cyclotron frequency fluctuations in fusion relevant plasmas.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY

High-power test of a C-band linear accelerating structure with an RFSoC-based LLRF system

Normal conducting linear particle accelerators consist of multiple rf stations with accelerating structure cavities. Low-level rf (LLRF) systems are employed to set the phase and amplitude of the field in the accelerating structure and to compensate for the pulse-to-pulse fluctuation of the rf field in the accelerating structures with a feedback loop. The LLRF systems are typically implemented with analog rf mixers, heterodyne-based architectures, and discrete data converters. There are multiple rf signals from each of the rf stations, so the number of rf channels required increases rapidly with multiple rf stations. With a large number of rf channels, the footprint, component cost, and system complexity of the LLRF hardware will increase significantly. To meet the design goals of being compact and affordable for future accelerators, we have designed the next-generation LLRF (NG-LLRF) with a higher integration level based on RFSoC technology. The NG-LLRF system samples rf signals directly and performs rf mixing digitally. Further, the NG-LLRF has been characterized in loopback mode to evaluate the performance of the system and has also been tested with a standing-wave accelerating structure, a prototype for the Cool Copper Collider (C 3 ) with a peak rf power level up to 16.45 MW. The loopback test demonstrated amplitude fluctuation below 0.15% and phase fluctuation below 0.15°, which are considerably better than the requirements of C 3 . The rf signals from the different stages of the accelerating structure at different power levels are measured by the NG-LLRF, which will be critical references for the control algorithm designs. The NG-LLRF also offers flexibility in waveform modulation, so we have used rf pulses with various modulation schemes, which could be useful for controlling some of the rf stations in accelerators. In this paper, the high-power test results at different stages of the test setup will be summarized, analyzed, and discussed.

47 OTHER INSTRUMENTATION