Search NASA⌕ Search

SEARCH · Search NASA

Results for “MONTE CARLO FANS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Computing for Finance

The finance sector is one of the driving forces for the use of distributed or Grid computing for business purposes. The speakers will review the state-of-the-art of high performance computing in the financial sector, and provide insight into how different types of Grid computing – from local clusters to global networks - are being applied to financial applications. They will also describe the use of software and techniques from physics, such as Monte Carlo simulations, in the financial world. There will be four talks of 20min each. The talk abstracts and speaker bios are listed below. This will be followed by a Q&A; panel session with the speakers. From 19:00 onwards there will be a networking cocktail for audience and speakers. This is an EGEE / CERN openlab event organized in collaboration with the regional business network rezonance.ch. A webcast of the event will be made available for subsequent viewing, along with powerpoint material presented by the speakers. Attendance is free and open to all. Registration is mandatory via www.rezonance.ch, including for CERN staff. 1. Overview of High Performance Computing in the Financial Industry. Michael Yoo, Managing Director, Head of the Technical Council, UBS. Presentation will describe the key business challenges driving the need for HPC solutions, describe the means in which those challenges are being addressed within UBS (such as GRID) as well as the limitations of some of these solutions, and assess some of the newer HPC technologies which may also play a role in the Financial Industry in the future. Speaker Bio: Michael originally joined the former Swiss Bank Corporation in 1994 in New York as a developer on a large data warehouse project. In 1996 he left SBC and took a role with Fidelity Investments in Boston. Unable to stay away for long, he returned to SBC in 1997 while working for Perot Systems in Singapore. Finally, in 1998 he formally returned to UBS in Stamford following the merger with SBC and has remained with UBS for the past 9 years. During his tenure at UBS, he has had a number of leadership roles within IT in development, support and architecture. In 2006 Michael relocated to Switzerland to take up his current role as head of the UBS IB Technical Council, responsible for the overall technology strategy and vision of the Investment Bank. One of Michael's key responsibilities is to manage the UBS High Performance Computing Research Lab and he has been involved in a number of initiatives in the HPC space. 2. Grid in the Commercial WorldFred Gedling, Chief Technology Officer EMEA and Senior Vice President Global Services, DataSynapse. Grid computing gets mentions in the press for community programs starting last decade with "Seti@Home". Government, national and supranational initiatives in grid receive some press. One of the IT-industries' best-kept secrets is the use of grid computing by commercial organizations with spectacular results. Grid Computing and its evolution into Application Virtualization is discussed and how this is key to the next generation data center. Speaker Bio: Fred Gedling holds the joint roles of Chief Technology Officer for EMEA and Senior Vice President of Global Services at DataSynapse, a global provider of application virtualisation software. Based in London and working closely with organisations seeking to optimise their IT infrastructures, Fred offers unique insights into the technology of virtualisation as well as the methodology of establishing ROI and rapid deployment to the immediate advantage of the business. Fred has more than fifteen years experience of enterprise middleware and high-performance infrastructures. Prior to DataSynapse he worked in high performance CRM middleware and was the CTO EMEA for New Era of Networks (NEON) during the rapid growth of Enterprise Application Integration. His 25-year career in technology also includes management positions at Goldman Sachs and Stratus Computer. Fred holds a First Class Bsc (Hons) degree in Physics with Astrophysics from the University of Leeds and had the privilege of being a summer student at CERN.3. Opportunities for gLite in finance and related industriesAdam Vile, Head of Grid, HPC and Technical Computing, Excelian Ltd.gLite, the Grid software developed by the EGEE project, has been exceedingly successful as an enabling infrastructure, and has been a massive success in bringing together scientific and technical communities to provide the compute power to address previously incomputable problems. Not so in the finance industry. In its current form gLite would be a business disabler. There are other middleware tools that solve the finance communities compute problems much better. Things are moving on, however. There are moves afoot in the open source community to evolve the technology to address other, more sophisticated needs such as utility and interactive computing. In this talk, I will describe how Excelian is providing Grid consultancy services for the finance community and how, through its relationship to the EGEE project, Excelian is helping to identify and exploit opportunities as the research and business worlds converge. Because of the strong third party presence in the finance industry, such opportunities are few and far between, but they are there, especially as we expand sideways into related verticals such as the smaller hedge funds and energy companies. This talk will give an overview of the barriers to adoption of gLite in the finance industry and highlight some of the opportunities offered in this and related industries as the ideas around Grid mature. Speaker Bio: Dr Adam Vile is a senior consultant and head of the Grid and HPC practice at Excelian, a consultancy that focuses on financial markets professional services. He has spent many years in investment banking, as a developer, project manager and architect in both front and back office. Before joining Excelian he was senior Grid and HPC architect at Barclays Capital. Prior to joining investment banking, Adam spent a number of years lecturing in IT and mathematics at a UK University and maintains links with academia through lectures, research and through validation and steering of postgraduate courses. He is a chartered mathematician and was the conference chair of the Institute of Mathematics and its Applications first conference in computational Finance.4. From Monte Carlo to Wall Street Daniel Egloff, Head of Financial Engineering Computing Unit, Zürich Cantonal Bank High performance computing techniques provide new means to solve computationally hard problems in the financial service industry. First I consider Monte Carlo simulation and illustrate how it can be used to implement a sophisticated credit risk management and economic capital framework. From a HPC perspective, basic Monte Carlo simulation is embarrassingly parallel and can be implemented efficiently on distributed memory clusters. Additional difficulties arise for adaptive variance reduction schemes, if the information content in a sample is very small, and if the amount of simulated date becomes huge such that incremental processing algorithms are indispensable. We discuss the business value of an advanced credit risk quantification which is particularly compelling in these days. While Monte Carlo simulation is a very versatile tool it is not always the preferred solution for the pricing of complex products like multi asset options, structured products, or credit derivatives. As a second application I show how operator methods can be used to develop a pricing framework. The scalability of operator methods relies heavily on optimized dense matrix-matrix multiplications and requires specialized BLAS level-3 implementations provided by specialized FPGA or GPU boards. Speaker Bio: Daniel Egloff studied mathematics, theoretical physics, and computer science at the University of Zurich and the ETH Zurich. He holds a PhD in Mathematics from University of Fribourg, Switzerland. After his PhD he started to work for a large Swiss insurance company in the area of asset and liability management. He continued his professional career in the consulting industry. At KPMG and Arthur Andersen he consulted international clients and implemented quantitative risk management solutions for financial institutions and insurance companies. In 2002 he joined Zurich Cantonal Bank. He was assigned to develop and implement credit portfolio risk and economic capital methodologies. He built up a competence center for high performance and cluster computing. Currently, Daniel Egloff is heading the Financial Computing unit in the ZKB Financial Engineering division. He and his team is engineering and operating high performance cluster applications for computationally intensive problems in financial risk management.

97 MATHEMATICS AND COMPUTING↗

Organ doses for reference adult male and female undergoing computed tomography estimated by Monte Carlo simulations

Purpose: To develop a computed tomography (CT) organ dose estimation method designed to readily provide organ doses in a reference adult male and female for different scan ranges to investigate the degree to which existing commercial programs can reasonably match organ doses defined in these more anatomically realistic adult hybrid phantomsMethods: The x-ray fan beam in the SOMATOM Sensation 16 multidetector CT scanner was simulated within the Monte Carlo radiation transport code MCNPX2.6. The simulated CT scanner model was validated through comparison with experimentally measured lateral free-in-air dose profiles and computed tomography dose index (CTDI) values. The reference adult male and female hybrid phantoms were coupled with the established CT scanner model following arm removal to simulate clinical head and other body region scans. A set of organ dose matrices were calculated for a series of consecutive axial scans ranging from the top of the head to the bottom of the phantoms with a beam thickness of 10 mm and the tube potentials of 80, 100, and 120 kVp. The organ doses for head, chest, and abdomen/pelvis examinations were calculated based on the organ dose matrices and compared to those obtained from two commercial programs, CT-EXPO and CTDOSIMETRY. Organ dose calculations were repeated for an adult stylized phantom by using the same simulation method used for the adult hybrid phantom. Results: Comparisons of both lateral free-in-air dose profiles and CTDI values through experimental measurement with the Monte Carlo simulations showed good agreement to within 9%. Organ doses for head, chest, and abdomen/pelvis scans reported in the commercial programs exceeded those from the Monte Carlo calculations in both the hybrid and stylized phantoms in this study, sometimes by orders of magnitude. Conclusions: The organ dose estimation method and dose matrices established in this study readily provides organ doses for a reference adult male and female for different CT scan ranges and technical parameters. Organ doses from existing commercial programs do not reasonably match organ doses calculated for the hybrid phantoms due to differences in phantom anatomy, as well as differences in organ dose scaling parameters. The organ dose matrices developed in this study will be extended to cover different technical parameters, CT scanner models, and various age groups.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-E-T-467: Implementation of Monte Carlo Dose Calculation for a Multileaf Collimator Equipped Robotic Radiotherapy System

Purpose: To improve the treatment efficiency and capabilities for full-body treatment, a robotic radiosurgery system has equipped with a multileaf collimator (MLC) to extend its accuracy and precision to radiation therapy. To model the MLC and include it in the Monte Carlo patient dose calculation is the goal of this work. Methods: The radiation source and the MLC were carefully modeled to consider the effects of the source size, collimator scattering, leaf transmission and leaf end shape. A source model was built based on the output factors, percentage depth dose curves and lateral dose profiles measured in a water phantom. MLC leaf shape, leaf end design and leaf tilt for minimizing the interleaf leakage and their effects on beam fluence and energy spectrum were all considered in the calculation. Transmission/leakage was added to the fluence based on the transmission factors of the leaf and the leaf end. The transmitted photon energy was tuned to consider the beam hardening effects. The calculated results with the Monte Carlo implementation was compared with measurements in homogeneous water phantom and inhomogeneous phantoms with slab lung or bone material for 4 square fields and 9 irregularly shaped fields. Results: The calculated output factors are compared with the measured ones and the difference is within 1% for different field sizes. The calculated dose distributions in the phantoms show good agreement with measurements using diode detector and films. The dose difference is within 2% inside the field and the distance to agreement is within 2mm in the penumbra region. The gamma passing rate is more than 95% with 2%/2mm criteria for all the test cases. Conclusion: Implementation of Monte Carlo dose calculation for a MLC equipped robotic radiosurgery system is completed successfully. The accuracy of Monte Carlo dose calculation with MLC is clinically acceptable. This work was supported by Accuray Inc.

60 APPLIED LIFE SCIENCES↗

Bowtie filters for dedicated breast CT: Analysis of bowtie filter material selection

Purpose: For a given bowtie filter design, both the selection of material and the physical design control the energy fluence, and consequently the dose distribution, in the object. Using three previously described bowtie filter designs, the goal of this work is to demonstrate the effect that different materials have on the bowtie filter performance measures. Methods: Three bowtie filter designs that compensate for one or more aspects of the beam-modifying effects due to the differences in path length in a projection have been designed. The nature of the designs allows for their realization using a variety of materials. The designs were based on a phantom, 14 cm in diameter, composed of 40% fibroglandular and 60% adipose tissue. Bowtie design #1 is based on single material spectral matching and produces nearly uniform spectral shape for radiation incident upon the detector. Bowtie design #2 uses the idea of basis-material decomposition to produce the same spectral shape and intensity at the detector, using two different materials. With bowtie design #3, it is possible to eliminate the beam hardening effect in the reconstructed image by adjusting the bowtie filter thickness so that the effective attenuation coefficient for every ray is the same. Seven different materials were chosen to represent a range of chemical compositions and densities. After calculation of construction parameters for each bowtie filter design, a bowtie filter was created using each of these materials (assuming reasonable construction parameters were obtained), resulting in a total of 26 bowtie filters modeled analytically and in the PENELOPE Monte Carlo simulation environment. Using the analytical model of each bowtie filter, design profiles were obtained and energy fluence as a function of fan-angle was calculated. Projection images with and without each bowtie filter design were also generated using PENELOPE and reconstructed using FBP. Parameters such as dose distribution, noise uniformity, and scatter were investigated. Results: Analytical calculations with and without each bowtie filter show that some materials for a given design produce bowtie filters that are too large for implementation in breast CT scanners or too small to accurately manufacture. Results also demonstrate the ability to manipulate the energy fluence distribution (dynamic range) by using different materials, or different combinations of materials, for a given bowtie filter design. This feature is especially advantageous when using photon counting detector technology. Monte Carlo simulation results from PENELOPE show that all studied material choices for bowtie design #2 achieve nearly uniform dose distribution, noise uniformity index less than 5%, and nearly uniform scatter-to-primary ratio. These same features can also be obtained using certain materials with bowtie designs #1 and #3. Conclusions: With the three bowtie filter designs used in this work, the selection of material is an important design consideration. An appropriate material choice can improve image quality, dose uniformity, and dynamic range.

60 APPLIED LIFE SCIENCES↗

Collimator design for a multipinhole brain SPECT insert for MRI

Purpose: Brain single photon emission computed tomography (SPECT) imaging is an important clinical tool, with unique tracers for studying neurological diseases. Nowadays, most commercial SPECT systems are combined with x-ray computed tomography (CT) in so-called SPECT/CT systems to obtain an anatomical background for the functional information. However, while CT images have a high spatial resolution, they have a low soft-tissue contrast, which is an important disadvantage for brain imaging. Magnetic resonance imaging (MRI), on the other hand, has a very high soft-tissue contrast and does not involve extra ionizing radiation. Therefore, the authors designed a brain SPECT insert that can operate inside a clinical MRI. Methods: The authors designed and simulated a compact stationary multipinhole SPECT insert based on digital silicon photomultiplier detector modules, which have shown to be MR-compatible and have an excellent intrinsic resolution (0.5 mm) when combined with a monolithic 2 mm thick LYSO crystal. First, the authors optimized the different parameters of the SPECT system to maximize sensitivity for a given target resolution of 7.2 mm in the center of the field-of-view, given the spatial constraints of the MR system. Second, the authors performed noiseless simulations of two multipinhole configurations to evaluate sampling and reconstructed resolution. Finally, the authors performed Monte Carlo simulations and compared the SPECT insert with a clinical system with ultrahigh-resolution (UHR) fan beam collimators, based on contrast-to-noise ratio and a visual comparison of a Hoffman phantom with a 9 mm cold lesion. Results: The optimization resulted in a stationary multipinhole system with a collimator radius of 150.2 mm and a detector radius of 172.67 mm, which corresponds to four rings of 34 diSPM detector modules. This allows the authors to include eight rings of 24 pinholes, which results in a system volume sensitivity of 395 cps/MBq. Noiseless simulations show sufficient axial sampling (in a Defrise phantom) and a reconstructed resolution of 5.0 mm (in a cold-rod phantom). The authors compared the 24-pinhole setup with a 34-pinhole system (with the same detector radius but a collimator radius of 156.63 mm) and found that 34 pinholes result in better uniformity but a worse reconstruction of the cold-rod phantom. The authors also compared the 24-pinhole system with a clinical triple-head UHR fan beam system based on contrast-to-noise ratio and found that the 24-pinhole setup performs better for the 6 mm hot and the 16 mm cold lesions and worse for the 8 and 10 mm hot lesions. Finally, the authors reconstructed noisy projection data of a Hoffman phantom with a 9 mm cold lesion and found that the lesion was slightly better visible on the multipinhole image compared to the fan beam image. Conclusions: The authors have optimized a stationary multipinhole SPECT insert for MRI and showed the feasibility of doing brain SPECT imaging inside a MRI with an image quality similar to the best clinical SPECT systems available.

60 APPLIED LIFE SCIENCES↗

WE-EF-207-06: Dedicated Cone-Beam Breast CT with Laterally-Shifted Detector: Monte Carlo Evaluation of X-Ray Scatter Distribution and Scatter-To-Primary Ratio

Purpose: To determine the spatial distribution of x-ray scatter and scatter-to-primary ratio (SPR) in projections during cone-beam breast CT (CBBCT) with laterally-shifted detector that results in coronal (fan-angle) truncation. Methods: We hypothesized that CBBCT with coronal truncation would lower SPR due to reduction in irradiated breast volume, and that the location of maximum x-ray scatter fluence (scatter-peak) in the detector plane can be determined from the ratio of irradiated-to-total breast volume, breast dimensions and system geometry. Monte Carlo simulations (GEANT4) reflecting a prototype CBBCT system were used to record the position-dependent primary and scatter x-ray photon fluence incident on the detector without coronal truncation (full fan-angle, 2f=24-degrees) and with coronal truncation (fan-angle, f+ f=12+2.7-degrees). Semi-ellipsoidal breasts (10/14/18-cm diameter, chest-wall to nipple length: 0.75xdiameter, 2%/14%/100% fibroglandular content) aligned with the axis-of-rotation (AOR) were modeled. Mono-energy photons were simulated and weighted for 2 spectra (49kVp, 1.4-mm Al HVL; 60kVp, 3.76-mm Al HVL). In addition to SPR, the scatter maps were analyzed to identify the location of the scatter-peak. Results: For CBBCT without fan-angle truncation, the scatter-peaks were aligned with the projection of the AOR onto the detector for all breasts. With truncated fan-beam, the scatter-peaks were laterally-shifted from the projection of the AOR along the fan-angle direction by 14/38/70-pixels for 10/14/18-cm diameter breasts. The corresponding theoretical shifts were 14.8/39.7/68-pixels (p=0.47, 2-tailed paired-ratio t-test). Along the cone-angle, the shift in scatter-peaks between truncated and full-fan angle CBBCT were 2/2/4 -pixels for 10/14/18-cm diameter breasts. CBBCT with fan-angle truncation reduced SPR by 14/22/28% for 10/14/18-cm diameter breasts. 60kVp reduced SPR by 21–25% compared to 49kVp. Peak SPR for CBBCT with fan-angle truncation (60kVp) were 0.09/0.25/0.73 for 10/14/18-cm diameter breasts. Conclusion: CBBCT with laterally-shifted detector geometry and with appropriate kVp/beam quality reduces SPR. If residual scatter needs correction, the location corresponding to scatter-peak can be analytically computed. This work was supported in part by NIH R01 CA128906. The contents are solely the responsibility of the authors and do not reflect the official views of the NIH or NCI.

60 APPLIED LIFE SCIENCES↗

Random fan-out state induced by site-random interlayer couplings

We study the low-temperature properties of a classical Heisenberg model with site-random interlayer couplings on the cubic lattice. This model is introduced as a simplified effective model of Sr(Fe{sub 1-x}Mn{sub x})O{sub 2}, which was recently synthesized. In this material, when x=0.3, ({pi}{pi}{pi}) and ({pi}{pi}0) mixed ordering is observed by neutron diffraction measurements. Using Monte Carlo simulations, we find an exotic bulk spin structure that explains the experimentally obtained results. We name this spin structure the ''random fan-out state.'' The mean-field calculations provide an intuitive understanding of this phase being induced by the site-random interlayer couplings. Since Rietveld analysis assuming the random fan-out state agrees well with the neutron diffraction pattern of Sr(Fe{sub 0.7}Mn{sub 0.3})O{sub 2}, we conclude that the random fan-out state is reasonable for the spin-ordering pattern of Sr(Fe{sub 0.7}Mn{sub 0.3})O{sub 2} at the low-temperature phase.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Personalized Assessment of kV Cone Beam Computed Tomography Doses in Image-guided Radiotherapy of Pediatric Cancer Patients

Purpose: To develop a quantitative method for the estimation of kV cone beam computed tomography (kVCBCT) doses in pediatric patients undergoing image-guided radiotherapy. Methods and Materials: Forty-two children were retrospectively analyzed in subgroups of different scanned regions: one group in the head-and-neck and the other group in the pelvis. Critical structures in planning CT images were delineated on an Eclipse treatment planning system before being converted into CT phantoms for Monte Carlo simulations. A benchmarked EGS4 Monte Carlo code was used to calculate three-dimensional dose distributions of kVCBCT scans with full-fan high-quality head or half-fan pelvis protocols predefined by the manufacturer. Based on planning CT images and structures exported in DICOM RT format, occipital-frontal circumferences (OFC) were calculated for head-and-neck patients using DICOMan software. Similarly, hip circumferences (HIP) were acquired for the pelvic group. Correlations between mean organ doses and age, weight, OFC, and HIP values were analyzed with SigmaPlot software suite, where regression performances were analyzed with relative dose differences (RDD) and coefficients of determination (R{sup 2}). Results: kVCBCT-contributed mean doses to all critical structures decreased monotonically with studied parameters, with a steeper decrease in the pelvis than in the head. Empirical functions have been developed for a dose estimation of the major organs at risk in the head and pelvis, respectively. If evaluated with physical parameters other than age, a mean RDD of up to 7.9% was observed for all the structures in our population of 42 patients. Conclusions: kVCBCT doses are highly correlated with patient size. According to this study, weight can be used as a primary index for dose assessment in both head and pelvis scans, while OFC and HIP may serve as secondary indices for dose estimation in corresponding regions. With the proposed empirical functions, it is possible to perform an individualized quantitative dose assessment of kVCBCT scans.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Looking at A 0535+26 at Low Luminosities with NuSTAR

We report on two NuSTAR observations of the high-mass X-ray binary A 0535+26 taken toward the end of its normal 2015 outburst at very low 3-50 keV luminosities of approximately 1.4 times x 10 (sup 36) ergs per second and approximately 5 times x 10 (sup 35) ergs per second, which are complemented by nine Swift observations. The data clearly confirm indications seen in earlier data that the source's spectral shape softens as it becomes fainter. The smooth exponential rollover at high energies seen in the first observation evolves to a much more abrupt steepening of the spectrum at 20-30 keV. The continuum evolution can be nicely described with emission from a magnetized accretion column, modeled using the compmag model modified by an additional Gaussian emission component for the fainter observation. Between the two observations, the optical depth changes from 0.75 plus or minus 0.04 to 0.56 plus 0.01 (sup) minus 0.04 (sub), the electron temperature remains constant, and there is an indication that the column decreases in radius. Since the energy-resolved pulse profiles remain virtually unchanged in shape between the two observations, the emission properties of the accretion column reflect the same accretion regime. This conclusion is also confirmed by our result that the energy of the cyclotron resonant scattering feature (CRSF) at approximately 45 keV is independent of the luminosity, implying that the magnetic field in the region in which the observed radiation is produced is the same in both observations. Finally, we also constrain the evolution of the continuum parameters with the rotational phase of the neutron star. The width of the CRSF could only be constrained for the brighter observation. Based on Monte Carlo simulations of CRSF formation in single accretion columns, its pulse phase dependence supports a simplified fan beam emission pattern. The evolution of the CRSF width is very similar to that of the CRSF depth, which is, however, in disagreement with expectations.

Ballhausen, Ralf↗

SU-E-J-125: Classification of CBCT Noises in Terms of Their Contribution to Proton Range Uncertainty

Purpose: This study assesses the potential use of CBCT images in adaptive protontherapy by estimating the contribution of the main sources of noise and calibration errors to the proton range uncertainty. Methods: Measurements intended to highlight each particular source have been achieved by adapting either the testbench configuration, e.g. use of filtration, fan-beam collimation, beam stop arrays, phantoms and detector reset light, or the sequence of correction algorithms including water precorrection. Additional Monte-Carlo simulations have been performed to complement these measurements, especially for the beam hardening and the scatter cases. Simulations of proton beams penetration through the resulting images have then been carried out to quantify the range change due to these effects. The particular case of a brain irradiation is considered mainly because of the multiple effects that the skull bones have on the internal soft tissues. Results: On top of the range error sources is the undercorrection of scatter. Its influence has been analyzed from a comparison of fan-beam and full axial FOV acquisitions. In this case, large range errors of about 12 mm can be reached if the assumption is made that the scatter has only a constant contribution over the projection images. Even the detector lag, which a priori induces a much smaller effect, has been shown to contribute for up to 2 mm to the overall error if its correction only aims at reducing the skin artefact. This last result can partially be understood by the larger interface between tissues and bones inside the skull. Conclusion: This study has set the basis of a more systematical analysis of the effect CBCT noise on range uncertainties based on a combination of measurements, simulations and theoretical results. With our method, even more subtle effects such as the cone-beam artifact or the detector lag can be assessed. SBR and JOR are financed by iMagX, a public-private partnership between the region Wallone of Belgium and IBA under convention #1217662.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Panoramic cone beam computed tomography

Purpose: Cone-beam computed tomography (CBCT) is the main imaging tool for image-guided radiotherapy but its functionality is limited by a small imaging volume and restricted image position (imaged at the central instead of the treatment position for peripheral lesions to avoid collisions). In this paper, the authors present the concept of ''panoramic CBCT,'' which can image patients at the treatment position with an imaging volume as large as practically needed. Methods: In this novel panoramic CBCT technique, the target is scanned sequentially from multiple view angles. For each view angle, a half scan (180 deg. + {theta}{sub cone} where {theta}{sub cone} is the cone angle) is performed with the imaging panel positioned in any location along the beam path. The panoramic projection images of all views for the same gantry angle are then stitched together with the direct image stitching method (i.e., according to the reported imaging position) and full-fan, half-scan CBCT reconstruction is performed using the stitched projection images. To validate this imaging technique, the authors simulated cone-beam projection images of the Mathematical Cardiac Torso (MCAT) thorax phantom for three panoramic views. Gaps, repeated/missing columns, and different exposure levels were introduced between adjacent views to simulate imperfect image stitching due to uncertainties in imaging position or output fluctuation. A modified simultaneous algebraic reconstruction technique (modified SART) was developed to reconstruct CBCT images directly from the stitched projection images. As a gold standard, full-fan, full-scan (360 deg. gantry rotation) CBCT reconstructions were also performed using projection images of one imaging panel large enough to encompass the target. Contrast-to-noise ratio (CNR) and geometric distortion were evaluated to quantify the quality of reconstructed images. Monte Carlo simulations were performed to evaluate the effect of scattering on the image quality and imaging dose for both standard and panoramic CBCT. Results: Truncated images with artifacts were observed for the CBCT reconstruction using projection images of the central view only. When the image stitching was perfect, complete reconstruction was obtained for the panoramic CBCT using the modified SART with the image quality similar to the gold standard (full-scan, full-fan CBCT using one large imaging panel). Imperfect image stitching, on the other hand, lead to (streak, line, or ring) reconstruction artifacts, reduced CNR, and/or distorted geometry. Results from Monte Carlo simulations showed that, for identical imaging quality, the imaging dose was lower for the panoramic CBCT than that acquired with one large imaging panel. For the same imaging dose, the CNR of the three-view panoramic CBCT was 50% higher than that of the regular CBCT using one big panel. Conclusions: The authors have developed a panoramic CBCT technique and demonstrated with simulation data that it can image tumors of any location for patients of any size at the treatment position with comparable or less imaging dose and time. However, the image quality of this CBCT technique is sensitive to the reconstruction artifacts caused by imperfect image stitching. Better algorithms are therefore needed to improve the accuracy of image stitching for panoramic CBCT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Metallic artifact mitigation and organ-constrained tissue assignment for Monte Carlo calculations of permanent implant lung brachytherapy

Purpose: To investigate methods of generating accurate patient-specific computational phantoms for the Monte Carlo calculation of lung brachytherapy patient dose distributions. Methods: Four metallic artifact mitigation methods are applied to six lung brachytherapy patient computed tomography (CT) images: simple threshold replacement (STR) identifies high CT values in the vicinity of the seeds and replaces them with estimated true values; fan beam virtual sinogram replaces artifact-affected values in a virtual sinogram and performs a filtered back-projection to generate a corrected image; 3D median filter replaces voxel values that differ from the median value in a region of interest surrounding the voxel and then applies a second filter to reduce noise; and a combination of fan beam virtual sinogram and STR. Computational phantoms are generated from artifact-corrected and uncorrected images using several tissue assignment schemes: both lung-contour constrained and unconstrained global schemes are considered. Voxel mass densities are assigned based on voxel CT number or using the nominal tissue mass densities. Dose distributions are calculated using the EGSnrc user-code BrachyDose for{sup 125}I, {sup 103}Pd, and {sup 131}Cs seeds and are compared directly as well as through dose volume histograms and dose metrics for target volumes surrounding surgical sutures. Results: Metallic artifact mitigation techniques vary in ability to reduce artifacts while preserving tissue detail. Notably, images corrected with the fan beam virtual sinogram have reduced artifacts but residual artifacts near sources remain requiring additional use of STR; the 3D median filter removes artifacts but simultaneously removes detail in lung and bone. Doses vary considerably between computational phantoms with the largest differences arising from artifact-affected voxels assigned to bone in the vicinity of the seeds. Consequently, when metallic artifact reduction and constrained tissue assignment within lung contours are employed in generated phantoms, this erroneous assignment is reduced, generally resulting in higher doses. Lung-constrained tissue assignment also results in increased doses in regions of interest due to a reduction in the erroneous assignment of adipose to voxels within lung contours. Differences in dose metrics calculated for different computational phantoms are sensitive to radionuclide photon spectra with the largest differences for{sup 103}Pd seeds and smallest but still considerable differences for {sup 131}Cs seeds. Conclusions: Despite producing differences in CT images, dose metrics calculated using the STR, fan beam + STR, and 3D median filter techniques produce similar dose metrics. Results suggest that the accuracy of dose distributions for permanent implant lung brachytherapy is improved by applying lung-constrained tissue assignment schemes to metallic artifact corrected images.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Heat transfer and forces on concave surfaces in free molecule flow.

A Monte Carlo modeling technique is described for mathematically simulating free molecular flows over a concave spherical surface and a concave cylindrical surface of finite length. The half-angle of the surfaces may vary from 0 to 90 degrees, and the incident flow may have an arbitrary speed ratio and an arbitrary angle of attack. Partial diffuse reflection and imperfect energy accommodation for molecules colliding with the surfaces are also considered. Results of heat transfer, drag and lift coefficients are presented for a variety of flow conditions. The present Monte Carlo results are shown to be in very good agreement with certain available theoretical solutions.

Fan, C.↗

The suppression effect of external magnetic field on the high-power microwave window multipactor phenomenon

To suppress the surface multipactor phenomenon and improve the transmitting power of the high-power microwave window, the application of external magnetic fields is theoretically analyzed and simulated. A Monte Carlo algorithm is used to track the secondary electron trajectories and study the multipactor scenario on the surface of a cylinder window. It is confirmed that over-resonant magnetic fields (an external magnetic field whose magnitude is slightly greater than that of a resonant magnetic field) will generate a compensating trajectory and collision, which can suppress the secondary electron avalanche. The optimal value of this external magnetic field that will avoid the multipactor phenomenon on cylinder windows is discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗