Evaluation of MOPITT Version 7 joint TIR–NIR X CO retrievals with TCCON

Observations of carbon monoxide (CO) from the Measurements Of Pollution In The Troposphere (MOPITT) instrument aboard the Terra spacecraft were expected to have an accuracy of 10 % prior to the launch in 1999. Here we evaluate MOPITT Version 7 joint (V7J) thermal-infrared and near-infrared (TIR–NIR) retrieval accuracy and precision and suggest ways to further improve the accuracy of the observations. We take five steps involving filtering or bias corrections to reduce scatter and bias in the data relative to other MOPITT soundings and ground-based measurements. (1) We apply a preliminary filtering scheme in which measurements over snow and ice are removed. (2) We find a systematic pairwise bias among the four MOPITT along-track detectors (pixels) on the order of 3–4 ppb with a small temporal trend, which we remove on a global scale using a temporally trended bias correction. (3) Using a small-region approximation (SRA), a new filtering scheme is developed and applied based on additional quality indicators such as the signal-to-noise ratio (SNR). After applying these new filters, the root-mean-squared error computed using the local median from the SRA over 16 years of global observations decreases from 3.84 to 2.55 ppb. (4) We also use the SRA to find variability in MOPITT retrieval anomalies that relates to retrieval parameters. We apply a bias correction to one parameter from this analysis. (5) After applying the previous bias corrections and filtering, we compare the MOPITT results with the GGG2014 ground-based Total Carbon Column Observing Network (TCCON) observations to obtain an overall global bias correction. These comparisons show that MOPITT V7J is biased high by about 6 %–8 %, which is similar to past studies using independent validation datasets on V6J. When using TCCON spectrometric column retrievals without the standard airmass correction or scaling to aircraft (WMO scale), the ground- and satellite-based observations overall agree to better than 0.5 %. GEOS-Chem data assimilations are used to estimate the influence of filtering and scaling to TCCON on global CO and tend to pull concentrations away from the prior fluxes and closer to the truth. We conclude with suggestions for further improving the MOPITT data products.

Hedelius, Jacob K. (ORCID:0000000320257519)↗

Toward a chemical reanalysis in a coupled chemistry-climate model: An evaluation of MOPITT CO assimilation and its impact on tropospheric composition

Here, we examine in detail a 1 year global reanalysis of carbon monoxide (CO) that is based on joint assimilation of conventional meteorological observations and Measurement of Pollution in The Troposphere (MOPITT) multispectral CO retrievals in the Community Earth System Model (CESM). Our focus is to assess the impact to the chemical system when CO distribution is constrained in a coupled full chemistry-climate model like CESM. To do this, we first evaluate the joint reanalysis (MOPITT Reanalysis) against four sets of independent observations and compare its performance against a reanalysis with no MOPITT assimilation (Control Run). We then investigate the CO burden and chemical response with the aid of tagged sectoral CO tracers. We estimate the total tropospheric CO burden in 2002 (from ensemble mean and spread) to be 371 ± 12% Tg for MOPITT Reanalysis and 291 ± 9% Tg for Control Run. Our multispecies analysis of this difference suggests that (a) direct emissions of CO and hydrocarbons are too low in the inventory used in this study and (b) chemical oxidation, transport, and deposition processes are not accurately and consistently represented in the model. Increases in CO led to net reduction of OH and subsequent longer lifetime of CH 4 (Control Run: 8.7 years versus MOPITT Reanalysis: 9.3 years). Yet at the same time, this increase led to 5-10% enhancement of Northern Hemisphere O 3 and overall photochemical activity via HO x recycling. Such nonlinear effects further complicate the attribution to uncertainties in direct emissions alone. This has implications to chemistry-climate modeling and inversion studies of longer-lived species.

54 ENVIRONMENTAL SCIENCES↗

Validation of the Measurement of Pollution in the Troposphere (MOPITT) Experiment by Ground-Based Infrared Solar Spectroscopic Measurements of Carbon Monoxide (CO) and Methane (CH4)

The goal of the MOPITT experiment is to enhance our knowledge of the lower atmosphere system and particularly how it interacts with the surface/ocean/biomass systems. The particular focus is the distribution, transport, sources and sinks of carbon monoxide and methane in the troposphere. The MOPITT instrument was launched on EOS TERRA satellite December 18, 1999. After the launch and until March 22, 2000 the MOPITT instrument was in engineering and calibration mode. Beginning March 23, 2000 through May 6, 2001 the instrument was in a science measurement mode with some calibration breaks. On May 7, 2001 a criocooler on a side B died and channels 1 - 4 became inoperational. The MOPITT resumed its scientific measurements on August 25, 2001 with channels 5 - 8. With some calibration breaks the instrument currently provides the data. The project has three elements to it: hardware, data analysis and modeling. The MOPITT instrument, on the NASA EOS Terra satellite, measures the upwelling infrared radiance. Using the technique of correlation spectroscopy, information regarding the distribution of atmospheric CO and CH4 can be extracted. By using appropriate data analysis techniques, concentration profiles of CO are currently obtained on a global basis at a reasonably high horizontal (approximately 22km) and vertical resolution (approximately 3km). Column amounts of methane will be derived over the sunlit side of the orbit. These profiles are assimilated into models to study the chemistry and dynamics of CO, CH4 and other constituents of the lower atmosphere.

Pougatchev, Nikita↗

Assessing the impacts of assimilating IASI and MOPITT CO retrievals using CESM-CAM-chem and DART

We report on the results and evaluation with independent measurements from assimilating both MOPITT (Measurements Of Pollution In The Troposphere) and IASI (Infrared Atmospheric Sounding Interferometer) retrieved profiles into the Community Earth System Model (CESM). We used the Data Assimilation Research Testbed ensemble Kalman filter technique, with the full atmospheric chemistry CESM component Community Atmospheric Model with Chemistry. We first discuss the methodology and evaluation of the current data assimilation system with coupled meteorology and chemistry data assimilation. The various capabilities of MOPITT and IASI retrievals are highlighted, with specific attention to instrument vertical sensitivity and coverage and how these impact the analyses. MOPITT and IASI CO retrievals mostly constrain the CO fields close to the main anthropogenic, biogenic, and biomass burning CO sources. In the case of IASI CO assimilation, we also observe constraints on CO far from the sources. During the simulation time period (June and July 2008), CO assimilation of both instruments strongly improves the atmospheric CO state as compared to independent observations, with the higher spatial coverage of IASI providing better results on the global scale. Yet, the enhanced sensitivity of multispectral MOPITT observations to near surface CO over the main source regions provides synergistic effects at regional scales.

54 ENVIRONMENTAL SCIENCES↗

Measurements of Pollution In The Troposphere (MOPITT) Validation through 2006

Comparisons of aircraft measurements of carbon monoxide (CO) to the retrievals of CO using observations from the Measurements of Pollution in The Troposphere (MOPITT) instrument onboard the Terra satellite are presented. Observations made as part of the NASA INTEX-B and NSF MIRAGE field campaigns during March May 2006 are used to validate the MOPITT CO retrievals, along with routine samples from 2001 through 2006 from NOAA and the MOZAIC measurements from commercial aircraft. A significant positive bias, around 20% for total column CO, in MOPITT CO was found in the comparison to in situ measurements during 2006. Comparisons to the long-term records of measurements from NOAA and MOZAIC revealed an increasing bias in the V3 MOPITT CO retrievals over time. The impact of an instrumental drift is illustrated through retrieval simulations.

Emmons, L. K.↗

Southern Hemisphere Carbon Monoxide Inferannual Variability Observed by Terra/Measurement of Pollution in the Troposphere (MOPITT)

Biomass burning is an annual occurrence in the tropical southern hemisphere (SH) and represents a major source of regional pollution. Vegetation fires emit carbon monoxide (CO), which due to its medium lifetime is an excellent tracer of tropospheric transport. CO is also one of the few tropospheric trace gases currently observed from satellite and this provides long-term global measurements. In this paper, we use the 5 year CO data record from the Measurement Of Pollution In The Troposphere (MOPITT) instrument to examine the inter-annual variability of the SH CO loading and show how this relates to climate conditions which determine the intensity of fire sources. The MOPITT observations show an annual austral springtime peak in the SH zonal CO loading each year with dry-season biomass burning emissions in S. America, southern Africa, the Maritime Continent, and northwestern Australia. Although fires in southern Africa and S. America typically produce the greatest amount of CO, the most significant inter-annual variation is due to varying fire activity and emissions from the Maritime Continent and northern Australia. We find that this variation in turn correlates well with the El Nino Southern Oscillation precipitation index. Between 2000 and 2005, emissions were greatest in late 2002 and an inverse modeling of the MOPITT data using the MOZART chemical transport model estimates the southeast Asia regional fire source for the year August 2002 to September 2003 to be 52 Tg CO. Comparison of the MOPITT retrievals and NOAA surface network measurements indicate that the latter do not fully capture the inter-annual variability or the seasonal range of the CO zonal average concentration due to biases associated with atmospheric and geographic sampling.

Edwards, D. P.↗

Measurements of Pollution in the Troposphere (MOPITT) Validation Exercises During Summer 2004 Field Campaigns over North America

Measurements of carbon monoxide (CO) made as part of three aircraft experiments during the summer of 2004 over North America have been used for the continued validation of the CO retrievals from the Measurements of Pollution in the Troposphere (MOPITT) instrument on board the Terra satellite. Vertical profiles measured during the NASA INTEX-A campaign, designed to be coincident with MOPITT overpasses, as well as measurements made during the COBRA-2004 and MOZAIC experiments, provided valuable validation comparisons. On average, the MOPITT CO retrievals are biased slightly high for these North America locations. While the mean bias differs between the different aircraft experiments (e.g., 7.0 ppbv for MOZAIC to 18.4 ppbv for COBRA at 700 hPa), the standard deviations are quite large, so the results for the three data sets can be considered consistent. On average, it is estimated that MOPITT is 7- 14% high at 700 hPa and 03% high at 350 hPa. These results are consistent with the validation results for the Carr, Colorado, Harvard Forest, Massachusetts, and Poker Flats, Alaska, aircraft profiles for "phase 2" presented by Emmons et al. (2004) and are generally within the design criteria of 10% accuracy.

Emmons, L. K.↗

Direct Top-down Estimates of Biomass Burning CO Emissions Using TES and MOPITT Versus Bottom-up GFED Inventory

In this study, we utilize near-simultaneous observations from two sets of multiple satellite sensors to segregate Tropospheric Emission Spectrometer (TES) and Measurements of Pollution in the Troposphere (MOPITT) CO observations over active fire sources from those made over clear background. Hence, we obtain direct estimates of biomass burning CO emissions without invoking inverse modeling as in traditional top-down methods. We find considerable differences between Global Fire Emissions Database (GFED) versions 2.1 and 3.1 and satellite-based emission estimates in many regions. Both inventories appear to greatly underestimate South and Southeast Asia emissions, for example. On global scales, however, CO emissions in both inventories and in the MOPITT-based analysis agree reasonably well, with the largest bias (30%) found in the Northern Hemisphere spring. In the Southern Hemisphere, there is a one-month shift between the GFED and MOPITT-based fire emissions peak. Afternoon tropical fire emissions retrieved from TES are about two times higher than the morning MOPITT retrievals. This appears to be both a real difference due to the diurnal fire activity variations, and a bias due to the scarcity of TES data.

bias↗

MOPITT Mechanisms 16 Years In-Orbit Operation on TERRA

The 16th anniversary of the launch of NASA's Terra Spacecraft was marked on December 18, 2015, with the Measurements of Pollution in the Troposphere (MOPITT) instrument being a successful contributor to the NASA EOS flagship. MOPITT has been enabled by a large suite of mechanisms, allowing the instrument to perform long-duration monitoring of atmospheric carbon monoxide, providing global measurements of this important greenhouse gas for 16 years. Mechanisms have been successfully employed for scanning, cooling of detectors, and to optically modulate the gas path length within the instrument by means of pressure and gas cell length variation. The instrument utilizes these devices to perform correlation spectroscopy, enabling measurements with vertical resolution from the nadir view, and has thereby furthered understanding of source and global transport effects of carbon monoxide. Given the design requirement for a 5.25-year lifetime, the stability and performance of the majority of mechanisms have far surpassed design goals. With 16 continuously operating mechanisms in service on MOPITT, including 12 rotating mechanisms and 4 with linear drive elements, the instrument was an ambitious undertaking. The long life requirements combined with demands for cleanliness and optical stability made for difficult design choices including that of the selection of new lubrication processes. Observations and lessons learned with regards to many aspects of the mechanisms and associated monitoring devices are discussed here. Mechanism behaviors are described, including anomalies, long-term drive current/power, fill pressure, vibration and cold-tip temperature trends. The effectiveness of particular lubrication formulations and the screening method implemented is discussed in relation to continuous rotating mechanisms and stepper motors, which have exceeded 15 billon rotations and 2.5 billion steps respectively. Aspects of gas cell hermeticity, optical cleanliness, heater problems and SEU effects on accelerometers are also discussed.

Gibson, Andrew S.↗

A 15-year record of CO emissions constrained by MOPITT CO observations

Long-term measurements from satellites and surface stations have demonstrated a decreasing trend of tropospheric carbon monoxide (CO) in the Northern Hemisphere over the past decade. Likely explanations for this decrease include changes in anthropogenic, fires, and/or biogenic emissions or changes in the primary chemical sink hydroxyl radical (OH). Using remotely sensed CO measurements from the Measurement of Pollution in the Troposphere (MOPITT) satellite instrument, in situ methyl chloroform (MCF) measurements from the World Data Centre for Greenhouse Gases (WDCGG) and the adjoint of the GEOS-Chem model, we estimate the change in global CO emissions from 2001 to 2015. We show that the loss rate of MCF varied by 0.2 % in the past 15 years, indicating that changes in global OH distributions do not explain the recent decrease in CO. Our two-step inversion approach for estimating CO emissions is intended to mitigate the effect of bias errors in the MOPITT data as well as model errors in transport and chemistry, which are the primary factors contributing to the uncertainties when quantifying CO emissions using these remotely sensed data. Our results confirm that the decreasing trend of tropospheric CO in the Northern Hemisphere is due to decreasing CO emissions from anthropogenic and biomass burning sources. In particular, we find decreasing CO emissions from the United States and China in the past 15 years, and unchanged anthropogenic CO emissions from Europe since 2008. We find decreasing trends of biomass burning CO emissions from boreal North America, boreal Asia and South America, but little change over Africa. In contrast to prior results, we find that a positive trend in CO emissions is likely for India and southeast Asia.

54 ENVIRONMENTAL SCIENCES↗

MOPITT - A gas correlation spectrometer for tropospheric Earth observations

MOPITT (Measurement of Pollution in the Troposphere) is an instrument that will fly on the EOS AM-1 Polar Orbiting Platform, to be launched in mid-1998. The instrument accurately measures the concentration of carbon monoxide (CO) and methane (CH4) gas in the troposphere, using novel and conventional gas correlation spectroscopy techniques. These techniques are used to measure both the column amount and the vertical profile of the two gases in the troposphere. The instrument is nadir viewing and has cross-track scanning ability. It measures upwelling IR radiation through the atmosphere in the 4.6-micron and 2.3-micron bands for CO detection, and 2.2-micron for CH4. The instrument performance is enhanced using Stirling cycle mechanical coolers to maintain the IR detectors at less than 100 K. MOPITT has a total of eight detector channels to measure the total column of atmospheric CH4 gas to a precision of 1 percent, and to measure CO profiles to a precision of 10 percent. The instrument is self-calibrating to ensure data validity using internal targets and an external cold space view.

Drummond, James R.↗

Interpreting Space-Based Trends in Carbon Monoxide with Multiple Models

We use a series of chemical transport model and chemistry climate model simulations to investigate the observed negative trends in MOPITT CO over several regions of the world, and to examine the consistency of timedependent emission inventories with observations. We find that simulations driven by the MACCity inventory, used for the Chemistry Climate Modeling Initiative (CCMI), reproduce the negative trends in the CO column observed by MOPITT for 2000-2010 over the eastern United States and Europe. However, the simulations have positive trends over eastern China, in contrast to the negative trends observed by MOPITT. The model bias in CO, after applying MOPITT averaging kernels, contributes to the model-observation discrepancy in the trend over eastern China. This demonstrates that biases in a model's average concentrations can influence the interpretation of the temporal trend compared to satellite observations. The total ozone column plays a role in determining the simulated tropospheric CO trends. A large positive anomaly in the simulated total ozone column in 2010 leads to a negative anomaly in OH and hence a positive anomaly in CO, contributing to the positive trend in simulated CO. These results demonstrate that accurately simulating variability in the ozone column is important for simulating and interpreting trends in CO.

carbon monoxide↗

Interpreting space-based trends in carbon monoxide with multiple models

Here, we use a series of chemical transport model and chemistry climate model simulations to investigate the observed negative trends in MOPITT CO over several regions of the world, and to examine the consistency of time-dependent emission inventories with observations. We also found that simulations driven by the MACCity inventory, used for the Chemistry Climate Modeling Initiative (CCMI), reproduce the negative trends in the CO column observed by MOPITT for 2000–2010 over the eastern United States and Europe. However, the simulations have positive trends over eastern China, in contrast to the negative trends observed by MOPITT. The model bias in CO, after applying MOPITT averaging kernels, contributes to the model–observation discrepancy in the trend over eastern China. This demonstrates that biases in a model's average concentrations can influence the interpretation of the temporal trend compared to satellite observations. The total ozone column plays a role in determining the simulated tropospheric CO trends. A large positive anomaly in the simulated total ozone column in 2010 leads to a negative anomaly in OH and hence a positive anomaly in CO, contributing to the positive trend in simulated CO. Our results demonstrate that accurately simulating variability in the ozone column is important for simulating and interpreting trends in CO.

54 ENVIRONMENTAL SCIENCES↗

Asian Outflow and Trans-Pacific Transport of Carbon Monoxide and Ozone Pollution: An Integrated Satellite, Aircraft, and Model Perspective

Satellite observations of carbon monoxide (CO) from the Measurements of Pollution in the Troposphere (MOPITT) instrument are combined with measurements from the Transport and Chemical Evolution Over the Pacific (TRACE-P) aircraft mission over the northwest Pacific and with a global three-dimensional chemical transport model (GEOS-CHEM) to quantify Asian pollution outflow and its trans-Pacific transport during spring 2001. Global CO column distributions in MOPITT and GEOS-CHEM are highly correlated (R(exp 2) = 0.87), with no significant model bias. The largest regional bias is over Southeast Asia, where the model is 18% too high. A 60% decrease of regional biomass burning emissions in the model (to 39 Tg/yr) would correct the discrepancy; this result is consistent with TRACE-P observations. MOPITT and TRACE-P also give consistent constraints on the Chinese source of CO from fuel combustion (181 Tg CO/yr). Four major events of trans-Pacific transport of Asian pollution in spring 2001 were seen by MOPITT, in situ platforms, and GEOS-CHEM. One of them was sampled by TRACE-P (26-27 February) as a succession of pollution layers over the northeast Pacific. These layers all originated from one single event of Asian outflow that split into northern and southern plumes over the central Pacific. The northern plume (sampled at 6-8 km off California) had no ozone enhancement. The southern subsiding plume (sampled at 2-4 km west of Hawaii) contained a 8 - 17 ppbv ozone enhancement, driven by decomposition of peroxyacetylnitrate (PAN) to nitrogen oxides (NOx). This result suggests that PAN decomposition in trans-Pacific pollution plumes subsiding over the United States could lead to significant enhancements of surface ozone.

Heald, Colette L.↗

Evaluating Model Performance of an Ensemble-based Chemical Data Assimilation System During INTEX-B Field Mission

We present a global chemical data assimilation system using a global atmosphere model, the Community Atmosphere Model (CAM3) with simplified chemistry and the Data Assimilation Research Testbed (DART) assimilation package. DART is a community software facility for assimilation studies using the ensemble Kalman filter approach. Here, we apply the assimilation system to constrain global tropospheric carbon monoxide (CO) by assimilating meteorological observations of temperature and horizontal wind velocity and satellite CO retrievals from the Measurement of Pollution in the Troposphere (MOPITT) satellite instrument. We verify the system performance using independent CO observations taken on board the NSFINCAR C-130 and NASA DC-8 aircrafts during the April 2006 part of the Intercontinental Chemical Transport Experiment (INTEX-B). Our evaluations show that MOPITT data assimilation provides significant improvements in terms of capturing the observed CO variability relative to no MOPITT assimilation (i.e. the correlation improves from 0.62 to 0.71, significant at 99% confidence). The assimilation provides evidence of median CO loading of about 150 ppbv at 700 hPa over the NE Pacific during April 2006. This is marginally higher than the modeled CO with no MOPITT assimilation (-140 ppbv). Our ensemble-based estimates of model uncertainty also show model overprediction over the source region (i.e. China) and underprediction over the NE Pacific, suggesting model errors that cannot be readily explained by emissions alone. These results have important implications for improving regional chemical forecasts and for inverse modeling of CO sources and further demonstrate the utility of the assimilation system in comparing non-coincident measurements, e.g. comparing satellite retrievals of CO with in-situ aircraft measurements. The work described above also brought to light several short-comings of the data assimilation approach for CO profiles. Because of the limited vertical resolution of the measurement, the retrievals at different altitudes are correlated which can lead to problems with numerical error and overall efficiency. This has resulted in a manuscript that is about to be submitted to JGR:

Arellano, A. F., Jr.↗

Assimilating compact phase space retrievals of atmospheric composition with WRF-Chem/DART: a regional chemical transport/ensemble Kalman filter data assimilation system

This study introduces the Weather Research and Forecasting Model with chemistry/Data Assimilation Research Testbed (WRF-Chem/DART) chemical transport forecasting/data assimilation system together with the assimilation of ''compact phase space retrievals'' of satellite-derived atmospheric composition products. WRF-Chem is a state-of-the-art chemical transport model. DART is a flexible software environment for researching ensemble data assimilation with different assimilation and forecast model options. DART's primary assimilation tool is the ensemble adjustment Kalman filter. WRF-Chem/DART is applied to the assimilation of Terra/Measurement of Pollution in the Troposphere (MOPITT) carbon monoxide (CO) trace gas retrieval profiles. Those CO observations are first assimilated as quasi-optimal retrievals (QORs). Our results show that assimilation of the CO retrievals (i) reduced WRF-Chem's CO bias in retrieval and state space, and (ii) improved the CO forecast skill by reducing the Root Mean Square Error (RMSE) and increasing the Coefficient of Determination ($R^2$). Those CO forecast improvements were significant at the 95 % level. Trace gas retrieval data sets contain (i) large amounts of data with limited information content per observation, (ii) error covariance cross-correlations, and (iii) contributions from the retrieval prior profile that should be removed before assimilation. Those characteristics present challenges to the assimilation of retrievals. This paper addresses those challenges by introducing the assimilation of compact phase space retrievals (CPSRs). CPSRs are obtained by preprocessing retrieval data sets with an algorithm that (i) compresses the retrieval data, (ii) diagonalizes the error covariance, and (iii) removes the retrieval prior profile contribution. Most modern ensemble assimilation algorithms can efficiently assimilate CPSRs. Our results show that assimilation of MOPITT CO CPSRs reduced the number of observations (and assimilation computation costs) by ~ 35 %, while providing CO forecast improvements comparable to or better than with the assimilation of MOPITT CO QORs.

58 GEOSCIENCES↗

EOS Terra Validation Program

The EOS Terra mission will be launched in July 1999. This mission has great relevance to the atmospheric radiation community and global change issues. Terra instruments include ASTER, CERES, MISR, MODIS and MOPITT. In addition to the fundamental radiance data sets, numerous global science data products will be generated, including various Earth radiation budget, cloud and aerosol parameters, as well as land surface, terrestrial ecology, ocean color, and atmospheric chemistry parameters. Significant investments have been made in on-board calibration to ensure the quality of the radiance observations. A key component of the Terra mission is the validation of the science data products. This is essential for a mission focused on global change issues and the underlying processes. The Terra algorithms have been subject to extensive pre-launch testing with field data whenever possible. Intensive efforts will be made to validate the Terra data products after launch. These include validation of instrument calibration (vicarious calibration) experiments, instrument and cross-platform comparisons, routine collection of high quality correlative data from ground-based networks, such as AERONET, and intensive sites, such as the SGP ARM site, as well as a variety field experiments, cruises, etc. Airborne simulator instruments have been developed for the field experiment and underflight activities including the MODIS Airborne Simulator (MAS), AirMISR, MASTER (MODIS-ASTER), and MOPITT-A. All are integrated on the NASA ER-2, though low altitude platforms are more typically used for MASTER. MATR is an additional sensor used for MOPITT algorithm development and validation. The intensive validation activities planned for the first year of the Terra mission will be described with emphasis on derived geophysical parameters of most relevance to the atmospheric radiation community. Detailed information about the EOS Terra validation Program can be found on the EOS Validation program homepage i/e.: http://ospso.gsfc.nasa.gov/validation/valpage.html).

Starr, David↗