Search NASA⌕ Search

SEARCH · Search NASA

Results for “MOTOR-DRIVEN SYSTEMS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Saving Energy: A QuickStart Guide for Small/Medium Manufacturers

The Quick Start Guide aims to serve as an introduction to energy efficiency for small to medium manufacturers, explaining why energy management is important and achievable for all organizations, not just well-resourced, energy-intensive large organizations. It also makes connections to the tools and resources available from DOE to help small to medium manufacturers drive energy savings and sustain the progress. Finally, it provides a list of common energy efficiency opportunities for energy consuming systems such as steam, process heating, and motor-driven systems. Explore the guide to see how smaller manufacturing companies can get started with energy efficiency.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

US DOE In-Plant Trainings to Develop Expertise and Replicate Success

In-Plant Trainings (INPLTs) offered by the US Department of Energy Better Buildings, Better Plants (Better Plants) program are multi-day workshops performed by industry-recognized experts. INPLTs include both classroom- and field-based sessions that train attendees to identify energy conservation opportunities, quantify savings from these opportunities, and implement projects to realize the savings. These training workshops enhance the attendees’ understanding of working principles, knowledge of best practices, and capability to analyze the energy performance of industrial energy systems. INPLTs are competitively awarded and focus on a wide range of topics, including traditional industrial systems such as steam, process heating and motor-driven systems, and processes such as energy treasure hunts and municipal water and wastewater treatment. Partners that are awarded INPLTs can invite external stakeholders, such as employees of other manufacturers, utility representatives, and vendors. The Better Plants program had delivered 123 INPLTs as of spring 2019, trained more than 2,000 participants, and identified more than $37 million in energy cost savings. This paper provides an overview of INPLTs, some key statistics, the top identified energy savings opportunities, and success stories from INPLTs delivered from 2011 to 2018. Finally, the vision for future INPLTs is discussed based on participants’ feedback and the long-term and strategic goals of the Better Plants program.

Guo, Wei↗

Methodology for Estimating Purchased Prices of Energy-efficient Motors Internationally and Results for Selected Countries

Motor-driven systems accounts for approximately 60% of manufacturing final electricity use worldwide. Setting standards and designing policies to increase the energy efficiency of the electric motor stocks in a country is a complex process that requires substantial amount of data and analysis. One of the key data needed for this purpose is the purchase price of electric motors in local market conditions. This study was conducted to develop a bottom-up approach to estimate the purchase price of electric motors in different countries/regions for different sizes, number of poles, enclosures, and efficiency levels by adjusting a recent analysis from the U.S to local parameters. The methodology allows for estimates of manufacturer selling prices, along with other costs associated with the distribution channel to calculate purchase prices for different efficiency levels, in different economies. In this report, we provide preliminary results for selected countries/regions in order to illustrate the possible applications of our analysis. Despite the uncertainties due to specific market conditions, this approach can be used by analysts, industry experts, policy makers, and other interested parties to have a more systematic way to estimate the purchase price of electric motors at the country level and use such prices in cost-benefit analyses and cost-effectiveness of higher energy efficiency standards for electric motors.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Higher Efficiency, Demand Flexible Refrigerator with On-Demand Micro-Vibrational De-icing Technology

Refrigerator technology has advanced significantly over the last couple of decades. Today’s refrigerators use only about 25% of the energy that was required to power models built in 1975. Even as they continually improve efficiency to meet standards, refrigerators have increased in size by almost 20%, added energy-consuming features such as through-the-door ice, and provide more benefits than ever before. However, a few challenges and technology gaps are preventing further improvement of the demand responsiveness and efficiency of the refrigerators. One of the major technology gaps in existing refrigerators is their outdated de-icing process. When the evaporator generates frost, an old-fashioned resistive heating element melts the ice. Most refrigerators have a timed defrost cycle, rather than an active system that could monitor the state of the frost. In these systems, not only is the precious electricity used at its least efficient form of conversion (direct conversion of electricity to heat), but also all the latent heat associated with the ice is wasted during the melting process. On top of that, the refrigerator needs to work harder to pull the temperature down after defrosting, and, last but not least, the food quality is severely impacted by the temperature swings during the defrost cycle. According to a study, the EU alone wastes 89 million tons of food in the supply chain every year. Any temperature swing during defrosting (about 6F according to Emerson for low-temperature cases) can negatively impact the shelf life of meat and other products for multiple days. All these issues can happen during the peak demand time of the electric grid. Unlike the conventional systems, the proposed novel advanced micro-vibrational deicing process uses no heat for defrosting. Instead, it uses the micro vibrations generated by a piezoelectric or vibration-generating module to mechanically break ice from the heat exchanger almost instantaneously. The project titled “Higher Efficiency, Demand Flexible Refrigerator with On-Demand Micro-Vibrational De-icing Technology, performed by Ultrasonic Technology Solutions, LLC (UTS) of Knoxville, TN, in collaboration with Emerson (now Copeland), represents the final phase of a multi-year effort funded under the U.S. Department of Energy’s Building Technologies Office (BTO) BENEFIT FOA 2020. Initiated on October 1, 2021, and completed after a nine-month no-cost extension ending September 30, 2025, this project aimed to develop and validate a novel micro-vibrational mechanical defrosting system, achieving more than 25% improvement in defrosting energy efficiency over conventional baseline defrosting technologies. Over sixteen quarters, the project advanced from fundamental ice-mechanical characterization and prototype development to full-scale system integration and validation. Initial efforts established project management infrastructure and characterized ice adhesion properties, followed by the design and fabrication of early aluminum-based prototypes for resonance frequency testing. Subsequent quarters saw rapid technical progression, including the identification of optimal piezoelectric and motor-based vibration mechanisms, the demonstration of effective de-icing over 6x6-inch aluminum surfaces. The team achieved its Go/No-Go milestone by exceeding the 25% energy-efficiency improvement target—reaching up to 3,340% under optimized conditions—and later confirmed that motor-driven systems offered superior performance and energy efficiency compared to piezoelectric alternatives. Continued refinement led to the development of amplifier systems on printed circuit boards, improved control and instrumentation hardware, and integration into full-scale heat exchanger (HX) prototypes at both UTS and Copeland facilities. Multiple vibration-mounting studies and frost-growth experiments guided mechanical optimization and noise-mitigation strategies, achieving a 17.5 dB reduction in sound pressure level and verifying robust mechanical performance. Advanced analyses, including modal and harmonic simulations, established a quantitative understanding of vibrational behavior and de-icing efficiency across >1000 cm² systems. The final project phase successfully demonstrated scalable integration within reach-in and chest freezer prototypes, confirmed >25% efficiency improvements in large-area systems, and completed a comprehensive business model and scale-up strategy identifying electric defrost systems as the primary beachhead market. The culmination of this DOE-supported effort establishes micro-vibrational defrosting as a viable, high-efficiency, low-noise, and demand-flexible de-icing technology, paving the way for commercial deployment and broader application in next-generation refrigeration systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Improvements to In-Canal Assay of High Specific Activity 60Co at the ATR

Improvements to the quality of measurements in the assaying of High Specific Activity (HSA) cobalt 60 produced at the Advanced Test Reactor at the Idaho National Laboratory are presented. Such assays are conducted regularly between cycles at the ATR, and due to the radiological safety concerns, they are performed within the ATR canal. A standard ion chamber detector was placed in a collimated assay tube within the canal. Another tube, parallel to the detector, was used to position various cobalt 60 standards and targets. The collimated port between these tubes allows for the targets to be pulled across via a winch system. Previous measurements were performed at discrete 1.5-inch steps using a hand-cranked winch system. Charge was collected and integrated for 10 seconds at each discrete step during a scan. Two substantial improvements to the assay include an electronically controlled, motor-driven winch system and a software controlled continuous charge collection. Combined, these changes improved the quality of measurements as well as streamline the assay process. Further examination of these charge profiles indicated a reasonable amount of photon scattering, or shine, before a line-of-sight is established. This created inaccuracies in the reported activity of the cobalt targets. A series of MCNP-6.3 calculations were performed in an effort to quantify and correct for this shine effect. The results of the calculations and how they were employed to a create shine correction factor for the in-canal cobalt assay at the ATR are presented. The overall bias showed an overestimation of the HSA cobalt 60 activity by around 7-8%.

07 - ISOTOPES AND RADIATION SOURCES↗

Coupling Power System Dynamics and Building Dynamics to Enable Building-to-Grid Integration

The interactions between power system dynamics and building dynamics are usually ignored or over-simplified in existing power systems and building modeling and simulation tools, which limits how system modeling can sup-port Building-to-Grid integration. This paper discusses a new approach to consider those interactions by model-ing motor-driven building devices or systems. The motor-driven model is based on simplified mechanical rotation equations and allows us to study the coupling relationship between frequency/voltage in the power system and motor-driven device operation. This model is validated by performing one proof-of-concept case study with Modelica. The simulation results suggest that the proposed model can yield better representations of these interactions than the existing simplified models, especially the ones with the fast transient dynamics.

Buildings-to-grid integration, motor, coupling sim↗

Enhanced Component Performance Study: Motor-Driven Pumps 1998–2016

This report presents an enhanced performance evaluation of motor-driven pumps (MDP) at U.S. commercial nuclear power plants. The data used in this study are based on the operating experience failure reports from calendar year 1998 through 2016 for the component reliability as reported in the Institute of Nuclear Power Operations (INPO) Consolidated Events Database (ICES). The motor-driven pump failure modes considered for standby systems are failure to start, failure to run less than or equal to one hour, and failure to run more than one hour; for normally running systems, the failure modes considered are failure to start and failure to run. An eight hour unreliability estimate is also calculated and trended. The component reliability estimates and the reliability data are trended for the most recent 10-year period while yearly estimates for reliability are provided for the entire active period. Highly statistically significant increasing trend was identified in normally running MDP run hours per reactor year.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Deployable UHV Pump

This project presents an external motorized actuation system for a deployable ultra-high vacuum (UHV) pump, enabling internal motion without compromising vacuum conditions. All active components remain external due to environmental and space constraints. A motor-driven mechanical feedthrough transfers motion into the pump, supported by a modular, adjustable mounting system that maintains alignment and integrates with existing hardware. CAD modeling and iterative design were used to refine geometry and ensure proper fit. The final design reliably transfers motion while maintaining alignment and structural integrity. Its adjustability improves installation and maintenance, demonstrating a practical solution for actuation in UHV systems.

Remington, Austin [Northern Illinois U.]↗

Artificial Reasoning System for Symptom-Based Conditional Failure Probability Estimation Using Bayesian Network

Advances in nuclear power technologies require enhanced capabilities for operator advice and autonomous control. One of the first tasks in the development of such capabilities is the formulation of symptom-based conditional failure probabilities for structures, systems, and components (SSCs) of interest, for which the primary goal is to aid plant personnel in deducing the probabilistic performance status of the monitored SSCs and in detecting impending faults/failure. The task of conditional failure probability estimation is a bidirectional inference problem and shall be logically tackled by the Bayesian network (BN) approach. As a knowledge-based artificial intelligence tool and a probabilistic graphical model, BN offers the capability of reasoning under uncertainty and graphical representation emulating the physical behavior of the target SSC. This paper provides a systematic overview of the BN technique and the software tools for handling implementation of BN models, along with the associated knowledge representation and reasoning paradigm. Both operational data and expert judgement can be readily incorporated into the knowledge base of a BN model. The challenges with data availability are highlighted, and the general approach to target SSC identification is presented. Our focus is upon failure-prone and risk-important balance of plant assets, especially cases having strong operator involvement. An exemplary case study on the failure of a motor-driven centrifugal pump is also conducted to demonstrate the usefulness and technical feasibility of the proposed artificial reasoning system using an expert system shell.

Zhao, Xingang↗

LIQUID AIR COMBINED CYCLE

Hybrid integration of thermal energy storage with gas turbines can provide compact, cost-effective, long-duration energy storage while reducing the fuel consumption of dispatchable resources needed for the reliability of renewable dominant electric grids. The Liquid Air Combined Cycle™ (LACC) is a hybrid energy storage system using cryogenic liquid air as an energy storage medium and gas turbine exhaust heat to extract stored energy. The storage tank is charged using liquefaction processes employing electric motor-driven compressors to pressurize the air, heat exchangers to reject heat of compression, and expanders to reduce the temperature and liquefy the air. Proven cryogenic refrigeration processes can be selected based on capital cost (per kg/s of liquid air produced), efficiency (kJ per kg of air produced), and operating factors including startup speed and load following capability. This paper presents results of studies undertaken for the U.S. Department of Energy to evaluate cost and performance tradeoffs for charge and discharge cycle components, optimize charge and discharge cycles, and assess the techno-economic potential of LACC technology.

Conlon, William↗

Enhanced Component Performance Study: Motor-Driven Pumps 1998-2020

This report presents an enhanced performance evaluation of motor-driven pumps (MDPs) at U.S. commercial nuclear power plants. The data used in this study are based on the operating experience failure reports from calendar year 1998 through 2020 as reported in the Institute of Nuclear Power Operations (INPO) Industry Reporting and Information System (IRIS). The MDP failure modes considered for standby systems are fail to start (FTS), fail to run (FTR) for one hour of operation (FTR≤1H), FTR after one hour of operation (FTR>1H), and for normally running systems FTS and FTR. An eight-hour unreliability estimate is also calculated and trended. The component reliability estimates and the reliability data are trended for the most recent 10-year period while yearly estimates for reliability are provided for the entire study period. The following increasing trends were identified for MDPs for the most recent 10-year period: • Standby MDP frequency of start demands (demands per reactor year) • Standby MDP frequency of FTR≤1H hours (hours per reactor year) • Standby MDP frequency of FTR>1H hours • Normally running MDP frequency of run hours. The following decreasing trends were identified for MDPs for the most recent 10-year period: • Standby MDP FTR≤1H failure probability • Normally running MDP FTR failure rate • Standby MDP unavailability • Normally running MDP total unreliability (8-hour mission) • Standby MDP frequency of FTR≤1H events (failures per reactor year) • Normally running MDP frequency of FTR events.

99 GENERAL AND MISCELLANEOUS↗

Self-Powered Autonomous Sensing System for Arctic Ocean using a Frequency-multiplied Cylindrical Triboelectric Nanogenerator

An autonomous sensing system for collecting environmental observations in the Arctic region is critical for the estimation and prediction of climate change. Ocean waves are a great source of energy for these sensing systems but there has been limited research done on small-scale energy harvesting applications in the Arctic Ocean (subsea or surface). The available wave energy in the Arctic Ocean is lower than the typical ocean wave energy due to the low wave frequency, height, and operating months. Although the available wave energy depends on the specific location in the Arctic Ocean, the wave height decreases everywhere during the winter (Jan-March) [1]. Our target location in this work is the Beaufort and Chukchi Seas, which are ice covered for about 195 days per year leaving only a few months (June-November) for wave energy harvesting [2]. During these few months, the average wave frequency is 0.2 Hz and the most common wave frequency is around 0.15 Hz. Many energy harvesting methods are unsuitable for use in the Arctic Ocean because of to the cold temperature, low wave frequency, and low wave height. Triboelectric nanogenerators (TENG) are one of the few energy harvesting methods that excel in these conditions. Zhong et al. [3] designed a stacked pendulum-structured TENG for low-frequency ocean wave energy and reported the device generated a peak power density of 11.2 W/m3 under the low wave frequency of 0.2 Hz. The autonomous sensing system we developed for the Arctic Ocean, the Arctic-TENG, is based on a frequency-multiplied cylindrical TENG (FMC-TENG) which is an optimized TENG configuration for Arctic Ocean conditions due to the high power density under low-frequency wave conditions [4]. Figure 1 shows an FMC-TENG with multiple pairs of free-standing triboelectric-layer mode materials (Aluminum and FEP). The mass and magnet attached to the rotor store gravitational potential energy which is released as kinetic energy when the potential energy overcomes the repulsive magnetic force generated by the opposing magnet attached to the stator. This force unbalance triggers a sudden rotation and swinging motion of the mass which increases the angular velocity of the system and therefore enhances the output power of the TENG system. The main components of the Arctic-TENG are a 3D-printed rotor and stator, electric and dielectric material adhesive tape, and bearings. All these materials were cold-soaked and tested at -40 °C in a chest freezer. Both the 3D-printed parts and adhesives were confirmed to have a minimal effect from the cold temperature. Multiple bearings were tested and the starting torque of each one was compared both at room temperature and -40 °C. The bearing with the lowest starting torque at -40 °C was selected for use in the Arctic-TENG. The Arctic-TENG was tested using an out-of-water motor-driven wave simulator (Figure 2). The wave simulator allows for controlled testing at a wave height of 0.2 m and frequencies between 0.1 Hz to 0.5 Hz. This wave simulator was used for both room temperature and -40 °C testing. The Arctic-TENG generated significantly more power at -40 °C compared to room temperature for each frequency tested. The system stored energy in a supercapacitor via a power management circuit, and the amount of energy stored per day was calculated at different wave frequencies. Based on the conditions at the proposed deployment location (days of non-ice-covered ocean and wave frequency), the amount of stored energy per year from Arctic-TENG was calculated to be enough energy for two transmissions every day. Durability testing was completed on the Arctic-TENG at room temperature to determine the lifetime. The rotor of the Arctic-TENG was attached to a DC motor and spun continuously for several millions of cycles without degradation of the electrical output, demonstrating the feasibility for long-term operation.

Jung, Hyunjun↗

Enhanced Component Performance Study: Motor Driven Pumps 1998–2022

This report presents an enhanced performance evaluation of motor-driven pumps (MDPs) at U.S. commercial nuclear power plants. The data used in this study are based on the operating experience failure reports from calendar year 1998 through 2022 as reported in the Institute of Nuclear Power Operations (INPO) Industry Reporting and Information System (IRIS). The MDP failure modes considered for standby systems are fail to start (FTS), fail to run (FTR) for one hour of operation (FTR=1H), FTR after one hour of operation (FTR>1H), and for normally running systems FTS and FTR. An eight-hour unreliability estimate is also calculated and trended. The component reliability estimates and the reliability data are trended for the most recent 10-year period while yearly estimates for reliability are provided for the entire study period. The following increasing trends were identified for MDPs for the most recent 10-year period: (1) Standby MDP frequency of start demands (demands per reactor year), (2) Standby MDP frequency of FTR=1H hours (hours per reactor year), (3) Standby MDP frequency of FTR>1H hours, and (4) Normally running MDP frequency of run hours. The following decreasing trends were identified for MDPs for the most recent 10-year period: (1) Standby MDP FTR=1H failure probability, (2) Normally running MDP FTR failure rate, (3) Standby MDP unavailability, (4) Standby MDP total unreliability (8-hour mission), and (5) Normally running MDP total unreliability (8-hour mission).

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Enhanced Component Performance Study: Motor Driven Pumps 1998-2024

This report presents an enhanced performance evaluation of motor-driven pumps (MDPs) at U.S. commercial nuclear power plants. The data used in this study are based on the operating experience failure reports from calendar year 1998 through 2024 as reported in the Institute of Nuclear Power Operations (INPO) Industry Reporting and Information System (IRIS). The MDP failure modes considered for standby systems are fail to start (FTS), fail to run (FTR) for one hour of operation (FTR=1H), FTR after one hour of operation (FTR>1H), and for normally running systems FTS and FTR. An eight-hour unreliability estimate is also calculated and trended. The component reliability estimates and the reliability data are trended for the most recent 10-year period while yearly estimates for reliability are provided for the entire study period.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A Custom Machine to Convey Radiologically Impacted Cohesive Soils to the Orion ScanSortSM System - 20382

An established method to reduce the volume of material required to be disposed of as radioactive waste is conveyor-based sorting of potentially radiologically impacted soils. With the Orion ScanSortSM system, potentially impacted soils are conveyed beneath radiation detectors and sorted into above and below criteria bins based on the detectors' response. Confident measurements can only be efficiently achieved when the soil column being conveyed has a reasonably consistent geometry. Highly cohesive soils present a very significant challenge as they tend to clump and adhere to the conveyor hopper, strike-off bar, and belt skirting. This causes voids and valleys in the soil column that affect the measurement geometry and reduce the confidence in the measurement. The reduction in confidence necessitates a longer residence time (i.e. reduction in conveyor belt speed and processing rates) or that the soils in highly unfavorable geometries be dispositioned as impacted or segregated for resurvey (should site logistics support that option). These outcomes may increase the volume of material required to be dispositioned as radiological waste and have a negative impact on project cost and schedule. To minimize impact to sorting operations, Wood designed and built a customized Extruder, to optimize the soil column prior to assay. The design was developed and refined to minimize the volume of highly cohesive soils presented in highly unfavorable geometries in the soil column in order to confidently assess and disposition such soils in a high-production environment. The Extruder is a customized 90 cm wide flat conveyor that has an oversized hopper with a pair of motor-driven rollers that force the soils in the hopper through an opening of adjustable height. The soils are extruded through the opening to produce a soil column that is ∼75 cm wide and ∼8-18 cm deep with a design rate of 225 metric tons/hr. The Extruder was recently deployed with the Orion ScanSort{sup SM} System to a site in northeast Ohio. The site has highly cohesive soils that result from the weathering of glacial sediments and consist of clay and clay loam, resulting in poor drainage and high moisture content. The project infrastructure only supported two bins of material (above and below criteria), which necessitated that soils with unfavorable geometries be discharged into the above criteria bin, along with material determined to have been contaminated. The Extruder was extremely successful in producing a stable soil column with favorable geometries for radiological assay. During production, less than 0.5% (by mass) of the soils processed were presented in unsatisfactory geometries requiring disposition as radioactive waste. The Extruder did not get clogged due to the cohesive soils (as is typical with conventional conveyors) and required very little maintenance, again minimizing impacts to sorting operations. The conveyor belt speed was operated at 14 cm/s with a typical belt loading of ∼109 kg/m resulting in a mean process rate of ∼49 metric tons/hr. The process rate was constrained by other project logistics, rather than by the capabilities of the Extruder, which was operated at less than 20% of the maximum design speed (75 cm/s). It is concluded that the Extruder is highly likely to produce a stable highly cohesive soil column suitable for efficient and confident radiological assay in production environments of 250 short tons/hr or more. The Extruder has the capability to drastically reduce the duration and costs of projects with radiologically impacted highly cohesive soils. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Strain Distributions and Structural Changes in Motor Driven Gels (Final Report)

The goal of this project was to study the effects of DNA-based, force-generating motor proteins on the structure and dynamics of a DNA hydrogel. Motor proteins are nanoscale transducers, converting chemical energy embedded in the solution into local mechanical work on hydrogel strands, and thus potentially driving structural changes and/or non-equilibrium dynamics within the gel material. To explore this, we used self-assembly to create condensed DNA phases, and activated the phases with proteins. The specific aim was to study the deformations (strain fields) generated within a DNA gel by motor forces. We succeeded in this aim, developing methods to experimentally create gel/motor systems, and measure strain with high spatio-temporal resolution. A key finding was that simple continuum strain-field models fail to describe the data. A second major outcome was the development of novel models of hydrogel elasticity incorporating solvent effects that can be used to model dynamic motor-driven strains. A third major outcome was to learn how to control the phase and structure of condensed DNA particles, including both liquid-crystalline behavior, and the formation of DNA liquids.

59 BASIC BIOLOGICAL SCIENCES↗

Modeling of Vertical Motor-driven Pump for Simulation of a Fault Signature \\ for Condition Monitoring

As part of the ongoing effort to transition from preventive maintenance strategies to condition-based maintenance strategies in nuclear power plants, there is significant reliance on using machine learning techniques. To develop a robust machine learning model that can diagnose all the fault modes of a vertical motor-driven pump, data capturing the unique signature of each fault mode is required. In practice, it is difficult to collect or capture data that captures all the fault modes from a single plant site. So to address this situation, a computational model of a vertical motor-driven pump is developed using the multipurpose finite element software COMSOL Multiphysics. The developed model is used to generate simulated data under normal operation and is compared with the vibration data collected using vibration sensors. Once the simulation model is verified under normal operating condition, simulated data for the fault mode for which minimal or no evidence is available in historical plant process data is developed. This simulated data is used to develop fault signatures to achieve robust predictive models. This paper presents modeling details and verification of the model that can used to generate data for fault modes that are not available at a plant site for condition monitoring purpose.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Modeling of Vertical Motor-driven Pump for Simulation of a Fault Signature \\ for Condition Monitoring

As part of the ongoing effort to transition from preventive maintenance strategies to condition-based maintenance strategies in nuclear power plants, there is significant reliance on using machine learning techniques. To develop a robust machine learning model that can diagnose all the fault modes of a vertical motor-driven pump, data capturing the unique signature of each fault mode is required. In practice, it is difficult to collect or capture data that captures all the fault modes from a single plant site. So to address this situation, a computational model of a vertical motor-driven pump is developed using the multipurpose finite element software COMSOL Multiphysics. The developed model is used to generate simulated data under normal operation and is compared with the vibration data collected using vibration sensors. Once the simulation model is verified under normal operating condition, simulated data for the fault mode for which minimal or no evidence is available in historical plant process data is developed. This simulated data is used to develop fault signatures to achieve robust predictive models. This paper presents modeling details and verification of the model that can used to generate data for fault modes that are not available at a plant site for condition monitoring purpose.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗