Commercialization of the Micro Pocket Fission Detector (MPFD) - Phase I Final Report
Explore the source record for details and available documents.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
The Micro-Pocket Fission Detector (MPFD) is a small-form–factor real-time fission chamber. MPFD performance has been simulated in the Advanced Test Reactor Critical Facility (ATRC), located at Idaho National Laboratory (INL). Here, the neutron and gamma-ray flux profiles and magnitudes were simulated using Monte Carlo N-Particle (MCNP) in the near-core B-8 irradiation position. These simulations were performed at 69 discrete axial locations inside the B-8 position for three separate orientations of the nearby hafnium outer shim control cylinders and at a power level of 700 Wth. The resulting neutron and gamma-ray flux values were used to determine the MPFD response for various fissile masses and detector gas pressures. The optimal gas-operating pressure was determined to be between 30 and 60 psig. The required fissile-layer mass was determined to be between 1–2 µg of 235 U. Additionally, the gamma-ray to fission-fragment interaction rate was determined to be 4.42 × 10 -3 with average energy deposition for gamma rays and fission fragments in 30 psig argon gas to be 1 keV and 9.5 MeV, respectively.
This report documents the comparative assessment of the rhodium-based self-powered neutron detectors (Rh-SPND), micro-pocket fission detectors (MPFD), and dosimetry wires in heated irradiations at the Neutron Radiography reactor facility at Idaho National Laboratory. The sensors performances are evaluated high-temperature environments (upwards of 850°C) during maximum reactor power to simulate use in advanced reactor applications. The performance of the Rh-SPNDs indicates the experiment cartridge heater power supply interferes with the SPND signals. This interference become increasingly significant at temperatures above 500°C with minimal interference observed for temperatures below 500°C. This work also demonstrated the fabrication process for the updated design of the MPFD, but issues related to the seal welds were identified and usable data was limited. Finally, the dosimetry measurements were within the expected range correlated with reactor power; thus, the dosimetry results were used to provide preliminary SPND calibration factors. The results from this experiment serves as a reference for developing and testing of flux sensors that are designed for high-temperature irradiations and advanced reactor deployments. This includes upcoming FY22 irradiations at the Massachusetts Institute of Technology Reactor and the Neutron Radiography (NRAD) reactor utilizing additional fission chambers from Photonis Technologies and fission chambers and SPNDs from The French Alternative Energies and Atomic Energy Commission.
This report documents the testing of two in-core fission chamber technologies for high-temperature irradiation environments. This work is in collaboration with the French Alternative Energies and Atomic Energy Commission (CEA). The fission chamber evaluated by Idaho National Laboratory is the micro-pocket fission detector (MPFD). The fission chamber evaluated by the CEA are the 3 mm miniaturized fission chamber and the 7 mm high-temperature fission chamber. Demonstrations of the MPFD were performed at the Neutron Radiography Facility and the Massachusetts Institute of Technology Reactor. Demonstrations of the CEA fission chambers were performed at the Ohio State University Research Reactor. All demonstrations were conducted with a heated experiment rig up to 850°C.
According to the continuous development of metal-oxide semiconductor (MOS) fabrication technology, transistors have naturally become more radiation-tolerant through steadily decreasing gate-oxide thickness, increasing the tunneling probability between gate-oxide and channel. Unfortunately, despite this radiation-hardened property of developed transistors, the field of nuclear power plants (NPPs) requires even higher radiation hardness levels. Particularly, total ionizing dose (TID) of approximately 1 Mrad could be required for readout circuitry under severe accident conditions with 100 Mrad around a reactor in-core required. In harsh radiating environments such as NPPs, sensors such as micro-pocket-fission detectors (MPFD) would be a promising technology to be operated for detecting neutrons in reactor cores. For those sensors, readout circuits should be fundamentally placed close to sensing devices for minimizing signal interferences and white noise. Therefore, radiation hardening ability is necessary for the circuits under high radiation environments. This paper presents various integrated circuit designs for a radiation hardened charge-sensitive amplifier (CSA) by using SiGe 130 nm and Si 180 nm fabrication processes with different channel widths and transistor types of complementary metal-oxide-semiconductor (CMOS) and bipolar CMOS (BiCMOS). These circuits were tested under γ–ray environment with Cobalt-60 of high level activity: 490 kCi. The experiment results indicate amplitude degradation of 2.85%–34.3%, fall time increase of 201–1730 ns, as well as a signal-to-noise ratio (SNR) of 0.07–11.6 dB decrease with irradiation dose increase. These results can provide design guidelines for radiation hardening operational amplifiers in terms of transistor sizes and structures.