Search NASA⌕ Search

SEARCH · Search NASA

Results for “MS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Isotopic analysis of Nd nanoparticles using single particle MC-ICP-MS: A comparative study with single particle-ICP-TOF-MS

Single particle - inductively coupled plasma - mass spectrometry (SP-ICP-MS) is a powerful technique for characterization of the elemental and isotopic composition of individual particles. In this work, the capabilities of the newest generation of MC-ICP-MS with acquisition rates down to 50 ms were evaluated for single particle analysis, with a focus on isotopic precision achievable on a single-particle level. Nd (NdVO 4 ) nanoparticles (~120 nm in diameter) were used as case study and were first characterized in terms of mass (respective size) and particle number concentration by SP-ICP-TOF-MS and then by SP-MC-ICP-MS for isotopic precision. For the isotopic ratio measurements, the MC-ICP-MS performance was compared to the ICP-TOF-MS and it was found that the isotope ratio precision was increased (R 2 between 0.98 and 0.99) compared to ICP-TOF-MS (R 2 between 0.88 and 0.97). The accuracy attained on a single particle level, was compared to bulk digestion followed by MC-ICP-MS analysis, and the SP-MC-ICP-MS technique was able to determine the particle population average to be <4 %, percent relative differences for the 142 Nd/ 144 Nd, 143 Nd/ 144 Nd, 145 Nd/ 144 Nd, 146 Nd/ 144 Nd, and 148 Nd/ 144 Nd ratios The detection limit for the SP-MC-ICP-MS approach was also assessed. Here, when utilizing an all Faraday-cup based detection scheme the determined LOD for the measurements was 0.2fg for Nd, per particle. Based on these results, the newest generation of MC-ICP-MS has demonstrated its utility for performing SP measurement, particularly when high precision isotopic determination is warranted.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Analysis, identification and confirmation of synthetic opioids using chloroformate chemistry: Retrospective detection of fentanyl and acetylfentanyl in urine and plasma samples by EI-GC-MS and HR-LC-MS

Electron Impact Gas Chromatography-Mass Spectrometry (EI-GC-MS) and High Resolution Liquid Chromatography-Mass Spectrometry (HR-LC-MS) have been used in the analysis of products arising from the trichloroethoxycarbonylation of fentanyl and acetylfentanyl in urine and plasma matrices. The method involves the initial extraction of both synthetic opioids separately from the matrices followed by detection of the unique products that arise from their reaction with 2,2,2-trichloroethoxycarbonyl chloride (Troc-Cl), namely Troc-norfentanyl and Troc-noracetylfentanyl. The optimized protocol was successfully evaluated for its efficacy at detecting these species formed from fentanyl and acetylfentanyl when present at low and high levels in urine (fentanyl: 5 and 10 ng/mL and acetylfentanyl: 20 and 100 ng/mL) and plasma (fentanyl: 10 and 20 ng/mL and acetylfentanyl: 50 and 200 ng/mL), values that reflect levels reported in overdose victims. The HR-LC-MS method’s LOQ (limit of quantitation) for the Troc-norfentanyl and Troc-noracetylfentanyl products was determined to be ~10 ng/mL for both species. Even though the superiority in the detection of these species by HR-LC-MS over EI-GC-MS, the latter method proved to be important in the detection of the second product from the reaction, namely 2-phenylethyl chloride that is crucial in the determination of the original opioid. This observation highlights the importance of using complimentary analytical techniques in the analysis of a sample, whether biological or environmental in nature. The method herein serves as a complementary, qualitative confirmation for the presence of a fentanyl in collected urine, plasma and by extension other biological samples amenable to the common extraction procedures described for opioid analysis. More importantly, the method’s main strength comes from its ability to react with unknown fentanyls to yield products that can be not only detected by EI-GC-MS and HR-LC-MS but can then be used to retrospectively identify an unknown fentanyl.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Identification of Serine-Containing Microcystins by UHPLC-MS/MS Using Thiol and Sulfoxide Derivatizations and Detection of Novel Neutral Losses

Microcystins (MCs) are hepatotoxic cyclic heptapeptides produced by cyanobacteria, and their structural diversity has led to the discovery of more than 300 congeners to date. However, with known amino acid combinations, many more MC congeners are theoretically possible, suggesting many remain unidentified. Herein, two novel serine (Ser)-containing MCs were putatively identified in a Lake Erie cyanobacterial harmful algal bloom (cyanoHAB), using high-resolution UHPLC-MS as well as thiol and sulfoxide derivatization procedures. These MCs contain an α,β-unsaturated carbonyl on methyl dehydroalanine (Mdha) residue that undergoes Michael addition to produce a thiol-derivatized MC. Derivatization reactions using various thiolation reagents were followed by MS/MS, and two Python codes were used for data analysis and structural elucidation of MCs. Two novel MCs containing Ser at position 1 (i.e., next to Mdha) were putatively identified as [Ser 1 ]MC-RR and [Ser 1 ]MC-YR. Using thiol- and sulfoxide-modified [Ser 1 ]MCs, identifications were confirmed by the observation of specific neutral losses of the oxidized thiols or sulfoxides in CID-MS/MS spectra in both positive and negative electrospray ionization (ESI) modes. These novel neutral losses are unique for MCs with Mdha and an adjacent Ser residue. In conclusion, data suggest that a gas-phase reaction occurs between oxygen from adjacent Ser residue and sulfur of the Mdha-bonded thiol or sulfoxide, which leads to the formation and detection of stable cyclic MC ions in MS/MS spectra at m/z values corresponding to the loss of oxidized thiols or oxidized sulfoxides from Ser 1 -containing MCs.

Premathilaka, Sanduni H.↗

Identification of Novel Microcystins Using High-Resolution MS and MS n with Python Code

Cyanotoxins called microcystins (MCs) are highly toxic and can be present in drinking water sources. Determining the structure of MCs is paramount because of its effect on toxicity. Though over 300 MC congeners have been discovered, many remain unidentified. In this work, a method is described for the putative identification of MCs using liquid chromatography (LC) coupled with high-resolution (HR) Orbitrap mass spectrometry (MS) and a new bottom-up sequencing strategy. Maumee River water samples were collected during a harmful algal bloom and analyzed by LC–MS with simultaneous HRMS and MS/MS. Unidentified ions with characteristic MC fragments (135 and 213 m/z) were recognized as possible novel MC congeners. An innovative workflow was developed for the putative identification of these ions. Python code was written to generate the potential structures of unidentified MCs and to assign ions after the fragmentation for structural confirmation. The workflow enabled the putative identification of eight previously reported MCs for which standards are not available and two newly discovered congeners, MC-HarR and MC-E(OMe)R.

54 ENVIRONMENTAL SCIENCES↗

Gas‐Phase Ion‐Molecule Interactions in a Collision Reaction Cell with ICP‐MS / MS : Investigations with CO 2 as the Reaction Gas

Carbon dioxide (CO 2 ) was used as a reaction gas to investigate the gas‐phase ion‐molecule interactions using the Agilent 8900 ICP‐MS/MS. A solution containing forty‐five elements representative of the periodic table was used to supply the ions to react with CO 2 in the collision/reaction cell (CRC). The only significant product ions formed were monoxides. The general reactivity was shown to be consistent with density functional theory (DFT)‐predicted reaction enthalpies, such that all predicted exothermic reactions produced product ions at levels of at least 1% of the unreacted ion. Most endothermic reactions observed had sufficient kinetic energy in excess of the reaction enthalpies. Our results suggest that reaction enthalpy is a reasonable predictor of reactivity with CO 2 on the timescales of the interactions in non‐thermal ICP‐MS/MS systems. The ease and rapidity of data collection with the ICP‐MS/MS and DFT calculations using the NWChem suite has value given the scarcity of thermochemical data of CO 2 reactions in the literature. These studies are especially useful for the identification of targeted reaction chemistries to be leveraged for analytical method development, such as for the inline separation of isobaric interferences from analytes of interest.

36 MATERIALS SCIENCE↗

EI_MS_ML

The unambiguous identification of compounds from their electron ionization mass (EI-MS) spectra remains a significant unsolved problem in the field of metabolomics and analytical chemistry as a whole. Typically EI-MS spectra are compared using various mathematical operations that convert the spectral similarity or differences into a distance-like metric that roughly approximates the similarity of any two spectra. A commonly used metric for this is the cosine similarity metric which has values close to one for very similar spectra and a value of zero for very dissimilar spectra; however, no metric is perfect. Due to the prevalence of structurally-similar compounds such as isomers and the prevalence of certain fragmentation patterns across structurally-dissimilar compounds, the unambiguous assignment of EI-MS spectra compounds remains difficult. Frequently, querying an observed EI-MS spectrum against a large database such as the NIST17 library yields multiple possible assignments requiring the end user to distinguish between multiple high scoring hits, or multiple low scoring hits while keeping in mind that the correct hit may not be in the database at all. Although techniques such as orthogonal information from techniques such as chromatography can greatly aid in unambiguous assignment, this also requires more complicated experimental designs and access to more complicated analytical instrumentation. Substructures can be trivially detected and represented as strings using a previously published technique called node coloring from a known chemical structure. However, for experimentally-derived EI-MS spectra this information must be derived from the spectra itself (i.e., because we do not know what compound it represents). To achieve this, the software uses techniques from the field of machine learning and a large training dataset of EI-MS spectra corresponding to known structures annotated with substructure strings, to build models that can predict the presence of a given chemical substructure from an EI-MS spectrum directly.If these predictions are of high-quality (i.e., are unlikely to be false positives), the presence of one or more predicted substructures can be used to constrain the number of possible hits for a query spectrum. Mathematically, this restriction could be expressed in many forms, but the most straight-forward implementation is to weight the cosine similarity of a query spectrum and a plausible database match with a Tanimoto-like coefficient based on the ratio of the number of substructures predicted to the number of substructures present in the potential database hit. Determining which combination of models best reduces assignment ambiguity will be achieved using a combination of manual curation and optimization techniques such as genetic algorithms. This software will perform all the steps necessary to construct said models from a training dataset and evaluate them using a holdout dataset. Various statistical analyses can be performed to determine if this approach does decrease assignment ambiguity. For example, if this approach works, on average, the rank-order of the correct assignment for the holdout set of EI-MS spectra should decrease and the weighted cosine similarities for most of the possible matches in the database should be better than the unweighted cosine similarities. Furthermore, this same pipeline can be used on real experimental data to generate less ambiguous assignments.

Mitchell, Joshua↗

Assessment of Low-Level Pu Isotope Ratio Measurements Using Multicollector Inductively Coupled Plasma Mass Spectrometry (MC-ICP-MS/MS) Equipped with a Pre-Mass Filter

We present an initial investigation into the performance of a multicollector inductively coupled plasmamass spectrometer equipped with a pre-mass filter (Neoma MC-ICP-MS/MS) for making plutonium (Pu) isotope ratio measurements on solutions containing low level (i.e., pg mL –1 ) Pu concentrations. This assessment was achieved by comparison of the 240 Pu/ 239 Pu, 241 Pu/ 239 Pu, and 242 Pu/ 239 Pu ratios attained over a one month period on the MC-ICP-MS/MS with the long-term (∼1 year) performance observed on the predecessor MC-ICP-MS (Neptune Plus) instrument each equipped with an equipped with an APEXΩ desolvating nebulizer for repeated measurements of certified reference materials from New Brunswick Program Office (NBL PO) CRM 136a and CRM 137. The MC-ICP-MS/MS performance of repeated measurement of CRM 136a (n = 20) resulted in mean values of 240 Pu/ 239 Pu = 0.1448 ± 0.0006, 241 Pu/ 239 Pu = 0.00371 ± 0.00006, and 242 Pu/ 239 Pu = 0.00682 ± 0.00006 (k = 2). The CRM 137 (n = 20), analyzed during the same analytical sessions, produced mean values for 240 Pu/ 239 Pu = 0.2414 ± 0.0006, 241 Pu/ 239 Pu = 0.00464 ± 0.00007, and 242 Pu/ 239 Pu = 0.0157 ± 0.0001 (k = 2). These results closely align with the certificate values for CRM 136a and CRM 137 and are within the k = 2 envelopes defined by the long-term performance of the traditional MC-ICP-MS approach (Neptune Plus). Examination of the performance of the various Pu isotope ratios as a function of total Pu content revealed accurate results (<3% relative difference, or RD) above ∼50 fg total Pu. The results presented here demonstrate the capability of the MC-ICP-MS/MS making accurate and precise low level Pu isotopic measurements. While the intent of this work was not to investigate the functionality of the collision cell, the pre-mass filter was employed. Future studies are warranted to investigate the entire capability of the MC-ICP-MS/MS collision cell and pre-cell mass filter optimization for performing low level Pu isotope measurements, even in mixed matrix samples.

CRM↗

Direct analysis of cotton swipes for uranium and plutonium isotopic determination by microextraction-ICP-MS

The determination of uranium and plutonium isotopic abundance on environmental samples collected by International Atomic Energy Agency (IAEA) inspectors is vital for the detection of undeclared nuclear activities and material under the international nuclear safeguards regime. Current analytical protocols require time-consuming sample preparation steps prior to subsequent measurement by inorganic mass spectrometry (MS). Recent efforts from this laboratory have focused on developing sample preparation methods for faster analysis, potentially allowing higher sample throughput[1]. Alternative methods including microextraction sampling in conjunction with inductively coupled plasma-mass spectrometry (ICP-MS) have been recently explored. This methodology, microextraction-ICP-MS, was developed such that uranium and plutonium could be extracted from the swipe surface and directed into the ICP-MS for an in-situ measurement, eliminating the need for swipe ashing and digestion. A commercial off-the-shelf microextraction system was customized with an automated movable XY stage that can be programmed to save sampling locations, allowing for automated rapid sampling of swipe surfaces. Additional efforts have focused on the utilization of collision cell technology to the microextraction ICP-MS method. This would eliminate the need for lengthy column chemistry procedures to purify separated uranium and plutonium fractions before analysis. Here, the extracted U/Pu analyte is measured by reacting the uranium ions with CO2 in the collision cell of an ICP-MS, shifting the uranium to UO+, which will not interfere with the plutonium isotopic determination. The developed method utilizing collision cell – ICP-MS technology has demonstrated the ability to measure plutonium isotope ratios in the presence of high uranium concentration on the transient signal from the microextraction system utilizing certified reference materials from JRC-Geel and the New Brunswick Laboratory Program Office.

Bradley, Veronica↗

IsoMatchMS : Open-Source Software for Automated Annotation and Visualization of High Resolution MALDI-MS Spectra

Due to its speed, accuracy, and adaptability to various sample types, matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) has become a popular method to identify molecular isotope profiles from biological samples. Often MALDI-MS data do not include tandem MS fragmentation data, and thus the identification of compounds in samples requires external databases so that the accurate mass of detected signals can be matched to known molecular compounds. Most relevant MALDI-MS software tools developed to confirm compound identifications are focused on small molecules (e.g., metabolites, lipids) and cannot be easily adapted to protein data due to their more complex isotopic distributions. Here, we present an R package called IsoMatchMS for the automated annotation of MALDI-MS data for multiple datatypes: intact proteins, peptides, and glycans. This tool accepts already derived molecular formulas or, for proteomics applications, can derive molecular formulas from a list of input peptides or proteins including proteins with post-translational modifications. In conclusion, visualization of all matched isotopic profiles is provided in a highly accessible HTML format called a trelliscope display, which allows users to filter and sort by several parameters such as match scores and the number of peaks matched. IsoMatchMS simplifies the annotation and visualization of MALDI-MS data for downstream analyses.

47 OTHER INSTRUMENTATION↗

Assessment of Impurities in Neptunium Metal Using Double-Focusing SF-ICP-MS

In the transmutation process, minor actinides such as neptunium, americium and curium obtained from spent nuclear fuel are incorporated into new fuel that can be placed into a fast reactor, where these elements fission into products with shorter half-lives which reduces the health and safety hazards. In order to better understand the all the involved processes, fundamental physical properties of actinides should be investigated, and for that reason, high-purity materials need to be produced. One of the main challenges in characterizing these materials is the lack of pure metal available for study, and lack of analytical methods to determine the purity. Trans-uranic elements are challenging to study because of the need to be handled in specialized facilities, safeguards concerns and they are not easily purchased and/or produced. High-purity Np metal is being produced at the Materials and Fuels Complex (MFC) of Idaho National Laboratory (INL), in a process of direct oxide reduction developed by Squires and Lessing, with a target purity of 99.999%. The goal of this research is to develop methods to determine the impurities in the Np metal, with detection limits low enough to achieve this purity level. In this work, we have used several ICP-MS and ICP OES techniques, but the focus was the method development using a recently acquired Double-Focusing Sector Field Inductively Coupled Plasma Mass Spectrometer (SF-ICP-MS). To produce the Np metal, approximately 20 g of the neptunium oxide powder was calcined at 800 oC for 6 h in a magnesium oxide crucible, which is placed inside a stainless steel crucible, that goes into the Hot Uniaxial Press (HUP) furnace insert. After the calcining step, the Np oxide was mixed with approximately 9 g of calcium metal and 100 g of ultra-dry calcium chloride. The HUP furnace was heated in a ramp rate of 50 oC min -1 up to 1000 oC. When the reaction mixture reached 850 oC, a tantalum stirrer was activated at 100 rpm. After the tantalum stirrer was removed and the mixture cooled overnight, the MgO crucible was opened with a hammer and chisel to retrieve the Np metal button at the bottom of the reaction mixture. Prior to the dissolution process, the surface contaminants of the sample were removed. The Np button was washed in 10 mL of ultra-pure water for 1 min, with a faint reaction observed on the surface, indicating the presence of Ca metal. The water-washed sample was placed in a tube with 2 M HCl for only 3 s, as a vigorous reaction in the button surface was observed. The leachates were saved for further analysis. The sample was then rinsed with ultra-pure water and air-dried prior to dissolution. The cleaned sample was placed in a PTFE beaker and 25 mL of 6 M HCl and 150 µL of 24 M HF were added. After 10 minutes of reaction, the beaker was placed on a hot plate for 1 h and 30 min, followed by the addition of 1 mL of 16 M HNO3 and allowed to react for a further 1 h and 20 min. The sample was removed from heat and 10 mL of HNO3 16 M was added to react with the HCl. The beaker was covered and left for overnight reaction, producing a solution with approximately 20 mL of final volume. A Quadrupole Inductively Coupled Plasma Mass Spectrometer (Q-ICP-MS, Perkin Elmer ELAN DRC II Q-ICP-MS) was used to obtain qualitative mass spectra for the dissolution blank, each of the leachates and the dissolved sample. In the water leachate spectrum mainly Ca and Mg were observed, while the acid wash had a similar peak pattern to the one observed for the Np metal sample, indicating that the process not only removed surface contamination, but also reacted with the sample itself. In the Np material spectrum, Ta and actinides were identified as candidates for major contaminants, as the most intense peaks corresponded to the mass-to-charge ratios of these elements. Minor contaminants included Al, Au, Ca, Cr, Fe, I, Na, Nb, Pb, Sn, Ti, Tl, V, Y. The presence of impurities in the material could have originated from several sources, such as the materials used for the casting process, the use of impure NpO2 or contamination of reagents and materials used for the analysis. Some of the isotopes listed as potential contaminants are susceptible to spectral interferences, so Double-Focusing SF-ICP-MS (Nu Instruments Attom ES HR-ICP-MS) was used for the quantitative analysis. For each isotope determined, several items were evaluated: raw signal of a blank solution, sensitivity and determination coefficient of calibration curves, possibility of interferences and comparison of results obtained for at least two resolving powers (RP): 300 and 4000. The evaluation of the signal in a blank solution can indicate if a spectral interference from the plasma gas and/or the solvent was successfully resolved (commonly observed for 52Cr+/40Ar12C+, for example). It is important to highlight that a signal reduction is expected when a higher RP is used, as the ion beam transmission is decreased by the use of narrower slits

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Microextraction–TQ–ICP–MS for the Direct Analysis of U and Pu from Cotton Swipes

Here, the microextraction sampling technique was integrated with triple quadrupole–inductively coupled plasma–mass spectrometry (TQ–ICP–MS) to directly sample and measure the isotopic compositions of uranium (U) and plutonium (Pu) from cotton swipes. Once extracted, the U/Pu were directed into the TQ–ICP–MS instrument for isotopic determination. Carbon dioxide (CO 2 ) and helium (He) gases were delivered to a collision reaction cell within the ICP–MS system for ion separation. The CO 2 reacts with the U + forming UO + which is ultimately separated from the Pu + ions of interest in the third quadrupole. This study demonstrates direct liquid extraction of U/Pu from a solid surface and subsequent measurement by TQ–ICP–MS in <60 s. Flow rates were optimized (0.3 mL min –1 CO 2 and 5 mL min –1 He) in the reaction cell of the ICP–MS system to maximize the Pu signal while minimizing U interferences (i.e., 238 U + tail and 238 UH + ) at m/z 239. Low levels of Pu (~2 pg) were deposited on a cotton swipe along with U at concentrations ranging from 20 to 200 ng. The 240 Pu/ 239 Pu ratio was measured with <7% relative difference from the certified value at all U concentrations. Major and minor U isotope ratios were also measured with <4% relative difference. This highlights that the microextraction–TQ–ICP–MS method can extract a mixed U/Pu sample directly from a cotton swipe and measure both isotopic systems without chemical separation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Characterization of actinide abundances and isotopic compositions by HR-ICP-MS. Part 2: Results from actinide doping studies

Previously, we presented actinide isotopic and elemental data from fallout melt glass that was measured using high-resolution inductively coupled plasma mass spectrometry (HR-ICP-MS). Direct comparison between these measurements and ‘gold standard’ data obtained by multi-collector ICP-MS showed broad overlap, indicating that HR-ICP-MS is a potentially valuable technique for producing actinide elemental and isotopic data on a relatively rapid timescale. To test the usefulness of this technique further, we doped varying amounts of uranium certified reference materials (CRMs) into a rhyolitic rock standard to establish the effects of uranium concentration and isotopic composition on the accuracy of uranium isotopic analyses by HR-ICP-MS. This also enabled us to quantify peak tailing effects from 238 U on the measurement of 239 Pu and 237 Np, which in turn allows us to constrain correction factors based on measured 237 Np/ 238 U and 239 Pu/ 238 U ratios. A second doping study involved the addition of a mixed actinide standard into three samples with different matrix compositions (termed soil, city, and seawater) to assess whether sample chemistry affects the accuracy and precision of these analyses. Results suggest that this is not the case. Systematic offsets were not observed in elemental or isotopic data derived from the three matrix samples. Results indicate that useful actinide isotopic data can be obtained from whole rock solutions by HR-ICP-MS. Our findings also have implications for solid sampling techniques such as laser ablation ICP-MS, which do not require sample dissolution.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Improved Characterization of Soil Organic Matter by Integrating FT-ICR MS, Liquid Chromatography Tandem Mass Spectrometry, and Molecular Networking: A Case Study of Root Litter Decay under Drought Conditions

Understanding of how soil organic matter (SOM) chemistry is altered in a changing climate has advanced considerably; however, most SOM components remain unidentified, impeding the ability to characterize a major fraction of organic matter and predict what types of molecules, and from which sources, will persist in soil. Here we present a novel approach to better characterize SOM extracts by integrating information from three types of analyses, and we deploy this method to characterize decaying root-detritus soil microcosms subjected to either drought or normal conditions. To observe broad differences in composition, we employed direct infusion Fourier-transform ion cyclotron resonance mass spectrometry (DI-FT-ICR MS). We complemented this with liquid chromatography tandem mass spectrometry (LC-MS/MS) to identify components by library matching. Since libraries contain only a small fraction of SOM components, we also used fragment spectral cosine similarity scores to relate unknowns and library matches through molecular networks. This integrated approach allowed us to corroborate DI-FT-ICR MS molecular formulas using library matches, which included fungal metabolites and related polyphenolic compounds. We also inferred structures of unknowns from molecular networks and improved LC-MS/MS annotation rates from ~5 to 35% by considering DI-FT-ICR MS molecular formula assignments. Under drought conditions, we found greater relative amounts of lignin-like vs condensed aromatic polyphenol formulas and lower average nominal oxidation state of carbon, suggesting reduced decomposition of SOM and/or microbes under stress. Our integrated approach provides a framework for enhanced annotation of SOM components that is more comprehensive than performing individual data analyses in parallel.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Advancing Elemental and Isotopic Analysis of Uranium Mineral Inclusions: Rapid Screening via Laser-Induced Breakdown Spectroscopy and High-Resolution Laser Ablation-ICP-MS Mapping

The work presented herein employs two laser-based analytical techniques (laser-induced breakdown spectroscopy (LIBS) and laser ablation – inductively coupled plasma – mass spectrometry (LA-ICP-MS)) to spatially determine the elemental and isotopic composition of uranium bearing minerals. Uniquely, this work leverages the high-speed applicability of LIBS to “screen” the sample(s) for their elemental constituents. After determining the location of the uranium inclusions (via LIBS), high-resolution LA-ICP-MS was employed to further characterize the inclusions. The high-resolution (sub-µm) capabilities of LA-ICP-MS were able to extract important information from the uranium minerals including discerning its chemical form (e.g., finchite from carnotite, Sr- and K-bearing uranyl vanadates, respectively) as well as their 235 U/ 238 U isotopic composition. This approach, LIBS followed by LA-ICP-MS, significantly reduces the analysis time (~95 %) in comparison to employing a LA-ICP-MS only approach. Furthermore, this work presented a novel approach to analyzing inclusions via a particle/inclusion analysis tool which is commercially available within the iolite 4 software. This tool allowed for a more accurate characterization of the isotopic distribution of the inclusions, as well as allowing for rapid sizing of the inclusions. Finally, this analytical approach could readily be applied to other sample types in which the target species (e.g., µm-sized inclusions) are embedded in complex matrices (e.g., cm-sized samples).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗