Search NASA⌕ Search

SEARCH · Search NASA

Results for “MS software”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Verification Testing: Meet User Needs Figure of Merit

Verification is the process through which Modeling and Simulation(M&S) software goes to ensure that it has been rigorously tested and debugged for its intended use. Validation confirms that said software accurately models and represents the real world system. Credibility gives an assessment of the development and testing effort that the software has gone through as well as how accurate and reliable test results are. Together, these three components form Verification, Validation, and Credibility(VV&C), the process by which all NASA modeling software is to be tested to ensure that it is ready for implementation. NASA created this process following the CAIB (Columbia Accident Investigation Board) report seeking to understand the reasons the Columbia space shuttle failed during reentry. The reports conclusion was that the accident was fully avoidable, however, among other issues, the necessary data to make an informed decision was not there and the result was complete loss of the shuttle and crew. In an effort to mitigate this problem, NASA put out their Standard for Models and Simulations, currently in version NASA-STD-7009A, in which they detailed their recommendations, requirements and rationale for the different components of VV&C. They did this with the intention that it would allow for people receiving MS software to clearly understand and have data from the past development effort. This in turn would allow the people who had not worked with the MS software before to move forward with greater confidence and efficiency in their work. This particular project looks to perform Verification on several MATLAB (Registered Trademark)(The MathWorks, Inc.) scripts that will be later implemented in a website interface. It seeks to take note and define the limits of operation, the units and significance, and the expected datatype and format of the inputs and outputs of each of the scripts. This is intended to prevent the code from attempting to make incorrect or impossible calculations. Additionally, this project will look at the coding generally and note inconsistencies, redundancies, and other aspects that may become problematic or slow down the codes run time. Certain scripts lacking in documentation also will be commented and cataloged.

validation↗

IsoMatchMS : Open-Source Software for Automated Annotation and Visualization of High Resolution MALDI-MS Spectra

Due to its speed, accuracy, and adaptability to various sample types, matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) has become a popular method to identify molecular isotope profiles from biological samples. Often MALDI-MS data do not include tandem MS fragmentation data, and thus the identification of compounds in samples requires external databases so that the accurate mass of detected signals can be matched to known molecular compounds. Most relevant MALDI-MS software tools developed to confirm compound identifications are focused on small molecules (e.g., metabolites, lipids) and cannot be easily adapted to protein data due to their more complex isotopic distributions. Here, we present an R package called IsoMatchMS for the automated annotation of MALDI-MS data for multiple datatypes: intact proteins, peptides, and glycans. This tool accepts already derived molecular formulas or, for proteomics applications, can derive molecular formulas from a list of input peptides or proteins including proteins with post-translational modifications. In conclusion, visualization of all matched isotopic profiles is provided in a highly accessible HTML format called a trelliscope display, which allows users to filter and sort by several parameters such as match scores and the number of peaks matched. IsoMatchMS simplifies the annotation and visualization of MALDI-MS data for downstream analyses.

47 OTHER INSTRUMENTATION↗

The Future of a Myriad of Accelerated Biodiscoveries Lies in AI‐Powered Mass Spectrometry and Multiomics Integration

The intersection of modern artificial intelligence (AI) and mass spectrometry (MS) is set to transform the MS‐based “omics” research fields, particularly proteomics, metabolomics, lipidomics, and glycomics, enabling advancements across a wide range of domains, from health to environment and industrial biotechnology. Beginning with an overview of key challenges inherent in MS software pipelines, this personal perspective explores how AI‐driven solutions can address them to enhance data processing, integration and interpretation. It proposes a paradigm shift in molecular identification and quantitation algorithms, leveraging AI to enable holistic interpretation of MS‐based multiomics data. While centered on MS‐based omics, this holistic AI‐driven paradigm is also critical for connecting dynamic biochemical changes to genomics and transcriptomics contexts, reinforcing the integrative value of MS in multiomics research. Ultimately, this AI‐driven approach could enhance efficiency, accuracy, and molecular breadth of coverage, deepening our systems‐level understanding of biological processes and accelerating a myriad of biodiscoveries.

47 OTHER INSTRUMENTATION↗

SpectraCodec: A Hilbert curve-based method for encoding metadata in mass spectra for machine learning applications (SpectraCodec) v1

Machine learning approaches to mass spectrometry (MS) data analysis require structured metadata for optimal performance. However, current MS file formats necessitate external metadata sources, creating integration challenges that impede analytical workflows. Here, we present a novel approach for encoding metadata directly within mzML files using one-hot encoding of ASCII characters mapped via Hilbert space-filling curves. This strategy embeds metadata in the first spectrum's m/z-intensity space, ensuring persistence with the primary data, eliminating the need for external metadata files, and maintaining compatibility with existing MS software. We demonstrate that the Hilbert curve mapping efficiently utilizes the two-dimensional spectral space while maintaining robust data recovery. This method offers a practical solution for machine learning applications in mass spectrometry by ensuring metadata and spectral data remain unified through all stages of analysis.

Bowen, Benjamin [Lawrence Berkeley National Labora↗

Modeling and Simulation Credibility Assessments of Musculoskeletal Computational Models for Simulating Astronaut Injuries Due to a Poor Spacesuit Fit

The musculoskeletal (MS) system of astronauts is subject to physiological changes, potentially leading to injuries due to the exposure to different gravitational environments experienced during spaceflight. These injuries can occur while an astronaut is performing an Extravehicular Activity (EVA) in space, on lunar or planetary surfaces or while wearing a spacesuit during terrestrial training for an EVA. The OpenSim MS modeling software can assess EVA induced MS injury mechanisms such as muscle strains, ligament injuries and joint injuries. One area of concern, since there are only a few different spacesuit sizes with limited adjustability, is the possibility of a poorly fitting spacesuit. This can cause unnatural joint motions and torques resulting in various MS injuries. A credibility assessment of the OpenSim modeling and simulation procedures is performed per NASA-STD-7009A to provide information on the credibility of the model’s use in simulating EVA related injury mechanisms. The credibility assessment evaluated various OpenSim models against the following eight credibility factors: data pedigree, input pedigree, code verification, solution verification, conceptual validation, referent validation, results uncertainty and results robustness (sensitivity). The models evaluated for EVA injuries will require additional credibility factor analysis and upgrades to the model features, such as adding ligaments to a whole-body model, to reliably predict and analyze the EVA injuries expected to occur due to a poor spacesuit fit. The degree of elevation strategy required to increase the credibility assessment scores will depend on the model complexity and the injury mechanism.

Christopher A. Gallo↗

Modeling and Simulation Credibility Assessments of Musculoskeletal Computational Models for Simulating Astronaut Injuries Due to a Poor Spacesuit Fit

The musculoskeletal (MS) system of astronauts is subject to physiological changes, potentially leading to injuries due to the exposure to different gravitational environments experienced during spaceflight. These injuries can occur while an astronaut is performing an Extravehicular Activity (EVA) in space, on lunar or planetary surfaces or while wearing a spacesuit during terrestrial training for an EVA. The OpenSim MS modeling software can assess EVA induced MS injury mechanisms such as muscle strains, ligament injuries and joint injuries. One area of concern, since there are only a few different spacesuit sizes with limited adjustability, is the possibility of a poorly fitting spacesuit. This can cause unnatural joint motions and torques resulting in various MS injuries. A credibility assessment of the OpenSim modeling and simulation procedures is performed per NASA-STD-7009A to provide information on the credibility of the model’s use in simulating EVA related injury mechanisms. The credibility assessment evaluated various OpenSim models against the following eight credibility factors: data pedigree, input pedigree, code verification, solution verification, conceptual validation, referent validation, results uncertainty and results robustness (sensitivity). The models evaluated for EVA injuries will require additional credibility factor analysis and upgrades to the model features, such as adding ligaments to a whole-body model, to reliably predict and analyze the EVA injuries expected to occur due to a poor spacesuit fit. The degree of elevation strategy required to increase the credibility assessment scores will depend on the model complexity and the injury mechanism.

Christopher A Gallo↗

SimELIT: A Novel GUI-Based Comprehensive Ion Trajectory Simulation Software for Mass Spectrometry

Ion trajectory simulation in mass spectrometry systems from injection to detection is technically challenging but very important for better understanding the ion dynamics in instrument development. Here, in this work, we present SimELIT (Simulator of Eulerian and Lagrangian Ion Trajectories), a novel ion trajectory simulation platform. SimELIT is built upon a suite of multiphysics solvers compiled into OpenFOAM (an open-source numerical solver library particularly used for computational mechanics), with a simple web-based graphical user interface (GUI) allowing users to define the details of OpenFOAM cases and run simulations. SimELIT is a modular program and can provide extensions of physics (e.g., gas flows, electrodynamic fields) and thus enable ion trajectory simulations from the ion source to detector. The current version (SimELIT) provides two numerical solvers for ion trajectory simulations–(1) a Lagrangian particle tracker in vacuum and (2) a Eulerian ion density solver in background gas in the presence of electric fields. Here, we describe the architecture of SimELIT, including its use of Docker and the React Framework, and demonstrate the computation of ion trajectories of multiple m/z values in a static/linear voltage drop in vacuum (across a 1 m long flight tube). Further, the drift motion of ions under 1 Torr pressure conditions in a static background (N 2 ) gas through a 20 V/cm static electric field is shown. The results produced from SimELIT were compared with SIMION and theoretical estimates. In addition, we report the computation of ion trajectories in electrodynamic fields within a planar FAIMS device operating at atmospheric pressure.

97 MATHEMATICS AND COMPUTING↗

Concentration and Velocity Gradients in Fluidized Beds

In this work we focus on the height dependence of particle concentration, average velocity components, fluctuations in these velocities and, with the flow turned off, the sedimentation velocity. The latter quantities are measured using Particle Imaging Velocimetry (PIV). The PIV technique uses a 1-megapixel camera to capture two time-displaced images of particles in the bed. The depth of field of the imaging system is approximately 0.5 cm. The camera images a region with characteristic length of 2.6 cm for the small particles and 4.7 cm. for the large particles. The local direction of particle flow is determined by calculating the correlation function for sub-regions of 32 x 32 pixels. The velocity vector map is created from this correlation function using the time between images (we use 15 to 30 ms). The software is sensitive variations of 1/64th of a pixel. We produce velocity maps at various heights, each consisting of 3844 velocities. We break this map into three vertical zones for increased height information. The concentration profile is measured using an expanded (1 cm diameter) linearly polarized HeNe Laser incident on the fluidized bed. A COHU camera (gamma=1, AGC off) with a lens and a polarizer images the transmitted linearly polarized light to minimize the effects of multiply scattered light. The intensity profile (640 X 480 pixels) is well described by a Gaussian fit and the height of the Gaussian is used to characterize the concentration. This value is compared to the heights found for known concentrations. The sedimentation velocity is estimated using by imaging a region near the bottom of the bed and using PIV to measure the velocity as a function of time. With a nearly uniform concentration profile, the time can be converted to height information. The stable fluidized beds are made from large pseudo-monodisperse particles (silica spheres with radii (250-300) microns and (425-500) microns) dispersed in a glycerin/water mix. The Peclet number is sufficiently large that Brownian motion of the particles can be ignored and the Reynolds number sufficiently small that particle inertia is negligible. A packed particle bed is used to randomize and disperse the flowing fluid introduced by a peristaltic pump. The bed itself is a rectangular glass cell 8 cm wide (x), 0.8 cm deep and a height of 30.5 cm (z). The depth of field of the camera is approximately 0.5 cm so depth information is averaged. Over flow fluid is returned to the reservoir making a closed loop system. In these experiments the particles form a sediment approximately 5.7 cm high with the pump off and expand to 22 cm with the pump on. For the smaller particles the pump velocity is .5 millimeters per second and 1.1 millimeters per second for the large particles. At this concentration the bed has a very well defined top where particle concentration rapidly drops to zero.

McClymer, James P.↗

R “SHINY” GUI DEVELOPMENT FOR URANIUM ISOTOPIC ANALYSIS WITH MATRIX-ASSISTED IONIZATION MASS SPECTROMETRY

The international nuclear safeguards community continues to seek rapid, accurate, and precise characterization capabilities for the in-field measurement of uranium isotopic compositions in nuclear facilities. Mass spectrometry (MS) is considered the “gold standard” for analysis of relatively long-lived actinides such as uranium (U) and plutonium; however, conventional MS analysis often requires time consuming sample preparation and complex analytical methodologies that are difficult to perform in-field or in-facility. Matrix assisted ionization (MAI) is a novel ambient ionization MS technique (i.e., MAI-MS) that potentially addresses these challenges due to the relative simplicity of the ionization phenomenon and ruggedness of ambient MS instrumentation. Savannah River National Laboratory (SRNL, USA) has demonstrated this technique for nanogram-level 235U/238U isotope ratio measurements within seconds, with percent-level analytical uncertainties capable of discriminating depleted, natural, and low-enriched uranium. Current experimental work on developing MAI methods for uranium isotopic analysis has been enabled by parallel development of a comprehensive MAI-MS data analysis suite at SRNL. Development of this bespoke data analysis software was necessary because commercially available ambient MS software is poorly suited for uranium isotope ratio measurement. The effort leverages the power of R, a popular open-source programming language, and Shiny, an R package providing tools for graphical user interface (GUI) and web interface coding. This software allows researchers without any programming experience to harness and utilize R’s considerable data analysis/visualization power.

LaBone, Elizabeth D.↗

Algorithms and file structures to enhance software workflows for ion mobility mass spectrometry (IM-MS)

Support customizations of algorithms and raw data file structures to enhance software workflows for liquid chromatography (LC), mass spectrometry (MS) and ion mobility mass spectrometry (IM-MS)-based metabolite characterization. Evaluate and improve the integration of ion mobility to existing MS analysis methods of the Mass Profiler Professional workflow (Mass Profiler, ID Browser and Mass Profiler Professional).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A deep learning-guided automated workflow in LipidOz for detailed characterization of fungal fatty acid unsaturation by ozonolysis

Understanding fungal lipid biology and metabolism is critical for antifungal target discovery as lipids play central roles in cellular processes. Nuances in lipid structural differences can significantly impact their functions, making it necessary to characterize lipids in detail to enable and understanding of their roles in these complex systems. In particular, lipid double bond (DB) locations are an important component of lipid structure that can only be determined using a few specialized analytical techniques. Ozone-induced dissociation mass spectrometry (OzID-MS) is one such technique that uses ozone to break lipid DBs, producing pairs of characteristic fragments that allow the determination of DB positions. In this work we apply OzID-MS and LipidOz software to analyze the complex lipids of Saccharomyces cerevisiae yeast strains transfected with different fatty acid desaturases from Histoplasma capsulatum to determine the specific unsaturated lipids produce. The automated data analysis in LipidOz made the determination of DB positions from this large dataset more practical, but manual verification for all targets was still time-consuming. The DL model reduces manual involvement in data analysis, but since it was trained using mammalian lipid extracts, the prediction accuracy on yeast-derived data was reduced. We addressed both shortcomings by retraining the DL model to act as a pre-filter to prioritize targets for automated analysis, providing confident manually verified results but requiring less computational time and manual effort. Our workflow resulted in the determination of novel DB positions and enzymatic specificity.

mass spectrometry, deep learning, Lipidomics, doub↗

GLBRC Soil Yearlong Incubation 13C-SIP-Lipidomics

Data package for Lipids represent a dynamic, yet stable pool of microbially-derived soil carbon This data is published under a CC0 license. The authors encourage data reuse and request attribution by referencing the below citations for the data packages and associated manuscript. Please cite as: Rempfert KR, Bell SL, Kasanke CP, Kyle JE, Hofmockel KS. 2025. GLBRC Soil Yearlong Incubation 13C-SIP-Lipidomics. [Data Set] PNNL DataHub. doi: Rempfert KR, Bell SL, Kasanke CP, Kyle JE, Hofmockel KS. 2025. MSV000097435: GLBRC soil yearlong incubation 13C-SIP-Lipidomics [Data Set] MassIVE. doi:10.25345/C57659T3K Rempfert KR, Bell SL, Kasanke CP, Kyle JE, Hofmockel KS. 2025. Lipids represent a dynamic, yet stable pool of microbially-derived soil carbon. In Prep This data package consists of compound-specific 13C SIP-lipidomics data from a yearlong tracer incubation experiment designed to investigate microbial lipid persistence in switchgrass bioenergy crop soils. In order to explore how lipid structure may modulate the persistence of C in soil lipids, we leveraged soils from two sites (Michigan - sandy texture, Wisconsin - silty texture) operated by the U.S. Department of Energy-funded Great Lakes Bioenergy Research Center (GLBRC). These sites had comparable climates, identical management practices, but contrasting soil textures, allowing us to assess the variability of lipid accrual or degradation in soils as well as provide insight regarding the degree to which edaphic properties may regulate the retention of soil lipids. Untargeted lipidomics analyses were performed to identify 13C-labeled lipids in the soil microbiome after long-term incubation. Soils were supplemented with 100 micrograms glucose per gram dry soil (99 atom % 13C or natural abundance for paired control) and incubated; samples were collected two months and one year after glucose addition. Lipid extracts (MPLEx) were analyzed by LC-MS/MS and identified using LIQUID. Calculation of isotopic enrichment of lipids was performed by targeted approach using TarMet to quantify lipid isotopologues and IsoCorrectoR to correct for natural abundance isotopes. Contents: Data package contents reported here are the first version and contain downstream analysis files for the raw LC-MS mass spectrometry files (.mzXML) deposited at the MassIVE database repository under accession MSV000097435 (80 experimental runs; 5.85 GB) | MassIVE DOI: 10.25345/C57659T3K. Support files include the additional data download 'Read Me' file containing data descriptor information. Reported data download contents are structured for compliance with project data sharing guidelines, community standards initiatives, and sponsor stakeholder policies supporting FAIR data principles. Data processing software, analysis tools, and data workflows are listed below corresponding to the host repository long-term location. Available Data Downloads (0.3 GB): "GLBRC soil yearlong incubation 13C-SIP-Lipidomics_readme.txt" - 'Read Me' data package content file (txt) "GLBRC_DataPackage_analysis files" - Data processing files (Rmd) and saved intermediate data processing outputs (rds, csv, xlsx) "GLBRC_13C_lipidomics_dataset.xlsx" - processed data in tabular format (xlsx) Linked Software: LIQUID LC-MS Analysis Software | 10.5281/zenodo.6459462 Lipid Mini-On Software Tools | 10.5281/zenodo.1492803 pmartR Omics Statistical Software | 10.5281/zenodo.6108667 xcms (v4.3.3) TarMet (v1.1.1) IsoCorrectoR (1.24.0) Funding Acknowledgments: This research was supported by an Early Career Research Program award funded by the U.S. Department of Energy, Office of Science, Office of Biological and Environmental Research (OBER) Genomic Science program under FWP 68292, FWP 07880 and EMSL Exploratory Research Project 51095. A portion of this work was performed in the William R. Wiley Environmental Molecular Sciences Laboratory, a national scientific user facility sponsored by OBER and located at Pacific Northwest National Laboratory (PNNL). PNNL is a multi-program national laboratory operated by Battelle for the DOE under Contract DE-AC05-76RLO1830.

Rempfert, Kaitlin R [Pacific Northwest National La↗

SAO mission support software and data standards, version 1.0

This document defines the software developed by the SAO AXAF Mission Support (MS) Program and defines standards for the software development process and control of data products generated by the software. The SAO MS is tasked to develop and use software to perform a variety of functions in support of the AXAF mission. Software is developed by software engineers and scientists, and commercial off-the-shelf (COTS) software is used either directly or customized through the use of scripts to implement analysis procedures. Software controls real-time laboratory instruments, performs data archiving, displays data, and generates model predictions. Much software is used in the analysis of data to generate data products that are required by the AXAF project, for example, on-orbit mirror performance predictions or detailed characterization of the mirror reflection performance with energy.

Hsieh, P.↗

Software engineering and data management for automated payload experiment tool

The Microgravity Projects Office identified a need to develop a software package that will lead experiment developers through the development planning process, obtain necessary information, establish an electronic data exchange avenue, and allow easier manipulation/reformatting of the collected information. An MS-DOS compatible software package called the Automated Payload Experiment Tool (APET) has been developed and delivered. The objective of this task is to expand on the results of the APET work previously performed by UAH and provide versions of the software in a Macintosh and Windows compatible format.

Maddux, Gary A.↗

Software engineering and data management for automated payload experiment tool

The Microgravity Projects Office identified a need to develop a software package that will lead experiment developers through the development planning process, obtain necessary information, establish an electronic data exchange avenue, and allow easier manipulation/reformatting of the collected information. An MS-DOS compatible software package called the Automated Payload Experiment Tool (APET) has been developed and delivered. The objective of this task is to expand on the results of the APET work previously performed by University of Alabama in Huntsville (UAH) and provide versions of the software in a Macintosh and Windows compatible format. Appendix 1 science requirements document (SRD) Users Manual is attached.

Maddux, Gary A.↗

MetaboDirect: an analytical pipeline for the processing of FT-ICR MS-based metabolomic data

Background: Microbiomes are now recognized as the main drivers of ecosystem function ranging from the oceans and soils to humans and bioreactors. However, a grand challenge in microbiome science is to characterize and quantify the chemical currencies of organic matter (i.e., metabolites) that microbes respond to and alter. Critical to this has been the development of Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR MS), which has drastically increased molecular characterization of complex organic matter samples, but challenges users with hundreds of millions of data points where readily available, user-friendly, and customizable software tools are lacking. Results: Here, we build on years of analytical experience with diverse sample types to develop MetaboDirect, an open-source, command-line-based pipeline for the analysis (e.g., chemodiversity analysis, multivariate statistics), visualization (e.g., Van Krevelen diagrams, elemental and molecular class composition plots), and presentation of direct injection high-resolution FT-ICR MS data sets after molecular formula assignment has been performed. When compared to other available FT-ICR MS software, MetaboDirect is superior in that it requires a single line of code to launch a fully automated framework for the generation and visualization of a wide range of plots, with minimal coding experience required. Among the tools evaluated, MetaboDirect is also uniquely able to automatically generate biochemical transformation networks (ab initio) based on mass differences (mass difference network-based approach) that provide an experimental assessment of metabolite connections within a given sample or a complex metabolic system, thereby providing important information about the nature of the samples and the set of microbial reactions or pathways that gave rise to them. Finally, for more experienced users, MetaboDirect allows users to customize plots, outputs, and analyses. Conclusion: Application of MetaboDirect to FT-ICR MS-based metabolomic data sets from a marine phage-bacterial infection experiment and a Sphagnum leachate microbiome incubation experiment showcase the exploration capabilities of the pipeline that will enable the research community to evaluate and interpret their data in greater depth and in less time. It will further advance our knowledge of how microbial communities influence and are influenced by the chemical makeup of the surrounding system. The source code and User’s guide of MetaboDirect are freely available through (https://github.com/Coayala/MetaboDirect) and (https://metabodirect.readthedocs.io/en/latest/), respectively.

54 ENVIRONMENTAL SCIENCES↗

High-throughput mass spectrometry analysis using immediate drop-on-demand technology coupled with an open port sampling interface

Rationale: The sampling throughput of immediate drop-on-demand technology (I.DOT) coupled with an open port sampling interface (OPSI) is limited by software communication. To enable much-needed high-throughput mass spectrometry (MS) analysis capabilities, a novel software was developed that allows for flexible sample selection from a 96-well plate and for maximized analysis throughput using I.DOT/OPSI-MS coupling. Methods: Wells of a 96-well I.DOT plate were filled with propranolol solution and were used to test maximum sampling throughput strategies to minimize analysis time. Demonstration of chemical reaction monitoring was done using acid-catalyzed ring closure of 2,3-diaminonaphthalene (DAN) with nitrite to form 2,3-naphthotriazole (NAT). Analytes were detected in positive electrospray ionization mode using selected reaction monitoring. Results: A maximum throughput of 1.54 s/sample (7.41 min/96-well plate with three technical replicates) was achieved, and it was limited by the peak width of the MS signal resulting in an occasional slight overlap between the peaks. Further, relative standard deviation was 10 ± 1% with all tested sampling strategies. Chemical reaction monitoring of DAN to NAT using nitrite was successfully accomplished with 2 s/sample throughout showing almost complete transformation in 10 min with no signal overlap. Conclusions: This work illustrates the development of a noncontact, automated I.DOT/OPSI-MS system with improved throughput achieved through an optimized software interface. Its achievable analysis time and precision make it a viable approach for drug discovery and in situ reaction monitoring studies.

47 OTHER INSTRUMENTATION↗

The Software Element of the NASA Portable Electronic Device Radiated Emissions Investigation

NASA Langley Research Center's (LaRC) High Intensity Radiated Fields Laboratory (HIRF Lab) recently conducted a series of electromagnetic radiated emissions tests under a cooperative agreement with Delta Airlines and an interagency agreement with the FAA. The frequency spectrum environment at a commercial airport was measured on location. The environment survey provides a comprehensive picture of the complex nature of the electromagnetic environment present in those areas outside the aircraft. In addition, radiated emissions tests were conducted on portable electronic devices (PEDs) that may be brought onboard aircraft. These tests were performed in both semi-anechoic and reverberation chambers located in the HIRF Lab. The PEDs included cell phones, laptop computers, electronic toys, and family radio systems. The data generated during the tests are intended to support the research on the effect of radiated emissions from wireless devices on aircraft systems. Both tests systems relied on customized control and data reduction software to provide test and instrument control, data acquisition, a user interface, real time data reduction, and data analysis. The software executed on PC's running MS Windows 98 and 2000, and used Agilent Pro Visual Engineering Environment (VEE) development software, Common Object Model (COM) technology, and MS Excel.

Koppen, Sandra V.↗