Search NASA⌕ Search

SEARCH · Search NASA

Results for “MULTICHANNEL RECEIVER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Method of measuring sea surface water temperature with a satellite including wideband passive synthetic-aperture multichannel receiver

A wideband passive synthetic-aperture multichannel receiver with an antenna is mounted on a satellite which travels in an orbit above the Earth passing over large bodies of water, e.g., the Atlantic Ocean. The antenna is scanned to receive signals over a wide frequency band from each incremental surface area (pixel) of the water which are related to the pixel's sea temperature. The received signals are fed to several channels which are tuned to separate selected frequencies. Their outputs are fed to a processor with a memory for storage. As the antenna points to pixels within a calibration area around a buoy of known coordinates, signals are likewise received and stored. Exactly measured sea temperature is received from the buoy. After passing over several calibration areas, a forward stepwise regression analysis is performed to produce an expression which selects the significant from the insignificant channels and assigns weights (coefficients) to them. The expression is used to determine the sea temperature at each pixel based on the signals received therefrom. Wind temperature, pressure, and wind speed at each pixel can also be calculated.

Stacey, J. M.↗

Coherent optical array receiver experiment : design, implementation and BER performance of a multichannel coherent optical receiver for PPM signals under atmospheric turbulence

The performance of a coherent free-space optical communication system operating in the presence of turbulence is investigated. Maximum Likelihood Detection techniques are employed to optimally detect Pulse Position Modulated signals with a focal-plane detector array, and reconstruct the turbulence-degraded signals. The experimental demonstration of this project and results may be divided in three parts; two of which have already been explained in previous publications (1,2). This latest paper shows the final experimental results, including investigation of performance of the Coherent Optical Receiver Experiment (CORE) performed at the laboratory facilities at JPL. Bit Error Rate (BER) is presented for single and multichannel optical receivers, where quasi-shot noise limited performance is achieved, under simulated turbulence conditions using non-coherent post-detection processing techniques.

Hassibi, Babak↗

Calibration of the Nimbus-7 SMMR. 2: Polarization mixing corrections

Averaged radiance data obtained over the oceans from the Nimbus-7 Scanning Multichannel Microwave Radiometer (SMMR) are used to produce an empirical correction algorithm for the polarization mixing which is inherent to the SMMR because of its fixed multichannel receiving horn and its scanning antenna dish. The algorithm, developed without the use of an ocean/atmosphere radiance model, also properly accounts for off center and scan independent polarization mixing, which were discovered after launch as a result of analyzing the aforementioned data. The radiance averaging consisted of collecting data for each beam position of each of the ten radiance channels of SMMR (nominal horizontal and vertical polarizations of the five SMMR wavelengths, 0.81, 1.4, 1.7, 2.8, and 4.6 cm) for about 300 orbits, subdividing the global ocean radiance data into 10 deg latitude bands and ascending (daytime) and descending (nighttime) orbits. This served to smooth out atmospheric and ocean surface variations in order to perform the polarization mixing analysis.

Gloersen, P.↗

Propagating shocks in the corona

High resolution observations performed with the Decimeter spectrograph and the multichannel receiver at Nancay were analyzed in the range of 25-75 MHz. Sixty Type II bursts were selected. In this frequency range, type II events are generally associated with other radio emissions (such as storms of type III-U-I bursts); they are preceeded or followed by groups of U-bursts. One third of type II events show a nonuniform frequency drift, usually a steep decrease followed by an abrupt increase. This phenomenon can be explained by the propagation of an extended disturbance through the ambient corona when the density gradient is enhanced. An empirical coronal model is proposed to interpret these observations. The observations at fixed frequency of Type II bursts including fundamental and harmonic components are analyzed. It is shown that the spectrum of the intensity fluctuations differs with the fundamental and the harmonic components. The origin of these differences is discussed.

Leblanc, Yolanda↗

The Polar Plasma Wave Instrument

The Plasma Wave Instrument on the Polar spacecraft is designed to provide measurements of plasma waves in the Earth's polar regions over the frequency range from 0.1 Hz to 800 kHz. Three orthogonal electric dipole antennas are used to detect electric fields, two in the spin plane and one aligned along the spacecraft spin axis. A magnetic loop antenna and a triaxial magnetic search coil antenna are used to detect magnetic fields. Signals from these antennas are processed by five receiver systems: a wideband receiver, a high-frequency waveform receiver, a low-frequency waveform receiver, two multichannel analyzers; and a pair of sweep frequency receivers. Compared to previous plasma wave instruments, the Polar plasma wave instrument has several new capabilities. These include (1) an expanded frequency range to improve coverage of both low- and high-frequency wave phenomena, (2) the ability to simultaneously capture signals from six orthogonal electric and magnetic field sensors, and (3) a digital wideband receiver with up to 8-bit resolution and sample rates as high as 249k samples s(exp -1).

Gurnett, D. A.↗

Gated truncated readout system

A gated truncated readout system for position sensitive or imaging detectors that improves resolution over traditional readout systems. The readout system includes two or more amplifiers that receive a multichannel output analog data from the detector. Analog gates control circuitry, included in the readout circuit, receives the signals from the amplifiers, determines a fractional value of the sum-integral of the signals, and enables analog gates operation around an area of interest, disabling all other channels where noise dominates the signal value and thereby improving interpolation accuracy of the signals centroid position and the detector resolution. Filtered signals are transmitted to a centroid interpolation signal processing device for computation of the centroid position. As a result disabling all channels where noise dominates the signal value, the gated truncated readout system provides better accuracy improved detector resolution.

Popov, Vladimir↗

Use of implantable telemetry systems for study of cardiovascular phenomena.

Preliminary observations of cardiovascular function have been made in four chimpanzees using multichannel implantable units. Measurements of right- and left-sided pressures were periodically made in these animals over a four-month period, including continuous observations for selected 24-hour periods. Pressures recorded with animals in an awake, unanesthetized, unrestrained state were much lower than pressures reported for restrained animals in similar situations. Diurnal variations of pressure tended to occur, but were not as clear-cut as those reported to occur for humans. The ability to implant a transmitter chronically and receive useful multichannel information in the chimpanzee encourages the future use of such implant devices as part of the control system for an artificial heart or directly for use in man.

Sandler, H.↗

A ground-based technique for millimeter wave spectroscopic observations of stratospheric trace constituents

Recent concern over possible long term stratospheric changes caused by the introduction of man-made compounds has increased the need for instrumentation that can accurately measure stratospheric minor constituents. The technique of radio spectroscopy at millimeter wavelengths was first used to observe rotational transitions of stratospheric ozone nearly two decades ago, but has not been highly developed until recently. A ground-based observing technique is reported which employs a millimeter-wave superheterodyne receiver and multichannel filter spectrometer for measurements of stratospheric constituents that have peak volume mixing ratios that are less than 10 to the -9th, more than 3 orders of magnitude less than that for ozone. The technique is used for an extensive program of observations of stratospheric chlorine monoxide and also for observations of other stratospheric trace gases such as (O-16)3, vibrationally excited (O-16)3, (O-18)2(O-16), N2O, HO2, and HCN. In the present paper, analysis of the observing technique is given, including the method of calibration and analysis of sources of error. The technique is found to be a reliable means of observing and monitoring important stratospheric trace constituents.

Parrish, A.↗

Contemporary Toxicity Profile of Breast Brachytherapy Versus External Beam Radiation After Lumpectomy for Breast Cancer

Purpose: We compared toxicities after brachytherapy versus external beam radiation therapy (EBRT) in contemporary breast cancer patients. Methods and Materials: Using MarketScan healthcare claims, we identified 64,112 women treated from 2003 to 2012 with lumpectomy followed by radiation (brachytherapy vs EBRT). Brachytherapy was further classified by multichannel versus single-channel applicator approach. We identified the risks and predictors of 1-year infectious and noninfectious postoperative adverse events using logistic regression and temporal trends using Cochran-Armitage tests. We estimated the 5-year Kaplan-Meier cumulative incidence of radiation-associated adverse events. Results: A total of 4522 (7.1%) patients received brachytherapy (50.2% multichannel vs 48.7% single-channel applicator). The overall risk of infectious adverse events was higher after brachytherapy than after EBRT (odds ratio [OR] = 1.21; 95% confidence interval [CI] 1.09-1.34, P<.001). However, over time, the frequency of infectious adverse events after brachytherapy decreased, from 17.3% in 2003 to 11.6% in 2012, and was stable after EBRT at 9.7%. Beyond 2007, there were no longer excess infections with brachytherapy (P=.97). The overall risk of noninfectious adverse events was higher after brachytherapy than after EBRT (OR=2.27; 95% CI 2.09-2.47, P<.0001). Over time, the frequency of noninfectious adverse events detected increased: after multichannel brachytherapy, from 9.1% in 2004 to 18.9% in 2012 (Ptrend = .64); single-channel brachytherapy, from 12.8% to 29.8% (Ptrend<.001); and EBRT, from 6.1% to 10.3% (Ptrend<.0001). The risk was significantly higher with single-channel than with multichannel brachytherapy (hazard ratio = 1.32; 95% CI 1.03-1.69, P=.03). Of noninfectious adverse events, 70.9% were seroma. Seroma significantly increased breast pain risk (P<.0001). Patients with underlying diabetes, cardiovascular disease, and treatment with chemotherapy had increased infectious and noninfectious adverse events. The 5-year incidences of fat necrosis, breast pain, and rib fracture were slightly higher after brachytherapy than after EBRT (13.7% vs 8.1%, 19.4% vs 16.0%, and 1.6% vs 1.3%, respectively), but the risks were not significantly different for multichannel versus single-channel applicators. Conclusion: Toxicities after breast brachytherapy were distinct from those after EBRT. Temporal toxicity trends may reflect changing technology and evolving practitioner experience with brachytherapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-T-10: A Clinical Implementation and the Dosimetric Evidence in High Dose Rate Vaginal Multichannel Applicator Brachytherapy

Purpose: The multichannel cylindrical applicator has a distinctive modification of the traditional single channel cylindrical applicator. The novel multichannel applicator has additional peripheral channels that provide more flexibility both in treatment planning process and outcomes. To protect by reducing doses to adjacent organ at risk (OAR) while maintaining target coverage with inverse plan optimization are the goals for such novel Brachytherapy device. Through a series of comparison and analysis of reults in more than forty patients who received HDR Brachytherapy using multichannel vaginal applicator, this procedure has been implemented in our institution. Methods: Multichannel planning was CT image based. The CTV of 5mm vaginal cuff rind with prescribed length was well reconstructed as well as bladder and rectum. At least D95 of CTV coverage is 95% of prescribed dose. Multichannel inverse plan optimization algorithm not only shapes target dose cloud but set dose avoids to OAR’s exclusively. The doses of D2cc, D5cc and D5; volume of V2Gy in OAR’s were selected to compare with single channel results when sole central channel is only possibility. Results: Study demonstrates plan superiorly in OAR’s doe reduction in multi-channel plan. The D2cc of the rectum and bladder were showing a little lower for multichannel vs. single channel. The V2Gy of the rectum was 93.72% vs. 83.79% (p=0.007) for single channel vs. multichannel respectively. Absolute reduced mean dose of D5 by multichannel was 17 cGy (s.d.=6.4) and 44 cGy (s.d.=15.2) in bladder and rectum respectively. Conclusion: The optimization solution in multichannel was to maintain D95 CTV coverage while reducing the dose to OAR’s. Dosimetric advantage in sparing critical organs by using a multichannel applicator in HDR Brachytherapy treatment of the vaginal cuff is so promising and has been implemented clinically.

60 APPLIED LIFE SCIENCES↗