A Forward Multiparticle Spectrometer for the LHC: Hadron spectra and Long-lived particle search

I describe a possible Forward Multiparticle Spectrometer (FMS) that could be installed downstream of the superconducting recombination dipole D1 in Run 4, from z = 96 m - 126 m to measure multi-TeV hadron spectra in low luminosity p + p collisions at Rt(s) = 14 TeV, as well as p + O and O + O collisions as relevant for cosmic ray showers. Light antinuclei and charmed hadrons at high Feynman xF can be measured, both of importance for astrophysics. At the full high luminosity HL-LHC a search for new long-lived neutral particles (LLPs) decaying in a 20 m long, 70 cm diameter vacuum pipe to visible decay modes (including gamma+gamma, e+e-, mu+mu-, tau+tau-, ccbar and jets) can be made. The FMS is especially well suited for LLPs with 1 GeV < M(X)< 10 GeV and lifetimes c.tau from about 10 m to several km. I discuss this as a possible addition to CMS but it has no formal approval yet, therefore the talk is not given on behalf of CMS.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurements of pion production in eA with the CLAS detector

Preliminary results on semi-inclusive charged pion production in eA collisions at E{sub beam}=5 GeV/c{sup 2} are presented. The data were collected using the CLAS detector, which is a multipurpose, large acceptance, magnetic spectrometer located in Hall B at the Thomas Jefferson National Accelerator Facility. Selected distributions in W, Q{sup 2}, p{sub π}, and θ{sub π} are shown for data produced using deuterium, carbon, iron and lead targets. Preliminary comparisons with data simulated using the GENIE generator are made. The motivation for this work is to provide distributions useful for tuning the hadronic final state interaction models in order to reduce uncertainties in the results extracted from current and next-generation neutrino oscillation experiments.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Photoproduction of Cascade Baryons Using the GlueX Detector at Jefferson Laboratory

Multi-strange baryons have played an important role in understanding the strong interaction. Despite their importance to advancing quantum chromodynamics (QCD), little is known about such hyperons due to the lack of a strange probe. Almost all knowledge of Cascade baryons today stems from kaon-nucleon interactions in bubble chamber experiments performed in the 1960s and 1970s. The 1980s saw advancement in electronics and computational resources allowing for higher statistic experiments such as the MultiParticle Spectrometer (MPS) at Brookhaven National Laboratory. From these previous experiments, the octet and decuplet ground states, Xi(1320) and Xi(1530) respectively, were well established with known properties and four excited states were well established. This research uses the GlueX experiment at Jefferson Laboratory to extend photoproduction cross section measurements for Xi(1320)- to higher beam energies to further understand the production mechanism, as well as to search for the first excited Cascade resonance observation in photoproduction through the decay Xi-* -> K-Lambda. The GlueX Spectrometer is a nearly hermetic detector used to study exclusive photoproduction reactions with photon beam energies up to 12 GeV. The first phase of GlueX running has recently been completed. Preliminary results for the total cross section and differential cross sections in terms of momentum transfer -t are shown within. Additionally, the first observation of an excited Cascade baryon, in particular Xi(1820)-, is shown.

Ernst, Ashley↗

Dark Matter Indirect Search: The PAMELA Experiment

The instrument PAMELA, in orbit since June 15th, 2006, on board the Russian satellite Resurs DK1, is daily delivering to ground 16 Gigabytes of data. The apparatus is designed to study charged particles in the cosmic radiation, with a particular focus on antiparticles for searching antimatter and signals of dark matter annihilation. A combination of a magnetic spectrometer and different detectors allows antiparticles to be reliably identified from a large background of other charged particles. New results on the antiproton-to-proton and positron-to-all electron ratios over a wide energy range (1-100 GeV) are presented. While the antiproton-to-proton ratio does not show significant differences from standard secondary production, in the positron-to-all electron ratio an enhancement is clearly seen at energies above 10 GeV. Possible interpretations of this effect are briefly discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Use of Resistive Plate Chambers in the Upgrade of the PHENIX Forward Spectrometers

Resistive Plate Chambers (RPCs) are being used for a number of applications outside of the fields of nuclear and particle physics. These include large arrays for neutrino detection and various imaging applications. A brief summary of RPC applications will be given, but the talk will focus on the specific application of a muon trigger upgrade for the PHENIX experiment at the Relativistic Heavy Ion Collider (RHIC). A large portion of the RHIC scientific program is devoted to a study of the origin of the proton spin. A part of this program is to determine the contribution to the proton spin of the up and down quarks and anti quarks. The PHENIX experiment will study these contributions using the forward muon spectrometers to observe muons from the decay of W bosons produced in the collision of 100 and 250 GeV polarized protons. Due to the high muon backgrounds the forward spectrometer triggers will be upgraded using a series of RPCs with bakelite gaps to track charged particles and provide prompt signals for the trigger. The layout for the upgraded spectrometers will be given along with a discussion of the background rejection expected. A series of RPC prototypes have been built and testing procedures will be discussed. Test results on timing, efficiency and spatial resolution will be shown.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The energy dependence of the pp {yields} K{sup +}n{Sigma}{sup +} reaction

The energy dependence of the total cross section for the pp {yields} K{sup +}n{Sigma}{sup +} reaction has been investigated at the magnetic spectrometer COSY-ANKE. Signals from the production of the {Sigma}{sup +} hyperon were searched for in three simultaneously measured spectra. The values obtained for the total production cross section {sigma}({Sigma}{sup +}) are slightly below those of {sigma}({Sigma}{sup 0}) at the same excess energies. They follow a phase space dependence and do not show any evidence for strong threshold effects or a significant n{Sigma}{sup +} final state interaction.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Coupling Gammasphere and ORRUBA

The coincident detection of particles and gamma rays allows the study of the structure of exotic nuclei via inverse kinematics reactions using radioactive ion beams and thick targets. We report on the status of the project to couple the highresolution charged-particle detector ORRUBA to Gammasphere, a high-efficiency, high-resolution gamma ray detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

12 GeV detector technology at Jefferson Lab

The Thomas Jefferson National Accelerator Facility (JLab) is presently in the middle of an upgrade to increase the energy of its CW electron beam from 6 GeV to 12 GeV along with the addition of a fourth experimental hall. Driven both by necessity and availability, novel detectors and electronics modules have been used in the upgrade. One such sensor is the Silicon Photomultiplier (SiPM), specifically a Multi-Pixel Photon Counter (MPPC), which is an array of avalanche photodiode pixels operating in Geiger mode that are used to sense photons. The SiPMs replace conventional photomultiplier tubes and have several distinct advantages including the safe operation in a magnetic field and the lack of need for high voltage. Another key to 12 GeV success is advanced fast electronics. Jlab will use custom 250 MHz and 125 MHz 12-bit analog to digital converters (ADCs) and time to digital converters (TDCs) all of which take advantage of VME Switched Serial (VXS) bus with its GB/s high bandwidth readout capability. These new technologies will be used to readout drift chambers, calorimeters, spectrometers and other particle detectors at Jlab once the 12 GeV upgrade is complete. The largest experiment at Jlab utilizing these components is GlueX - an experiment in the newly constructed Hall D that will study the photoproduction of light mesons in the search for hybrid mesons. The performance of these components and their respective detectors will be presented.

43 PARTICLE ACCELERATORS↗

Charm Factories: Present and Future

The next generation tau-charm factory, the third Beijing Electron Spectrometer (BESIII) at the new Beijing Electron Positron Collider (BEPCII), has begun data collection. I discuss the flavor physics reach of the BESIII charm program and conclude with a discussion on future proposed tau-charm facilities.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Simulation of background from low-level tritium and radon emanation in the KATRIN spectrometers

The KArlsruhe TRItium Neutrino (KATRIN) experiment is a large-scale experiment for the model independent determination of the mass of electron anti-neutrinos with a sensitivity of 200 meV/c{sup 2}. It investigates the kinematics of electrons from tritium beta decay close to the endpoint of the energy spectrum at 18.6 keV. To achieve a good signal to background ratio at the endpoint, a low background rate below 10{sup −2} counts per second is required. The KATRIN setup thus consists of a high luminosity windowless gaseous tritium source (WGTS), a magnetic electron transport system with differential and cryogenic pumping for tritium retention, and electro-static retarding spectrometers (pre-spectrometer and main spectrometer) for energy analysis, followed by a segmented detector system for counting transmitted beta-electrons. A major source of background comes from magnetically trapped electrons in the main spectrometer (vacuum vessel: 1240 m{sup 3}, 10{sup −11} mbar) produced by nuclear decays in the magnetic flux tube of the spectrometer. Major contributions are expected from short-lived radon isotopes and tritium. Primary electrons, originating from these decays, can be trapped for hours, until having lost almost all their energy through inelastic scattering on residual gas particles. Depending on the initial energy of the primary electron, up to hundreds of low energetic secondary electrons can be produced. Leaving the spectrometer, these electrons will contribute to the background rate. This contribution describes results from simulations for the various background sources. Decays of {sup 219}Rn, emanating from the main vacuum pump, and tritium from the WGTS that reaches the spectrometers are expected to account for most of the background. As a result of the radon alpha decay, electrons are emitted through various processes, such as shake-off, internal conversion and the Auger deexcitations. The corresponding simulations were done using the KASSIOPEIA framework, which has been developed for the KATRIN experiment for low-energy electron tracking, field calculation and detector simulation. The results of the simulations have been used to optimize the design parameters of the vacuum system with regard to radon emanation and tritium pumping, in order to reach the stringent requirements of the neutrino mass measurement.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Radiopurity measurement of acrylic for DEAP-3600

The spherical acrylic vessel that contains the liquid argon target is the most critical detector component in the DEAP-3600 dark matter experiment. Alpha decays near the inner surface of the acrylic vessel are one of the main sources of background in the detector. A fraction of the alpha energy, or the recoiling nucleus from the alpha decay, could misreconstruct in the fiducial volume and result in a false candidate dark matter event. Acrylic has low levels of inherent contamination from {sup 238}U and {sup 232}Th. Another background of particular concern is diffusion of {sup 222}Rn during manufacturing, leading to {sup 210}Pb contamination. The maximum acceptable concentrations in the DEAP-3600 acrylic vessel are ppt levels of {sup 238}U and {sup 232}Th equivalent, and 10{sup −8} ppt {sup 210}Pb. The impurities in the bulk acrylic will be measured by vaporizing a large quantity of acrylic and counting the concentrated residue with ultra-low background HPGe detectors and a low background alpha spectrometer. An overview of the acrylic assay technique is presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of the {gamma}p{yields}{eta}p Reaction with the Crystal Ball Detector at the Mainz Microtron (MAMI-C)

The {gamma}p{yields}{eta}p reaction has been measured with the Crystal Ball and TAPS multiphoton spectrometers in the energy range from the production threshold to 1.4 GeV (1.49{<=}W{<=}1.87 GeV). Bremsstrahlung photons produced by the 1.5-GeV electron beam of the Mainz Microtron MAMI-C and momentum analyzed by the Glasgow Tagging Spectrometer were used for the {eta}-meson production. Our accumulation of 3.8x10{sup 6} {gamma}p{yields}{eta}p{yields}3{pi}{sup 0}p{yields}6{gamma}p events allows a detailed study of the reaction dynamics. The {gamma}p{yields}{eta}p differential cross sections were determined for 120 energy bins and the full range of the production angles. Our data show a dip near W = 1680 MeV in the total cross section related to a substantial dip in {eta} production at forward angles. The data are compared to predictions of previous SAID and MAID partial-wave analyses and to the latest SAID and MAID fits that included our data.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Diffraction news from CDF

We report updated results by the CDF II collaboration on diffractive W and Z production and preliminary results from a study of rapidity gaps between very forward jets.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Absolute neutrino mass scale determination with the KATRIN experiment

The aim of the KArlsruhe TRItium Neutrino experiment KATRIN is the direct and model independent determination of the absolute neutrino mass scale down to 0.2 eV. For this purpose, the integral electron energy spectrum will be measured close to the endpoint of molecular tritium beta decay. The electrostatic retardation method with magnetic adiabatic collimation (MAC-E filter) combines high energy resolution with high statistics and small background. The various components of the experiment (gaseous tritium source, pumping-transport system, pre- and main spectrometer, detector and rear system) are reviewed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The Light Scalar Mesons a{sub 0}/f{sub 0}(980) at COSY-Juelich

The light scalar mesons a{sub 0}/f{sub 0}(980) are being investigated at COSY-Juelich by detecting the strong decays into KK-bar and {pi}{eta}/{pi}{pi} as well as radiative decays into vector mesons. Selected results are discussed with emphasis on recent measurements at the ANKE and WASA spectrometers.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Simulation and Characterization of the MINER{nu}A Dipole Magnets

The MINER{nu}A (Main INjector ExpeRiment for {nu} A) experiment (http://minerva.fnal.gov/) is a neutrino scattering experiment which uses the NuMI beamline at Fermilab. It seeks to measure low energy neutrino interactions both to support neutrino oscillation experiments and to study the strong dynamics of the nucleon and nucleus that affect these interactions. For energy calibration of the main detector, a tertiary test beam line was designed and commissioned. This test beam consisted of target, collimator, two TOF stations and four wire chamber stations. Two dipole trim magnets were used to form a spectrometer. Here we present the simulation and characterization of these dipole magnets.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Study of the {sup 3}He-{eta} interaction

We present a summary of measurements of the dp{yields}{sup 3}HeX,(X {pi}{sup 0},{eta}) reactions performed with the COSY-11 facility. Our results for the dp{yields}{sup 3}He{eta} total cross sections confirm a strong enhancement observed in previous experiments close to the kinematical threshold. The forward-backward asymmetries of the differential cross sections deviate clearly from zero for center of mass momenta above 50 MeV/c indicating the presence of higher partial waves in the final state. The excitation function for the reaction dp{yields}{sup 3}He{pi}{sup 0} does not show any structure which could originate from the decay of the {sup 3}He-{eta} bound state. Our measurements do not confirm the cusp structure observed in the threshold excitation curve measured with the SPES-4 spectrometer in the vicinity of the {eta} production threshold.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗