Search NASA⌕ Search

SEARCH · Search NASA

Results for “MULTIPOLE TRANSITIONS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

The calculation of neutron capture gamma-ray yields for space shielding applications

The application of nuclear models to the calculation of neutron capture and inelastic scattering gamma yields is discussed. The gamma ray cascade model describes the cascade process in terms of parameters which either: (1) embody statistical assumptions regarding electric and magnetic multipole transition strengths, level densities, and spin and parity distributions or (2) are fixed by experiment such as measured energies, spin and parity values, and transition probabilities for low lying states.

Yost, K. J.↗

Broadening of the D lines and the relaxation of the resonance levels of sodium due to collisions with helium.

Calculated potentials for the NaHe molecule are used to obtain collision-induced widths and shifts for the sodium D lines together with cross sections for fine-structure transitions and the relaxation of the multipole polarizations of the resonance levels. The atomic collision is treated in an adiabatic approximation in which the colliding atoms form a molecular system which rotates during the collision. We find the resonance lines to be broadened equally and to be approximately 70% wider, and with associated shifts of an order of magnitude smaller, than expected on the basis of van der Waals forces. The dependence of the cross sections for relaxation of the multipole polarizations of the resonance levels on the molecular-coupling conditions and the rotation of the system during collision is discussed and indicates a limitation of the sum rule for these cross sections.

Lewis, E. L.↗

Modifying Operating Cycles to Increase Stability in a LITS

The short-term instability in the frequency of a linear-ion-trap frequency standard (LITS) can be reduced by modifying two cycles involved in its operation: (1) the bimodal (bright/dim) cycle of a plasma discharge lamp used for state preparation and detection and (2) a microwave-interrogation cycle. The purpose and effect of the modifications is to enable an increase in the microwave- interrogation cycle time, motivated by the general principle that the short-term uncertainty or instability decreases with increasing microwave-interrogation time. Stated from a slightly different perspective, the effect of modifications is to enable the averaged LITS readings to settle to their longterm stability over a shorter total observation time. The basic principles of a LITS were discussed in several NASA Tech Briefs articles. Here are recapitulated only those items of background information necessary to place the present modifications in context. A LITS includes a microwave local oscillator, the frequency of which is stabilized by comparison with the frequency of a ground-state hyperfine transition of Hg-199(+) ions. In a LITS of the type to which the modifications apply, the comparison involves a combination of optical and micro wave excitation and interrogation of the ions in two collinear ion traps: a quadrupole trap wherein the optical excitation used for state preparation and detection takes place, and a multipole (e.g., 12-pole) trap wherein the microwave interrogation of the clock transition takes place. The ions are initially loaded into the quadrupole trap and are thereafter shuttled between the two traps. This concludes the background information.

Burt, Eric↗

Magnetic optical activity in intense laser fields. I - Self-rotation and Verdet constant

The paper is concerned with the Faraday rotation and circular dichroism of dilute gases in longitudinal magnetic fields subject to strong radiation fields. In particular, magnetic fields are considered which produce Zeeman shifts much smaller than inverse collision times but which may be greater or smaller then the multipole relaxation times. Doppler broadening is considered, and explicit expressions are given for dipole transitions in a two-level system with arbitrary angular momentum for strong and weak magnetic fields. The same system is then studied as a function of the external magnetic-field strength with a fixed laser frequency. It is shown that this experimental arrangement, referred to as forward scattering, has certain advantages that are not present in the more usual magnetic rotation spectroscopy.

Giraud-Cotton, S.↗

Experimental Cross Sections for Excitation of the 2s S-2 yields 2p P-2 Transition in C(3+)

Experimental cross sections are presented for excitation of the 2s yields 2p transition in C(3+). Use is made of the energy-loss method with merged beams. Also described is use of a multipole "electronic aperture" to discriminate against elastically-scattered electrons. Comparisons are made with previous experimental energy-loss and optical-emission data, and with results of several theoretical calculations.

Chutjian, A.↗

Theoretical shell-model signatures in heavy-ion, coherent pion production

A comprehensive summary of a many-body, microscopic, particle-hole formalism is presented that describes coherent, subthreshold, pion production in peripheral, heavy-ion collisions. The formalism uses a new separable model transition interaction that produces Delta-hole states in either the projectile or target nucleus. Shell-model states described by harmonic oscillator functions are used in the calculation of Delta formation and decay and Lorentz-contraction effects of the nucleus not at rest are included. An analytical expression to lowest multipole order for the differential cross section is examined. The sensitivity of the theoretical results to the shell-model states is determined with preliminary shape results compared with data. The effects of higher multipoles are examined with attention paid to the second-order multipole value.

Maung, Khin M.↗

Suppressing Loss of Ions in an Atomic Clock

An improvement has been made in the design of a compact, highly stable mercury- ion clock to suppress a loss of ions as they are transferred between the quadrupole and higher multipole ion traps. Such clocks are being developed for use aboard spacecraft for navigation and planetary radio science. The modification is also applicable to ion clocks operating on Earth: indeed, the success of the modification has been demonstrated in construction and operation of a terrestrial breadboard prototype of the compact, highly stable mercury-ion clock. Selected aspects of the breadboard prototype at different stages of development were described in previous NASA Tech Briefs articles. The following background information is reviewed from previous articles: In this clock as in some prior ion clocks, mercury ions are shuttled between two ion traps, one a 16- pole linear radio-frequency trap, while the other is a quadrupole radio-frequency trap. In the quadrupole trap, ions are tightly confined and optical state selection from a 202Hg lamp is carried out. In the 16-pole trap, the ions are more loosely confined and atomic transitions are interrogated by use of a microwave beam at approximately 40.507 GHz. The trapping of ions effectively eliminates the frequency pulling that would otherwise be caused by collisions between clock atoms and the wall of a gas cell. The shuttling of the ions between the two traps enables separation of the state-selection process from the clock microwave-resonance process, so that each of these processes can be optimized independently of the other. This is similar to the operation of an atomic beam clock, except that with ions the beam can be halted and reversed as ions are shuttled back and forth between the two traps. When the two traps are driven at the same radio frequency, the strength of confinement can be reduced near the junction between the two traps, depending upon the relative phase of the RF voltage used to operate each of the two traps, and can cause loss of ions during each transit between the traps and thereby cause loss of the 40.507-GHz ion-clock resonance signal. The essence of the modification is to drive the two traps at different frequencies typically between 1.5 and 2 MHz for the quadrupole trap and a frequency a few hundred kHz higher for the 16- pole trap. A frequency difference of a few hundred kHz ensures that the ion motion caused by the trapping electric fields is small relative to the diameter of the traps. Unlike in the case in which both traps are driven at the same frequency, the trapping electric fields near the junction are not zero at all times; instead, the regions of low electric field near the junction open and close at the difference frequency. An additional benefit of making the 16-pole trap operate at higher frequency is that the strength or depth of the multipole trap can be increased independent of the quadrupole ion trap.

Prestage, John↗

The Primordial Inflation Polarization Explorer (PIPER): Current Status and Performance of the First Flight

The Primordial Inflation Polarization ExploreR (PIPER) is a balloon-borne instrument optimized to measure the polarization of the CMB at large angular scales. It will map 85% of the sky over a series of conventional balloon flights from the Northern and Southern hemispheres, measuring the B-mode polarization power spectrumover a range of multipoles from 2-300 covering both the reionization bump and the recombination peak, with sensitivity to measure the tensor-to-scalar ratio down to r = 0.007. PIPER will observe in four frequency bands centered at 200, 270, 350, and 600 GHz to characterize dust foregrounds. The instrument has background-limited sensitivity provided by fully cryogenic (1.7 K) optics focusing the sky signal onto kilo-pixel arrays of time-domain multiplexed Transition-Edge Sensor (TES) bolometers held at 100 mK. Polarization sensitivity and systematiccontrol are provided by front-end Variable-delay Polarization Modulators (VPMs). PIPER had its engineering flight in October 2017 from Fort Sumner, New Mexico. This papers outlines the major components in the PIPER system discussing the conceptual design as well as specific choices made for PIPER. We also report on the results of the engineering flight, looking at the functionality of the payload systems, particularly VPM, as well as pointing out areas of improvement.

Pawlyk, Samuel↗

Collisional redistribution of radiation. III - The equation of motion for the correlation function and the scattered spectrum

Computations were made of the scattering of monochromatic radiation by a degenerate atom in the binary-collision approximation for field strengths whose products of the Rabi frequency for atomic transition and the duration of a strong collision are much less than 1. An expression of motion for the correlation function is derived which does not exclude the region where thermal correlations may be neglected; the equation is valid outside the quantum-regression regime, and has a straightforward solution for practical cases. Solutions for the weak-field linear response regime are presented in terms of generalized absorption and emission profiles which depend on the indices of the atomic multipoles.

Burnett, K.↗

Multipole radiation in charged-particle scattering

This paper formulates the general problem of photon emission in particle scattering using a classical and quantum mechanical approach. The connection between the classical short collision time (SCT) and Born results is examined for various special classifications of problems. In the dipole case the two formulations yield results that can be expressed in the same form and for arbitrary scattering potential. For quadrupole emission the SCT and Born results are the same only for a short-range potential, however. The quadrupole problem is more sensitive to details in the process because the calculation requires an expansion of the total amplitude for the process to lowest order in the photon wave number or momentum. The special case of photon emission associated with spin-flip transitions during scattering is considered for spin-1/2 particles. Like classical magnetic dipole radiation, there is no infrared divergence feature for this type of emission.

Gould, Robert J.↗