Search NASA⌕ Search

SEARCH · Search NASA

Results for “MULTIWIRE PROPORTIONAL CHAMBERS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Multiwire proportional chamber development

The development of large area multiwire proportional chambers, to be used as high resolution spatial detectors in cosmic ray experiments is described. A readout system was developed which uses a directly coupled, lumped element delay-line whose characteristics are independent of the MWPC design. A complete analysis of the delay-line and the readout electronic system shows that a spatial resolution of about 0.1 mm can be reached with the MWPC operating in the strictly proportional region. This was confirmed by measurements with a small MWPC and Fe-55 X-rays. A simplified analysis was carried out to estimate the theoretical limit of spatial resolution due to delta-rays, spread of the discharge along the anode wire, and inclined trajectories. To calculate the gas gain of MWPC's of different geometrical configurations a method was developed which is based on the knowledge of the first Townsend coefficient of the chamber gas.

Doolittle, R. F.↗

Results obtained with position sensitive multiwire proportional chambers with helium, carbon, and oxygen nuclei

Spatial resolution performance results obtained at the Lawrence Radiation Laboratory Bevatron with prototype multiwire proportional chamber spatial detectors with integral delay line readout are presented. The effects due to incident nuclei charge, chamber operating parameters, chamber design, electronics, gas mixtures, and magnetic field presence have been investigated and are discussed.

Emming, J. G.↗

Sensing circuits for multiwire proportional chambers

Integrated sensing circuits were designed, fabricated, and packaged for use in determining the direction and fluence of ionizing radiation passing through a multiwire proportional chamber. CMOS on sapphire was selected because of its high speed and low power capabilities. The design of the proposed circuits is described and the results of computer simulations are presented. The fabrication processes for the CMOS on sapphire sensing circuits and hybrid substrates are outlined. Several design options are described and the cost implications of each discussed. To be most effective, each chip should handle not more than 32 inputs, and should be mounted on its own hybrid substrate.

Peterson, H. T.↗

Measurements of the performance of multiwire proportional chambers

Data are presented that may be useful in formulating engineering specifications and test procedures for the proportional counter hodoscope to be flown as part of the High Energy Cosmic Ray Experiment on the High Energy Astronomy Observatory (HEAO), Mission A. A collection of preliminary data taken in laboratory tests of multiwire counters with an anode wire spacing of 5 mm and cathode gap spacing of 1 cm is presented. The data are from laboratory development models or counters for balloon flights and were selected to illustrate several aspects of proper and improper counter performance. Most of the data were taken from a large proportional counter hodoscope which has an active area of 0.5 by 0.5 m and 104 wires per plane.

Austin, R. W.↗

Nuclear Science Symposium, 4th, and Nuclear Power Systems Symposium, 9th, San Francisco, Calif., October 19-21, 1977, Proceedings

Consideration is given to the following types of high energy physics instrumentation: drift chambers, multiwire proportional chambers, calorimeters, optical detectors, ionization and scintillation detectors, solid state detectors, and electronic and digital subsystems. Attention is also paid to reactor instrumentation, nuclear medicine instrumentation, data acquisition systems for nuclear instrumentation, microprocessor applications in nuclear science, environmental instrumentation, control and instrumentation of nuclear power generating stations, and radiation monitoring. Papers are also presented on instrumentation for the High Energy Astronomy Observatory.

Source record↗

Nuclear Science Symposium, 25th, and Symposium on Nuclear Power Systems, 10th, Washington, D.C., October 18-20, 1978, Proceedings

Detectors of various types are discussed, taking into account drift chambers, calorimetry, multiwire proportional chambers, signal processing, the use of semiconductors, and photo/optical applications. Circuits are considered along with instrumentation for space, nuclear medicine instrumentation, data acquisition and systems, environmental instrumentation, reactor instrumentation, and nuclear power systems. Attention is given to a new approach to high accuracy gaseous detectors, the current status of electron mobility and free-ion yield in high mobility liquids, a digital drift chamber digitizer system, the stability of oxides in high purity germanium, the quadrant photomultiplier, and the theory of imaging with a very limited number of projections.

Source record↗

Multiwire proportional counter development

A test run was made at the Bevatron to check the character of signals induced in an electromagnetic delay line capacitively coupled to the wire cathode plane of a multiwire proportional chamber. In particular, these signals and the behavior of the readout electronics as a function of associated delta-ray production are studied. These measurements are important in assessing the effect of delta-ray background on the spatial resolution attainable for the primary ions. Test results are used to design a multiwire proportional chamber and readout system for use as spatial detectors in a superconducting magnetic spectrometer experiment.

Source record↗

Patient-specific QA and delivery verification of scanned ion beam at NIRS-HIMAC

Purpose: To evaluate a patient-specific QA program and system for constancy checking of a scanning delivery system developed at the National Institute of Radiological Sciences.Methods: For the patient-specific QA, all the planned beams are recalculated on a water phantom with treatment planning software (TPS). The recalculated dose distributions are compared with the measured distributions using a 2D ionization chamber array at several depths, and evaluated using gamma index analysis with criteria of 3% and 3 mm and a pass rate of 90%. For the constancy check, the authors developed the multiwire proportional chamber (MWPC), which can record the delivered 2D fluence images in a slice-by-slice manner. During irradiation for dosimetric QA with the 2D ionization chamber array and an accordion-type water phantom, the 2D fluence images are recorded using the MWPC in the delivery system. These recorded images are then compared to those taken in the treatment session to check the constancy check. This analysis also employs gamma index analysis using the same criteria as in the patient-specific QA. These patient-specific QA and constancy check evaluations were performed using the data of 122 patients.Results: In the patient-specific QA, the measured dose distributions agreed well with those calculated by the TPS, and the QA criteria were satisfied in all measurements. The additional check of the fluence comparison ensured the constancy of the delivered field during each treatment irradiation.Conclusions: The authors established a patient-specific QA program and additional check of delivery constancy in every treatment session. Fluence comparison is a strong tool for constancy checking of the delivery system.

61 RADIATION PROTECTION AND DOSIMETRY↗

Structure effects in polarization and cross sections for A(p, p’)X inelastic reactions on {sup 40}Ca and {sup 12}C nuclei at 1 GeV

The polarization of secondary protons in the (p, p’) inelastic reactions on {sup 40}Ca and {sup 12}C nuclei at the initial proton energy of 1 GeV was measured over a wide range of scattered-proton momenta at a laboratory angle of Θ = 21°. The reaction cross sections were also measured. Scattered protons were detected by means of magnetic spectrometer equipped with a polarimeter based on multiwire-proportional chambers. A structure in the polarization and cross-section data, which is probably related to scattering off nucleon correlations in the nuclei involved, was observed.

74 ATOMIC AND MOLECULAR PHYSICS↗

Polarization effects in the quasielastic (p, 2p) reaction with the nuclear S-Shell Protons at 1 GeV

The polarization of the secondary protons in the (p, 2p) reaction with the S-shell protons of nuclei {sup 4}He, {sup 6}Li, {sup 12}C, {sup 28}Si, {sup 40}Ca was measured at 1 GeV unpolarized proton beam. The spin correlation parameters C{sub ij} for the {sup 4}He and {sup 12}C targets also were for the first time obtained as well. The polarization measurements were performed by means of a two-arm magnetic spectrometer, each arm of which was equipped with the multiwire-proportional chamber polarimeter. This experiment was aimed to study a modification of the proton-proton scattering matrix in the nuclear medium.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Study of Inelastic A(p, p′)X Reaction with Nuclei at 1 GeV

The secondary-proton polarization and differential cross sections for the (p, p') inelastic reaction on {sup 28}Si and {sup 56}Fe nuclei at the initial proton energy of 1 GeV were measured over a wide range of the scattered-proton momenta at a laboratory angle of Θ = 21◦. Scattered protons were detected by means of a magnetic spectrometer equipped with a polarimeter based on multiwire proportional chambers and a carbon analyzer. A structure in the polarization and cross section data, which is probably related to quasielastic scattering off nucleon correlations in the {sup 28}Si and {sup 56}Fe nuclei, was observed as earlier in the analogous data for {sup 12}C and {sup 40}Ca nuclei. Momentum intervals within which cross-section ratios for nuclei did not depend on the scattered-proton momentum were found.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Detector for measuring the π + → e + v branching fraction

The PIENU experiment at TRIUMF is aimed at a measurement of the branching ratio R e/u = Γ((π + → e + v e ) + (π + → e + v e γ))/Γ((π + → μ + v μ ) + (π + → μ + v μ γ)) with precision < 0.1%. Incident pions, delivered at the rate of 60 kHz with momentum 75 MeV/c, were degraded and stopped in a plastic scintillator target. Pions and their decay product positrons were detected with plastic scintillators and tracked with multiwire proportional chambers and silicon strip detectors. The energies of the positrons were measured in a spectrometer consisting of a large NaI(Tℓ) crystal surrounded by an array of pure CsI crystals. This paper provides a description of the PIENU experimental apparatus and its performance in pursuit of R e/u

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Centrality-Dependent Modification of Jet-Production Rates in Deuteron-Gold Collisions at s N N = 200 GeV

We measured jet production rates in p+p and d+Au collisions at s N N = 200 GeV recorded in 2008 with the PHENIX detector at the Relativistic Heavy Ion Collider. Jets are reconstructed using the R=0.3 anti-k t algorithm from energy deposits in the electromagnetic calorimeter and charged tracks in multiwire proportional chambers, and the jet transverse momentum (p T ) spectra are corrected for the detector response. Spectra are reported for jets with 12 T <50 GeV/c, within a pseudorapidity acceptance of |η|<0.3. The nuclear-modification factor (R dAu ) values for 0%–100% d+Au events are found to be consistent with unity, constraining the role of initial state effects on jet production. Nonetheless, the centrality-selected R dAu values and central-to-peripheral ratios (R CP ) show large, p T -dependent deviations from unity, challenging the conventional models that relate hard-process rates and soft-particle production in collisions involving nuclei.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The efficient identification of relativistic particles by transition radiation

A system of transition radiation detectors has been constructed and exposed to beams of electrons and pions in the energy range of 3 to 15 GeV at SLAC. Transition radiation was generated in a variety of stacks of mylar foils (radiators), and its intensity was detected with 7 multiwire proportional chambers. The raw data demonstrate a good separation between electron and pion induced signals. A more detailed analysis shows that a very efficient identification of individual particles is possible. Typically, a detection efficiency for electrons above 90%, combined with a pion-electron discrimination ratio of .001, has been achieved. Some conclusions with respect to the design of a practical detector for relativistic particles are drawn.

Cherry, M. L.↗