Search NASA⌕ Search

SEARCH · Search NASA

Results for “MUONS PLUS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Kinematic distributions for electron pair production by muons

Cross sections and kinematic distributions for the trident production process plus or negative muon plus charge yields plus or minus muon plus electron plus positron plus charge (with charge = dipion moment and Fe) are given for beam energies of 100 to 300 GeV at fixed (electron positron) masses from 5 to 15 GeV. This process is interesting as a test of quantum electrodynamics at high energies, and in particular as a test of the form of the photon propagator at large timelike (four-momentum) squared. For this purpose, it is desirable to impose kinematic cuts that favor those Bethe-Heitler graphs which contain a timelike photon propagator. It is found that there are substantial differences between the kinematic distributions for the full Bethe-Heitler matrix element and the distributions for the two timelike-photon graphs alone; these differences can be exploited in the selection of appropriate kinematic cuts.

Linsker, R.↗

Charge Resolution of the Silicon Matrix of the ATIC Experiment

ATIC (Advanced Thin Ionization Calorimeter) is a balloon borne experiment designed to measure the cosmic ray composition for elements from hydrogen to iron and their energy spectra from approx.50 GeV to near 100 TeV. It consists of a Si-matrix detector to determine the charge of a CRT particle, a scintillator hodoscope for tracking, carbon interaction targets and a fully active BGO calorimeter. ATIC had its first flight from McMurdo, Antarctica from 28/12/2000 to 13/01/2001. The ATIC flight collected approximately 25 million events. The silicon matrix of the ATIC spectrometer is designed to resolve individual elements from proton to iron. To provide this resolution careful calibration of each pixel of the silicon matrix is required. Firstly, for each electronic channel of the matrix the pedestal value was subtracted taking into account its drift during the flight. The muon calibration made before the flight was used then to convert electric signals (in ADC channel number) to energy deposits in each pixel. However, the preflight muon calibration was not accurate enough for the purpose, because of lack of statistics in each pixel. To improve charge resolution the correction was done for the position of Helium peak in each pixel during the flight . The other way to set electric signals in electronics channels of the Si-matrix to one scale was correction for electric channel gains accurately measured in laboratory. In these measurements it was found that small different nonlinearities for different channels are present in the region of charge Z > 20. The correction for these non-linearities was not done yet. In linear approximation the method provides practically the same resolution as muon calibration plus He-peak correction. For searching a pixel with the signal of primary particle an indication from the cascade in the calorimeter was used. For this purpose a trajectory was reconstructed using weight centers of energy deposits in BGO layers. The point of intersection of this trajectory with Si-matrix and its RMS was determined. The pixel with maximal signal in 3sigma region was taken as sought. The signal in this pixel was corrected by trajectory zenith angle. The preliminary results on charge resolution of the Si-matrix in the range from protons to iron are presented.

Zatsepin, V. I.↗

Formation of the muonic helium atom /alpha particle-muon-electron/ and observation of its Larmor precession

Experiments are described in which it proved possible to form the muonic helium atom by stopping polarized negative muons in a helium gas with a 2% xenon admixture at a pressure of 14 atm. The observed Larmor precession amplitudes are plotted against the gyromagnetic ratio for both muons and antimuons stopped in He + 2% Xe. In addition, a non-zero residual polarization of 0.06 plus or minus 0.01 was measured for muons stopped in pure helium gas, which corresponds to a depolarization factor of 18 plus or minus 3.

Souder, P. A.↗

Phenomenological model of nuclear primary air showers

The development of proton primary air showers is described in terms of a model based on a hadron core plus an electromagnetic cascade. The muon component is neglected. The model uses three parameters: a rate at which hadron core energy is converted into electromagnetic cascade energy and a two-parameter sea-level shower-age function. By assuming an interaction length for the primary nucleus, the model is extended to nuclear primaries. Both models are applied over the energy range from 10 to the 13th power to 10 to the 21st power eV. Both models describe the size and age structure (neglecting muons) from a depth of 342 to 2052 g/sq cm.

Tompkins, D. R., Jr.↗

Neutrino production from the solar atmosphere

When the high energy primary cosmic rays enter near the solar surface, they pass through a thick matter but having a low density. If the density and path length satisfy an appropriate condition, the primaries collide with the constituents near the solar sphere (almost protons) and produce pions and kaons, most of which decay into mu plus nu sub mu without successive hadron collisions. Muons also decay into NU sub mu and NU sub e before reaching the Earth. The neutrino flux of which the producer is matter near the solar surface is computed by solving cascade diffusion equations. The calculated differential flux of muon neutrino at 1 TeV is 1 X 10 to the minus 13 power (GeV. cm square centimeters 2.s.ster)(-1) which is rather difficult to be observed in the present apparatuses or DUMAND.

Inazawa, H.↗

Evidence of muonium formation using thin gold foils in vacuum

The production of thermal muonium in a vacuum region has been investigated using an array of 200 thin (about 1000 A thick) gold foils exposed to a stopping positive-muon beam. By examining the observed time dependence of the positive-muon decay spectra in various transverse magnetic field, it is estimated that the lower limit of the probability of muonium formation by these gold foils placed in vacuum was 0.28 plus or minus 0.05.

Barnett, B. A.↗

Muon spin rotation studies

The bulk of the muon spin rotation research work centered around the development of the muon spin rotation facility at the Alternating Gradient Synchrotron (AGS) of Brookhaven National Laboratory (BNL). The collimation system was both designed and fabricated at Virginia State University. This improved collimation system, plus improvements in detectors and electronics enabled the acquisition of spectra free of background out to 15 microseconds. There were two runs at Brookhaven in 1984, one run was devoted primarily to beam development and the other run allowed several successful experiments to be performed. The effect of uniaxial strain on an Fe(Si) crystal at elevated temperature (360K) was measured and the results are incorporated herein. A complete analysis of Fe pulling data taken earlier is included.

Source record↗