At least 19 records

Inverse load calculation procedure for offshore wind turbines and application to a 5‐MW wind turbine support structure

Abstract A significant number of wind turbines installed today have reached their designed service life of 20 years, and the number will rise continuously. Most of these turbines promise a more economical performance if they operate for more than 20 years. To assess a continued operation, we have to analyze the load‐bearing capacity of the support structure with respect to site‐specific conditions. Such an analysis requires the comparison of the loads used for the design of the support structure with the actual loads experienced. This publication presents the application of a so‐called inverse load calculation to a 5‐MW wind turbine support structure. The inverse load calculation determines external loads derived from a mechanical description of the support structure and from measured structural responses. Using numerical simulations with the software fast , we investigated the influence of wind‐turbine‐specific effects such as the wind turbine control or the dynamic interaction between the loads and the support structure to the presented inverse load calculation procedure. fast is used to study the inverse calculation of simultaneously acting wind and wave loads, which has not been carried out until now. Furthermore, the application of the inverse load calculation procedure to a real 5‐MW wind turbine support structure is demonstrated. In terms of this practical application, setting up the mechanical system for the support structure using measurement data is discussed. The paper presents results for defined load cases and assesses the accuracy of the inversely derived dynamic loads for both the simulations and the practical application. Copyright © 2017 John Wiley & Sons, Ltd.

Pahn, T.↗

Predicting the performance uncertainty of a 1-MW pilot-scale carbon capture system after hierarchical laboratory-scale calibration and validation

A challenging problem in designing pilot-scale carbon capture systems is to predict, with uncertainty, the adsorber performance and capture efficiency under various operating conditions where no direct experimental data exist. Motivated by this challenge, we previously proposed a hierarchical framework in which relevant parameters of physical models were sequentially calibrated from different laboratory-scale carbon capture unit (C2U) experiments. Specifically, three models of increasing complexity were identified based on the fundamental physical and chemical processes of the sorbent-based carbon capture technology. Results from the corresponding laboratory experiments were used to statistically calibrate the physical model parameters while quantifying some of their inherent uncertainty. The parameter distributions obtained from laboratory-scale C2U calibration runs are used in this study to facilitate prediction at a larger scale where no corresponding experimental results are available. In this paper, we first describe the multiphase reactive flow model for a sorbent-based 1-MW carbon capture system then analyze results from an ensemble of simulations with the upscaled model. The simulation results are used to quantify uncertainty regarding the design’s predicted efficiency in carbon capture. In particular, we determine the minimum gas flow rate necessary to achieve 90% capture efficiency with 95% confidence.

bubbling bed↗

On a burning plasma low recycling regime with P DT = 23–26 MW, Q DT = 5–7 in a JET-like tokamak

The recent invention of a continuously flowing liquid lithium system, called 24/7-FLiLi, opens the opportunity to design a plasma pumping divertor which can significantly suppress plasma edge cooling by recycling. The paper describes the expected performance of deuterium–tritium burning plasma with low recycling using a tokamak of JET size, magnetic field and plasma current as an example. So far, only the technological aspects of flowing lithium have been tested on the HT-7 and EAST tokamaks (ASIPP, Hefei, China) with no attempts to create the low recycling regime. The compatibility of 24/7-FLiLi with tokamak plasma was confirmed and some mistakes in the design were revealed, thus, requiring another fabrication approach. Now, with the proper design of the Li system, recycling as low as 0.5 seems to be achievable. The suppression of plasma cooling by recycling in combination with neutral beam injection (NBI) for core plasma fueling by energetic particles automatically leads to ‘the best possible confinement regime’, uniquely compatible with burning plasma. This paper outlines the conceptual details of the 24/7-FLiLi divertor for a JET size tokamak. The main focus is in regard to the physics of the low recycling regime as well as to the expected performance of the burning plasma. In comparison with the results of 1994 on TFTR and 1997 on JET, the projected performance is astonishing: fusion power P DT = 23–26 MW, fusion efficiency Q DT = 5.7 – 6.4, tritium burn up 7.8%–8.7% with modest NBI power P NBI = 4 MW, and energy E NBI = 120 keV. Furthermore, this new regime could resolve the outstanding plasma physics issues related to burning plasma that are unsolvable with the currently dominant approach.

24/7-FLiLi↗

A Direct Ammonia Fuel Cell with a KOH-Free Anode Feed Generating 180 mW cm −2 at 120 °C

The motivations to operate the direct ammonia fuel cell (DAFC) with no addition of aqueous base, include facilitated fuel management and prevention of corrosion and shunt currents in the DAFC stack. We describe here a polymer electrolyte DAFC, operating at a cell temperature (T cell ) of 120 °C on ammonia and water alone as anode feed, that demonstrated peak power of 180 mW cm −2 —a record for this type of fuel cell. We offer a detailed analysis of polarization curves recorded for PE-DAFCs in the T cell range of 60 °C–120 °C, allowing to estimate the effects of KOH-free operation on the ionic and faradaic resistances, R i and R F , that determine together the value of R app , CL – an , the apparent resistance of the anode catalyst layer. The latter resistance drops ten times between 60 °C and 120 °C as result mainly of the drop in R F . Consequently, DAFC performance at T cell > 100 °C improves substantially, including the cell performance on a KOH-free anode feed. The demsontrated performance levels reported here for KOH-free DAFCs support further development of this type of ammonia/air fuel cells.

Achrai, Ben↗

Optimized Generator Designs for the DTU 10-MW Offshore Wind Turbine using GeneratorSE

Compared to land-based applications, offshore wind imposes challenges for the development of next generation wind turbine generator technology. Direct-drive generators are believed to offer high availability, efficiency, and reduced operation and maintenance requirements; however, previous research suggests difficulties in scaling to several megawatts or more in size. The resulting designs are excessively large and/or massive, which are major impediments to transportation logistics, especially for offshore applications. At the same time, geared wind turbines continue to sustain offshore market growth through relatively cheaper and lightweight generators. However, reliability issues associated with mechanical components in a geared system create significant operation and maintenance costs, and these costs make up a large portion of overall system costs offshore. Thus, direct-drive turbines are likely to outnumber their gear-driven counterparts for this market, and there is a need to review the costs or opportunities of building machines with different types of generators and examining their competitiveness at the sizes necessary for the next generation of offshore wind turbines. In this paper, we use GeneratorSE, the National Renewable Energy Laboratory's newly developed systems engineering generator sizing tool to estimate mass, efficiency, and the costs of different generator technologies satisfying the electromagnetic, structural, and basic thermal design requirements for application in a very large-scale offshore wind turbine such as the Technical University of Denmark's (DTU) 10-MW reference wind turbine. For the DTU reference wind turbine, we use the previously mentioned criteria to optimize a direct-drive, radial flux, permanent-magnet synchronous generator; a direct-drive electrically excited synchronous generator; a medium-speed permanent-magnet generator; and a high-speed, doubly-fed induction generator. Preliminary analysis of leveled costs of energy indicate that for large turbines, the cost of permanent magnets and reliability issues associated with brushes in electrically excited machines are the biggest deterrents for building direct-drive systems. The advantage of medium-speed permanent-magnet machines over doubly-fed induction generators is evident, yet, variability in magnet prices and solutions to address reliability issues associated with gearing and brushes can change this outlook. This suggests the need to potentially pursue fundamentally new innovations in generator designs that help avoid high capital costs but still have significant reliability related to performance.

17 WIND ENERGY↗

Development of a 5 MW reference gearbox for offshore wind turbines: 5 MW reference gearbox

This paper presents detailed descriptions, modeling parameters and technical data of a 5MW high-speed gearbox developed for the National Renewable Energy Laboratory offshore 5MW baseline wind turbine. The main aim of this paper is to support the concept studies and research for large offshore wind turbines by providing a baseline gearbox model with detailed modeling parameters. This baseline gearbox follows the most conventional design types of those used in wind turbines. It is based on the four-point supports: two main bearings and two torque arms. The gearbox consists of three stages: two planetary and one parallel stage gears. The gear ratios among the stages are calculated in a way to obtain the minimum gearbox weight. The gearbox components are designed and selected based on the offshore wind turbine design codes and validated by comparison to the data available from large offshore wind turbine prototypes. All parameters required to establish the dynamic model of the gearbox are then provided. Moreover, a maintenance map indicating components with high to low probability of failure is shown. The 5 MW reference gearbox can be used as a baseline for research on wind turbine gearboxes and comparison studies. It can also be employed in global analysis tools to represent a more realistic model of a gearbox in a coupled analysis.

17 WIND ENERGY↗

Effects of wind field characteristics on pitch bearing reliability: a case study of 5 MW reference wind turbine at onshore and offshore sites; Auswirkungen von Windfeldeigenschaften auf die Zuverlässigkeit von Rotorblattlagern: eine Fallstudie über eine 5-MW-Referenz-Windkraftanlage an Onshore- und Offshore-Standorten

This paper presents a study on pitch bearing basic rating life affected by wind field characteristics at both onshore and offshore wind sites. The National Renewable Energy Laboratory 5 MW reference wind turbine is selected for the study. Wind field characteristics including reference hub height mean wind speed, wind speed distribution, wind shear, and vertical inflow are studied. A decoupled approach is employed where global analysis is performed first. Second, the load effects from the global analysis are applied on a reference pitch bearing designed based on best industrial practices. For the case study onshore site, it is found that the Kernel density estimation best fits the wind distribution, while the International Electrotechnical Commission proposed distribution appears to be not suitable. Moreover, it is shown that the seed number has high effect on the bearing life in turbulence wind and the wind speeds around rated have the highest contribution in both bearing fatigue damage and extreme load failure. The results contribute to better understanding of the wind field characteristics on the pitch bearing life.

17 WIND ENERGY↗

System design of a 1 MW north-facing, solid particle receiver

Falling solid particle receivers (SPR) utilize small particles as a heat collecting medium within a cavity receiver structure. The components required to operate an SPR include the receiver (to heat the particles), bottom hopper (to catch the falling particles), particle lift elevator (to lift particles back to the top of the receiver), top hopper (to store particles before being dropped through the receiver), and ducting. In addition to the required components, there are additional features needed for an experimental system. These features include: a support structure to house all components, calibration panel to measure incident radiation, cooling loops, and sensors (flux gages, thermocouples, pressure gages). Each of these components had to be designed to withstand temperatures ranging from ambient to 700 °C. Thermal stresses from thermal expansion become a key factor in these types of high temperature systems. The SPR will be housing ~3000 kg of solid particles. The final system will be tested at the National Solar Thermal Test Facility in Albuquerque, NM.

14 SOLAR ENERGY↗

Toward Robust and Routine Determination of Mw for Small Earthquakes: Application to the 2020 Mw 5.7 Magna, Utah, Seismic Sequence

To better characterize seismic hazard, particularly, for induced seismicity, there is an increasing interest in methods to estimate moment magnitude (M w ) for small earthquakes. M w is generally preferred over other magnitude types, but, it is difficult to estimate M w for earthquakes with local magnitude (M L ) <3-3.5, using conventional moment tensor (MT) inversion. The 2020 M ww 5.7 Magna, Utah, seismic sequence provides an opportunity to illustrate and evaluate the value of spectral methods for this purpose. Starting with a high-quality seismic catalog of 2103 earthquakes (M L <5.6), we estimate M w using two independent spectral methods—one based on direct waves, yielding M w,direct , and the other based on coda waves, yielding M w,coda . For the direct-wave method, we present a non-parametric (NP) inversion scheme that solves for apparent geometrical spreading, G(R), and site effects (S), similar to other NP procedures that have been used to calibrate regional M L scales. The NP inversion is constrained using M ws derived from MTs for nine events in the Magna sequence. We recover statistically robust and physically reasonable G(R) and S and compute M w,direct for 635 Magna earthquakes down to M L 0.7. For the coda-wave method, we consider two separate calibration schemes involving previous MT solutions and compute M w,coda for 311 earthquakes down to M L 1.0. For 280 of the events that were processed with both methods—M w,direct and M w,coda —are strongly correlated (r = 0.98), with a mean difference of only 0.05. We compare M w,direct and M w,coda with M L and find reasonably good agreement for M L <3.6 with the theoretically predicted relationship of M w =(2/3)M L +C, in which C is a regional constant. Our results imply that seismic network operators can use spectral-based M w estimates to replace M L estimates for events with M L ≥1.0, and possibly smaller. The main requirement is the existence of a small number of MT solutions for calibration purposes.

58 GEOSCIENCES↗

Fatigue analysis of the Spallation Neutron Source 2 MW target design

Upgrades to the Spallation Neutron Source (SNS) at Oak Ridge National Laboratory are under way with two major projects. The first project is the Proton Power Upgrade (PPU), which will double the power capacity of the SNS accelerator system to enable the operation of a future second neutron source target station—the second project. PPU also will increase power to the SNS first target station – which currently operates at 1.4 MW with 1.0 GeV protons – to 2 MW with 1.3 GeV protons. Final design of the PPU 2 MW target module is finished, including all necessary design and analysis calculations. The fatigue evaluation described herein is an assessment of the fitness of the PPU 2 MW target mercury vessel to resist failure from cyclic loading from the pulsed 60 Hz proton beam and thermal changes from disrupted operation. In addition to the reliability predictions, the method, detail, and depth of this fatigue evaluation are superior to those of past target design assessments. Furthermore, the thermal fatigue life is predicted to exceed 3125 thermal cycles per 1250 h of operation for all load cases. The design also meets the (relative) fatigue design goal for combined thermal and pulse loading of greater than 0.5 times the minimum fatigue life calculated for a jet-flow target design operating at 1.4 MW—the most robust design to date in terms of resistance to fatigue failure. From the onset of the PPU, it has been known that pulse loading requires effective application of helium gas injection into the target mercury to reduce beam pressure loading. For the PPU 2 MW target, none of the pulse load cases requires a maximum strain reduction from gas injection of more than 50% (for base material) to meet the fatigue design goal. This level of reduction is achievable from gas injection, according to historical strain measurements from 1.4 MW target operation. Overall, the PPU 2 MW target design is predicted to have superior resistance to fatigue failure compared with past target designs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Downwind coning concept rotor for a 25 MW offshore wind turbine

The size of offshore wind turbines over the next decade is expected to continually increase due to reduced balance of station costs per MW and also the higher wind energy at increased altitudes that can lead to higher capacity factors. However, there are challenges that may limit the degree of upscaling which is possible. In this paper, a two-bladed downwind turbine system is upscaled from 13.2 MW to 25 MW, by redesigning aerodynamics, structures, and controls. In particular, three 25 MW rotors have been developed: V1 is the upscaled model, V2 is a partial redesigned model, and V3 is a fully redesigned model. Despite their radically large sizes, it is found that these 25 MW turbine rotors satisfy this limited set of design drivers at the rated condition and that larger blade lengths are possible with cone-wise load-alignment. In addition, flapwise morphing (varying the cone angle with a wind-speed schedule) is investigated in terms of minimizing mean and fluctuating root bending loads using steady inflow proxies for the maximum and damage equivalent load moments. The resulting series of 25 MW rotors, which are the largest ever designed, can be a useful baseline for additional development and assessment.

17 WIND ENERGY↗

Exploring the interaction between the MW and LMC with a large sample of blue horizontal branch stars from the DESI survey

The Large Magellanic Cloud (LMC) is a Milky Way (MW) satellite that is massive enough to gravitationally attract the MW disc and inner halo, causing significant motion of the inner MW with respect to the outer halo. In this work, we probe this interaction by constructing a sample of 9866 blue horizontal branch (BHB) stars with radial velocities from the DESI spectroscopic survey out to 120 kpc from the Galactic centre. This is the largest spectroscopic set of BHB stars in the literature to date, and it contains four times more stars with Galactocentric distances beyond 50 kpc than previous BHB catalogues. Using the DESI BHB sample combined with SDSS BHBs, we measure the bulk radial velocity of stars in the outer halo and observe that the velocity in the Southern Galactic hemisphere is different by 3.7σ from the North. Modelling the projected velocity field shows that its dipole component is directed at a point 22 deg away from the LMC along its orbit, which we interpret as the travel direction of the inner MW. The velocity field includes a monopole term that is –24 km s –1 ⁠, which we refer to as compression velocity. This velocity is significantly larger than predicted by the current models of the MW and LMC interaction. This work uses DESI data from its first 2 yr of observations, but we expect that with upcoming DESI data releases, the sample of BHB stars will increase and our ability to measure the MW–LMC interaction will improve significantly.

Galaxy: evolution↗

Active rotor coning for a 25 MW downwind offshore wind turbine

A two-bladed downwind turbine system was upscaled from 13.2 MW to 25 MW by redesigning aerodynamics, structures, and controls. In particular, three 25-MW rotors were developed, and the final version is a fully redesigned model of the original rotor. Despite their radically large sizes, it was found that these 25-MW turbine rotors satisfy this limited set of structural design drivers at the rated condition and that larger blade lengths are possible with conewise load-alignment. In addition, flapwise morphing (varying the cone angle with a wind-speed schedule) was investigated to minimize mean and fluctuating blade root bending loads using steady inflow proxies for the maximum and lifetime damage equivalent load moments. Compared to the fixed coned rotor case, morphing can provide an Annual Energy Production (AEP) increase of 6%, and the maximum blade root flapwise bending moment increases 21% (still under the constraint, i.e., 10% of the ultimate moments) as a trade-off. The resulting series of 25-MW rotors can be a valuable baseline for further development and assessment of ultra-large-scale wind turbines.

17 WIND ENERGY↗

Enhancing membrane performance for CO 2 capture from flue gas with ultrahigh MW polyvinylamine

Membranes for post-combustion CO 2 capture are required to have a high CO 2 permeance due to the limited driving force. For facilitated transport membranes synthesized with polyvinylamine (PVAm), a defect-free selective layer of <200 nm is usually required to render sufficient permeance with high CO 2 /N 2 selectivity. In order to meet such a demand through the knife-coating process, the coating solution needs to have a high viscosity at a relatively low concentration to minimize its penetration into the substrate. The demand was met by synthesizing PVAm with an ultrahigh molecular weight (MW) via inverse emulsion polymerization (IEP) in this study. Compared to solution polymerization, IEP isolates the reaction in inverse micelles suspended in a continuous organic phase, which allows excellent dissipation of the heat generated by the reaction and reduces gel formation drastically. The polymerization parameters, including monomer concentration, initiator concentration, and reaction temperature, were investigated to obtain the optimal MW of PVAm for membrane performance. As compared to solution polymerization, IEP enhanced the MW of PVAm from 1.2 to 12.7 MDa, which minimized the penetration of the coating solution into the substrate and hence the extra mass transfer resistance. The effect of MW and degree of hydrolysis of PVAm on the membrane transport properties were studied. Furthermore, by employing PVAm with a MW of 12.7 MDa to strengthen the polymer matrix, the loading of piperazine glycinate in the membrane was increased up to 85 wt.%. In conclusion, the resultant membrane achieved a CO 2 permeance of 839 GPU and a CO 2 /N 2 selectivity of 161 at the typical flue gas temperature of 57°C.