Search NASA⌕ Search

SEARCH · Search NASA

Results for “MWD”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Multi-Wavelength Dielectrometer (MWD) Sensor For Planetary Subsurface Exploration

NASA's mission to Moon, Mars, and Beyond envisions landing of a light weight measurement platform on the planetary surface. The Multi-Wavelength Dielectrometer (MWD) on-board consists of essential electronics and metallic plates acting as electrodes attached to the body of such platform. An electric signal applied to one of the electrodes acting as a cathode sets up electric field pattern (in the soil medium) between the cathode and other electrodes acting as anodes. The electrodes are swept through multiple wavelengths (1Hz-1MHz) and the electric current drawn by the electrodes is measured at each frequency. The measured current whose amplitude and phase depend upon electrode spacing, dielectric constant of the subsurface soil, and the frequency is then used to estimate electrical properties of the soil. In this paper the MWD sensor that will measure the dielectric properties of Moon/Mars s soil is presented. A procedure to process the MWD measured data for extracting the soil properties is also described. Assuming the subsurface soil structure as multilayer strata having varying electric properties, an electric equivalent circuit of the multiple electrodes configuration placed on a multi-layer soil sample is obtained. The current drawn by the equivalent circuit from the low frequency signal generator is then calculated. By minimizing the difference between the model s estimated current and measured MWD data the electric properties of soil samples are extracted. Experimental and simulated results will be presented to validate the proposed procedure for extracting soil properties.

Deshpande, Manohar↗

A Comparison of Cilostazol and Pentoxifylline for Treating Intermittent Claudication

A randomized, double-blind, placebo-controlled, parallel-group, phase III multicenter trial was performed to evaluate the relative efficacy and safety of cilostazol and pentoxifylline. The study included 54 outpatient vascular clinics, including sites at Air Force, Veterans Affairs, tertiary care, and university hospitals in the United States. Of 922 consenting patients, 698 met the inclusion criteria, were randomized, and received treatment with either cilostazol 100 mg P0 twice a day, pentoxifylline 400 mg PO 3 times a day, or placebo. Treatment was double-dummy to ensure study blindness. Efficacy was primarily established by maximal walking distance (MWD), measured with constant-speed, variable-grade treadmill testing, assessed at baseline and at 4, 8, 12, 16, 20, and 24 weeks. Mean MWD of cilostazol-treated patients (n=227) was significantly improved at every visit compared with patients who received pentoxifylline (n=232) or placebo (n=239). After 24 weeks of cilostazol, mean MWD increased 53.9% (107.3 m) from baseline, and the effect had not plateaued. This was better (P < 0.001) than the 30.4% (64.4 m) MWD improvement with pentoxifylline. MWD improvement with pentoxifylline was similar (P = 0.82) to that of placebo (64.7 m). Deaths and serious adverse event rates were similar in each group. Common side effects included headache (27.8% with cilostazol, 11.2% with pentoxifylline, 11.7% with placebo), palpitations (17.2% with cilostazol, 2.2% with pentoxifylllne, 1.3% with placebo), and abnormal stools. Cilostazol was significantly better than pentoxifylline or placebo for increasing walking distances; pentoxifylline was no better than placebo.

Dawson, David L.↗

Determinations of molecular weight and molecular weight distribution of high polymers by the rheological properties

Several methods are reviewed by which the molecular weight (MW) and the molecular weight distribution (MWD) of polymeric material were determined from the rheological properties. A poly(arylene ether) polymer with six different molecular weights was used in this investigation. Experimentally measured MW and MWD were conducted by GPC/LALLS (gel permeation chromatography/low angle laser light scattering), and the rheological properties of the melts were measured by a Rheometric System Four rheometer. It was found that qualitative information of the MW and MWD of these polymers could be derived from the viscoelastic properties, with the methods proposed by Zeichner and Patel, and by Dormier et al., by shifting the master curves of the dynamic storage modulus, G', and the loss modulus, G'', along the frequency axis. Efforts were also made to calculate quantitative profiles of MW and MWD for these polymers from their rheological properties. The technique recently proposed by Wu was evaluated. It was found that satisfactory results could only be obtained for polymers with single modal distribution in the molecular weight.

Huang, J. Y.↗

Time-frequency representation of a highly nonstationary signal via the modified Wigner distribution

A new signal analysis technique called the modified Wigner distribution (MWD) is presented. The new signal processing tool has been very successful in determining time frequency representations of highly non-stationary multicomponent signals in both simulations and trials involving actual Space Shuttle Main Engine (SSME) high frequency data. The MWD departs from the classic Wigner distribution (WD) in that it effectively eliminates the cross coupling among positive frequency components in a multiple component signal. This attribute of the MWD, which prevents the generation of 'phantom' spectral peaks, will undoubtedly increase the utility of the WD for real world signal analysis applications which more often than not involve multicomponent signals.

Zoladz, T. F.↗

Development of a Telescope for Medium-Energy Gamma-Ray Astronomy

Since the launch of AGILE and FERMI, the scientific progress in high-energy (E(sub gamma) greater than approximately 200 MeV) gamma-ray science has been, and will continue to be dramatic. Both of these telescopes cover a broad energy range from approximately 20 MeV to greater than 10 GeV. However, neither instrument is optimized for observations below approximately 200 MeV where many astrophysical objects exhibit unique, transitory behavior, such as spectral breaks, bursts, and flares. Hence, while significant progress from current observations is expected, there will nonetheless remain a significant sensitivity gap in the medium-energy (approximately 0.1-200 MeV) regime; the lower end of this range remains largely unexplored whereas the upper end will allow comparison with FERMI data. Tapping into this unexplored regime requires significant improvements in sensitivity. A major emphasis of modern detector development, with the goal of providing significant improvements in sensitivity in the medium-energy regime, focuses on high-resolution electron tracking. The Three-Dimensional Track Imager (3-DTI) technology being developed at GSFC provides high resolution tracking of the electron-positron pair from gamma-ray interactions from 5 to 200 MeV. The 3-DTI consists of a time projection chamber (TPC) and 2-D cross-strip microwell detector (MWD). The low-density and homogeneous design of the 3-DTI, offers unprecedented sensitivity by providing angular resolution near the kinematic limit. Electron tracking also enables measurement of gamma-ray polarization, a new tool to study astrophysical phenomenon. We describe the design, fabrication, and performance of a 30x30x30 cubic centimeters 3-DTI detector prototype of a medium-energy gamma-ray telescope.

Hunter, Stanley D.↗

The Advanced Energetic Pair Telescope (AdEPT}: A Future Medium-Energy Gamma-Ray Balloon (and Explorer?) Mission

Gamma-ray astrophysics probes the highest energy, exotic phenomena in astrophysics. In the medium-energy regime, 0.1-200 MeV, many astrophysical objects exhibit unique and transitory behavior such as the transition from electron dominated to hadron dominated processes, spectral breaks, bursts, and flares. Medium-energy gamma-ray imaging however, continues to be a major challenge particularly because of high background, low effective area, and low source intensities. The sensitivity and angular resolution required to address these challenges requires a leap in technology. The Advance Energetic Pair Telescope (AdEPT) being developed at GSFC is designed to image gamma rays above 5 MeV via pair production with angular resolution of 1-10 deg. In addition AdEPT will, for the first time, provide high polarization sensitivity in this energy range. This performance is achieved by reducing the effective area in favor of enhanced angular resolution through the use of a low-density gaseous conversion medium. AdEPT is based on the Three-Dimensional Track Imager (3-DTI) technology that combines a large volume Negative Ion Time Projection Chamber (NITPC) with 2-D Micro-Well Detector (MWD) readout. I will review the major science topics addressable with medium-energy gamma-rays and discuss the current status of the AdEPT technology, a proposed balloon instrument, and the design of a future satellite mission.

Hunter, Stanley D.↗

Development of a Telescope for Medium-Energy Gamma-ray Astronomy

Since the launch of AGILE and FERMI, the scientific progress in high-energy (Eg greater than approximately 200 MeV) gamma-ray science has been, and will continue to be dramatic. Both of these telescopes cover a broad energy range from approximately 20 MeV to greater than 10 GeV. However, neither instrument is optimized for observations below approximately 200 MeV where many astrophysical objects exhibit unique, transitory behavior, such as spectral breaks, bursts, and flares. Hence, while significant progress from current observations is expected, there will nonetheless remain a significant sensitivity gap in the medium-energy (approximately 0.1-200 MeV) regime; the lower end of this range remains largely unexplored whereas the upper end will allow comparison with FERMI data. Tapping into this unexplored regime requires significant improvements in sensitivity. A major emphasis of modern detector development, with the goal of providing significant improvements in sensitivity in the medium-energy regime, focuses on high-resolution electron tracking. The Three-Dimensional Track Imager (3-DTI) technology being developed at GSFC provides high resolution tracking of the electron-positron pair from gamma-ray interactions from 5 to 200 MeV. The 3-DTI consists of a time projection chamber (TPC) and 2-D cross-strip microwell detector (MWD). The low-density and homogeneous design of the 3-DTI, offers unprecedented sensitivity by providing angular resolution near the kinematic limit. Electron tracking also enables measurement of gamma-ray polarization, a new tool to study astrophysical phenomenon. We describe the design, fabrication, and performance of a 30x30x30 cm3 3-DTI detector prototype of a medium-energy gamma-ray telescope.

Sunter, Stan↗

The Advanced Energetic Pair Telescope for Gamma-Ray Polarimetry

The Advanced Energetic Pair Telescope (AdEPT), a future NASA/GSFC MIDEX mission, is being developed to perform high-sensitivity medium-energy (5-200 MeV) astronomy and revolutionary gamma-ray polarization measurements. The enabling technology for AdEPT is the Three- Dimensional Track Imager (3-DTI), a large volume gaseous time projection chamber with 2- dimentional micro-well detector (MWD) readout. The low density and high spatial resolution of the 3-DTI allows AdEPT to achieve high angular resolution (~0.5 at 67.5 MeV) and, for the first time, exceptional gamma-ray polarization sensitivity. These capabilities enable a wide range of scientific discovery potential for AdEPT. The key science goals of the AdEPT mission include: 1) Explore fundamental processes of particle acceleration in active astrophysical objects, 2) Reveal the magnetic field configuration of the most energetic accelerators in the Universe, 3) Explore the origins and acceleration of cosmic rays and the Galactic MeV diffuse emission, 4) Search for dark matter in the Galactic center, and 5) Test relativity with polarization measurements. We report on the latest developments of the MWDs for the 3-DTI.

Hunter, Stanley D.↗