Search NASA⌕ Search

SEARCH · Search NASA

Results for “MYLAR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Use of a Mylar filter to eliminate vacuum ultraviolet pulse pileup in low-energy x-ray measurements

We describe a method to reduce vacuum ultraviolet (VUV) pulse pileup (PPU) in x-ray pulse-height Silicon Drift Detector (SDD) signals. An Amptek FAST SDD, with C1 (Si 3 N 4 ) window, measures bremsstrahlung emitted from PFRC-2 plasma to extract the electron temperature (T e ) and density (n e ). The C1 window has low transmissivity for photons with energy below 200 eV though will transmit some VUV and soft x-ray photons, which PFRC-2 plasmas abundantly emit. Multi-VUV-photon PPU contaminates the interpretation of x rays with energy > 100 eV, particularly in a low-energy exponential tail. The predicted low transmissivity of ~1 μm thick Mylar [polyethylene terephthalate (PET)] to photons of energy <100 eV led to the selection of Mylar as the candidate filter to reduce VUV PPU. Experiments were conducted on an x-ray tube with a graphite target and on a quasi-Maxwellian tenuous plasma (n e ~ 10 9 cm –3 ) with effective temperatures reaching 1500 eV. A Mylar filter thickness of 850 nm is consistent with the results. The Mylar-filter-equipped SDD was then used on the PFRC-2 plasma, showing a substantial reduction in the low-energy x-ray signal, supporting our hypothesis of the importance of VUV PPU. Here, we describe the modeling and experiments performed to characterize the effect of the Mylar filter on SDD measurements.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Dielectric Characterization of Mylar and The Effects of Doping Processes.

Mylar® polymer is a bi-axially oriented polyethylene terephthalate (PET) polymer film used widely as a dielectric, specifically in capacitors. The dielectric characteristics of Mylar have been well studied and documented over the years; however, many of the mechanisms responsible for dielectric breakdown and failure are not understood for modified versions of the material. Previous studies on Mylar confirm that factors such as temperature, humidity, and voltage ramp rates can also have a significant effect on the dielectric properties and measurement of the dielectric properties. This study seeks to determine how dielectric properties, including permittivity, dielectric loss, and breakdown strength, are affected by doping of the polymer. To do this, two types of Mylar films, virgin film and film doped with a small-molecule electron-acceptor, are tested. Both types of materials are tested under a variety of environmental and experimental conditions, including testing at elevated temperatures, varying relative humidity, and varying ramp rates in dielectric breakdown testing. Analysis of permittivity, dielectric loss, and breakdown strength will be presented comparing virgin and doped Mylar to gain insight into the effects of doping with electron-acceptor molecules on dielectric properties under these varying environmental and test conditions.

36 MATERIALS SCIENCE↗

Carbon/Ternary Alloy/Carbon Optical Stack on Mylar as an Optical Data Storage Medium to Potentially Replace Magnetic Tape

A novel write-once-read-many (WORM) optical stack on Mylar tape is proposed as a replacement for magnetic tape for archival data storage. This optical tape contains a cosputtered bismuth–tellurium–selenium (BTS) alloy as the write layer sandwiched between thin, protective films of reactively sputtered carbon. The composition and thickness of the BTS layer were confirmed by Rutherford Backscattering (RBS) and atomic force microscopy (AFM), respectively. The C/BTS/C stack on Mylar was written to/marked by 532 nm laser pulses. Under the same conditions, control Mylar films without the optical stack were unaffected. Marks, which showed craters/movement of the write material, were characterized by optical microscopy and AFM. The threshold laser powers for making marks on C/BTS/C stacks with different thicknesses were explored. Higher quality marks were made with a 60× objective compared to a 40× objective in our marking apparatus. Finally, the laser writing process was simulated with COMSOL.

Environmental Molecular Sciences Laboratory↗

A Versatile System for High-Throughput In Situ X-ray Screening and Data Collection of Soluble and Membrane-Protein Crystals

In recent years, in situ data collection has been a major focus of progress in protein crystallography. Here, we introduce the Mylar in situ method using Mylar-based sandwich plates that are inexpensive, easy to make and handle, and show significantly less background scattering than other setups. A variety of cognate holders for patches of Mylar in situ sandwich films corresponding to one or more wells makes the method robust and versatile, allows for storage and shipping of entire wells, and enables automated crystal imaging, screening, and goniometerbased X-ray diffraction data-collection at room temperature and under cryogenic conditions for soluble and membrane-protein crystals grown in or transferred to these plates. We validated the Mylar in situ method using crystals of the water-soluble proteins hen egg-white lysozyme and sperm whale myoglobin as well as the 7-transmembrane protein bacteriorhodopsin from Haloquadratum walsbyi. In conjunction with current developments at synchrotrons, this approach promises high-resolution structural studies of membrane proteins to become faster and more routine.

automation↗

High-throughput in situ X-ray screening of and data collection from protein crystals at room temperature and under cryogenic conditions

Protein crystallography has significantly advanced in recent years, with in situ data collection, in which crystals are placed in the X-ray beam within their growth medium, being a major point of focus. In situ methods eliminate the need to harvest crystals, a previously unavoidable drawback, particularly for often small membrane-protein crystals. Here, we present a protocol for the high-throughput in situ X-ray screening of and data collection from soluble and membrane-protein crystals at room temperature (20-25 degrees C) and under cryogenic conditions. The Mylar in situ method uses Mylar-based film sandwich plates that are inexpensive, easy to make, and compatible with automated imaging, and that show very low background scattering. They support crystallization in microbatch and vapor-diffusion modes, as well as in lipidic cubic phases (LCPs). A set of 3D-printed holders for differently sized patches of Mylar sandwich films makes the method robust and versatile, allows for storage and shipping of crystals, and enables automated mounting at synchrotrons, as well as goniometer-based screening and data collection. The protocol covers preparation of in situ plates and setup of crystallization trials; 3D printing and assembly of holders; opening of plates, isolation of film patches containing crystals, and loading them onto holders; basic screening and data-collection guidelines; and unloading of holders, as well as reuse and recycling of them. In situ plates are prepared and assembled in 1 h; holders are 3D-printed and assembled in <= 90 min; and an in situ plate is opened, and a film patch containing crystals is isolated and loaded onto a holder in 5 min.

36 MATERIALS SCIENCE↗

T-1042: Muon g-2 Straw Tracker

The new g-2 experiment is being constructed to improve on the current value measured at Brookhaven. One of the factors contributing to the improved understanding of systematic errors is a straw chamber that sits in the vacuum, close to the muon beam. These chambers can be used for a parasitic Electric dipole moment measurement, improved understanding of the beam dynamics and will improve the pile up library for the calorimeter. The chambers being built will consist of doublet U-V layers (with 15° between layers). The straws are made of wound mylar. One layer consists of 500 angstroms of aluminum on top of the mylar (the outside) and the other layer has 500 angstroms aluminum plus 200 angstroms of gold on the mylar. The two strips are wound together to make a straw. The straws will have a 25 micron gold plated tungsten wire in the middle at high voltage (~1400V) as the sense wire. A gas consisting of 80-20 Ar-C0 2 will be flowed through the straws. This will be a 32 channel prototype consisting of straws that are 9cm long.

Rominsky, Mandy↗

INS Nuclear Material Accounting and Control Instructional Video Materials- FY 25 Guides

This training video provides an essential guide to understanding and utilizing Tamper Indicating Devices (TIDs), with a specific focus on a common Mylar (Adhesive) variety during the application process. TIDs are a critical part of nuclear security, used to detect unauthorized access to sensitive materials or facilities. The Mylar (adhesive) TID employes a tamper-evident film integrated into the TID that visually indicates any tampering attempts. This video will explain how an example Mylar (adhesive) TID works, demonstrate proper installation techniques, and highlight how to interpret its indicators to ensure the security of nuclear materials.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

A new method for evaluating the effectiveness of plastic packaging against radon penetration

In this paper, we describe a new method to evaluate radon barriers which is unique in that it gauges not only the intrinsic resistance to radon penetration of a plastic film but also the integrity of bags fabricated from the film and sealed following some protocol, and it employs gamma spectroscopy rather than alpha spectroscopy. We report the results of sealed bags fabricated from polypropylene, Nylon, Mylar, metallized Mylar, FEP, and PFA. Evaluation of the fluoropolymers FEP and PFA as radon barriers are the first such measurements.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

SU-F-T-424: Mitigation of Increased Surface Dose When Treating Through A Carbon Fiber Couch Top

Purpose: To study the effect of the Varian carbon fiber couch top on surface dose for patients being treated using single PA beams in the supine position and to identify simple methods for surface dose reduction. Methods: Measurements of surface dose were obtained in Solid Water phantoms using both a parallel plate ionization chamber (PTW Advanced Markus) and EBT2 Radiochromic films for both 6 and 10MV photons. All measurements were referenced to a depth considered a typical for PA Spine fields. Techniques used to reduce the surface dose included introducing an air standoff using Styrofoam sheets to suspend the phantom surface above the couch top and by adding a thin high Z scattering foil on the table surface. Surface doses were evaluated for typical field sizes, standoff heights, and various scattering materials. Comparisons were made to the surface dose obtainable when treating through a Varian Mylar covered tennis racket style couch top. Results: Dependence on typical spine field sizes was relatively minor. Dependence on air gap was much more significant. Surface doses decreased exponentially with increases in air standoff distance. Surface doses were reduced by approximately 50% for an air gap of 10cm and 40% for a 15cm air gap. Surface doses were reduced by an additional 15% by the addition of a 1mm Tin scattering foil. Conclusion: Using simple techniques, it is possible to reduce the surface dose when treating single PA fields through the Varian carbon fiber couch top. Surface doses can be reduced to levels observed when treating though transparent Mylar tops by adding about 15 cm of air gap. Further reductions are possible by adding thin scattering foils, such as Tin or Lead, on the couch surface. This is a low cost approach to reduce surface dose when using the Varian carbon fiber couch top.

07 ISOTOPE AND RADIATION SOURCES↗

Analyzing data from a PDV microphone

Photon Doppler Velocimetry (PDV) is used at Los Alamos National Laboratory to measure extremely fast velocities (on the order of 0.01 - 5 km/s) of projectiles during material testing procedures. This kind of testing is extremely important to understand how materials behave in extreme conditions (such as in nuclear explosions). PDV data is created by summing an incident beam with a Doppler shifted reflection, forming a beat frequency. The beat frequency is directly proportional to the velocity of the reflecting surface. We explored a new way of using PDV: measuring slow velocities (less than 1 m/s). The principle method we used was to measure vibrations in a Mylar sheet due to incident sound waves. I analyzed these files using both my own coding as well as a program designed at NSTec for this purpose. Analysis included performing Fourier Transforms, extracting velocity as a function of time, and playing the velocity function through a speaker to recreate the initial sound. We were able to create a successful microphone, though playback quality was poor. The limiting factor was the low velocity of the Mylar sheet, which was about 0.2 m/s. Other methods are now being explored to extract velocity data in a more efficient manner. During this project I gained extensive experience in programming, data analysis, problem solving, and communication. I learned that one must be creative in order to solve complex problems, approaching them from various angles. I also gained a lot of practice working on a team, which consisted of a high school student, another college intern, and our mentor.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Design, characterization, and fabrication of solar-retroreflective cool-wall materials

Raising urban albedo increases the fraction of incident sunlight returned to outer space, cooling cities and their buildings. We evaluated the angular distribution of solar radiation incident on exterior walls in 17 U S. climates to develop performance parameters for solar-retroreflective walls, then applied first-principle physics and ray-tracing simulations to explore designs. Our analysis indicates that retroreflective walls must function at large incidence angles to reflect a substantial portion of summer sunlight, and that this will be difficult to attain with materials that rely on total internal reflection. Gonio-spectrophotometer measurements of the solar spectral bi-directional reflectivity of a bicycle reflector showed little to no retroreflection at large incidence angles. Visual comparisons of retroreflection to specular first-surface reflection for four different retroreflective safety films using violet and green lasers suggest their retroreflection to be no greater than 0.09 at incidence angles up to 45°, and no greater than 0.30 at incidence angles of up to 70°. Attempts to produce a two-surface retroreflector with orthogonal mirror grooves by cutting and polishing an aluminum block indicate that residual surface roughness impedes retroreflection. Ongoing efforts focus on forming orthogonal surfaces with aluminized Mylar film, a material with very high specular reflectance across the solar spectrum. We investigated (1) folding or stamping a free film; (2) adhering the film to a pre-shaped substrate; or (3) attaching the film to a flat ductile substrate, then shaping. The latter two methods were more successful but yielded imperfect right angles.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Multi-parametric approach towards the assessment of radon and thoron progeny exposures

Conventionally, the dosimetry is carried out using radon and thoron gas concentration measurements and doses have been assigned using assumed equilibrium factors for the progeny species, which is inadequate pertaining to the variations in equilibrium factors and possibly due to significant thoron. In fact, since the true exposures depend upon the intricate mechanisms of progeny deposition in the lung, therefore an integrated approach for the assessment of progeny is essential. In this context, the recently developed deposition based progeny concentration measurement techniques (DTPS: Direct Thoron progeny sensors and DRPS: Direct Radon progeny sensors) appear to be best suited for radiological risk assessments both among occupational workers and general study populations. DTPS and DRPS consist of aluminized mylar mounted LR115 type passive detectors, which essentially detects the alpha particles emitted from the deposited progeny atoms on the detector surface. It gives direct measure of progeny activity concentrations in air. DTPS has a lower limit of detection limit of 0.1 Bq/m{sup 3} whereas that for DRPS is 1 Bq/m{sup 3}, hence are perfectly suitable for indoor environments. These DTPS and DRPS can be capped with 200-mesh type wire-screen to measure the coarse fraction of the progeny concentration and the corresponding coarse fraction deposition velocities as well as the time integrated fine fraction. DTPS and DRPS can also be lodged in an integrated sampler wherein the wire-mesh and filter-paper are arranged in an array in flow-mode, to measure the fine and coarse fraction concentration separately and simultaneously. The details are further discussed in the paper.

61 RADIATION PROTECTION AND DOSIMETRY↗

Atmospheric pressure dielectric barrier discharges for sterilization and surface treatment

Atmospheric pressure non-thermal dielectric barrier discharges can be generated in different configurations for different applications. For sterilization, a parallel-plate electrode configuration with glass dielectric that discharges in air was used. Gram-negative bacteria (Escherichia coli and Salmonella enteritidis) and Gram-positive bacteria (Bacillus cereus) were successfully inactivated using sinusoidal high voltage of ∼15 kVp-p at 8.5 kHz. In the surface treatment, a hemisphere and disc electrode arrangement that allowed a plasma jet to be extruded under controlled nitrogen gas flow (at 9.2 kHz, 20 kVp-p) was applied to enhance the wettability of PET (Mylar) film.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗