Search NASA⌕ Search

SEARCH · Search NASA

Results for “Magnetic Resonance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Challenges in Pulsed-Field Gradient Nuclear Magnetic Resonance on Magnetically Heterogeneous Interfaces: Sequence and Field-Dependent Apparent Diffusion Coefficients

It is well known that the internal gradient (gi) that exists within pores haunts the diffusion coefficient (D) as measured by the pulsed-field gradient (PFG) nuclear magnetic resonance (NMR). Several PFG-NMR methods developed to determine an accurate D were not successful. Then, the steady-state diffusion coefficient (Dapp,8) for the cation [C4mim]+ of [C4mim][Tf2N]; [1-butyl-3-methylimidazolium][bis(trifluoromethylsulfonyl)imde] ionic liquid confined in ordered mesoporous carbon (OMC) were determined by comparing Dapp,8 obtained from 1H PFG-NMR performed with three different stimulated echo sequences: STE, APFG, and MPFG under the two external magnetic field strength, B0 = 9.4 and 14.1 Tesla. The measured Dapp,8 which is an order of magnitude smaller than D of bulk [C4mim][Tf2N], is in good agreement between APFG and MPFG both in B0 = 9.4 and 14.1 Tesla. However, the strong gi artifact, which caused apparent diffusion coefficient (Dapp) depending strongly and weakly on B0 and temperature, respectively, in diffusion-time dependent Dapp, Dapp(?) obtained from a sequence with monopolar gradients (STE) was suppressed by using sequences employing bipolar gradients (APFG and MPFG) in the region of steady-state diffusion. But incompletely suppressed gi artifact resulting in the different behaviors of the early part of Dapp(?) between the sequences leads a ˜ 0.6 and 0.9 in MPFG and APFG, respectively, in the relationship between mean squared displacement and diffusion time: = 2Dta, where a = 0.5 and 1 for 1-dimensional single file diffusion and 3-dimensional bulk diffusion, respectively. The above observations clearly show that the diffusion behavior of ions/molecules within the pores and pore structure, such as the surface-to-volume ratio? (D?_app (?)=D_0 [1-4/(9vp) S/V v(D_0 ?)]) and tortuosity (T = D0/Dapp,8), are possible to be misunderstood, especially in the systems with a non-negligible gi. This work demonstrates that it may be necessary to test several PFG sequences under multiple external magnetic fields for the correct determination of the diffusion behavior of ions/molecules in the pores with a larger internal gradient, gi.

Han, Kee Sung↗

Physiological cross-sectional area of human leg muscles based on magnetic resonance imaging

Magnetic resonance imaging techniques were used to determine the physiological cross-sectional areas (PCSAs) of the major muscles or muscle groups of the lower leg. For 12 healthy subjects, the boundaries of each muscle or muscle group were digitized from images taken at 1-cm intervals along the length of the leg. Muscle volumes were calculated from the summation of each anatomical CSA (ACSA) and the distance between each section. Muscle length was determined as the distance between the most proximal and distal images in which the muscle was visible. The PCSA of each muscle was calculated as muscle volume times the cosine of the angle of fiber pinnation divided by fiber length, where published fiber length:muscle length ratios were used to estimate fiber lengths. The mean volumes of the major plantarflexors were 489, 245, and 140 cm3 for the soleus and medial (MG) and lateral (LG) heads of the gastrocnemius. The mean PCSA of the soleus was 230 cm2, about three and eight times larger than the MG (68 cm2) and LG (28 cm2), respectively. These PCSA values were eight (soleus), four (MG), and three (LG) times larger than their respective maximum ACSA. The major dorsiflexor, the tibialis anterior (TA), had a muscle volume of 143 cm2, a PCSA of 19 cm2, and an ACSA of 9 cm2. With the exception of the soleus, the mean fiber length of all subjects was closely related to muscle volume across muscles. The soleus fibers were unusually short relative to the muscle volume, thus potentiating its force potential.(ABSTRACT TRUNCATED AT 250 WORDS).

NASA Discipline Musculoskeletal↗

Tunable Magnetic Resonance in Microwave Spintronics Devices

Magnetic resonance is one of the key properties of magnetic materials for the application of microwave spintronics devices. The conventional method for tuning magnetic resonance is to use an electromagnet, which provides very limited tuning range. Hence, the quest for enhancing the magnetic resonance tuning range without using an electromagnet has attracted tremendous attention. In this paper, we exploit the huge exchange coupling field between magnetic interlayers, which is on the order of 4000 Oe and also the high frequency modes of coupled oscillators to enhance the tuning range. Furthermore, we demonstrate a new scheme to control the magnetic resonance frequency. Moreover, we report a shift in the magnetic resonance frequency as high as 20 GHz in CoFe-based tunable microwave spintronics devices, which is 10X higher than conventional methods.

Microwave Detectors↗

Tunable Magnetic Resonance in Microwave Spintronics Devices

Magnetic resonance is one of the key properties of magnetic materials for the application of microwave spintronics devices. The conventional method for tuning magnetic resonance is to use an electromagnet, which provides very limited tuning range. Hence, the quest for enhancing the magnetic resonance tuning range without using an electromagnet has attracted tremendous attention. In this paper, we exploit the huge exchange coupling field between magnetic interlayers, which is on the order of 4000 Oe and also the high frequency modes of coupled oscillators to enhance the tuning range. Furthermore, we demonstrate a new scheme to control the magnetic resonance frequency. Moreover, we report a shift in the magnetic resonance frequency as high as 20 GHz in CoFe based tunable microwave spintronics devices, which is 10X higher than conventional methods.

Microwave Detectors↗

MEMS-Based Force-Detected Nuclear Magnetic Resonance (FDNMR) Spectrometer

Nuclear Magnetic Resonance (NMR) spectroscopy allows assignment of molecular structure by acquiring the energy spectrum of nuclear spins in a molecule, and by interpreting the symmetry and positions of resonance lines in the spectrum. As such, NMR has become one of the most versatile and ubiquitous spectroscopic methods. Despite these tremendous successes, NMR experiments suffer from inherent low sensitivity due to the relatively low energy of photons in the radio frequency (rt) region of the electromagnetic spectrum. Here, we describe a high-resolution spectroscopy in samples with diameters in the micron range and below. We have reported design and fabrication of force-detected nuclear magnetic resonance (FDNMR).

force detected nuclear magnetic resonance (FDNMR)↗

Axion magnetic resonance: A novel enhancement in axion-photon conversion

We identify a new resonance, axion magnetic resonance, that can greatly enhance the conversion rate between axions and photons. A series of axion search experiments rely on converting them into photons inside a constant magnetic field background. A common bottleneck of such experiments is the conversion amplitude being suppressed by the axion mass when m a ≳ 10 − 4 eV . We point out that a spatial or temporal variation in the magnetic field can cancel the difference between the photon dispersion relation and that of the axion, hence greatly enhancing the conversion probability. We demonstrate that the enhancement can be achieved by both a helical magnetic field profile and a harmonic oscillation of the magnitude. Our approach can extend the projected ALPS II reach in the axion-photon coupling ( g a γ ) by two orders of magnitude at m a = 10 − 3 eV with moderate assumptions (see .) Published by the American Physical Society 2024

79 ASTRONOMY AND ASTROPHYSICS↗

Imaging of the hip joint. Computed tomography versus magnetic resonance imaging

The authors reviewed the applications and limitations of computed tomography (CT) and magnetic resonance (MR) imaging in the assessment of the most common hip disorders. Magnetic resonance imaging is the most sensitive technique in detecting osteonecrosis of the femoral head. Magnetic resonance reflects the histologic changes associated with osteonecrosis very well, which may ultimately help to improve staging. Computed tomography can more accurately identify subchondral fractures than MR imaging and thus remains important for staging. In congenital dysplasia of the hip, the position of the nonossified femoral head in children less than six months of age can only be inferred by indirect signs on CT. Magnetic resonance imaging demonstrates the cartilaginous femoral head directly without ionizing radiation. Computed tomography remains the imaging modality of choice for evaluating fractures of the hip joint. In some patients, MR imaging demonstrates the fracture even when it is not apparent on radiography. In neoplasm, CT provides better assessment of calcification, ossification, and periosteal reaction than MR imaging. Magnetic resonance imaging, however, represents the most accurate imaging modality for evaluating intramedullary and soft-tissue extent of the tumor and identifying involvement of neurovascular bundles. Magnetic resonance imaging can also be used to monitor response to chemotherapy. In osteoarthrosis and rheumatoid arthritis of the hip, both CT and MR provide more detailed assessment of the severity of disease than conventional radiography because of their tomographic nature. Magnetic resonance imaging is unique in evaluating cartilage degeneration and loss, and in demonstrating soft-tissue alterations such as inflammatory synovial proliferation.

Review↗

Identification of the Ga interstitial in Al(x)Ga(1-x)As by optically detected magnetic resonance

A new optically detected magnetic resonance spectrum in Al(x)Ga(1-x)As is reported and assigned to native Ga interstitials. Luminescence-quenching signals were observed over the energy region from 0.75 to 1.1 eV. The optically detected magnetic resonance is nearly isotropic, with spin-Hamiltonian parameters g = 2.025 + or - 0.006, central hyperfine splitting A(Ga-69) = 0.050 + or - 0.001/cm, and A(Ga-71) = 0.064 + or - 0.001/cm for H near the 001 line. The strong hyperfine coupling denotes an electronic state of A1 symmetry, which current theories predict for the Ga interstitial but not the Ga antisite. The slight anisotropy probably indicates that the Ga(i) is paired with a second, unknown defect.

Kennedy, T. A.↗

Nuclear magnetic resonance properties of lunar samples.

Nuclear magnetic resonance spectra of Na-23, Al-27, and P-31 in fines samples 10084,60 and 14163,168 and in crystalline rock samples 12021,55 and 14321,166, have been recorded over a range of frequencies up to 20 MHz. A shift in the field at which maximum absorption occurs for all of the spectra relative to the field at which maximum absorption occurs for terrestrial analogues is attributed to a sample-dependent magnetic field at the Na, Al, and P sites opposing the laboratory field. The magnitude of these fields internal to the samples is sample dependent and varies from 5 to 10 G. These fields do not correlate with the iron content of the samples. However, the presence of single-domain particles of iron distributed throughout the plagioclase fraction that contains the principal fraction of Na and Al is inferred from electron magnetic resonance spectra shapes.

Kline, D.↗

Precipitation of gadolinium from magnetic resonance imaging contrast agents may be the Brass tacks of toxicity

The formation of gadolinium-rich nanoparticles in multiple tissues from intravenous magnetic resonance imaging contrast agents may be the initial step in rare earth metallosis. The mechanism of gadolinium-induced diseases is poorly understood, as is how these characteristic nanoparticles are formed. Gadolinium deposition has been observed with all magnetic resonance imaging contrast agent brands. Aside from endogenous metals and acidic conditions, little attention has been paid to the role of the biological milieu in the degradation of magnetic resonance imaging contrast agents into nanoparticles. Herein, we describe the decomposition of the commercial magnetic resonance imaging contrast agents Omniscan and Dotarem in the presence of oxalic acid, a well-known endogenous compound. Omniscan dechelated rapidly and preluded measurement by the means available, while Dotarem underwent a two-step decomposition process. The decomposition of both magnetic resonance imaging contrast agents by oxalic acid formed gadolinium oxalate (Gd 2 [C 2 O 4 ] 3 , Gd 2 Ox 3 ). Furthermore, both observed steps of the Dotarem reaction involved the associative addition of oxalic acid. Adding protein (bovine serum albumin) increased the rate of dechelation. Displacement reactions could occur at lysosomal pH. Through these studies, we have demonstrated that magnetic resonance imaging contrast agents can be dissociated by endogenous molecules, thus illustrating a metric by which gadolinium-based contrast agents (GBCAs) might be destabilized in vivo.

Gadodiamide↗

Impact of Resonant Magnetic Perturbations on the Toroidal Location of the Runaway Electron Final Loss Strike Point

It is demonstrated that the peak toroidal impact phase of the post-disruption runaway electrons (REs) can be varied shot-to-shot by means of applied static non-axisymmetric (3D) magnetic fields, or resonant magnetic perturbations (RMPs). In the experiments, high-current (500 kA), purged RE plateaus (i.e. low impurity post-disruption plasmas with current carried completely by REs) were terminated on the DIII-D tokamak center post (CP). The global toroidal impact peak of the REs appears to be dominantly set by the toroidal phase of a wall-locked tearing mode, typically (m/n) = (2/1), but sometimes (m/n) = (3/2). In the absence of external RMP, the locked mode reliably locks close to a preferred toroidal phase Φ ≃ 75◦ probably set by intrinsic error fields. With applied RMP, the locked mode and RE impact phase is pushed to a new location. When the tearing mode is (m/n) = (2/1), the phase is well controlled and tracks the applied RMP phase, but in the case of an (m/n) = (3/2) tearing mode, the new phase location is not well controlled. These results could have application in ITER and other fusion power plant (FPP) - sized tokamaks as a method for spreading disruption first wall damage from REs

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Roadmap on nanoscale magnetic resonance imaging

Abstract The field of nanoscale magnetic resonance imaging (NanoMRI) was started 30 years ago. It was motivated by the desire to image single molecules and molecular assemblies, such as proteins and virus particles, with near-atomic spatial resolution and on a length scale of 100 nm. Over the years, the NanoMRI field has also expanded to include the goal of useful high-resolution nuclear magnetic resonance (NMR) spectroscopy of molecules under ambient conditions, including samples up to the micron-scale. The realization of these goals requires the development of spin detection techniques that are many orders of magnitude more sensitive than conventional NMR and MRI, capable of detecting and controlling nanoscale ensembles of spins. Over the years, a number of different technical approaches to NanoMRI have emerged, each possessing a distinct set of capabilities for basic and applied areas of science. The goal of this roadmap article is to report the current state of the art in NanoMRI technologies, outline the areas where they are poised to have impact, identify the challenges that lie ahead, and propose methods to meet these challenges. This roadmap also shows how developments in NanoMRI techniques can lead to breakthroughs in emerging quantum science and technology applications.

Budakian, Raffi↗

Reducing Field Distortion in Magnetic Resonance Imaging

A concept for a magnetic resonance imaging (MRI) system that would utilize a relatively weak magnetic field provides for several design features that differ significantly from the corresponding features of conventional MRI systems. Notable among these features are a magnetic-field configuration that reduces (relative to the conventional configuration) distortion and blurring of the image, the use of a superconducting quantum interference device (SQUID) magnetometer as the detector, and an imaging procedure suited for the unconventional field configuration and sensor. In a typical application of MRI, a radio-frequency pulse is used to excite precession of the magnetic moments of protons in an applied magnetic field, and the decaying precession is detected for a short time following the pulse. The precession occurs at a resonance frequency proportional to the strengths of the magnetic field and the proton magnetic moment. The magnetic field is configured to vary with position in a known way; hence, by virtue of the aforesaid proportionality, the resonance frequency varies with position in a known way. In other words, position is encoded as resonance frequency. MRI using magnetic fields weaker than those of conventional MRI offers several advantages, including cheaper and smaller equipment, greater compatibility with metallic objects, and higher image quality because of low susceptibility distortion and enhanced spin-lattice-relaxation- time contrast. SQUID MRI is being developed into a practical MRI method for applied magnetic flux densities of the order of only 100 T

Eom, Byeong Ho↗

Neural Network Analysis of Nuclear Magnetic Resonance and Infrared Spectra

Nuclear magnetic resonance (NMR) spectroscopy and infrared (IR) spectroscopy are powerful chemical characterization techniques with broad general usage. However, the manual evaluation of the resulting spectra is time-consuming and requires significant expertise, preventing insights from being used in real-time applications. With recent advances in computation and artificial intelligence (AI), new tools are available for automating spectral interpretation. In this work, machine learning (ML) algorithms using 1-dimensional convolutional neural networks (CNNs) were applied to identify common functional groups from spectral information. Raw spectra were collected virtually from the Human Metabolome Database (HMDB) and National Institute of Standards and Technology (NIST) Chemistry WebBook and processed into a suitable standard. Algorithm design was tailored to best fit the nature of the problem, with built-in flexibility to accommodate relevant parameters beyond the raw spectral input, specifically solvent identity and magnetic frequency for NMR. The predictive capability of the algorithm in identifying functional groups is displayed in several examples. This methodology has been compiled into a code repository and could easily be modified to adapt alternative data sources, including other spectrum types. To mitigate overfitting, a common problem in mathematical modeling where overfamiliarity with training data produces trends that are not representative of the general data, a novel metric was developed, referred to as Accufit. Accufit includes a parameter that penalizes substantial differences in the training accuracy and the accuracy of an independent validation set. Examples are presented showing the effectiveness of Accufit in maintaining the model’s predictive capability while controlling the overfitting when used as a custom metric for hyperparameter tuning.

Sturgill, James↗

Magnetic phases in lunar material and their electron magnetic resonance spectra - Apollo 14.

Electron magnetic resonance spectra of soil samples 14163,68, 14148,31, 14149,47, 14156,31, and 14003,60, and of fragmental rocks 14301,66, 14303,42, 14310,68, 14311,36, 14318,36, and 14321,166 have been recorded at 9 and 35 GHz at 300 K and at 9 GHz at 130 K. One spectral component, the characteristic ferromagnetic resonance, of all the soil samples is 50 to 1000 times more intense than any other component in the soils or in the spectra of the rocks. The intensity of this component in Apollo 11, Apollo 12, and Apollo 14 soils varies only within one order of magnitude. It varies with depth below lunar surface but is not correlated with depth. The intensity does not have any correlation with the fraction of glassy particles nor with the fraction of anorthositic particles.

Weeks, R. A.↗