Search NASA⌕ Search

SEARCH · Search NASA

Results for “Magnetic Resonance Spectroscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

A versatile pulse programmer for pulsed nuclear magnetic resonance spectroscopy.

A digital pulse programmer producing the standard pulse sequences required for pulsed nuclear magnetic resonance spectroscopy is described. In addition, a 'saturation burst' sequence, useful in the measurement of long relaxation times in solids, is provided. Both positive and negative 4 V trigger pulses are produced that are fully synchronous with a crystal-controlled time base, and the pulse programmer may be phase-locked with a maximum pulse jitter of 3 ns to the oscillator of a coherent pulse spectrometer. Medium speed TTL integrated circuits are used throughout.

Tarr, C. E.↗

P-31 Magnetic Resonance Spectroscopy (MRS) of limb muscles during bedrest with exercise countermeasures

Nineteen volunteers in bed with head down tilt (-6 deg) for 1 month and doing or not exercise training while in bed (lido or ergometer) had their limb muscle studied by magnetic resonance spectroscopy. A protocol of repetitive exercise in the magnet was set and a wooden probe designed to support the limb and to allow exercise. Spectra were recorded continuously during the protocol. In each spectrum, inorganic phosphate, phosphocreatin, adenosin triphosphate, and pH were measured. All the subjects were studied before, after bedrest, and 6 weeks later. After 1 month, the lido group show no changes in the spectra of their leg muscles while the group doing no exercise or ergometer do. For the arms, a loss of muscle function is only seen in the group doing no exercise.

Berry, P.↗

Infrared and far-infrared laser magnetic resonance spectroscopy of the GeH radical - Determination of ground state parameters

The GeH radical has been detected in its ground 2 Pi state in the gas phase reaction of fluorine atoms with GeH4 by laser magnetic resonance techniques. Rotational transitions within both 2 Pi 1/2 and 2 Pi 3/2 manifolds have been observed at far-infrared wavelengths and rotational transitions between the two fine structure components have been detected at infrared wavelengths (10 microns). Signals have been observed for all five naturally occurring isotopes of germanium. Nuclear hyperfine structure for H-1 and Ge-73 has also been observed. The data for the dominant isotope (/Ge-74/H) have been fitted to within experimental error by an effective Hamiltonian to give a set of molecular parameters for the X 2 Pi state which is very nearly complete. In addition, the dipole moment of GeH in its ground state has been estimated from the relative intensities of electric and magnetic dipole transitions in the 10 micron spectrum to be 1.24(+ or - 0.10) D.

Brown, J. M.↗

Carbon-13 NMR studies of salt shock-induced carbohydrate turnover in the marine cyanobacterium Agmenellum quadruplicatum

Carbon turnover in response to abrupt changes in salinity, including the mobilization of glycogen for use in osmoregulation was studied with pulse-chase strategies utilizing nuclear magnetic resonance (NMR)-silent and NMR-detectable 12C and 13C isotopes, respectively. Growth of Agmenellum quadruplicatum in 30%-enriched 13C bicarbonate provided sufficient NMR-detectability of intracellular organic osmoregulants for these studies. A comparison of NMR spectra of intact cells and their ethanol extracts showed that the intact cell data were suitable for quantitative work, and, when combined with ESR measurements of cell volumes, yielded intracellular glucosylglycerol concentrations without disrupting the cells. NMR pulse-chase experiments were used to show that 13C-enriched glycogen, which had previously been accumulated by the cells under nitrogen-limited growth at low salinities, could be utilized for the synthesis of glucosylglycerol when the cells were abruptly transferred to hypersaline media, but only in the light. It was also shown that the accumulation of glucosylglycerol in the light occurred on a time scale similar to that of cell doubling. Depletion of glucosylglycerol when cells abruptly transferred to lower salinities appeared to be rapid--the intracellular pool of this osmoregulant was decreased 2-fold within 2 hours of hypotonic shock.

NASA Discipline Life Support Systems↗

Eddy current correction in volume-localized MR spectroscopy

The quality of volume-localized magnetic resonance spectroscopy is affected by eddy currents caused by gradient switching. Eddy currents can be reduced with improved gradient systems; however, it has been suggested that the distortion due to eddy currents can be compensated for during postprocessing with a single-frequency reference signal. The authors propose modifying current techniques for acquiring the single-frequency reference signal by using relaxation weighting to reduce interference from components that cannot be eliminated by digital filtering alone. Additional sequences with T1 or T2 weighting for reference signal acquisition are shown to have the same eddy current characteristics as the original signal without relaxation weighting. The authors also studied a new eddy current correction method that does not require a single-frequency reference signal. This method uses two free induction decays (FIDs) collected from the same volume with two sequences with opposite gradients. Phase errors caused by eddy currents are opposite in these two FIDs and can be canceled completely by combining the FIDs. These methods were tested in a phantom. Eddy current distortions were corrected, allowing quantitative measurement of structures such as the -CH = CH- component, which is otherwise undetectable.

NASA Discipline Musculoskeletal↗

Thermal Studies of New Precursors to Indium-tin Oxides for Use as Sensor Materials in the Detection of NO(x)

Control of combustion product emissions in both sub and super-sonic jet engines can be facilitated by measurement of NO(x) levels with metal oxide sensors, In2O3, metal-doped SnO2, and SnO, (as well as other materials) show resistivity changes in the presence of NO(x), but often their sensitivity, stability, and selectivity are low. This study was designed to develop new synthetic pathways to precursors that produce high purity, two phase In2O3-SnO2. The precursors were formed by complexation of tin with any oxide ligands to give the ammonium salt (NH4). Thermal studies of these precursors were carried out by thermal gravimetry (TG) and differential scanning calorimetry (DSC). Further studies by Fourier transform infrared spectroscopy (FTIR) and nuclear magnetic resonance spectroscopy (NMR) were also conducted.

Goldsby, J. C.↗

A high-resolution Fourier Transform Spectrometer for planetary spectroscopy

The employment of a high-resolution Fourier Transform Spectrometer (FTS) is described for planetary and other astronomical spectroscopy in conjunction with the 88-inch telescope at Mauna Kea Observatory. The FTS system is designed for a broad range of uses, including double-beam laboratory spectroscopy, infrared gas chromatography, and nuclear magnetic resonance spectroscopy. The data system is well-suited to astronomical applications because of its great speed in acquiring and transforming data, and because of the enormous storage capability of the magnetic tape unit supplied with the system. The basic instrument is outlined 2nd some of the initial results from the first attempted use on the Mauna Kea 88-inch telescope are reported.

Cruikshank, D. P.↗

Teflon FEP Analyzed After Retrieval From the Hubble Space Telescope

During the Hubble Space Telescope (HST) Second Servicing Mission, 6.8 years after the telescope was deployed in low Earth orbit, degradation of unsupported Teflon FEP (DuPont; fluorinated ethylene propylene), used as the outer layer of the multilayer insulation (MLI) blankets, was evident as large cracks on the telescope light shield. A sample of the degraded outer layer (see the photograph) was retrieved during the second servicing mission and returned to Earth for ground testing and evaluation. Also retrieved was a Teflon FEP radiator surface from a cryogen vent cover that was exposed to the space environment on the aft bulkhead of the HST. NASA Goddard Space Flight Center directed the efforts of the Hubble Space Telescope MLI Failure Review Board, whose goals included determining the FEP degradation mechanisms. As part of the investigations into the degradation mechanisms, specimens retrieved from the first and second HST servicing missions, 3.6 and 6.8 years after launch, respectively, were characterized through exhaustive mechanical, optical, and chemical testing. Testing led by Goddard included scanning electron microscopy, optical microscopy, tensile testing, solar absorptance measurements, time-of-flight secondary ion mass spectroscopy (TOF-SIMS), Fourier transform infrared microscopy (m-FTIR), attenuated total reflectance infrared microscopy (ATR/FTIR), and x-ray diffraction (XRD). The NASA Lewis Research Center contributed significantly to the analysis of the retrieved HST materials by leading efforts and providing results of bend testing, surface microhardness measurements, x-ray photoelectron spectroscopy, solid-state nuclear magnetic resonance spectroscopy, and density measurements. Other testing was conducted by Nano Instruments, Inc., and the University of Akron.

Dever, Joyce A.↗

Metabolic myopathies

Metabolic myopathies are disorders of muscle energy production that result in skeletal muscle dysfunction. Cardiac and systemic metabolic dysfunction may coexist. Symptoms are often intermittent and provoked by exercise or changes in supply of lipid and carbohydrate fuels. Specific disorders of lipid and carbohydrate metabolism in muscle are reviewed. Evaluation often requires provocative exercise testing. These tests may include ischemic forearm exercise, aerobic cycle exercise, and 31P magnetic resonance spectroscopy with exercise.

Review↗

The Nature of Insoluble Organic Matter in Sutter’s Mill and Murchison Carbonaceous Chondrites: Testing the Effect of X-ray Computed Tomography (XCT) and Exploring Parent Body Organic Molecular Evolution

This study analyzed samples of the Murchison and Sutter’s Mill carbonaceous chondrite meteorites in support of the future analysis of samples returned from the asteroid (10155) Bennu by the OSIRIS-REx (Origins, Spectral Interpretation, Resource Identification, and Security–Regolith Explorer) mission. Focusing specifically on the insoluble organic matter (IOM), this study establishes that a total of 1.3 g of bulk sample from a single chondritic meteorite is sufficient to obtain a wide range of cosmochemical information, including light element analysis (H, C, and N), isotopic analysis (D/H, 13 C/ 12 C, and 15 N/ 14 N), and X-ray fluorescence spectroscopy for major elemental abundances. IOM isolated from the bulk meteorite samples was analyzed by light element and isotopic analysis as described above, 1 H and 13 C solid-state nuclear magnetic resonance spectroscopy, Raman spectroscopy, and complete noble gas analyses (abundances and isotopes). The samples studied included a pair from Murchison (CM2), one of which had been irradiated with high-energy X-rays in the course of computed tomographic imaging. No differences between the irradiated and non-irradiated Murchison samples were observed in the many different chemical and spectroscopic analyses, indicating that any X-ray–derived sample damage is below levels of detection. Elemental, isotopic, and molecular spectroscopic data derived from IOM isolated from the Sutter’s Mill sample reveals evidence that this meteorite falls into the class of heated CM chondrites.

planetary science↗

T2 vertebral bone marrow changes after space flight

Bone biopsies indicate that during immobilization bone marrow adipose tissue increases while the functional cellular fraction decreases. One objective of our Spacelab flight experiment was to determine, using in vivo volume-localized magnetic resonance spectroscopy (VLMRS), whether bone marrow composition was altered by space flight. Four crew members of a 17 day Spacelab mission participated in the experiment. The apparent cellular fraction and transverse relaxation time (T2) were determined twice before launch and at several times after flight. Immediately after flight, no significant change in the cellular fraction was found. However, the T2 of the cellular, but not the fat component increased following flight, although to a variable extent, in all crew members with a time course for return to baseline lasting several months. The T2 of seven control subjects showed no significant change. Although these observations may have several explanations, it is speculated that the observed T2 changes might reflect increased marrow osteoblastic activity during recovery from space flight.

NASA Experiment Number 284054↗