Search NASA⌕ Search

SEARCH · Search NASA

Results for “Magnetic calorimeters”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Development of Position-Sensitive Magnetic Calorimeters for X-Ray Astronomy

Metallic magnetic calorimeters (MMC) are one of the most promising devices to provide very high energy resolution needed for future astronomical x-ray spectroscopy. MMC detectors can be built to large detector arrays having thousands of pixels. Position-sensitive magnetic (PoSM) microcalorimeters consist of multiple absorbers thermally coupled to one magnetic micro calorimeter. Each absorber element has a different thermal coupling to the MMC, resulting in a distribution of different pulse shapes and enabling position discrimination between the absorber elements. PoSMs therefore achieve the large focal plane area with fewer number of readout channels without compromising spatial sampling. Excellent performance of PoSMs was achieved by optimizing the designs of key parameters such as the thermal conductance among the absorbers, magnetic sensor, and heat sink, as well as the absorber heat capacities. Micro fab ri - cation techniques were developed to construct four-absorber PoSMs, in which each absorber consists of a two-layer composite of bismuth and gold. The energy resolution (FWHM full width at half maximum) was measured to be better than 5 eV at 6 keV x-rays for all four absorbers. Position determination was demonstrated with pulse-shape discrimination, as well as with pulse rise time. X-ray microcalorimeters are usually designed to thermalize as quickly as possible to avoid degradation in energy resolution from position dependence to the pulse shapes. Each pixel consists of an absorber and a temperature sensor, both decoupled from the cold bath through a weak thermal link. Each pixel requires a separate readout channel; for instance, with a SQUID (superconducting quantum interference device). For future astronomy missions where thousands to millions of resolution elements are required, having an individual SQUID readout channel for each pixel becomes difficult. One route to attaining these goals is a position-sensitive detector in which a large continuous or pixilated array of x-ray absorbers shares fewer numbers of temperature sensors. A means of discriminating the signals from different absorber positions, however, needs to be built into the device for each sensor. The design concept for the device is such that the shape of the temperature pulse with time depends on the location of the absorber. This inherent position sensitivity of the signal is then analyzed to determine the location of the event precisely, effectively yielding one device with many sub-pixels. With such devices, the total number of electronic channels required to read out a given number of pixels is significantly reduced. PoSMs were developed that consist of four discrete absorbers connected to a single magnetic sensor. The design concept can be extended to more than four absorbers per sensor. The thermal conductance between the sensor and each absorber is different by design and consequently, the pulse shapes are different depending upon which absorber the xrays are received, allowing position discrimination. A magnetic sensor was used in which a paramagnetic Au:Er temperature-sensitive material is located in a weak magnetic field. Deposition of energy from an x-ray photon causes an increase in temperature, which leads to a change of magnetization of the paramagnetic sensor, which is subsequently read out using a low noise dc-SQUID. The PoSM microcalorimeters are fully microfabricated: the Au:Er sensor is located above the meander, with a thin insulation gap in between. For this position-sensitive device, four electroplated absorbers are thermally linked to the sensor via heat links of different thermal conductance. One pixel is identical to that of a single-pixel design, consisting of an overhanging absorber fabricated directly on top of the sensor. It is therefore very strongly thermally coupled to it. The three other absorbers are supported directly on a silicon-nitride membrane. These absorbers are thermally coupled to the sensor via Ti (5 nm)/Au250 nm) metal links. The strength of the links is parameterized by the number of gold squares making up the link. For detector performance, experimentally different pulse-shapes were demonstrated with 6 keV x-rays, which clearly show different rise times for different absorber positions. For energy resolution measurement, the PoSM was operated at 32 mK with an applied field that was generated using a persistent current of 50 mA. Over the four pixels, energy resolution ranges from 4.4 to 4.7 eV were demonstrated.

Bandler, SImon↗

Position-Sensitive Magnetic Calorimeters for Lynx

We describe the performance of position-sensitive metallic magnetic calorimeter X-ray detectors for potential future astrophysics missions, such as Lynx. The motivation behind this is to achieve a large focal plane area by increasing the number of pixels compared to the number of readout channels (called hydra). The detector consists of a 5×5 array of gold absorbers thermally coupled to a paramagnetic sensor. Since each absorber has a different thermal link to the sensor, it generates a different pulse shape and enables discrimination of pixel position. Recently, we have been successfully able to discriminate 25 averaged pulse shapes by means of rise-time and pulse height. The measured pulse shapes and distribution agree well with the modeling results. The estimated energy resolutions based on the pulse height and noise data we measured are 2.8–3.7 eV for MnKα X-ray photons at 50 mK.

Magnetic calorimeters↗

Development of Large-Scale Magnetic Calorimeter Arrays

We describe performance of large-scale arrays of metallic magnetic calorimeters (MMCs) we are developing to meet requirements of the Lynx X-ray Microcalorimeter (LXM) instrument in the astrophysics mission concept Lynx. We have fabricated prototypes with 55,800 x-ray pixels thermally connected to 5,688 MMC sensors. Subarrays demonstrate three types of pixels, which have different energy and spatial resolution goals in LXM. Pixel pitch is 50 or 25 µm. For two subarrays, use of position sensitive detectors, in a "hydra" configuration with 25 x-ray absorbers per sensor, helps achieve a large focal plane by increasing pixel count relative to readout channels. Since each absorber has a different thermal link to its sensor, it generates a different pulse shape and enables discrimination of pixel position. Superconducting wiring from all sensors was brought out to the perimeter of the overall array using multiple buried metal layers planarized by Chemical Mechanical Planarization to achieve high critical current, low inductance, and high fabrication yield. An automated, algorithmic approach was used to layout the complex wiring pattern. For readout with existing small arrays of Superconducting Quantum Interference (SQUID) amplifiers, 112 selected pixels were connected to wire bond pads. In hydras, we successfully identified 25 pulse shapes using rise-time and pulse height. Pulse shapes were similar to simulations. We measured noise and responsivity to substrate temperature and applied x-ray pulses. While we designed sensors to have high inductance to relative to stray inductance of wiring, we had only mismatched (lower input inductance) SQUIDs available in our current apparatus, giving non-optimized resolution. We compared measured and calculated energy resolutions. We have the required sensitivity to reach < 3 eV FWHM resolution for 6 keV x-rays, required for the LXM Main Array, and the ability to discriminate the 25 different absorber pixels down to energies < 300 eV.

microcalorimeters↗

Prototype Magnetic Calorimeter Arrays with Buried Wiring for the Lynx X-Ray Microcalorimeter

Metallic magnetic calorimeter (MMC) technology is a leading contender for detectors for the Lynx X-ray Microcalorimeter, which is an imaging spectrometer consisting of an array of greater than 100,000 pixels. The fabrication of such large arrays presents a challenge when attempting to route the superconducting wiring from the pixels to the multiplexed readout. If the wiring is designed to be planar, then an aggressive, submicron scale wiring pitch has to be employed, which is technically challenging to design and fabricate on account of the requirements of low inductance, low cross-talk, high critical currents and high yield. An alternative way to achieve large scale, high density wiring is through the use of multiple buried metal layers, planarized by Chemical Mechanical Planarization. This approach is well-suited for connecting thousands of pixels on a large focal plane to readout chips, and also for fabricating sensor meander coils with narrow line widths, which helps in increasing the sensor inductance and thus alleviates stray inductance issues associated with the wiring in large size arrays. In this work we describe the fabrication of high sensor inductance MMC arrays implementing Lynx concepts and incorporating multiple layers of buried Nb wiring. The detector array is composed of three sub-arrays with pixels optimized to meet the different science driven performance requirements of Lynx. In two of the sub-arrays we adopt a thermal multiplexing scheme to read out pixels by coupling 25 absorbers to a single sensor through thermal links of varied thermal conductance. We demonstrate the successful fabrication of multi-absorber MMCs with fine pitch pixels in very large size arrays.

Solid-State Physics↗

Magnetic Calorimeter Arrays with High Sensor Inductance and Dense Wiring

We describe prototype arrays of magnetically coupled microcalorimeters fabricated with an approach scalable to very large format arrays. The superconducting interconnections and sensor coils have sufficiently low inductance in the wiring and sufficiently high inductance in the coils in each pixel, to enable arrays containing greater than 4000 sensors and 100,000 X-ray absorbers to be used in future astrophysics missions such as Lynx. We have used projection lithography to create submicron patterns (e.g., 400-nanometer-lines and spaces) in our niobium sensor coils and wiring, integrated with gold-erbium sensor films and gold X-ray absorbers. Our prototype devices will explore the device physics of metallic magnetic calorimeters as feature sizes are reduced to nanoscale.

Magnetism↗

Theoretical Noise Analysis on a Position-sensitive Metallic Magnetic Calorimeter

We report on the theoretical noise analysis for a position-sensitive Metallic Magnetic Calorimeter (MMC), consisting of MMC read-out at both ends of a large X-ray absorber. Such devices are under consideration as alternatives to other cryogenic technologies for future X-ray astronomy missions. We use a finite-element model (FEM) to numerically calculate the signal and noise response at the detector outputs and investigate the correlations between the noise measured at each MMC coupled by the absorber. We then calculate, using the optimal filter concept, the theoretical energy and position resolution across the detector and discuss the trade-offs involved in optimizing the detector design for energy resolution, position resolution and count rate. The results show, theoretically, the position-sensitive MMC concept offers impressive spectral and spatial resolving capabilities compared to pixel arrays and similar position-sensitive cryogenic technologies using Transition Edge Sensor (TES) read-out.

Smith, Stephen J.↗

Demonstration of Time Domain Multiplexed Readout for Magnetically Coupled Calorimeters

Magnetically coupled calorimeters (MCC) have extremely high potential for x-ray applications due to the inherent high energy resolution capability and being non-dissipative. Although very high energy-resolution has been demonstrated, until now there has been no demonstration of multiplexed read-out. We report on the first realization of a time domain multiplexed (TDM) read-out. While this has many similarities with TDM of transition-edge-sensors (TES), for MGGs the energy resolution is limited by the SQUID read-out noise and requires the well established scheme to be altered in order to minimize degradation due to noise aliasing effects. In cur approach, each pixel is read out by a single first stage SQUID (SQ1) that is operated in open loop. The outputs of the SQ1 s are low-pass filtered with an array of low cross-talk inductors, then fed into a single-stage SQUID TD multiplexer. The multiplexer is addressed from room temperature and read out through a single amplifier channel. We present results achieved with a new detector platform. Noise performance is presented and compared to expectations. We have demonstrated multiplexed X-ray spectroscopy at 5.9keV with delta_FWHM=10eV. In an optimized setup, we show it is possible to multiplex 32 detectors without significantly degrading the Intrinsic detector resolution.

Porst, J.-P.↗

Magnetic Calorimeter Option for the Lynx X-Ray Microcalorimeter

One option for the detector technology to implement the Lynx x-ray microcalorimeter (LXM) focal plane arrays is the metallic magnetic calorimeter (MMC). Two-dimensional imaging arrays of MMCs measure the energy of x-ray photons by using a paramagnetic sensor to detect the temperature rise in a microfabricated x-ray absorber. While small arrays of MMCs have previously been demonstrated that have energy resolution better than the 3 eV requirement for LXM, we describe LXM prototype MMC arrays that have 55,800 x-ray pixels, thermally linked to 5688 sensors in “hydra” configurations, and that have sensor inductance increased to avoid signal loss from the stray inductance in the large-scale arrays when the detectors are read out with microwave superconducting quantum interference device multiplexers, and that use multilevel planarized superconducting wiring to provide low-inductance, low-crosstalk connections to each pixel. We describe the features of recently tested MMC prototype devices and simulations of expected performance in designs opti- mized for the three subarray types in LXM.

Stevenson, Thomas R.↗

Development of Metallic Magnetic Calorimeters for High Precision Measurements of Calorimetric Re-187 and Ho-163 Spectra

The measurement of calorimetric spectra following atomic weak decays, beta (b) and electron capture (EC), of nuclides having a very low Q-value, can provide an impressively high sensitivity to a non-vanishing neutrino mass. The achievable sensitivity in this kind of experiments is directly connected to the performance of the used detectors. In particular an energy resolution of a few eV and a pulse formation time well below 1 microsecond are required. Low temperature Metallic Magnetic Calorimeters (MMCs) for soft X-rays have already shown an energy resolution of 2.0 eV FWHM and a pulse rise-time of about 90 ns for fully micro-fabricated detectors. We present the use of MMCs for high precision measurements of calorimetric spectra following the beta-decay of Re-187 and the EC of Ho-163. We show results obtained with detectors optimized for Re-187 and for Ho-163 experiments respectively. While the detectors equipped with superconducting Re absorbers have not yet reached the aimed performance, a first detector prototype with a Au absorber having implanted Ho-163 ions already shows excellent results. An energy resolution of 12 eV FWHM and a rise time of 90 ns were measured.

Ranitzsch, P. C.-O.↗

Magnetically Coupled Calorimeters

Calorimeters that utilize the temperature sensitivity of magnetism have been under development for over 20 years. They have targeted a variety of different applications that require very high resolution spectroscopy. I will describe the properties of this sensor technology that distinguish it from other low temperature detectors and emphasize the types of application to which they appear best suited. I will review what has been learned so far about the best materials, geometries, and read-out amplifiers and our understanding of the measured performance and theoretical limits. I will introduce some of the applications where magnetic calorimeters are being used and also where they are in development for future experiments. So far, most magnetic calorimeter research has concentrated on the use of paramagnets to provide temperature sensitivity; recent studies have also focused on magnetically coupled calorimeters that utilize the diamagnetic response of superconductors. I will present some of the highlights of this research, and contrast the properties of the two magnetically coupled calorimeter types.

Bandler, Simon↗

Magnetically Coupled Microcalorimeters

Magnetic calorimeters have been under development for over 20 years targeting a wide variety of different applications that require very high resolution spectroscopy. They have a number of properties that distinguish them from other 10w temperature detectors. In this paper we review these properties and emphasize the types of application to which they are most suited. We will describe what has been learned about the best materials, geometries, and read-out amplifiers and our understanding of the measured performance and theoretical limits. While most magnetic calorimeter research has concentrated on the use of paramagnets to provide the temperature sensitivity, recently magnetically coupled microcalorimeters have been in development that utilize the diamagnetic response of superconductors. We will contrast some of the properties of the two different magnetic sensor types.

Bandler, S. R.↗

Superconducting Effects in Optimization of Magnetic Penetration Thermometers for X-ray Microcalorimeters

We have made high resolution x-ray microcalorimeters using superconducting MoAu bilayers and Nb meander coils. The temperature sensor is a Magnetic Penetration Thermometer (MPT). Operation is similar to metallic magnetic calorimeters, but instead of the magnetic susceptibility of a paramagnetic alloy, we use the diamagnetic response of the superconducting MoAu to sense temperature changes in an x-ray absorber. Flux-temperature responsivtty can be large for small sensor heat capacity, with enough dynamic range for applications. We find models of observed flux-temperature curves require several effects to explain flux penetration or expulsion in the microscopic devices. The superconductor is non-local, with large coherence length and weak pinning of flux. At lowest temperatures, behavior is dominated by screening currents that vary as a result of the temperature dependence of the magnetic penetration depth, modified by the effect of the nonuniformity of the applied field occurring on a scale comparable to the coherence length. In the temperature regime where responslvity is greatest, spadal variations in the order parameter become important: both local variations as flux enters/leaves the film and an intermediate state is formed, and globally as changing stability of the electrical circuit creates a Meissner transition and flux is expelled/penetrates to minimize free energy.

Stevenson, Thomas R.↗

NASA Tech Briefs, July 2011

Topics covered include: 1) Collaborative Clustering for Sensor Networks; 2) Teleoperated Marsupial Mobile Sensor Platform Pair for Telepresence Insertion Into Challenging Structures; 3) Automated Verification of Spatial Resolution in Remotely Sensed Imagery; 4) Electrical Connector Mechanical Seating Sensor; 5) In Situ Aerosol Detector; 6) Multi-Parameter Aerosol Scattering Sensor; 7) MOSFET Switching Circuit Protects Shape Memory Alloy Actuators; 8) Optimized FPGA Implementation of Multi-Rate FIR Filters Through Thread Decomposition; 9) Circuit for Communication Over Power Lines; 10) High-Efficiency Ka-Band Waveguide Two-Way Asymmetric Power Combiner; 11) 10-100 Gbps Offload NIC for WAN, NLR, and Grid Computing; 12) Pulsed Laser System to Simulate Effects of Cosmic Rays in Semiconductor Devices; 13) Flight Planning in the Cloud; 14) MPS Editor; 15) Object-Oriented Multi Disciplinary Design, Analysis, and Optimization Tool; 16) Cryogenic-Compatible Winchester Connector Mount and Retaining System for Composite Tubes; 17) Development of Position-Sensitive Magnetic Calorimeters for X-Ray Astronomy; 18) Planar Rotary Piezoelectric Motor Using Ultrasonic Horns; 19) Self-Rupturing Hermetic Valve; 20) Explosive Bolt Dual-Initiated from One Side; 21) Dampers for Stationary Labyrinth Seals; 22) Two-Arm Flexible Thermal Strap; 23) Carbon Dioxide Removal via Passive Thermal Approaches; 24) Polymer Electrolyte-Based Ambient Temperature Oxygen Microsensors for Environmental Monitoring; 25) Pressure Shell Approach to Integrated Environmental Protection; 26) Image Quality Indicator for Infrared Inspections; 27) Micro-Slit Collimators for X-Ray/Gamma-Ray Imaging; 28) Scatterometer-Calibrated Stability Verification Method; 29) Test Port for Fiber-Optic-Coupled Laser Altimeter; 30) Phase Retrieval System for Assessing Diamond Turning and Optical Surface Defects; 31) Laser Oscillator Incorporating a Wedged Polarization Rotator and a Porro Prism as Cavity Mirror; 32) Generic, Extensible, Configurable Push-Pull Framework for Large-Scale Science Missions; 33) Dynamic Loads Generation for Multi-Point Vibration Excitation Problems; 34) Optimal Control via Self-Generated Stochasticity; 35) Space-Time Localization of Plasma Turbulence Using Multiple Spacecraft Radio Links; 36) Surface Contact Model for Comets and Asteroids; 37) Dust Mitigation Vehicle; 38) Optical Coating Performance for Heat Reflectors of the JWST-ISIM Electronic Component; 39) SpaceCube Demonstration Platform; 40) Aperture Mask for Unambiguous Parity Determination in Long Wavelength Imagers; 41) Spaceflight Ka-Band High-Rate Radiation-Hard Modulator; 42) Enabling Disabled Persons to Gain Access to Digital Media; 43) Cytometer on a Chip; 44) Principles, Techniques, and Applications of Tissue Microfluidics; and 45) Two-Stage Winch for Kites and Tethered Balloons or Blimps.

Source record↗

Performance of Magnetic Penetration Thermometers for X-Ray Astronomy

The ideal X-ray camera for astrophysics would have more than a million pixels and provide an energy resolution of better than leV FWHM for energies up to 10 keY. We have microfabricated and characterized thin-film magnetic penetration thermometers (MPTs) that show great promise towards meeting these capabilities. MPTs operate in similar fashion to metallic magnetic calorimeters (MMCs), except that a superconducting sensor takes the place of a paramagnetic sensor and it is the temperature dependence of the superconductor's diamagnetic response that provides the temperature sensitivity. We present a description of the design and performance of our prototype thin-film MPTs with MoAu bilayer sensors, which have demonstrated an energy resolution of approx 2 eV FWHM at 1.5 keY and 4.3 eV FWHM at 5.9 keY.

Nagler, P. C.↗

Lynx x-ray microcalorimeter

Lynx is an x-ray telescope, one of four large satellite mission concepts currently being studied by NASA to be a flagship mission. One of Lynx’s three instruments is an imaging spectrometer called the Lynx x-ray microcalorimeter (LXM), an x-ray microcalorimeter behind an x-ray optic with an angular resolution of 0.5 arc sec and ∼2 sq. m of area at 1 keV. The LXM will provide unparalleled diagnostics of distant extended structures and, in particular, will allow the detailed study of the role of cosmic feedback in the evolution of the Universe. We discuss the baseline design of LXM and some parallel approaches for some of the key technologies. The baseline sensor technology uses transition-edge sensors, but we also consider an alternative approach using metallic magnetic calorimeters. We discuss the requirements for the instrument, the pixel layout, and the baseline readout design, which uses microwave superconducting quantum interference devices and high-electron mobility transistor amplifiers and the cryogenic cooling requirements and strategy for meeting these requirements. For each of these technologies, we discuss the current technology readiness level and our strategy for advancing them to be ready for flight. We also describe the current system design, including the block diagram, and our estimate for the mass, power, and data rate of the instrument.

Simon R. Bandler↗

Progress in the Development of Mo-Au Transition-Edge Sensors for X-Ray Spectroscopy

X-ray microcalorimeters using transition-edge sensors (TES) show great promise for use in astronomical x-ray spectroscopy. We have obtained very high energy resolution (2.8 electronvolts at 1.5 kiloelectronvolts and 3.7 electronvolts at 3.3 kiloelectronvolts) in a large, isolated TES pixel using a Mo/Au proximity-effect bilayer on a silicon nitride membrane. We will discuss the performance and our characterization of that device. In order to be truly suitable for use behind an x-ray telescope, however, such devices need to be arrayed with a pixel size and focal-plane coverage commensurate with the telescope focal length and spatial resolution. Since this requires fitting the TES and its thermal link, a critical component of each calorimeter pixel, into a far more compact geometry than has previously been investigated, we must study the fundamental scaling laws in pixel optimization. We have designed a photolithography mask that will allow us to probe the range in thermal conductance that can be obtained by perforating the nitride membrane in a narrow perimeter around the sensor. This mask will also show the effects of reducing the TES area. Though we have not yet tested devices of the compact designs, we will present our progress in several of the key processing steps and discuss the parameter space of our intended investigations.

of Magnetic Calorimeters for Applications in X-ray↗

Development of X-Ray Microcalorimeter Imaging Spectrometers for the X-Ray Surveyor Mission Concept

Four astrophysics missions are currently being studied by NASA as candidate large missions to be chosen inthe 2020 astrophysics decadal survey.1 One of these missions is the X-Ray Surveyor (XRS), and possibleconfigurations of this mission are currently under study by a science and technology definition team (STDT). Oneof the key instruments under study is an X-ray microcalorimeter, and the requirements for such an instrument arecurrently under discussion. In this paper we review some different detector options that exist for this instrument,and discuss what array formats might be possible. We have developed one design option that utilizes eithertransition-edge sensor (TES) or magnetically coupled calorimeters (MCC) in pixel array-sizes approaching 100kilo-pixels. To reduce the number of sensors read out to a plausible scale, we have assumed detector geometriesin which a thermal sensor such a TES or MCC can read out a sub-array of 20-25 individual 1 pixels. In thispaper we describe the development status of these detectors, and also discuss the different options that exist forreading out the very large number of pixels.

multiplexing↗

Observations of cosmic-ray electrons and positrons using an imaging calorimeter

A ballon-borne magnet spectrometer system was flown for 5.5 hr at an altitude of more than 117,00 feet from Prince Albert, Saskatchewan (Canada), on 1989 September 5, when the Newark neutron monitor rate was 2952. The instrument was a modified version of the one used to observe antiprotons in 1979. The most significant modification was the addition of an imaging calorimeter, 7.33 radiation lengths thick. Inclusion of the calorimeter has significantly improved the ability to distinguish electrons and positrons from the other constituents of the cosmic rays. The absolute electron flux has been determined in the energy interval 1.3-26 GeV. The electron spectrum at the top of the atmosphere was found to be J(sub e-) = 177E(exp -(3.15+/-0.13)) electrons/ sq m/(sr s GeV) in the energy range 4.0-26 GeV. Below 4 GeV, the spectrum showed flattening, which is consistent with the effect of solar modulation. The e(+)/(e(+)+e(-)) ratio was found to be (0.11 +/- 0.03) in the energy range 5.2-13 GeV.

Golden, R. L.↗