Search NASA⌕ Search

SEARCH · Search NASA

Results for “Magnetic field”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Wide-field microwave magnetic field imaging with nitrogen-vacancy centers in diamond

Non-invasive imaging of microwave (MW) magnetic fields with microscale lateral resolution is pivotal for various applications, such as MW technologies and integrated circuit failure analysis. Diamond nitrogen-vacancy (NV) center magnetometry has emerged as an ideal tool, offering micrometer-scale resolution, millimeter-scale field of view, high sensitivity, and non-invasive imaging compatible with diverse samples. However, up until now, it has been predominantly used for imaging of static or low-frequency magnetic fields or, concerning MW field imaging, to directly characterize the same microwave device used to drive the NV spin transitions. In this work, we leverage an NV center ensemble in diamond for wide-field imaging of MW magnetic fields generated by a test device employing a differential measurement protocol. The microscope is equipped with a MW loop to induce Rabi oscillations between NV spin states, and the MW field from the device-under-test is measured through local deviations in the Rabi frequency. This differential protocol yields magnetic field maps of a 2.57 GHz MW field with a sensitivity of ∼9 μT Hz −1/2 for a total measurement duration of T=357 s, covering a 340 × 340 μm 2 field of view with a micrometer-scale spatial resolution and a device-under-test input power dynamic range of 30 dB. This work demonstrates a novel NV magnetometry protocol, based on differential Rabi frequency measurement, that extends NV wide-field imaging capabilities to imaging of weak MW magnetic fields that would be difficult to measure directly through standard NV Rabi magnetometry.

crystallographic defects↗

Gradient Technique Theory: Tracing Magnetic Field and Obtaining Magnetic Field Strength

Abstract The gradient technique is a promising tool with theoretical foundations based on the fundamental properties of MHD turbulence and turbulent reconnection. Its various incarnations use spectroscopic, synchrotron, and intensity data to trace the magnetic field and measure the media magnetization in terms of Alfvén Mach number. We provide an analytical theory of gradient measurements and quantify the effects of averaging gradients along the line of sight and over the plane of the sky. We derive analytical expressions that relate the properties of gradient distribution with the Alfvén Mach number M A . We show that these measurements can be combined with measures of sonic Mach number or line broadening to obtain the magnetic field strength. The corresponding technique has advantages to the Davis–Chandrasekhar–Fermi way of obtaining the magnetic field strength.

79 ASTRONOMY AND ASTROPHYSICS↗

Trapped-ion entangling gates with bichromatic pair of microwave fields and magnetic field gradient

A trapped-ion quantum logic gate and a method of operating the trapped-ion quantum logic gate are provided. The trapped-ion quantum logic gate includes at least one ion having two internal states and forming a qubit having a qubit transition frequency ω 0 0, a magnetic field gradient, and two microwave fields. Each of the two microwave fields has a respective frequency that is detuned from the qubit transition frequency ω 0 by frequency difference δ. The at least one ion has a Rabi frequency Ω μ due to the two microwave fields and a Rabi frequency Ω g due to the magnetic field gradient. The method includes applying the magnetic field gradient and the two microwave fields to the at least one ion such that a quantity Ω g /δ is in a range between zero and 5×10 −2 .

Sutherland, Robert Tyler↗

Optical sensing of magnetic fields using magnetically sensitive materials

The invention provides a method for measuring the magnetic field of an electromagnetic component having the steps of: instrumenting one or more portions of an electromagnetic component by placing an optical fiber in electromagnetic communication with the one or more portions of said electromagnetic component; energizing the electromagnetic component; interrogating the optical fiber using light and an optical detector; and determining changes in the magnetic field incident on the optical fiber based on the detected changes in the light received by the optical detector.

Ohodnicki, Paul↗

Applied Magnetic Field Increases Magnetic Anisotropy in HDDR-Processed Nd-Fe-B Alloy

We investigate the effect of an applied magnetic field on the entire HDDR process using a customized reactor vessel and a warm-bore superconducting magnet. We analyzed the resulting properties produced at both a 0 applied field and a 2 Tesla applied field. We show that the application of a magnetic field throughout the HDDR process results in powders that exhibit a greater level of anisotropy compared to their ambient field counterparts.

36 MATERIALS SCIENCE↗

Modelling pulsed field magnetization of iron-based bulk superconductors

Abstract Bulk superconductors can be used as super-strength quasi-permanent magnets capable of providing magnetic flux densities considerably superior to conventional permanent magnets. This makes them attractive for several engineering applications that rely on strong magnetic fields like rotating machines, NMR/MRI and magnetic drug delivery systems. Recently, the authors reported a record trapped magnetic field in an iron-based bulk superconductor: 2.83 T was trapped in potassium-doped barium iron arsenide (Ba, K)Fe 2 As 2 (or Ba122) at 5 K. Of particular significance is that the strength and temporal stability of this magnetic field exceeds the requirements of MRI machines, indicating iron-based bulks can now perform at levels demanded by engineering applications. One crucial challenge for their practical use, however, is the need to apply and remove an external magnetic field to magnetize them. Pulsed field magnetization (PFM) shows great promise as a practical method of magnetizing bulks, but the process generates heat in the bulk that is detrimental to its superconducting performance and ability to act as a super-strength magnet. In this paper, coupled electromagnetic–thermal numerical models are used to simulate the PFM of iron-based bulk superconductors. Here we focus on the recent-record-breaking, fine-grain polycrystalline K-doped Ba122 bulks. The impact that the specific J c ( B ) characteristics and thermal properties of the Ba122 material—all of which have been experimentally measured from state-of-the-art samples—have on the magnetic flux dynamics and thermal behaviour during PFM, including the final trapped field, is investigated. We show that because the thermal properties are similar to those of REBa 2 Cu 3 O 7 −δ bulks, a similar response to pulsed fields is obtained. A maximum trapped field of ∼0.81 T (∼43.3% of the maximum trapped field capability under ideal, field-cooling conditions) was simulated at 5 K, with a magnetization efficiency of ∼54%. The modelling framework provides a fast and flexible tool for optimising the practical PFM process at different operating temperatures to maximise the trapped field in state-of-the-art Ba122 bulks and to guide the design of future experiments.

bulk superconductors↗

Analysis of Near-Field Magnetic Responses on ZrTe 5 through Cryogenic Magneto-THz Nano-Imaging

One manifestation of light-Weyl fermion interaction is the emergence of chiral magnetic effects under magnetic fields. Probing real space magnetic responses at terahertz (THz) scales is challenging but highly desired, as the local responses are less affected by the topologically trivial inhomogeneity that is ubiquitous in spatially averaged measurements. Here, we implement a cryogenic THz microscopy instrument under a magnetic field environment—a task only recently achieved. We explore the technical approach of this system and characterize the magnetic field’s influence on our AFM operation by statistical noise analysis. We find evidence for local near-field spatial variations in the topological semimetal ZrTe 5 up to a 5-Tesla magnetic field and obtain near-field THz spectra to discuss their implications for future studies on the chiral magnetic effect.

36 MATERIALS SCIENCE↗

Polarimetry-Interferometry Diagnostic for Magnetic Field and Magnetic Fluctuation Measurements in High-Performance and Long-Pulse Tokamaks (Final Report)

In this grant, we executed a multi-year plan to develop an advanced Faraday-effect polarimeter-interferometer system to address both fluctuation and equilibrium diagnostic needs by providing a measurement of the plasma internal magnetic field fluctuations (including non-axisymmetric 3-D perturbations) and plasma vertical position. This diagnostic included both fast time response and low phase noise so that both the temporal dynamics of equilibrium quantities as well as high-frequency electromagnetic fluctuations could be measured simultaneously, adding new and unique measurement capabilities for the core of high-temperature plasmas. The combined polarimeter-interferometer diagnostic development was applied primarily to the tokamak magnetic configuration, focusing on high-performance regimes including H-mode, reversed shear advanced tokamak scenarios, and non-inductive current drive.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Spatial heterodyne spectroscopy for fast local magnetic field measurements of magnetized fusion plasmas

A novel spectroscopy diagnostic for measuring internal magnetic fields in high temperature magnetized plasmas has been developed. It involves spectrally resolving the Balmer- α (656 nm) neutral beam radiation split by the motional Stark effect with a spatial heterodyne spectrometer (SHS). The unique combination of high optical throughput (3.7 mm 2 sr) and spectral resolution (δλ ~ 0.1 nm) allows these measurements to be made with time resolution $\ll$1 ms. The high throughput is effectively utilized by incorporating a novel geometric Doppler broadening compensation technique in the spectrometer. The technique significantly reduces the spectral resolution penalty inherent to using large area, high-throughput optics while still collecting the large photon flux provided by such optics. In this work, fluxes of order 10 10 s –1 support the measurement of deviations of <5 mT (Δ λ Stark ~ 10 –4 nm) in the local magnetic field with 50 µs time resolution. Example high time resolution measurements of the pedestal magnetic field throughout the ELM cycle of a DIII-D tokamak plasma are presented. Local magnetic field measurements give access to the dynamics of the edge current density, which is essential to understanding stability limits, edge localized mode generation and suppression, and predicting performance of H-mode tokamaks.

47 OTHER INSTRUMENTATION↗

Using Direct Laboratory Measurements of Electron Temperature Anisotropy to Identify the Heating Mechanism in Electron-Only Guide Field Magnetic Reconnection

Anisotropic electron heating during electron-only magnetic reconnection with a large guide magnetic field is directly measured in a laboratory plasma through in situ measurements of electron velocity distribution functions. Electron heating preferentially parallel to the magnetic field is localized to one separatrix, and anisotropies of 1.5 are measured. The mechanism for electron energization is identified as the parallel reconnection electric field because of the anisotropic nature of the heating and spatial localization. These characteristics are reproduced in a 2D particle-in-cell simulation and are also consistent with numerous magnetosheath observations. A measured increase in the perpendicular temperature along both separatrices is not reproduced by our 2D simulations. Here, this work has implications for energy partition studies in magnetosheath and laboratory reconnection.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

SEDONA and ERDE: Portable Detection of Chemical Agents by Low Magnetic Field Nuclear Magnetic Resonance [Slides]

Two spectrometer systems have been developed at LANL for hazardous and/or toxic chemical agent detection and forensic analysis: SpEctroscopic Detection Of Nerve Agents (SEDONA) is a portable bottle scanner; and Earth’s field Resonance Detection and Evaluation (ERDE) Devices are fieldable J-coupled Earth’s Field - NMR (EF-NMR) spectrometers.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Magnetic Field Mapping of a 2.5 T Fixed-Field HTS Gantry Magnet for Proton Therapy

We present results from testing a high-temperature superconducting (HTS) magnet prototype for proton therapy. This magnet is specifically designed for a novel rotating gantry capable of delivering the entire proton beam energy range (70225 MeV) while maintaining a fixed magnetic field in the superconducting magnets. The gantry layout simplifies the magnet design, enabling the use of straight, flat racetrack Bi-2223 (DI-BSCCO) coil technology and operation at higher temperatures (1015 K). The magnet has a non-linear field distribution for bending and focusing the proton beams. To validate this feature, we developed a system for measuring the magnetic field distribution in the magnet aperture. We present the design of this hall probe array and experimental results from two different magnet tests at 4.2 K in a liquid helium bath. These results are compared with the simulated field distribution and discussed in the context of the required field quality for the application.

Mosat, M↗

Cosmic recombination in the presence of primordial magnetic fields

Primordial magnetic fields (PMFs) may explain observations of magnetic fields on extragalactic scales. They are most cleanly constrained by measurements of cosmic microwave background radiation (CMB) anisotropies. Their effects on cosmic recombination may even be at the heart of the resolution of the Hubble tension. We present the most detailed analysis of the effects of PMFs on cosmic recombination to date. To this end we extend the public magneto-hydrodynamic code ENZO with a new cosmic recombination routine, Monte-Carlo simulations of Lyman-α photon transport, and a Compton drag term in the baryon momentum equation. The resulting code allows us, for the first time, to realistically predict the impact of PMFs on the cosmic ionization history and the clumping of baryons during cosmic recombination. Our results identify the importance of mixing of Lyman-α photons between overdense- and underdense- regions for small PMF strength. This mixing speeds up recombination beyond the speed-up due to clumping. We also investigate the effects of pecuilar flows on the recombination rate and find it to be small for small PMF strengths. For non-helical PMFs with a Batchelor spectrum we find a surprising dependency of results on ultra-violet magnetic modes. We further show that the increase in the ionization fraction at low redshift by hydrodynamic baryon heating due to PMF dissipation is completely compensated by the faster recombination from baryon clumping. In conclusion, the present study shall serve as a theoretical foundation for a future precise comparison of recombination with PMFs to CMB data.

79 ASTRONOMY AND ASTROPHYSICS↗

Temperature-dependent magnetic-field-induced ab -plane Gd spin reorientations in antiferromagnetic domains in a single crystal of the tetragonal A-type antiferromagnet GdRh 2 Si 2

The compound GdRh 2 Si 2 crystallizes in the body-centered tetragonal ThCr 2 Si 2 structure and exhibits A-type antiferromagnetic order below its Néel temperature T N = 107 K where the Gd moments are ferromagnetically aligned in the ab-plane with the moments in adjacent planes aligned antiferromagnetically. Previously, the nonlinear low-field magnetization versus field M ab ( H ∥ [1, 0, 0]) measurements on single crystals were interpreted in terms of a mean-field model. Here, in this work, we reinterpret this nonlinearity more simply in terms of the response of the ordered moments in four noninteracting tetragonal domains to the applied field and find good agreement with our theory.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Demonstrating magnetic field robustness and reducing temporal T1 noise in transmon qubits through magnetic field engineering

The coherence of superconducting transmon qubits is often disrupted by fluctuations in the energy relaxation time (T1), limiting their performance for quantum computing. While background magnetic fields can be harmful to superconducting devices, we demonstrate that both trapped magnetic flux and externally applied static magnetic fields can suppress temporal fluctuations in T1 without significantly degrading its average value or qubit frequency. Using a three-axis Helmholtz coil system, we applied calibrated magnetic fields perpendicular to the qubit plane during cooldown and operation. Remarkably, transmon qubits based on tantalum-capped niobium (Nb/Ta) capacitive pads and aluminum-based Josephson junctions (JJs) maintained T1 lifetimes near 300 μs even when cooled in fields as high as 600 mG. Both trapped flux up to 600 mG and applied fields up to 400 mG reduced T1 fluctuations by more than a factor of two, while higher field strengths caused rapid coherence degradation. We attribute this stabilization to the polarization of paramagnetic impurities, the role of trapped flux as a sink for non-equilibrium quasiparticles (QPs), and partial saturation of fluctuating two-level systems (TLSs). These findings challenge the conventional view that magnetic fields are inherently detrimental and introduce a strategy for mitigating noise in superconducting qubits, offering a practical path toward more stable and scalable quantum systems.

Abdisatarov, Bektur [Fermilab; Jefferson Lab]↗

Effect of printing parameters on 3D-printed carbon fiber-reinforced polymer composites under magnetic field control

Magnetic field controlled (MFC) 3D printing is a promising method for realizing the intelligent control of the structural performance of carbon fiber-reinforced plastic (CFRP) composites by adjusting the fiber orientation during the printing process. However, few studies have focused on the influence of the printing parameters on the magnetic control of the fiber direction. Therefore, in this study, the mechanical properties and internal fiber distributions of MFC 3D-printed samples of CFRP composites with 10 wt% fiber content, which were printed at different speeds and layer thicknesses, were investigated. Subsequently, the effects of the fiber content on the mechanical properties and fiber distribution of the MFC 3D-printed samples were studied. Furthermore, the origin of fiber fracture was evaluated through observation and analysis of the fracture section using scanning electron microscopy. The fiber orientation could be well adjusted under the action of a magnetic field and adjustment of printing parameters, thereby improving the tensile strength, young's modulus significantly with slightly decrease of fracture elongation. The recommended parameter combinations (printing speed and layer thickness) were 40 mm/s and 0.2 mm for 10 wt% fiber content CFRP composites.

36 MATERIALS SCIENCE↗

A Brillouin light scattering study of the spin-wave magnetic field dependence in a magnetic hybrid system made of an artificial spin-ice structure and a film underlayer

We present a combined Brillouin light scattering (BLS) and micromagnetic simulation investigation of the magnetic-field-dependent spin-wave spectra in a hybrid structure made of permalloy (NiFe) artificial spin-ice (ASI) systems, composed of stadium-shaped nanoislands, deposited on the top of an unpatterned permalloy film with a nonmagnetic spacer layer. The thermal spin-wave spectra were recorded by BLS as a function of the magnetic field applied along the symmetry direction of the ASI sample. Magneto-optic Kerr effect magnetometry was used to measure the hysteresis loops in the same orientation as the BLS measurements. Here, the frequency and the intensity of several spin-wave modes detected by BLS were measured as a function of the applied magnetic field. Micromagnetic simulations enabled us to identify the modes in terms of their frequency and spatial symmetry and to extract information about the existence and strength of the dynamic coupling, relevant only to a few modes of a given hybrid system. Using this approach, we suggest a way to understand if the dynamic coupling between ASI and film modes is present or not, with interesting implications for the development of future three-dimensional magnonic applications and devices.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Hot-spot model for inertial confinement fusion implosions with an applied magnetic field

Imposing a magnetic field on inertial confinement fusion implosions magnetizes the electrons in the compressed fuel; this suppresses thermal losses, which increases temperature and fusion yield. Indirect-drive experiments at the National Ignition Facility with 12 and 26 T applied magnetic fields demonstrate up to 40% increase in temperature, 3× increase in fusion yield, and indicate that magnetization alters the radial temperature profile [Moody et al., Phys. Rev. Lett. 129, 195002 (2022); Lahmann et al., APS DPP (2022)]. In this work, we develop a semi-analytic hot-spot model, which accounts for the two-dimensional (2D) Braginskii anisotropic heat flow due to an applied axial magnetic field. First, we show that hot-spot magnetization alters the radial temperature profile, increasing the central peakedness, which is most pronounced for moderately magnetized implosions (with 8–14 T applied field), compared to both unmagnetized (with no applied field) and highly magnetized (with 26 T or higher applied field) implosions. This model explains the trend in the experimental data, which finds a similarly altered temperature profile in the 12 T experiment. Next, we derive the hot-spot model for gas-filled (Symcap) implosions, accounting for the effects of magnetization on the thermal conduction and in changing the radial temperature (and density) profiles. Using this model, we compute predicted central temperature amplification and yield enhancement scaling with the applied magnetic field. The central temperature fits the experimental data accurately, and the discrepancy in the yield suggests a systematic (independent of applied field) degradation, such as mix, and additional degradation in the reference unmagnetized shot, such as reduced laser drive, increased implosion asymmetry, or the magnetic field suppressing ablator mixing into the hot-spot.

Alpha particles↗