At least 19 records

Magnetic Force Microscopy Images of Magnetic Garnet With Thin-Film Magnetic Tip

We present magnetic force microscopy images of YGdTmGa/YSmTmGa magnetic garnet, usinga thin Fe film deposited on Si_3N_5 tips. We have found correlations between the topography andthe magnetic domain structure. We have observed the domain wall contrast with a iron thin-film tip. We report on domain wall imaging of garnet with magnetic force microscopy.

Wadas, A.↗

Tunneling magnetic force microscopy

We have developed a powerful new tool for studying the magnetic patterns on magnetic recording media. This was accomplished by modifying a conventional scanning tunneling microscope. The fine-wire probe that is used to image surface topography was replaced with a flexible magnetic probe. Images obtained with these probes reveal both the surface topography and the magnetic structure. We have made a thorough theoretical analysis of the interaction between the probe and the magnetic fields emanating from a typical recorded surface. Quantitative data about the constituent magnetic fields can then be obtained. We have employed these techniques in studies of two of the most important issues of magnetic record: data overwrite and maximizing data-density. These studies have shown: (1) overwritten data can be retrieved under certain conditions; and (2) improvements in data-density will require new magnetic materials. In the course of these studies we have developed new techniques to analyze magnetic fields of recorded media. These studies are both theoretical and experimental and combined with the use of our magnetic force scanning tunneling microscope should lead to further breakthroughs in the field of magnetic recording.

Burke, Edward R.↗

Imaging Domains In Magnetic Garnets By Use Of TSMFM

Tunneling-stabilized magnetic-force microscopy (TSMFM) demonstrated to yield images of magnetic domains in low-coercivity magnetic garnets with perpendicular anisotropy. Ability to generate images of domain walls and minute vertical Bloch lines aids study of vertical-Bloch-line magnetic memory devices that contain garnets. TSMFM provides desired resolution because its resolution not limited by diffraction.

Katti, Romney R.↗

Characterization facility for magneto-optic media and systems

Objectives of this research are: (1) to measure the hysteresis loop, Kerr rotation angle, anisotropy energy profile, Hall voltage, and magnetoresistance of thin-film magneto-optic media using our loop-tracer; (2) measure the wavelength-dependence of the Kerr rotation angle, Theta(sub k), and ellipticity, epsilon(sub k), for thin-film media using our magneto-optic Kerr spectrometer (MOKS); (3) measure the dielectric tensor of thin-film and multilayer samples using our variable-angle magneto-optic ellipsometer (VAMOE); (4) measure the hysteresis loop, coercivity, remanent magnetization, saturation magnetization, and anisotropy energy constant for thin film magnetic media using vibrating sample magnetometry; (5) observe small magnetic domains and investigate their interaction with defects using magnetic force microscopy; (6) perform static read/write/erase experiments on thin-film magneto-optic media using our static test station; (7) integrate the existing models of magnetization, magneto-optic effects, coercivity, and anisotropy in an interactive and user-friendly environment, and analyze the characterization data obtained in the various experiments, using this modeling package; (8) measure focusing- and tracking-error signals on a static testbed, determine the 'feedthrough' for various focusing schemes, investigate the effects of polarization and birefringence, and compare the results with diffraction-based calculations; and (9) measure the birefringence of optical disk substrates using two variable angle ellipsometers.

Mansuripur, M.↗

Imaging Carbon Nanotubes in High Performance Polymer Composites via Magnetic Force Microscope

Application of carbon nanotubes as reinforcement in structural composites is dependent on the efficient dispersion of the nanotubes in a high performance polymer matrix. The characterization of such dispersion is limited by the lack of available tools to visualize the quality of the matrix/carbon nanotube interaction. The work reported herein demonstrates the use of magnetic force microscopy (MFM) as a promising technique for characterizing the dispersion of nanotubes in a high performance polymer matrix.

Lillehei, Peter T.↗

Lunar and Planetary Science XXXV: Achondrite Mishmash

The session "Achondrite Mishmash" included teh following presentations:Constraining the Formation and Evolution of IAB Irons - High Precision; 40Ar/39Ar Ages on Plagioclase Separates from Silicate Inclusions of the Campo Del Cielo Meteorite; Radiogenic 129-Xenon in Silicate Inclusions in the Campo Del Cielo Iron Meteorite; Significance of Iron Isotope Mineral Fractionation in Pallasite and Iron Meteorites; An Experimental Study of Phosphoran Olivine and Its Significance in Main Group Pallasites; Characterization of the Distribution of Siderophile and Highly Siderophile Elements in the Milton and Eagle Station Pallasites; Relationships Between HED and Mesosiderite Meteorites: An Iron Isotope Perspective; Production Rates for Noble-Gas Isotopes in Eucrites; Evidence for Subsolidus Metasomatism in the Eucrite Parent Body; Possible Contact Metamorphism of the Polymict Eucrite Petersburg; Early and Late Stage Metals and Sulfides in Diogenites; Constraints on the Lithological Variation near the Surface of the HED Planetoid from the Petrology of 91 & 92 Series Antarctic Achondrites; Cosmic Ray Exposure Ages, Ar-Ar Ages, and the Origin and History of Eucrites; Trace Elements Abundances Vs Closure Temperature in Orthopyroxenes from Howardites; The First Mesosiderite-like Clast in a Howardite; 39Ar-40Ar Dating of Unusual Eucrite NWA 011: Is it from Vesta?; Trace Element Systematics of Northwest Africa 011: A "Eucritic" Basalt from a Non-Eucrite Parent Body ; 33S Anomaly in Acapulcoites and Lodranites; Magnetic Force Microscopy of Primitive Achondrites; Experimental Constraints on Ureilite Petrogenesis; Reflectance Spectra of Ureilites: Nature of the Mafic Silicate Absorption Features; Nitrogen and Noble Gases in Two Monomict Ureilites Acfer 277 and FRO 90036 from Hot and Cold Deserts; Solar Noble Gases in the Angrite Parent Body - Evidence from Volcanic Volatiles Trapped in D'Orbigny Glass; Trace Element Distribution Between Phases of the D'Orbigny Angrite ; Petrological Study of Six Angrites Including New Type; and Manganese-Chromium Isotope Systematics of Basaltic Achondrite Northwest Africa 011.

Source record↗

Curvature induced by amyloplast magnetophoresis in protonemata of the moss Ceratodon purpureus

After gravistimulation of Ceratodon purpureus (Hedw.) Brid. protonemata in the dark, amyloplast sedimentation was followed by upward curvature in the wild-type (WT) and downward curvature in the wwr mutant (wrong way response). We used ponderomotive forces induced by high-gradient magnetic fields (HGMF) to simulate the effect of gravity and displace the presumptive statoliths. The field was applied by placing protonemata either between two permanent magnets at the edge of the gap, close to the edge of a magnetized ferromagnetic wedge, or close to a small (<1 mm) permanent magnet. Continuous application of an HGMF in all three configurations resulted in plastid displacement and induced curvature in tip cells of WT and wwr protonemata. WT cells curved toward the HGMF, and wwr cells curved away from the HGMF, comparable to gravitropism. Plastids isolated from protonemal cultures had densities ranging from 1.24 to 1.38 g cm-3. Plastid density was similar for both genotypes, but the mutant contained larger plastids than the WT. The size difference might explain the stronger response of the wwr protonemata to the HGMF. Our data support the plastid-based theory of gravitropic sensing and suggest that HGMF-induced ponderomotive forces can substitute for gravity.

Non-NASA Center↗

NASA Tech Briefs, December 2005

Topics covered include: Video Mosaicking for Inspection of Gas Pipelines; Shuttle-Data-Tape XML Translator; Highly Reliable, High-Speed, Unidirectional Serial Data Links; Data-Analysis System for Entry, Descent, and Landing; Hybrid UV Imager Containing Face-Up AlGaN/GaN Photodiodes; Multiple Embedded Processors for Fault-Tolerant Computing; Hybrid Power Management; Magnetometer Based on Optoelectronic Microwave Oscillator; Program Predicts Time Courses of Human/ Computer Interactions; Chimera Grid Tools; Astronomer's Proposal Tool; Conservative Patch Algorithm and Mesh Sequencing for PAB3D; Fitting Nonlinear Curves by Use of Optimization Techniques; Tool for Viewing Faults Under Terrain; Automated Synthesis of Long Communication Delays for Testing; Solving Nonlinear Euler Equations With Arbitrary Accuracy; Self-Organizing-Map Program for Analyzing Multivariate Data; Tool for Sizing Analysis of the Advanced Life Support System; Control Software for a High-Performance Telerobot; Java Radar Analysis Tool; Architecture for Verifiable Software; Tool for Ranking Research Options; Enhanced, Partially Redundant Emergency Notification System; Close-Call Action Log Form; Task Description Language; Improved Small-Particle Powders for Plasma Spraying; Bonding-Compatible Corrosion Inhibitor for Rinsing Metals; Wipes, Coatings, and Patches for Detecting Hydrazines; Rotating Vessels for Growing Protein Crystals; Oscillating-Linear-Drive Vacuum Compressor for CO2; Mechanically Biased, Hinged Pairs of Piezoelectric Benders; Apparatus for Precise Indium-Bump Bonding of Microchips; Radiation Dosimetry via Automated Fluorescence Microscopy; Multistage Magnetic Separator of Cells and Proteins; Elastic-Tether Suits for Artificial Gravity and Exercise; Multichannel Brain-Signal-Amplifying and Digitizing System; Ester-Based Electrolytes for Low-Temperature Li-Ion Cells; Hygrometer for Detecting Water in Partially Enclosed Volumes; Radio-Frequency Plasma Cleaning of a Penning Malmberg Trap; Reduction of Flap Side Edge Noise - the Blowing Flap; and Preventing Accidental Ignition of Upper-Stage Rocket Motors.

Source record↗

KLASS: Kennedy Launch Academy Simulation System

Software provides access to many sophisticated scientific instrumentation (Scanning Electron Microscope (SEM), a Light Microscope, a Scanning Probe Microscope (covering Scanning Tunneling, Atomic Force, and Magnetic Force microscopy), and an Energy Dispersive Spectrometer for the SEM). Flash animation videos explain how each of the instruments work. Videos on how they are used at NASA and the sample preparation. Measuring and labeling tools provided with each instrument. Hands on experience of controlling the virtual instrument to conduct investigations, much like the real scientists at NASA do. Very open architecture. Open source on SourceForge. Extensive use of XML Target audience is high school and entry-level college students. "Many beginning students never get closer to an electron microscope than the photos in their textbooks. But anyone can get a sense of what the instrument can do by downloading this simulator from NASA's Kennedy Space Center." Science Magazine, April 8th, 2005

Garner, Lesley C.↗

Rapid Solidification of Magnetic Oxides

The enhanced control over microstructural evolution inherent in rapid solidification processing techniques are exploited to create novel ceramic magnetic materials. The great sensitivity of magnetic properties to local structure provides a powerful probe both for the study of structure and of microscopic solidification mechanisms. The first system studied is the SrO-Fe2O3 binary, which contains the commercially important hard magnetic compound strontium hexaferrite. The products were analyzed by transmission electron microscopy, Mossbauer spectroscopy, magnetic measurements, and differential thermal analysis. As-quenched ribbons contain high concentrations of super-paramagnetic particles, 80 to 250 Angstroms in diameter, in a glassy matrix. This suggests the possibility of crystallizing monodomain strontium hexaferrite during subsequent heat treatment, with a resulting increase in coercivity over conventionally processed ferrite magnets. That magnetic properties can be controlled in solidification processing by varying the quench rate is demonstrated.

Kalonji, G.↗

Characteristics of first order shock induced magnetic transitions in iron and discrimination from TRM

Reflected light microscopy provides information on first-order shock transitions in iron and iron-nickel and permits discrimination of microstructures due to shock transitions from those imparted by thermal transitions. In addition, thin-foil electron microscopy is used to characterize magnetic transitions in fine-particle iron. First-order magnetic phase changes, such as that from the antiferromagnetic face centered cubic state to the ferromagnetic body centered cubic state, are studied with the aim of calibrating the shock and thermal mechanisms of magnetization in iron with a particle size range between 250 and 1200 A. The efficiency of remanence due to shock transition is also estimated.

Wasilewski, P.↗

Solar wind and micrometeorite alteration of the lunar regolith

Developments in the understanding of reduction processes which occur in the lunar regolith as a result of solar-wind bombardment and micrometeorite impacts are discussed. The mechanism is described by which water released during reduction is removed from the lunar surface, and the possible contribution of solar-wind sputtering to the reduction process is considered. It is shown that the overall reduction efficiency of incoming hydrogen ions may reach several per cent, which is sufficient to produce all the metallic iron observed in the regolith. Mossbauer spectroscopic data on the amount of metallic iron present as isolated atoms or small clusters in reduced grain surfaces are presented together with data on the metallic iron content of fines samples obtained by Mossbauer spectroscopy, ferromagnetic resonance, and scanning as well as transmission electron microscopy. A portable magnetic probe is described which has been designed for determining surface-exposure age profiles in intact lunar core and drive-tube samples.

Housley, R. M.↗

A Deuterium NMR Study of Bent-Core Liquid Crystals: Synthesis and Characterization of Deuterium-Labeled Oxadiazole-Containing Liquid Crystals - 1

We have synthesized two deuterated boomerang-shaped liquid crystals based on 2,5-bis(4-hydroxyphenyl)-1,3,4-oxadiazole (ODBP). Deuterium was introduced in the rigid 2,5-diphenyl-1,3,4-oxadiazole core and in the aromatic ring of the terminal 4-dodecyloxyphenyl moiety using standard acid catalyzed deuterium exchange conditions. Both compounds, ([4,4'(1,3,4-oxadiazole-2,5-diyl-d4)] di-4-dodecyloxybenzoate: ODBP-d4-Ph-O-C12) and ([4,4'(1,3,4-oxadiazole-2,5-diyl)] di-4-dodecyloxy-benzoate-d4; ODBP-Ph-d4-O-C12) were investigated by nuclear magnetic resonance, optical microscopy and differential scanning calorimetry. The optical textures and thermal behavior of both compounds were found to be identical to the non-deuterated analog [4,4(1,3,4-oxadiazole-2,5-diyl)] di-4-dodecyloxybenzoate (ODBP-Ph-O-C12) which we reported earlier. These compounds exhibit behavior indicative of a biaxial nematic liquid crystal phase, which we hope to confirm using deuterium NMR spectroscopy in the next phase of this study.

Dingemans, Theo J.↗

Fast Characterization of Magnetic Impurities in Single-Wall Carbon Nanotubes

We have demonstrated that the magnetic susceptibility measurement is a non-destructive, fast and accurate method to determine the residual metal catalysts in a few microgram single-wall carbon nanotube (SWCNT) sample. We have studied magnetic impurities in raw and purified SWCNT by magnetic susceptibility measurements, transmission electron microscopy, and thermogravimetry. The data suggest that the saturation magnetic moment and the effective field, which is caused by the interparticle interactions, decreases and increases respectively with the decrease of the particle size. Methods are suggested to overcome the uncertainty associated.

Chen, Feng↗

Effects of wear on structure-sensitive magnetic properties of ceramic ferrite in contact with magnetic tape

Wear experiments and electron microscopy and diffraction studies were conducted to examine the wear and deformed layers in single-crystal Mn-Zn (ceramic) ferrite magnetic head material in contact with magnetic tape and the effects of that contact on magnetic properties. The crystalline state of the single-crystal magnetic head was changed drastically during the sliding process. A nearly amorphous structure was produced on its wear surface. Deformation in the surficial layer of the magnetic head was a critical factor in readback signal loss above 2.5 dB. The signal output level was reduced as applied normal load was increased. Considerable plastic flow occurred on the magnetic tape surface with sliding, and the signal loss due to the tape wear was approximately 1 dB.

Miyoshi, K.↗