DSMC Modeling of the Differentially Pumped Magnum-PSI Vacuum System

The FOM Institute for Plasma Physics Rijnhuizen (FOM = Foundation for Fundamental Research on Matter) has started a new line of research to study the interaction of intense plasma fluxes with a material surface. An important experimental tool for this programme will be the Magnum-PSI high-flux linear plasma generator operating in the ITER-relevant regime of plasma surface interaction (PSI). ITER is the next step in fusion reactor research (ITER is Latin for 'the way'). In Magnum-PSI a plasma beam is guided from the source to a target by a strong axial magnetic field. Besides ionized particles, the plasma source produces hot neutral gas which has to be prevented from reaching the target region. In this paper it is investigated to what extent a differential pumping scheme can prevent the influx of neutral gas from the source in the target region. The results of neutral gas simulations using the Direct Simulation Monte Carlo (DSMC) method will be discussed. We will focus on the supersonic expansion as a function of background pressure and determine the influence of the skimmers on the expansion. We will demonstrate that differential pumping can be used in Magnum-PSI to reach low enough pressures in the target region. Finally, we give the optimum position of the skimmer.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Effect of detachment on Magnum-PSI ELM-like pulses: direct observations and qualitative results

Abstract Conditions similar to those at the end of the divertor leg in a tokamak were replicated in the linear plasma machine Magnum-PSI. The neutral pressure in the target chamber is then increased to cause the target to transition from an attached to a detached state. Superimposed to this steady state regime, edge localised mode (ELM)-like pulses are reproduced, resulting in a sudden increase in plasma temperature and density, such that the heat flux increases transiently by half an order of magnitude. Visible light emission, target thermography, and Thomson scattering are used to demonstrate that the higher the neutral pressure the more energy is removed from the ELM-like pulse in the volume. If the neutral pressure is sufficiently high, the ELM-like pulse can be prevented from affecting the target and the plasma energy is fully dissipated in the volume instead (ID 4 in table 1). The visible light images allow the division of the ELM-plasma interaction process of ELM energy dissipation into 3 ‘stages’ ranging from no dissipation to full dissipation (the target plasma is detached). In the second publication related to this study, spectroscopic data is analysed with a Bayesian approach, to acquire insights into the significance of molecular processes in dissipating the plasma energy and particles.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Experimental evaluation of the vapor box divertor concept with an open vapor box module in Magnum-PSI

A promising approach to handle the intense plasma heat flux in the divertor region of a tokamak is the Vapor Box Divertor (VBD). Here plasma-lithium interaction creates a dense lithium vapor cloud which interacts with the incoming plasma, effectively shielding the tungsten surface beneath, therefore preventing overheating and sputtering of the tungsten and increasing the component’s lifetime. Two key steps must be addressed to validate this concept: investigating plasma-Li interactions and the transport mechanism of the latter in the presence of plasma. To explore this, a Vapor Box Module (VBM) has been designed for use with the linear plasma generator Magnum-PSI. The VBM consists of a series of three cylindrical boxes, with Li being evaporated at a controlled temperature in the central box (CB). Divertor-like plasma enters the VBM from an upstream aperture, interacts with the Li vapor cloud and exits through a downstream aperture ultimately impacting a target equipped with a calorimetry system. Optical diagnostics Thomson scattering, Filtered fast camera Imaging and optical emission spectroscopy provided information on plasma parameters in terms of electron density n e , temperature T e and plasma composition before and after this interaction. A significant reduction in plasma power was observed upon the establishment of lithium vaporization determined via cooling water calorimetry and embedded thermocouples at the downstream target. This resulted in a drop of the target temperature from ∼800 °C to ∼350 °C (57%) at the highest applied power (11.1 MW m −2 ) and CB temperature (∼700 °C). Lithium condensation at the side boxes of the VBM in combination with strong plasma momentum transfer effectively prevented upstream migration of lithium, while enhancing Li transport toward the target. The achievement of the two main goals of reducing plasma power and confining the Li in the VBM, are consistent with earlier published preliminary SOLPS-ITER simulations. This study shows that the presence of lithium in a VBD-like configuration can result in a strong reduction of power to the target surface, while at the same time the lithium vapor is effectively confined by the VBM, aided by the incoming plasma, preventing its escape from the VBM geometry. This represents a valuable step toward validating the feasibility of the VBD configuration in future fusion reactors.

Magnum-PSI↗

Use of machine learning for a helium line intensity ratio method in Magnum-PSI

Optical emission spectroscopy (OES) of helium (He) line intensities has been used to measure the electron density, ne, and temperature, Te, in various plasma devices. In this study, a neural network with five hidden layers is introduced to model the relation between the OES data and ne/Te from laser Thomson scattering in the linear plasma device Magnum-PSI and compared to multiple regression analysis. It is shown that the neural network reduces the residual errors of prediction values (ne and Te) less than half those of the multiple regression analysis. We checked two different data splitting methods for training and validation data, i.e., with and without considering the unit of discharge. A comparison of the splitting methods suggests that the residual error will decrease to ~10% even for a new discharge data when accumulating a sufficient data set.

Kajita, Shin↗

Experimental investigation of a closed vapour box module for a divertor-like configuration in Magnum-PSI

Efficient management of extreme heat fluxes in the divertor region to extend the lifetime of the components remains a critical challenge for the realization of nuclear fusion-based power plants. Among the alternative concepts explored for the divertor region, the use of liquid metals, particularly lithium, is of interest due its ability to dissipate the incoming plasma heat flux through the vapour shielding effect (VS). In this work, we experimentally investigated a ‘closed’ configuration of a dedicated Vapour Box Module (VBM) in the linear plasma device Magnum-PSI. The goal of the experiments is to simulate the vapour box divertor environment conditions and assess its performance in terms of power mitigation and redistribution and lithium confinement. Initial testing without Li demonstrated the efficacy of a closed VBM structure in inducing detachment via neutral gas accumulation. Apertures which enabled non-condensing gas to be effectively pumped while ensuring lithium condensed on the inner surfaces were therefore added. With a lithium capillary porous structure target used, lithium is directly vaporized by the plasma, forming a dense lithium vapour cloud that interacts with the incoming plasma. This resulted in a significant reduction of the target temperature of at least 48%, together with a temperature locking effect, a phenomenon typically observed in the VS regime. Lithium vapour confinement within the VBM was strongly correlated with the wall temperature. Relatively cold walls promoted Li re-condensation and therefore improved Li confinement, although with the expected trade-off of increased hydrogenic retention on lithium-wetted surfaces. As the wall temperature increased, the confinement efficiency decreased, consistent with reduced Li re-condensation and thermally activated Li–H chemistry and remobilization at the walls. Diagnostic measurements through embedded thermocouples and calorimetry revealed that lithium vaporization and re-condensation processes also playedsignificant roles in plasma power dissipation. The results advance the case for a closed divertor chamber with direct lithium evaporation from the strike-points as a viable method to manage divertor heat fluxes in future fusion reactors.

Romano, Fabio [Dutch Institute for Fundamental Ene↗

Physics design for a lithium vapor box divertor experiment on Magnum-PSI

The lithium vapor box divertor is a potential solution for power exhaust in toroidal confinement devices. The divertor plasma interacts with a localized, dense cloud of lithium vapor, leading to volumetric radiation, cooling, recombination, and detachment. To minimize contamination of the core plasma, lithium vapor is condensed on cool (300°C to 400°C) baffles upstream of the detachment point. Before implementing this in a toroidal plasma device with a slot divertor geometry, we consider an experiment with a scaled baffled-pipe geometry in the high-power linear plasma device Magnum-PSI. Three 15 cm-scale open cylinders joined by 6 cm diameter ‘nozzles’ are positioned on the plasma beam axis upstream of a target. The central box may be loaded with several tens of grams of lithium, which can be evaporated at 650°C to produce a vapor predicted, using a simple plasma-neutral interaction model, to be dense enough to cause volumetric detachment in the plasma. The power delivered to the target and box walls as measured by increases in their temperatures after a 10 s plasma pulse can be compared to determine the effectiveness of the vapor in detaching the plasma. Direct Simulation Monte Carlo simulations are performed to estimate the flow rates of lithium vapor between the boxes and to estimate the trapping of H2 delivered by the plasma in the boxes, which could inadvertently lead to detachment. Details of the geometry, simulations, and possible diagnostic techniques are presented.

divertor↗

Developments on two lithium vapor-box linear test-stand experiments

The lithium vapor-box divertor is a possible fusion power exhaust solution.It uses condensation pumping to create a gradient of vapor density in a divertor slot; this should allow a stable detachment front without active feedback.As initial explorations of the concept, two test stands which take the form of three connected cylindrical stainless steel boxes are being developed: one without plasma at PPPL, to test models of lithium evaporation and flow; and one for the linear plasma device Magnum-PSI (at DIFFER in Eindhoven, The Netherlands) to test the ability of a lithium vapor cloud to induce volumetric detachment and redistribute the plasma power.The first experiment uses boxes with diameters of 6 cm, joined by apertures with diameters of 2.2 cm. Up to 1 g of Li is placed in one box, which is heated to up to 600 degrees C. The Li evaporates, then flows to and condenses in the two other, cooler boxes over several minutes. The quantity of Li transported is assessed by weighing the boxes before and after the heating cycle, and is compared to the quantity predicted to flow for the box at its measured temperature using a Direct Simulation Monte Carlo code, SPARTA. With good experimental conditions, the two values agree to within 15%.The experiment on Magnum-PSI is in the conceptual design stage.The design is assessed by simulations using the code B2.5-Eunomia.They show that when the hydrogen-ion plasma beam, with n_e = 4e20 per cubic meter, T_e = 1.5 eV, and r = 1 cm, is passed through a 16 cm long, 12 Pa, 625 degree C Li vapor cloud, the plasma heat flux and pressure on the target are significantly reduced compared to the case without Li.With the Li present, the plasma is cooled by excitation of Li neutrals followed by radiation until it volumetrically recombines, lowering the heat flux from 3.7 MW/m^2 to 0.13 MW/m^2, and the pressure is reduced by 93%, largely by collisions of hydrogen ions with neutral Li.

divertor↗

Erosion and re-deposition of lithium and boron coatings under high-flux plasma bombardment

Lithium and boron coatings are applied to the walls of many tokamaks to enhance performance and protect the underlying substrates. Li and B-coated high-Z substrates are planned for use in NSTX-U and are a candidate plasma-facing component (PFC) for DEMO. However, previous measurements of Li evaporation and thermal sputtering on low-flux devices indicate that the Li temperature permitted on such devices may be unacceptably low. Thus it is crucial to characterize gross and net Li erosion rates under high-flux plasma bombardment. Additionally, no quantitative measurements have been performed of the erosion rate of a boron-coated PFC during plasma bombardment. A realistic model for the compositional evolution of a Li layer under D bombardment was developed that incorporates adsorption, implantation, and diffusion. A model was developed for temperature-dependent mixed-material Li-D erosion that includes evaporation, physical sputtering, chemical sputtering, preferential sputtering, and thermal sputtering. The re-deposition fraction of a Li coating intersecting a linear plasma column was predicted using atomic physics information and by solving the Li continuity equation. These models were tested in the Magnum-PSI linear plasma device at ion fluxes of 10^23-10^24 m^-2 s^-1 and Li surface temperatures less than 800 degrees C. Li erosion was measured during bombardment with a neon plasma that will not chemically react with Li and the results agreed well with the erosion model. Next the ratio of the total D fluence to the areal density of the Li coating was varied to quantify differences in Li erosion under D plasma bombardment as a function of the D concentration. The ratio of D/Li atoms was calculated using the results of MD simulations and good agreement is observed between measurements and the predictions of the mixed-material erosion model. Li coatings are observed to disappear from graphite much faster than from TZM Mo, indicating that fast Li diffusion into the bulk graphite substrate occurred, as predicted. Li re-deposition fractions very close to unity are observed in Magnum-PSI, as predicted by modeling. Finally, predictions of Li coating lifetimes in the NSTX-U divertor are calculated. The gross erosion rate of boron coatings was also measured for the first time in a high-flux plasma device.

liquid metals↗

Electromagnetic Torque in Tokamaks with Toroidal Asymmetries

Lithium and boron coatings are applied to the walls of many tokamaks to enhance performance and protect the underlying substrates. Li and B-coated high-Z substrates are planned for use in NSTX-U and are a candidate plasma-facing component (PFC) for DEMO. However, previous measurements of Li evaporation and thermal sputtering on low-flux devices indicate that the Li temperature permitted on such devices may be unacceptably low. Thus it is crucial to characterize gross and net Li erosion rates under high-flux plasma bombardment. Additionally, no quantitative measurements have been performed of the erosion rate of a boron-coated PFC during plasma bombardment. A realistic model for the compositional evolution of a Li layer under D bombardment was developed that incorporates adsorption, implantation, and diffusion. A model was developed for temperature-dependent mixed-material Li-D erosion that includes evaporation, physical sputtering, chemical sputtering, preferential sputtering, and thermal sputtering. The re-deposition fraction of a Li coating intersecting a linear plasma column was predicted using atomic physics information and by solving the Li continuity equation. These models were tested in the Magnum-PSI linear plasma device at ion fluxes of 10^23-10^24 m^-2 s^-1 and Li surface temperatures less than 800 degrees C. Li erosion was measured during bombardment with a neon plasma that will not chemically react with Li and the results agreed well with the erosion model. Next the ratio of the total D fluence to the areal density of the Li coating was varied to quantify differences in Li erosion under D plasma bombardment as a function of the D concentration. The ratio of D/Li atoms was calculated using the results of MD simulations and good agreement is observed between measurements and the predictions of the mixed-material erosion model. Li coatings are observed to disappear from graphite much faster than from TZM Mo, indicating that fast Li diffusion into the bulk graphite substrate occurred, as predicted. Li re-deposition fractions very close to unity are observed in Magnum-PSI, as predicted by modeling. Finally, predictions of Li coating lifetimes in the NSTX-U divertor are calculated. The gross erosion rate of boron coatings was also measured for the first time in a high-flux plasma device.

liquid metals↗

Suppressed gross erosion of high-temperature lithium via rapid deuterium implantation

Lithium-coated high-Z substrates are planned for use in the NSTX-U divertor and are a candidate plasma facing component (PFC) for reactors, but it remains necessary to characterize the gross Li erosion rate under high plasma fluxes (>10 23 m -2 s -1 ), typical for the divertor region. In this work, a realistic model for the compositional evolution of a Li/D layer is developed that incorporates first principles molecular dynamics (MD) simulations of D diffusion in liquid Li. Predictions of Li erosion from a mixed Li/D material are also developed that include formation of lithium deuteride (LiD). The erosion rate of Li from LiD is predicted to be significantly lower than from pure Li. This prediction is tested in the Magnum-PSI linear plasma device at ion fluxes of 10 23 -10 24 m -2 s -1 and Li surface temperatures. ≤800 °C. Li/LiD coatings ranging in thickness from 0.2 to 500 μm are studied. The dynamic D/Li concentrations are inferred via diffusion simulations. The pure Li erosion rate remains greater than Langmuir Law evaporation, as expected. For mixed-material Li/LiD surfaces, the erosion rates are reduced, in good agreement with modelling in almost all cases. Lastly, these results imply that the temperature limit for a Li-coated PFC may be significantly higher than previously imagined.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Modeling and experiments on differential pumping in linear plasma generators operating at high gas flows

The direct simulation Monte Carlo (DSMC) method was used to investigate the efficiency of differential pumping in linear plasma generators operating at high gas flows. Skimmers are used to separate the neutrals from the plasma beam, which is guided from the source to the target by a strong axial magnetic field. In this way, the neutrals are prevented to reach the target region. The neutral flux to the target must be lower than the plasma flux to enable ITER relevant plasma-surface interaction (PSI) studies. It is therefore essential to control the neutral gas dynamics. The DSMC method was used to model the expansion of a hot gas in a low pressure vessel where a small discrepancy in shock position was found between the simulations and a well-established empirical formula. Two stage differential pumping was modeled and applied in the linear plasma devices Pilot-PSI and PLEXIS. In Pilot-PSI a factor of 4.5 pressure reduction for H{sub 2} has been demonstrated. Both simulations and experiments showed that the optimum skimmer position depends on the position of the shock and therefore shifts for different gas parameters. The shape of the skimmer has to be designed such that it has a minimum impact on the shock structure. A too large angle between the skimmer and the forward direction of the gas flow leads to an influence on the expansion structure. A pressure increase in front of the skimmer is formed and the flow of the plasma beam becomes obstructed. It has been shown that a skimmer with an angle around 53 deg. gives the best performance. The use of skimmers is implemented in the design of the large linear plasma generator Magnum-PSI. Here, a three stage differentially pumped vacuum system is used to reach low enough neutral pressures near the target, opening a door to PSI research in the ITER relevant regime.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Overview of Liquid-Metal PFC R&D at the University of Illinois Urbana-Champaign

The design and implementation of future flowing liquid-lithium plasma-facing components (LLPFCs) will be dependent on several factors. Of course, one of the most important is the need to be able to deal with high heat fluxes incident on the surface of the LLPFCs, but there are also several other important liquid-metal behaviors that have been identified for their critical impact on the feasibility of a LLPFC. One of these is the ability to constantly wet 100% of the plasma-facing component area and the best way to achieve that. Another key point is knowing and understanding the erosion and corrosion of the surfaces subject to a flowing liquid-lithium system and the ability for hydrogen and helium uptake by the system. The Center for Plasma Material Interactions (CPMI) has been tasked with looking at these various issues. The Mock-up Entry module for EAST device was used to investigate wetting and erosion effects and to design a suitable distribution and collection system with a liquid-lithium loop. The vapor shielding effects of lithium on the surface were also modeled and studied. A model coupling CRANE, an open-source global reaction network solver, and Zapdos, a plasma transport solver, is being developed to better understand the dynamics of the vapor cloud. Experiments on the Magnum-PSI at the Dutch Institute for Fundamental Energy Research have been carried out to study the vapor shielding effect and obtain experimental benchmarks to verify the model. Also, initial experiments using the Hybrid Illinois Device for Research and Applications have been performed to understand the pumping effects of lithium on helium. Experiments with a drop of liquid lithium (~100 mg) into a helium plasma have shown the ability of lithium to take out the cold recycling helium gas as well as hydrogen and oxygen impurity gases. The improvement in plasma performance was significant, and further understanding of this effect will have impacts on how future LLPFCs will be designed. Further investigation into the exact mechanism for helium pumping by lithium needs to be performed in the future. Finally, this paper presents a summary of the results obtained at the CPMI.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Machine learning aided line intensity ratio method for helium–hydrogen mixed recombining plasmas

The helium line intensity ratio (LIR) with the help of a collisional radiative (CR) model has long been used to measure the electron density, n e , and temperature, T e , and its potential and limitations for fusion applications have been discussed. However, it has been reported that the CR model approach leads to deviations in helium–hydrogen mixed plasmas and/or recombining plasmas. In this study, a machine learning (ML) aided LIR method is used to measure n e and T e from spectroscopic data of helium–hydrogen mixed recombining plasmas in the divertor simulator Magnum-PSI. To analyze mixed plasmas, which have more complex spectral shapes, the spectroscopy data were used directly for training instead of separating the intensities of each line. Finally, it is shown that the ML approach can provide a robust and simpler analysis method to deduce n e and T e from the visible emissions in helium–hydrogen mixed plasmas.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Robust impurity detection and tracking for tokamaks

A robust impurity detection and tracking code, able to generate large sets of dust tracks from tokamak camera footage, is presented. This machine learning–based code is tested with cameras from the Joint European Torus, Doublet-III-D, and Magnum-PSI and is able to generate dust tracks with a 65 – 100 % classification accuracy. Moreover, the number dust particles detected from a single camera shot can be up to the order of 1000. Several areas of improvement for the code are highlighted, such as generating more significant training data sets and accounting for selection biases. Finally, although the code is tested with dust in single two-dimensional camera views, it could easily be applied to multiple-camera stereoscopic reconstruction or nondust impurities.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗