(U) Marker Lagrangian Simulations using Geometry from CAD Assembly Files [Slides]

The Eulerian code PAGOSA now contains an option for the forward time integration of any user selected material in the Lagrangian frame of reference. This option is accomplished using a Multifield version of Brackbill’s FLIP plus Sulsky’s MPM. FLIP+MPM is a Marker Lagrangian scheme that is not to be confused with well known Grid Lagrangian schemes. This Marker Lagrangian method allows materials to undergo completely arbitrary deformation, up to and including fracture and separation. Using this option makes PAGOSA into a mixed frame simulation tool such that fluids can be integrated in the Eulerian frame and solids integrated in the Lagrangian frame. Boundaries between the fields are said to be ’immersed’ in the computational domain, and their nature is formulated using Multifield Theory. Each Marker in a field of FLIP+MPM material tracks the thermodynamic state of a small (but finite) piece of mass. Initiation of the Markers using the geometry and material information from CAD Assembly files is the subject of the talk. The ease and speed with which the dynamics of the assembly can be studied is demonstrated.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Simultaneous compression and opacity data from time-series radiography with a Lagrangian marker

Time-resolved radiography can be used to obtain absolute shock Hugoniot states by simultaneously measuring at least two mechanical parameters of the shock, and this technique is particularly suitable for one-dimensional converging shocks where a single experiment probes a range of pressures as the converging shock strengthens. However, at sufficiently high pressures, the shocked material becomes hot enough that the x-ray opacity falls significantly. Additionally, if the system includes a Lagrangian marker such that the mass within the marker is known, this additional information can be used to constrain the opacity as well as the Hugoniot state. In the limit that the opacity changes only on shock heating, and not significantly on subsequent isentropic compression, the opacity of the shocked material can be determined uniquely. More generally, it is necessary to assume the form of the variation of opacity with isentropic compression or to introduce multiple marker layers. Alternatively, assuming either the equation of state or the opacity, the presence of a marker layer in such experiments enables the non-assumed property to be deduced more accurately than from the radiographic density reconstruction alone. An example analysis is shown for measurements of a converging shock wave in polystyrene at the National Ignition Facility.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

An analysis of the spatio-temporal resolution of the immersed boundary method with direct forcing

The immersed boundary method (IBM) with direct forcing is very popular in the simulation of rigid particulate flows. In the IBM, an interaction force is introduced at the interface between fluid and particle in order to approximate the no-slip boundary condition. The interaction force is calculated through dividing the velocity difference (or error) between fluid and particle at the interface by the time step. Here, a dynamic equation for the velocity difference is derived. Additionally, analyses on the dynamic equation provide a few new findings: (i) The interaction force is the solution of a least-squares error problem, with the direct implication that the Lagrangian marker distribution has no effect on the large scale flow structure once the distribution of Lagrangian markers become saturated along the interface (i.e., each marker remains properly correlated with all its neighbors); (ii) The Lagrangian volume-weight is a relaxation factor to control how fast the velocity error decays to the ideal value of zero; (iii) The optimal choice of the Lagrangian volume-weight is the largest value permissible by a stability condition. A comprehensive convergence analysis with regard to the spatial and temporal resolution is presented for the velocity error and also for the shear-stress and surface pressure. In three simple canonical problems, it is analytically and numerically shown that the IBM results converge to the theoretical solutions obtained with precise imposition of no-slip and no-penetration boundary conditions. It is observed that it is not necessary to match the Lagrangian marker volume-weight to that of the local Eulerian cell volume and in fact this matching leads to lower than optimal computational efficiency. However, it is found that extremely high Eulerian grid resolution and small time step have to be used to obtain high precision simulation results. Especially, the time step should be inversely proportional to the particle Reynolds number for low Reynolds number flows. For high frequency oscillation problems, the grid size needs to be reduced by a factor of the square root of the frequency, and the time step to be reduced by a factor of the frequency. The theoretical findings here can be used to alleviate the technical difficulties in simulating non-spherical particles by not requiring the Lagrangian marker distribution to match the Eulerian grids and also in the implementation of IBM on non-uniform Eulerian grids. The present work also provides simple practical guidance on the choice of temporal and spatial resolution so as to control the simulation error a priori.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Density reconstruction in convergent high-energy-density systems using x-ray radiography and Bayesian inference

X-ray radiography is a technique frequently used to diagnose convergent high-energy-density (HED) systems, such as inertial confinement fusion implosion, and provides unique information that is not available through self-emission measurements. In this work, we investigate the scope and limits of that information using a radiography simulation combined with the Bayesian inference workflow. The accuracy of density reconstruction from simulated radiographs of spherical implosions driven with 27 kJ laser energy is assessed, including the increase or decrease in accuracy due to the addition of Lagrangian marker layers, Poisson noise, and improved prior information. This work is the first to present the full uncertainty distributions inferred from radiography analysis in HED systems and demonstrates the importance of constructing the full posterior probability density, as opposed to a point estimate, due to the modal structure of the likelihood surface introduced by typical experimental noise sources. This general methodology can be used both for robust analysis of radiographic data and for an improved design of radiography experiments by modeling the full experimental system.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development of a Filtered CFD-DEM Drag Model with Multiscale Markers Using an Artificial Neural Network and Nonlinear Regression

Here, the accuracy of coarse-grained Euler-Lagrangian simulations of fluidized beds heavily depends on the mesoscale drag models to account for the influences of the unresolved sub-grid structures. Traditional filtered drag models are regressed with mesoscale markers such as voidage and slip velocities. In this research, a filtered drag was regressed with both mesoscale and macro-scale markers using fine grid Computational Fluid Dynamics - Discrete Element Method (CFD-DEM) simulations. The traditional non-linear regression method was compared with machine learning regression using an Artificial Neural Network (ANN) implemented in PyTorch and coupled with MFiX. The new drag showed higher accuracy than the Wen-Yu drag and another filtered drag derived from the two-fluid model. The nonlinear regression shows slightly better results than ANN regression in cases with similar R 2 values. The utilization of the gas inlet velocity as an additional macro-scale marker reduced the errors by up to 55.3% in the tested cases.