Search NASA⌕ Search

SEARCH · Search NASA

Results for “Marx generator”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

0D, 1D, 2D, and 3D simulations of an idealized coaxial impedance-matched Marx generator

We have conducted 0D, 1D, 2D, and 3D simulations of an idealized coaxial impedance-matched Marx generator (IMG) []. The 0D calculations were conducted with a four-element circuit model; the 1D, 2D, and 3D calculations were conducted with highly resolved, fully electromagnetic representations. The IMG consists of 30 stages distributed axially and connected electrically in series. Each stage is powered by two bricks separated by 180° and connected electrically in parallel. Each brick comprises two opposite-polarity capacitors in series with a single switch. The bricks drive an internal impedance-matched coaxial transmission line terminated by a resistive load. The simulations neglect effects due to the switch-triggering circuit, the capacitor-charging circuit, external conducting boundaries, and reactive components of the load. We find dimensionality does not significantly affect the electrical power delivered by the IMG to its load: peak load powers estimated by the 0D, 1D, 2D, and 3D simulations agree to within 1%. The 3D calculations demonstrate that electromagnetic power radiated by the bricks, and axial gaps between stages, reduces the peak load power by less than ∼ 1 % . Each simulation assumes the load impedance is 34% above that at which the load power is maximized. Operating an IMG with such an overmatched load offers several advantages while decreasing the peak load power by only 2%. The 0D, 1D, 2D, and 3D models outlined herein could be adapted to assess computationally competing IMG designs, and conduct a variety of numerical IMG experiments, an IMG is constructed. Published by the American Physical Society 2024

43 PARTICLE ACCELERATORS↗

Linear Transformer Drivers for Z-pinch Based Propulsion

The MSFC/UAH team has been developing of a novel power management and distribution system called a Linear Transformer Driver (LTD). LTD's hold the promise of dramatically reducing the required mass to drive a z-pinch by replacing the capacitor banks which constitute half the mass of the entire system. The MSFC?UAH tea, is developing this technology in hope of integrating it with the Pulsed Fission Fusion (PuFF) propulsion concept. High-Voltage pulsed power systems used for Z-Pinch experimentation have in the past largely been based on Marx Generators. Marx generators deliver the voltage and current required for the Z-Pinch, but suffer from two significant drawbacks when applied to a flight system: they are very massive, consisting of high-voltage capacitor banks insulated in oil-filled tanks and they do not lend themselves to rapid pulsing. The overall goal of Phase 2 is to demonstrate the construction of a higher voltage stack from a number of cavities each of the design proven in Phase 1 and to characterize and understand the techniques for designing the stack. The overall goal of Phase 3 is to demonstrate the feasibility of constructing a higher energy cavity from a number of smaller LTD stacks, to characterize and understand the way in which the constituent stacks combine, and to extend this demonstration LTD to serve as the basis for a 64 kJ pulse generator for Z-Pinch experiments.

Adams, Robert↗

Description of a new full scale lightning simulation facility

A lightning test facility has been constructed in Utah, and the facility has initially been used to test and certify solid rocket motor (SRM) segment shipping containers. The simulator equipment consists of a 17-stage 1.7 MV Marx generator and three current generators. The performance of the Marx is enhanced by use of a distributed peaking capacitor to produce maximum dl/dt's in excess of 4 x 10 to the 11th Amps/sec into large test objects. The current generators consist of the following: (1) a 200 KA underdamped 500 kilojoule high current bank, (2) a critically damped intermediate current bank and (3) an over damped continuing current bank. Total charge transfer for these banks is 270 Coulombs with an action integral in excess of 8 x 10 to the 6th sq Amps-sec. Representative results for the simulator and SRM segment shipping containers are presented.

Papazian, Peter B.↗

Microsecond Electron Beam Source with Electron Energy Up to 400 Kev and Plasma Anode

A new high-power source of electrons with plasma anode for producing high-current microsecond electron beams with electron energy up to 400 keV has been developed, manufactured, and put in operation. To increase the cross section and pulse current duration of the beam, a multipoint explosive emission cathode is used in the electron beam source, and the beam is formed in an applied external guiding magnetic field. The Marx generator with vacuum insulation is used as a high-voltage source. Electron beams with electron energy up to 300–400 keV, current of 5–15 kA, duration of 1.5–3 μs, energy up to 4 kJ, and cross section up to 150 cm{sup 2} have been produced. The operating modes of the electron beam source are realized in which the applied voltage is influenced weakly on the current. The possibility of source application for melting of metal surfaces is demonstrated.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Load dynamics of double planar foil liners and double planar wire arrays on the UM MAIZE LTD generator

In previous studies using the University of Nevada, Reno's (UNR's) high-impedance Zebra Marx generator (1.9 Ω, 1.7 MA, 100 ns), Double Planar Wire Arrays (DPWAs) proved to be excellent radiators, and Double Planar Foil Liners (DPFLs) proved useful for future inertial confinement fusion applications. This article presents the results of joint UNR/UM (University of Michigan) experiments with aluminum (Al) DPWAs, Al DPFLs, and tungsten (W) DPWAs using UM's Michigan Accelerator for Inductive Z-Pinch Experiments (MAIZE) generator, a low-impedance Linear Transformer Driver (LTD) (0.1 Ω, 0.5–1 MA, and 100–250 ns). The main goals of this study were twofold: the first was a pioneering effort to test whether a relatively heavy Al DPFL could successfully be imploded on a low-impedance university-scale LTD like the MAIZE generator, and, if so, to analyze the results and make comparisons to the optimized, lighter DPWA configurations that have been previously studied. The DPWAs consisted of two planes of micrometer-scale diameter Al or W wires, while the DPFLs consisted of two planes of micrometer-scale thickness Al foils. Diagnostics include filtered Si-diodes, an absolutely calibrated filtered PCD, x-ray pinhole cameras, spectrometers, and gated optical self-emission imaging. The implosion dynamics and radiative properties of Al DPWAs and DPFLs and W DPWAs on the MAIZE LTD are discussed and compared. Time-dependent load inductance calculations derived from measurements of the load current and a MAIZE circuit model provide a relative measurement of pinch strength. In experiments on MAIZE, W planar wire arrays exhibited a higher peak load inductance throughout the pinch than Al DPWAs and DPFLs, while x-ray pulses from Al DPFLs had the longest emission duration.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Experiments to Quantify the Shielding Efficacy of Materials to be Implemented for Portable Shielding Enclosures that Adequately Mitigate EMI from Lighting Attachment Events

Mitigating electric and magnetic fields induced by lightning strike events is critical for the security and longevity of electrical components. Electromagnetic interference originating from a lightning strike is categorized into the low to medium frequency ranges, commonly referred to as the “magnetic coupling” regime. This low-frequency characteristic brings about the problem of shielding magnetic flux lines. Such shielding can be accomplished with highly conductive materials via the generation of eddy currents or by diverting the flux lines using materials with a large relative permeability. The shielding effectiveness of materials with varying thicknesses and geometry are tested using a pulse forming network having comparable characteristics to a scaled lighting strike. A four-stage Marx generator with a peak current of ~33 kA and a risetime of 1.4 μs is used as the pulse forming network to emulate the scaled electric and magnetic fields. The data collected from these experiments provide information and techniques that can be implemented into the design of a portable, deployable shielding enclosure.

61 RADIATION PROTECTION AND DOSIMETRY↗

Analysis of Cygnus Electrical Signals

The United States initiated the Subcritical Experiment (SCE) program to support a stockpile stewardship mission shortly after the 1992 moratorium on underground nuclear testing was established. Many SCE’s are conducted at the Nevada National Security Site (NNSS) in Nevada. Cygnus is a high-energy radiation generating device (RGD) located and operated at the NNSS and is a primary diagnostic for the SCE program. The Cygnus Dual Beam Radiographic Facility consists of two identical radiographic sources, Cygnus 1 and Cygnus 2. From creation of the high power V-I drive to energy transport and X-ray conversion at the rod-pinch diode, the Cygnus machines utilize the following components: oil-filled Marx generator, water-filled pulse-forming line (PFL), water-filled coaxial transmission line (CTL), three-cell vacuum induction voltage adder (IVA), and rod-pinch diode. The diode pulse has the following electrical specifications: 2.25 MV, 60 kA, 60 ns. Each source has the following X-ray specifications: 1 mm diameter, 4 rad at 1 m, and 50 ns radiation pulse. SCEs are both single-event and high-value; therefore, a high level of performance in reliability and reproducibility are key issues of Cygnus. Prior to executing such a SCE, there are a formidable number of shots (e.g., each of the two Cygnus RGDs charging and discharging properly into the rod-pinch diode load) that must be executed to determine reliability and reproducibility of the Cygnus RGDs. For every shot on Cygnus, voltages and currents along the machine are recorded and analyzed. In this paper we summarize attributes of the voltage and current waveforms at different locations using distribution plots. These distribution plots are used to quantify the reliability and reproducibility for Cygnus. This analysis methodology will provide a standard to trouble shoot results of individual Cygnus shots, and also to monitor long term Cygnus performance. Accordingly, this type of extensive analysis will contribute to optimized Cygnus performance on SCEs.

42 ENGINEERING↗