Ultralightweight Power System for Human-Portable Linac-Based X-Ray Sources

Industrial human-portable X-ray sources are widely used by security, nuclear safeguard, and defense agencies. However, the employed sources have significant energy, dose, size, weight, and power (SWaP) limitations, greatly affecting their practical application. RF linear accelerators (linacs) can serve as a flexible, reliable, and robust type of X-ray source if they can match the size, weight, cost, and imaging performance requirements of conventional ones. One of the most critical elements affecting these parameters is the high-voltage pulsed power supply system or modulator, which can make the largest contribution to the total weight and dimensions of the accelerator. Here, in this article, we present the design and demonstration results of a novel ultra lightweight power system based on a 24-kV solid-state Marx modulator for a hand-portable 0.15–2.0-MeV Ku -band linac-based X-ray source.

47 OTHER INSTRUMENTATION↗

Radioisotope replacement with compact electron linear accelerators

The replacement of radioactive sources with alternative technologies has been identified as a priority by international authorities, due to the risk of accidents and diversion by terrorists for use in Radiological Dispersal Devices. Many of these sources can be replaced with the X-rays produced by electron beams accelerated to MeV energies. However, the size, weight and costs of electron linacs must be significantly reduced to be considered for radioisotope replacement. RadiaBeam Technologies, LLC is developing a series of inexpensive compact electron accelerators in the 1–10 MeV range for radioisotope replacement such as Ir-192, Cs-137 and Co-60 for various applications. The dramatic level of miniaturization and cost-reduction was achieved thanks to the implementation of such innovative technologies as high-frequency magnetrons, split accelerating structure fabrication technology and solid-state Marx modulators. Here, in this paper, we overview RadiaBeam's compact linac developments, discuss the enabling technologies, and report on the current progress.

43 PARTICLE ACCELERATORS↗

Ku-band electron linac for battery-powered hand-portable 2-MeV X-ray generator

X-ray generators, producing radiation in MeV range, are a critical tool for radiography, non-destructive testing and security applications. Field operation of such source requires them to be hand-portable, autonomous and allow parameter adjustability. RF linear accelerators can serve as a flexible, reliable, and robust radiation generator alternative to dangerous radioisotopes and bulky betatrons that are currently used for field radiography if their size, weight, cost, and imaging performance are matched to these sources. Here, in this paper, we present the design and test results of a 2 MeV Ku-band electron linac for a hand-portable X-ray generator system for field radiography being developed by RadiaBeam. The dramatic scale of miniaturization and cost-reduction is achieved thanks to the implementation of innovative technologies such as air-cooled Ku-band air-traffic control magnetrons, a split accelerating structure fabrication technique, and solid-state Marx modulators. This paper presents the design of the first prototype of the accelerator, its operation from Li-Ion batteries, as well as high-power and beam measurements.

43 PARTICLE ACCELERATORS↗

LINAC Electrical Cabinets - Structural Analysis

Along LINAC s downstream path is a floor containing various cabinets above the LINAC. Of the dozens of cabinets are 4 specific cabinet types: PNF Modulator, PNF Power Supply, Water Skid, and Marx. Each of these cabinets may contain some of the various contents that include electronics, wiring, pipelines, circuits, and conduits. Lab Technicians perform maintenance and inspections of the cabinets and need to access every part, including the top section that is subject to the weight of the technician standing on top. To ensure the cabinet is structurally safe, a CAD model will be developed for each cabinet and a Finite Element Analysis (FEA) will be performed on each cabinet to confirm it is safe to stand on.

Blas, Efren↗

LINAC Electrical Cabinets - Structural Analysis

Along LINAC s downstream path is a floor containing various cabinets above the LINAC. Of the dozens of cabinets are 4 specific cabinet types: PFN (pulse-forming network) Module, PFN Power Supply, Water Skid, and Marx. Each of these cabinets may contain some of the various contents that include electronics, wiring, pipe lines, circuits, conduits. In addition, high voltage and flowing fluids are also present within the cabinets. Occasionally, Lab Technicians perform maintenance and inspections of the cabinets and need to access every part, including the top section that is subject to the weight of the technician standing on top. To ensure the cabinet is structurally safe, a CAD model will be developed for each cabinet and a Finite Element Analysis (FEA) will be performed on each cabinet to confirm it is safe to stand on.

Blas, Efren↗

LINAC Electrical Cabinet - Structural Analysis

Along LINAC s downstream path is a floor containing various cabinets above the LINAC. Of the dozens of cabinets are 4 specific cabinet types: PFN (pulse-forming network) Module, PFN Power Supply, Water Skid, and Marx. Each of these cabinets may contain some of the various contents that include electronics, wiring, circuits, and conduits. In addition, high voltage and low conductivity water (LCW) piping are also present within the cabinets. Occasionally, Lab Technicians perform maintenance and inspections of the cabinets and need to access every part, including the top section that is subject to the weight of the technician standing on top. To ensure the cabinet is structurally safe, a CAD model was developed for each cabinet and a Finite Element Analysis (FEA) was performed on each cabinet to confirm it is safe to stand on.

Blas, Efren↗

K-Modules: Capacitive Energy Modules for Pulsed Power Applications [Slides]

K-Modules are modules containing an assembly of capacitors. The modules are meant to be daisy-chained to form a Marx bank (bank of capacitors). Discharging the bank produces a high voltage, high current pulse, that when coupled to an X-ray or electron beam tube, generates X-rays or an intense electron beam. Number of modules in the stack can be varied to meet different pulsed power applications. The technology addresses the need for an alternate provider with a new, robust design. The technology has the potential to extend the life of the X-ray radiography program in the country.

43 PARTICLE ACCELERATORS↗

K-Modules

K-Modules are capacitive energy modules designed to be stacked together to form a capacitor bank (aka a Marx bank). Discharging the stack produces a single, high voltage, high current pulse that when coupled to an X-ray (or electron) tube, produces energetic X-rays (or an intense electron beam, E-beam). The energetic X-rays are used in Flash X-ray Radiography (FXR), a technique to image objects moving at extremely high speed to measure their speed, shape and internal density profiles. The images help validate computer models for materials behavior under extreme pressure and temperature. FXR is a technology critical to dynamic experiments for the national security mission, and most users are DOE and DOD labs. Febetrons, the X-ray generating devices, are used at these sites and rely on capacitive energy modules for their operation. A stack of the newly developed K-modules will significantly extend the capabilities of these Febetrons

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Charger 1: A New Facility for Z-Pinch Research

Charger 1 is a multipurpose pulsed power laboratory located on Redstone Arsenal, with a focus on fusion propulsion relevant experiments involving testing z-pinch diodes, pulsed magnetic nozzle and other related physics experiments. UAH and its team of pulsed power researchers are investigating ways to increase and optimize fusion production from Charger 1. Currently the team has reached high-power testing. Due to the unique safety issues related to high power operations the UAH/MSFC team has slowed repair efforts to develop safety and operations protocols. The facility is expected to be operational by the time DZP 2017 convenes. Charger 1 began life as the Decade Module 2, an experimental prototype built to prove the Decade Quad pinch configuration. The system was donated to UAH by the Defense Threat Reduction Agency (DRTA) in 2012. For the past 5 years a UAH/MSFC/Boeing team has worked to refurbish, assemble and test the system. With completion of high power testing in summer 2017 Charger 1 will become operational for experimentation. Charger 1 utilizes a Marx Bank of 72 100-kV capacitors that are charged in parallel and discharged in series. The Marx output is compressed to a pulse width of approximately 200 ns via a pulse forming network of 32 coaxial stainless steel tubes using water as a dielectric. After pulse compression a set of SF6 switches are triggered, allowing the wave front to propagate through the output line to the load. Charger 1 is capable of storing 572-kJ of energy and time compressing discharge to less than 250 ns discharge time producing a discharge of about 1 TW of discharge with 1 MV and 1 MA peak voltage and current, respectively. This capability will be used to study energy yield scaling and physics from solid density target as applied to advanced propulsion research.

Taylor, Brian↗

Cyote-attack Chain Estimator

Attack Chain Estimator (ACE) Application Overview The Attack Chain Estimator (ACE) Application is a sophisticated tool designed for the ingestion, classification, sequencing, and enrichment of cybersecurity threat reports. This application leverages advanced machine learning models and extensive historical data to provide comprehensive insights into cyber threats, specifically targeting Industrial Control Systems (ICS). Purpose The primary functions of the ACE Application include: Ingestion of Cybersecurity Threat Reporting: Capable of ingesting text-based threat reports in markdown or text file format. Supports ingestion of structured data from other sources in STIX/JSON format. Classification of Report’s Text-Based Events: Utilizes a DeBERTa classifier, specifically trained on cybersecurity data, to map the events to MITRE ATT&CK for ICS Tactics and Techniques. Classification is performed using multiple Jupyter notebooks and machine learning workflows hosted as FastAPI microservices: regex_data deberta_base_35_train_hft_classifier_mlflow.ipynb hft_regex_classifier_mlflow.ipynb param_train_hft_classifier_mlflow.ipynb regex_tactic_tech.ipynb Ordering of Tactics, Techniques, and Observable Events: Sequences the identified tactics, techniques, and events to form a coherent attack chain. Enrichment with Historical Attack Chain Details: Enhances the attack chain with details from historical attacks using a Markov model developed from CyOTE Precursor Analysis Report data. The Markov model is available as a FastAPI endpoint for seamless integration. Enrichment with Adversary Emulation Capabilities Data: Integrates adversary emulation capabilities data using MITRE Caldera for OT adversary abilities UUIDs. Export of Output Files: Provides options to export the enriched attack chain in JSON or CSV formats. Routing of Output to Other Applications: Facilitates routing of output to various platforms and applications, including: Threat Intelligence Platforms COREII Scout for Threat Intelligence Analysis COREII Modeling and Simulation for Adversary Emulation Technical Description The ACE Application is an advanced cybersecurity tool designed to provide detailed threat analysis and sequence generation. It is built on a robust architecture that integrates natural language processing, machine learning, and historical data modeling. Key Components: Data Ingestion Module: Handles the input of threat reports and data from various formats, ensuring flexibility in data sources. Classification Engine: Employs DeBERTa-based classifiers hosted as FastAPI microservices to analyze and classify threat report events in accordance with the MITRE ATT&CK framework for ICS. Sequence Generator: Orders the classified events into a logical attack chain, providing clear insight into the sequence of tactics and techniques used in the threat. Enrichment Engine: Integrates historical data and adversary emulation capabilities to enhance the attack chain with valuable context and additional details. The historical data enrichment is powered by a Markov model, which is available as a FastAPI endpoint. Export and Routing Module: Facilitates the export of the enriched attack chain in multiple formats and routes the output to designated applications for further analysis or emulation.

Paul, Tony [Idaho National Laboratory (INL), Idaho↗

The simulated Indian monsoon: A GCM sensitivity study

A series of sensitivity experiments are conducted in an attempt to understand and correct deficiencies in the simulation of the seasonal mean Indian monsoon with a global atmospheric general circulation model. The seasonal mean precipitation is less than half that observed. This poor simulation in seasonal integrations is independent of the choice of initial conditions and global sea surface temperature data used. Experiments are performed to test the sensitivity of the Indian monsoon simulation to changes in orography, vegetation, soil, wetness, and cloudiness. The authors find that the deficiency of the model precipitation simulation may be attributed to the use of an enhanced orography in the integrations. Replacement of this orography with a mean orography results in a much more realistic simulation of Indian monsoon circulation and rainfall. Experiments with a linear primitive equation model on the sphere suggest that this striking improvement is due to modulations of the orographically forced waves in the lower troposphere. This improvement in the monsoon simulation is due to the kinematic and dynamical effects of changing the topography, rather than the thermal effects, which were minimal. The magnitude of the impact on the Indian monsoon of the other sensitivity experiments varied considerably, but was consistently less than the impact of using the mean orography. However, results from the soil moisture sensitivity experiments suggest a possibly important role for soil moisture in simulating tropical precipitation, including that associated with the Indian monsoon.

Fennessy, M. J.↗

Scattered–light–sheet microscopy with sub–cellular resolving power

Since its first demonstration over 100 years ago, scattering-based light-sheet microscopy has recently re-emerged as a key modality in label-free tissue imaging and cellular morphometry; however, scattering-based light-sheet imaging with subcellular resolution remains an unmet target to date. This is because related approaches inevitably superimpose speckle or granular intensity modulation on to the native subcellular features. Here, we addressed this challenge by deploying a time-averaged pseudo-thermalized light-sheet illumination. While pseudo-thermalizing the illumination sheet increased its lateral dimensions, we achieved subcellular resolving power at ultralow irradiance levels after image deconvolution. We validated this approach by imaging cytosolic carbon depots in yeast and bacteria with increased specificity and no staining. Altogether, we expect this scattering-based light-sheet microscopy approach will advance live single-cell imaging investigations by conferring low-irradiance and label-free operation towards eradicating phototoxicity.

59 BASIC BIOLOGICAL SCIENCES↗

Prediction and Evaluation of the Image of the WFIRST Coronagraph Pupil at the Shaped-Pupil Mask

To create a high contrast field of view with a shaped pupil coronagraph (SPC), the telescope pupil is imaged onto the shaped pupil mask, the shaped pupil mask is designed and fabricated through a design optimization based on a given pupil wavefront, and deformable mirrors (DM) in the coronagraph are modulated according to a nonlinear optimization procedure. Both the mask design optimization and the DM optimization require accurate knowledge of the image of the pupil at the shaped pupil plane for the calculation of Jacobians, and the evaluation of alignment tolerances. The shaped pupil coronagraphs demonstrated in the high contrast imaging testbed (HCIT) at JPL has heretofore assumed perfect imaging of the pupil onto the shaped pupil mask. Similarly, the design and performance modeling of the WFIRST CGI instrument makes the same assumption. In this paper we estimate and compare the image of the pupil mask at the shaped pupil plane in the case of the coronagraph testbed, and the image of the telescope pupil at the shaped pupil plane for the WFIRST CGI instrument. The estimated pupil images include field curvature and aberrations resulting from the layout of the parabolic mirror imaging system, which is optimized for the source image, not the image of the pupil. We also show the results of direct measurement of the image of the pupil mask at the shaped pupil plane in the coronagraph testbed.

Crowther, Blake↗