Search NASASearch

SEARCH · Search NASA

Results for “Mass”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Using System Mass (SM), Equivalent Mass (EM), Equivalent System Mass (ESM) or Life Cycle Mass (LCM) in Advanced Life Support (ALS) Reporting

The Advanced Life Support (ALS) has used a single number, Equivalent System Mass (ESM), for both reporting progress and technology selection. ESM is the launch mass required to provide a space system. ESM indicates launch cost. ESM alone is inadequate for technology selection, which should include other metrics such as Technology Readiness Level (TRL) and Life Cycle Cost (LCC) and also consider perfom.arxe 2nd risk. ESM has proven difficult to implement as a reporting metric, partly because it includes non-mass technology selection factors. Since it will not be used exclusively for technology selection, a new reporting metric can be made easier to compute and explain. Systems design trades-off performance, cost, and risk, but a risk weighted cost/benefit metric would be too complex to report. Since life support has fixed requirements, different systems usually have roughly equal performance. Risk is important since failure can harm the crew, but it is difficult to treat simply. Cost is not easy to estimate, but preliminary space system cost estimates are usually based on mass, which is better estimated than cost. Amass-based cost estimate, similar to ESM, would be a good single reporting metric. The paper defines and compares four mass-based cost estimates, Equivalent Mass (EM), Equivalent System Mass (ESM), Life Cycle Mass (LCM), and System Mass (SM). EM is traditional in life support and includes mass, volume, power, cooling and logistics. ESM is the specifically defined ALS metric, which adds crew time and possibly other cost factors to EM. LCM is a new metric, a mass-based estimate of LCC measured in mass units. SM includes only the factors of EM that are originally measured in mass, the hardware and logistics mass. All four mass-based metrics usually give similar comparisons. SM is by far the simplest to compute and easiest to explain.

Jones, Harry

Galaxy cluster matter profiles - I. Self-similarity, mass calibration, and observable-mass relation validation employing cluster mass posteriors

We present a study of the weak lensing inferred matter profiles ΔΣ(R) of 698 South Pole Telescope (SPT) thermal Sunyaev-Zel’dovich effect (tSZE) selected and MCMF optically confirmed galaxy clusters in the redshift range 0.25 < z < 0.94 that have associated weak gravitational lensing shear profiles from the Dark Energy Survey (DES). Rescaling these profiles to account for the mass dependent size and the redshift dependent density produces average rescaled matter profiles ΔΣ(R/R200c)/(ρcritR200c) with a lower dispersion than the unscaled ΔΣ(R) versions, indicating a significant degree of self-similarity. Galaxy clusters from hydrodynamical simulations also exhibit matter profiles that suggest a high degree of self-similarity, with RMS variation among the average rescaled matter profiles with redshift and mass falling by a factor of approximately six and 23, respectively, compared to the unscaled average matter profiles. We employed this regularity in a new Bayesian method for weak lensing mass calibration that employs the so-called cluster mass posterior P(M200|ζ̂, λ̂, z), which describes the individual cluster masses given their tSZE (ζ̂) and optical (λ̂, z) observables. This method enables simultaneous constraints on richness λ-mass and tSZE detection significance ζ-mass relations using average rescaled cluster matter profiles. We validated the method using realistic mock datasets and present observable-mass relation constraints for the SPT×DES sample, where we constrained the amplitude, mass trend, redshift trend, and intrinsic scatter. Our observable-mass relation results are in agreement with the mass calibration derived from the recent cosmological analysis of the SPT×DES data based on a cluster-by-cluster lensing calibration. Our new mass calibration technique offers a higher efficiency when compared to the single cluster calibration technique. We present new validation tests of the observable-mass relation that indicate the underlying power-law form and scatter are adequate to describe the real cluster sample but that also suggest a redshift variation in the intrinsic scatter of the λ-mass relation may offer a better description. In addition, the average rescaled matter profiles offer high signal-to-noise ratio (S/N) constraints on the shape of real cluster matter profiles, which are in good agreement with available hydrodynamical ΛCDM simulations. This high S/N profile contains information about baryon feedback, the collisional nature of dark matter, and potential deviations from general relativity.Key words: gravitational lensing: weak / galaxies: clusters: general / large-scale structure of Universe

79 ASTRONOMY AND ASTROPHYSICS

Checking It Twice: Using [C/N] Masses and Asteroseismic Masses as a Diagnostic of Mass Loss and Transfer on the Red Giant Branch

Red giants experience significant mass loss, but the mechanism is poorly understood. The surface [C/N] of red giants is correlated with birth mass but not directly impacted by mass loss. Exploiting this, we compare asteroseismic masses of red giants with the same [C/N] but different evolutionary states. We find bulk differences between stars at the beginning of the red giant branch (RGB) and in the subsequent evolutionary phase, the red clump, providing a direct constraint on the strength of net RGB mass loss in field stars. We find that net mass loss decreases with metallicity and mass, matching recent studies for field giants but contradicting expectations from the widely used Reimers’s mass-loss formula. We propose a mass- and metallicity-dependent Reimers’s η calibration that reproduces the empirical trends that we see. In addition, we identify 200 stars (3.12% of our sample) that are clear outliers from their population in these birth mass bins, which we believe are likely candidates for mass transfer events. These stars do not show any obvious discrepancies in abundances or binary properties from their counterparts. This population should be accounted for in Galactic archeological studies. Further follow-up is required to quantify their occurrence rate and origin.

Roberts, John D. [The Ohio State Univ., Columbus,

The mass-luminosity relation for stars of mass 1.0 to 0.08 solar mass

Mass-luminosity relations determined at IR wavelengths are presented for stars with masses 1.0 to 0.08 solar mass. Using IR speckle imaging techniques on a sample of nearby binaries, we have been able to concentrate on the lower main sequence, for which an accurate mass-luminosity calibration has remained problematic. In addition, the mass-visual luminosity relation for stars with 2.0-0.08 solar mass is produced by implementing new photometric relations linking V to JHK wavelengths for the nearby stars, supplemented with eclipsing binary information. These relations predict that objects with masses of about 0.08 solar mass have M(K) of about 10 and M(V) of about 18.

Henry, Todd J.

Evaluations for medium- and high-mass nuclei for FUSION applications

There is a renewed attention to nuclear fusion as a commercial source of carbon-free energy, however there are many scientific needs that must be addressed to enable the future success of fusion as an economical energy option. Among these is the proper description of the impact of radiation produced in the fusion vessel chamber and all other components of the reactor. In this work we will focus on the nuclear data needs to describe the interaction between primary and secondary neutron radiation and the medium- and high-mass nuclei commonly present in structural (such as stainless steel) and superconducting (e.g., electromagnets) materials.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS

Stellar Mass Calibrations for Local Low-mass Galaxies

The stellar masses of galaxies are measured from integrated light via several methods—however, few of these methods were designed for low-mass (M ⋆ ≲ 10 8 M ⊙ ) “dwarf” galaxies, whose properties (e.g., stochastic star formation, low metallicity) pose unique challenges for estimating stellar masses. In this work, we quantify the precision and accuracy at which stellar masses of low-mass galaxies can be recovered using UV/optical/IR photometry. We use mock observations of 469 low-mass galaxies from a variety of models, including both semi-empirical models (GRUMPY and UniverseMachine-SAGA) and cosmological baryonic zoom-in simulations (MARVELous Dwarfs and FIRE-2), to test literature color–M ⋆ /L relations and multiwavelength spectral energy distribution (SED) mass estimators. We identify a list of “best practices” for measuring stellar masses of low-mass galaxies from integrated photometry. We find that literature color–M ⋆ /L relations are often unable to capture the bursty star formation histories (SFHs) of low-mass galaxies, and we develop an updated prescription for stellar mass based on g − r color that is better able to recover stellar masses for the bursty low-mass galaxies in our sample (with ∼0.1 dex precision). SED fitting can also precisely recover stellar masses of low-mass galaxies, but this requires thoughtful choices about the form of the assumed SFH: Parametric SFHs can underestimate stellar mass by as much as ∼0.4 dex, while nonparametric SFHs recover true stellar masses with insignificant offset (−0.03 ± 0.11 dex). Finally, we also caution that noninformative (wide) dust attenuation priors may introduce M ⋆ uncertainties of up to ∼0.6 dex.

de los Reyes, Mithi A. C. [Amherst College, MA (Un

The Mass Index and Total Mass of the Geminid Meteoroid Stream as Found with Radar, Optical, and Lunar Impact Data

The Geminid meteor shower was observed in 2015 using the Western Meteor Physics Group’s Canadian Meteor Orbit Radar (CMOR), Marshall Space Flight Center’s (MSFC) eight wide-field optical cameras, and MSFC’s lunar impact monitoring. These observations allowed Geminid fluxes to be calculated in three unique mass-ranges, from 1.8 (exponent -4) grams to 30 grams. From these fluxes, a mass index of 1.68 plus or minus 0.04 is found, which is in excellent agreement with past Geminid mass indices such as 1.69 found by Blaauw et al using only radar data and 1.7 found by Arlt and Rendtel using visual data. This mass index, however, is found over five orders of magnitude of mass, which allows a higher level of confidence that this mass index holds over a large portion of the stream. Mass indices are an important quantity to be accurately measured for a shower, indicating the distribution of mass in a well-studied stream in which we know the parent body (3200 Phaethon), improving forecasts of the shower activity, and allow fluxes to be scaled to high and low masses. The quantities derived here, along with a profile of the Geminid meteor shower activity in 2015 from CMOR, permit the total Geminid mass the Earth encountered in 2015 to be found, along with a minimum total mass of the Geminid meteoroid stream. Attempts have been made in the past to measure the mass of meteoroid streams using Zenithal Hourly Rate (ZHR) profiles, but here this new and improved treatment uses empirically derived fluxes and measured mass indices for the 2015 encounter with the meteoroid stream. This is to be compared with other meteoroid stream mass estimates including that of the Perseids, caused by comet Swift Tuttle.

Blaauw, R.

Mass loss during the RR Lyrae phase of the horizontal branch: Mass dispersion on the horizontal branch and RR Lyrae period changes

Mass loss on the horizontal branch has been invoked in the literature to explain such phenomena as the color (mass) dispersion of the horizontal branch and the observed distribution of period changes in RR Lyrae stars. To test these claims, the Yale stellar evolution code was used to evolve horizontal branch models of masses 0.64, 0.66, 0.68, 0.70, and 0.72 solar mass with Z of 0.001, core mass of 0.4893, main-sequence helium abundance of 0.23, and constant mass loss rates of 0, 10(exp -10), 5 x 10(exp -10), and 10(exp -9) solar mass/yr. Mass loss was assumed to occur only in the instability strip, where a mechanism is most likely to exist. Synthetic horizontal branches, constructed from the models, show that mass loss on the horizontal branch cannot produce the observed color dispersion even for the highest mass-loss rate of 10(exp -9) solar mass/yr. Mass loss is unlikely to occur at a higher rate without significant effects on the horizontal branch morphology, which would destroy the good agreement between standard synthetic models without mass loss and observed horizontal branches. Periods and period changes were calculated for all models. The period changes are not significantly larger for models with mass loss. The effect of mass loss in clusters of other metallicities is discussed.

Koopmann, Rebecca A.

High-precision mass measurement of 103 Sn restores smoothness of the mass surface

As a step towards the ultimate goal of a high-precision mass measurement of doubly magic 100 Sn, the mass of 103 Sn was measured at the Low Energy Beam and Ion Trap (LEBIT) located at the Facility for Rare Isotope Beams (FRIB). Utilizing the time-of-flight ion cyclotron resonance technique, a mass uncertainty of 3.7 keV was achieved, an improvement by more than an order of magnitude compared to a recent measurement performed in 2023 at the Cooler Storage Ring (CSRe) in Lanzhou. Although the LEBIT and CSRe mass measurements of 103 Sn are in agreement, they diverge from the experimental mass value reported in the 2016 version of the Atomic Mass Evaluation (AME2016), which was derived from the measured 𝑄 𝛽 + value and the mass of 103 In. In AME2020, this indirectly measured 103 Sn mass was classified as a “seriously irregular mass” and replaced with an extrapolated value, which aligns with the most recent measured values from CSRe and LEBIT. As such, the smoothness of the mass surface is confidently reestablished for 103 Sn. Here, LEBIT's mass measurement of 103 Sn enabled a significant reduction in the mass uncertainties of five parent isotopes which are now dominated by uncertainties in their respective 𝑄 values.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS

Predictions for a Low-mass Cutoff for the Primordial Black Hole Mass Spectrum

In this note, we outline how a modest violation in the conservation of mass during the merger of two PBHs affects the PBH mass spectrum that we previously obtained using a Boltzmann equation model for the evolution of the mass spectrum with no mass loss. We find that if the initial cosmological redshift is of the order of 10 12 , then the fraction of primordial holes with masses greater than 10 3 solar masses appears to be close to what is required to provide the seeds for galaxies. In addition, we note that as a result of rapid collisions and strong coupling to electromagnetic radiation for temperatures > GeV, there will be an effective low-mass cutoff in the mass spectrum for PBH masses less than a certain PBH mass less than 0.1M ⊙ . We also point out that this cutoff in the mass spectrum below ~ 0.1M ⊙ can be confirmed by combining future microlensing observations from the Roman Space Telescope and the Vera C. Rubin Observatory with astrometric observations.

79 ASTRONOMY AND ASTROPHYSICS

Low Masses and High Redshifts: The Evolution of the Mass-Metallicity Relation

We present the first robust measurement of the high redshift mass-metallicity (MZ) relation at 10(exp 8) < M/Stellar Mass < or approx. 10(exp 10), obtained by stacking spectra of 83 emission-line galaxies with secure redshifts between 1.3 < or approx. z < or approx. 2.3. For these redshifts, infrared grism spectroscopy with the Hubble Space Telescope Wide Field Camera 3 is sensitive to the R23 metallicity diagnostic: ([O II] (lambda)(lambda)3726, 3729 + [OIII] (lambda)(lambda)4959, 5007)/H(beta). Using spectra stacked in four mass quartiles, we find a MZ relation that declines significantly with decreasing mass, extending from 12+log(O/H) = 8.8 at M = 10(exp 9.8) Stellar Mass to 12+log(O/H)= 8.2 at M = 10(exp 8.2) Stellar Mass. After correcting for systematic offsets between metallicity indicators, we compare our MZ relation to measurements from the stacked spectra of galaxies with M > or approx. 10(exp 9.5) Stellar Mass and z approx. 2.3. Within the statistical uncertainties, our MZ relation agrees with the z approx. 2.3 result, particularly since our somewhat higher metallicities (by around 0.1 dex) are qualitatively consistent with the lower mean redshift (z = 1.76) of our sample. For the masses probed by our data, the MZ relation shows a steep slope which is suggestive of feedback from energy-driven winds, and a cosmological downsizing evolution where high mass galaxies reach the local MZ relation at earlier times. In addition, we show that our sample falls on an extrapolation of the star-forming main sequence (the SFR-M∗ relation) at this redshift. This result indicates that grism emission-line selected samples do not have preferentially high star formation rates (SFRs). Finally, we report no evidence for evolution of the mass-metallicity-SFR plane; our stack-averaged measurements show excellent agreement with the local relation.

Hgih Redshifts

Influence of Altered Mass Loading on Testosterone Levels and Testicular Mass

Effects of altered load on testosterone levels and testicular mass in mammals are not well defined. Two separate studies (loading;centrifuged; +2G(sub z) and unloading;hindlimb suspension;HLS) were conducted to provide a better understanding of the effects of mass loading on testosterone levels and testicular mass. Daily urine samples were collected, and testicular mass measured at the end of the study. +2G(sub z): Sprague-Dawley rats (230-250 g) were centrifuged for 12 days at +2G(sub z): 8 centrifuged (EC) and 8 off centrifuge controls (OCC). EC had lower body mass, however relative testicular mass was greater. EC exhibited an increase in excreted testosterone levels between days 2 (T2) and 6 (T6), and returned to baseline at T9. HLS: To assess the effects of unloading Sprague-Dawley rats (125-150 g) were studied for 12 days: 10 suspended (Exp) and 10 ambulatory (Ctl). Exp had lower body mass during the study, with reduced absolute and relative testicular mass. Exp demonstrated lower excreted testosterone levels from T5-T12. Conclusions: Loading appears to stimulate anabolism, as opposed to unloading, as indicated by greater relative testicular mass and excreted testosterone levels. Reported changes in muscle mass during loading and unloading coincide with similar changes in excreted testosterone levels.

Wang, Tommy J.

Auriga Streams III: the mass–metallicity relation does not rule out tidal mass-loss in Local Group satellites

The mass–metallicity relation is a fundamental galaxy scaling law that has been extended to the faintest systems in the Local Group. We show that the small scatter in this relation, which has been used to argue against tidal mass-loss in Local Group satellites, is consistent with the level of disruption in the Auriga simulations. For every accreted system in Auriga, we compute stellar masses and metallicities two ways: considering the total system (bound + lost material) and only considering the progenitor. Accreted systems in Auriga have a tight relation between total stellar mass and metallicity, with scatter at a fixed stellar mass driven by age. When only considering the progenitor, the tidally evolved mass–metallicity relation has similar scatter (⁠~0.27 dex) as observed for the Local Group satellites (⁠~0.23 dex). Satellites that lie above the evolved relation have experienced substantial mass-loss and typically have low metallicity for their total stellar mass. Even satellites that fall exactly on the evolved relation can lose over half of their stellar mass. Only satellites substantially below the evolved relation are reliably intact. Based on their offset from the observed relation, we predict which Milky Way and M31 satellites have tidal tails waiting to be discovered.

Galaxy: halo

Orbital Characterization of GJ1108A System, and Comparison of Dynamical Mass with Model-Derived Mass for Resolved Binaries

We report an orbital characterization of GJ1108Aab that is a low-mass binary system in the pre-main-sequence phase. Via the combination of astrometry using adaptive optics and radial velocity measurements, an eccentric orbital solution of e = 0.63 is obtained, which might be induced by the Kozai–Lidov mechanism with a widely separated GJ1108B system. Combined with several observed properties, we confirm that the system is indeed young. Columba is the most probable moving group, to which the GJ1108A system belongs, although its membership to the group has not been established. If the age of Columba is assumed for GJ1108A, the dynamical masses of both GJ1108Aa and GJ1108Ab (M(sub dynamical,GJ1108Aa) = 0.72 ± 0.04 Solar Mass and M(sub dynamical,GJ1108Ab) = 0.30 ± 0.03 Solar Mass) are more massive than what an evolutionary model predicts based on the age and luminosities. We consider that the discrepancy in mass comparison can be attributed to an age uncertainty; the system is likely older than stars in Columba, and effects that are not implemented in classical models such as accretion history and magnetic activity are not preferred to explain the mass discrepancy. We also discuss the performance of the evolutionary model by compiling similar low-mass objects in the evolutionary state based on the literature. Consequently, it is suggested that the current model on average reproduces the mass of resolved low-mass binaries without any significant offsets.

Mizuki, T.

Compact piezoelectric resonance mass balance for sample verification and mass quantification and mixing.

There is a need for sample verification and mass quantification of rock, soil and/or ice obtained by sample acquisition mechanisms on extraterrestrial bodies. For many scientific instruments information about the mass of the sample would aid in the interpretation of the data and help prevent the portioning system from overloading instrument ports. Additionally, on a potential sample return mission it is likely that a sample confirmation or mass determination requirement would be implemented before the spacecraft would be commanded to return to Earth or Lunar orbit. In an effort to meet these potential requirements, a piezoelectric resonance balance is being developed to measure a frequency change proportional to the sample mass change. In previous work1 we developed a resonance balance which produced large non-linear frequency changes due to the addition of a large mass. In this study we have looked at a variety of resonator geometries in an effort to linearize the frequency shift with mass. In addition, we have investigated the use of oscillator/counter circuitry to track the frequency shift of the piezoelectric mass balance. In this new design the frequency shifts automatically when a mass is placed on the balance and the counter circuit calculates the frequency shift. This frequency is then converted to a mass using calibration tables determined previously. An additional feature we have implemented is the use of a high frequency thickness mode piezoelectric resonator to mix the sample and a reactant or solvent. This allows for measuring both sample and reagent prior to ingestion by the instrument. This paper will focus on the design requirements and how they are affected by the local gravity and acoustic properties of the sample. Designs which allow for easy loading and unloading of the balance will also be discussed.

Yahnker, Christopher R.

The He I 2.06 microns/Br-gamma ratio in starburst galaxies - An objective constraint on the upper mass limit to the initial mass function

The use of the He I 2.06 microns/Br-gamma ratio as a constraint on the massive stellar population in star-forming galaxies is developed. A theoretical relationship between the He I 2.06 microns/Br-gamma ratio and the effective temperature of the exciting star in H II regions is derived. The effects of collisional excitation and dust within the nebula on the ratio are also considered. It is shown that the He I 2.06 microns/Br-gamma ratio is a steep function of the effective temperature, a property which can be used to determine the upper mass limit of the initial mass function (IMF) in galaxies. This technique is reliable for upper mass limits less than about 40 solar masses. New near-infrared spectra of starburst galaxies are presented. The He I 2.06 microns/Br-gamma ratios observed imply a range of upper mass limits from 27 to over 40 solar masses. There is also evidence that the upper mass limit is spatially dependent within a given galaxy. These results suggest that the upper mass limit is not a uniquely defined parameter of the IMF and probably varies with local physical conditions.

Doyon, Rene

Enhancing the mass resolving power of FRIB’s proposed high-voltage MR-ToF mass separator and spectrometer: Addressing non-ideal conditions

Multi-reflection time-of-flight mass separators and spectrometers (MR-ToF MSs) are indispensable tools at radioactive ion beam (RIB) facilities. These electrostatic ion beam traps act as highly selective mass separators and high-precision mass spectrometers for rare and exotic nuclei. When well-tuned and designed to minimize higher-order flight-time aberrations, state-of-the-art MR-ToF MSs approach, and slightly exceed, mass resolving powers of m/Δm = 10 6 . Achieving m/Δm ≥ 3 ⋅ 10 6 would provide the ability to resolve > 90 % of all known isomeric states with half-lives above 10 ms. However, the ability to mass separate in all practical setups is limited by non-ideal conditions which place such resolving powers out of reach. Here, to this end, we present a simulated analysis of these conditions in the newly proposed high-voltage MR-ToF MS for the Facility for Rare Isotope Beams (FRIB). It is expected to store ions at 30 keV beam energy and increase ion throughput by two orders of magnitude compared to current devices. Existing efforts to mitigate the effects of non-ideal conditions employed for current MR-ToF devices storing ions at < 3 keV beam energy will already enable mass resolving powers approaching 10 6 for FRIB’s high-voltage MR-ToF device. Simulations of newly proposed mitigation strategies show that even mass resolving powers approaching 10 7 might become feasible.

Electrostatic ion beam traps

Measurement of the jet mass in hadronic decays of boosted W bosons at 13 TeV and extraction of the W boson mass

The jet mass of W bosons decaying to a quark-antiquark pair is measured in W+jets events from proton-proton collisions at a center-of-mass energy of 13 TeV. The data used were collected by the CMS experiment at the CERN LHC and correspond to an integrated luminosity of 138 fb −1 . Hadronic decays of W bosons with high momenta produce strongly collimated decay products due to the large Lorentz boost, and are reconstructed as single large-radius jets. These jets have a characteristic substructure that is exploited to distinguish them from the large background of quark- and gluon-initiated jets. The jet mass is computed using the soft-drop algorithm, which suppresses soft wide-angle radiation that leads to a broadening of the jet mass distribution. For the first time, unfolded measurements are presented of the double-differential W+jets cross section as a function of the jet transverse momentum and soft-drop mass. From these distributions, the W boson mass is obtained, with a value of 80.83 ± 0.55 GeV in a scheme with mass-dependent width, achieving the smallest uncertainty available today from an all-jets final state at a hadron collider.

hadron-hadron scattering