Search NASA⌕ Search

SEARCH · Search NASA

Results for “Mass spectra”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Interpretation of the ion mass spectra in the mass per charge range 25-35 amu/e obtained in the inner coma of Halley's comet by the HIS-sensor of the Giotto IMS experiment

The IMS-HIS double-focusing mass spectrometer that flew on the Giotto spacecraft covered the mass per charge range from 12 to 56 (amu/e). By comparing flight data, calibration data and results of model calculations of the ion population in the inner coma, the absolute mass scale is established, and ions in the mass range 25 to 35 are identified. Ions resulting from protonation of molecules with high proton affinity are relatively abundant, enabling us to estimate relative source strengths for H2CO, CH3OH, HCN, and H2S, providing for the first time a positive in situ measurement of methanol. Also, upper limits for NO and some hydrocarbons are derived.

Geiss, J.↗

Interpretation of the ion mass spectra in the mass range 25-35 obtained in the inner coma of Halley's comet by the HIS-sensor of the Giotto IMS Experiment

The IMS-HIS double-focussing mass spectrometer that flew on the Giotto spacecraft covered the mass per charge range from 12 to 56 (AMU/e). By comparing flight data, calibration data, and results of model calculations of the ion population in the inner coma, the absolute mass scale is established, and ions in the mass range 25 to 35 are identified. Ions resulting from protonation of molecules with high proton affinity are relatively abundant, enabling us to estimate relative source strengths for H2CO, CH3OH, HCN, and H2S, providing for the first time a positive in situ measurement of methanol. Also, upper limits for NO and some hydrocarbons are derived.

Geiss, J.↗

Decomposition of Electron Ionization Mass Spectra for Space Application Using a Monte-Carlo approach

Rationale: Quadrupole mass spectrometers equipped with an electron ionization (EI) sources have been widely used in space exploration to investigate the composition of planetary surfaces and atmospheres. However, the complexity of the samples and the minimal calibration for the fragmentation of molecules in the ionization chambers have prevented the deconvolution of the majority of the mass spectra obtained at different targets, thus limiting the determination of the exact composition of the samples analyzed. We propose a Monte‐Carlo approach to solve this issue mathematically. Methods: We decomposed simulated mass spectra of mixtures acquired with unit resolving power mass spectrometers and EI sources into the sum of the single components fragmentation patterns weighted by their relative concentration using interior‐point least‐square fitting. To fit compounds with poorly known fragmentation patterns, we used a Monte‐Carlo method to vary the intensity of individual fragment ions. We then decomposed the spectrum thousands of times to obtain a statistical distribution. Results: By performing the deconvolution on a mixture of seven different molecules with interfering fragmentation patterns (H2O, O2, CH4, Ar, N2, C2H4, and C2H6) we show that this approach retrieves the mixing ratio of the individual components more accurately than regular mass spectra decomposition methods that rely on fragmentation patterns from general databases. It also provides the probability density function for each species's mixing ratio. Conclusions: By removing the solution degeneracy in the decomposition of mass spectra, the method described herein could significantly increase the scientific retrieval from archived space flight mass spectrometry data, where calibration of the ionization source is no longer an option.

Thomas Gautier↗

Preliminary results of investigations into the use of artificial neural networks for discriminating gas chromatograph mass spectra of remote samples

Neural networks trained using mass spectra data from the National Institute of Standards and Technology (NIST) are studied. The investigations also included sample data from the gas chromatograph mass spectrometer (GCMS) instrument aboard the Viking Lander, obtained from the National Space Science Data Center. The work performed to data and the preliminary results from the training and testing of neural networks are described. These preliminary results are presented for the purpose of determining the viability of applying artificial neural networks in discriminating mass spectra samples from remote instrumentation such as the Mars Rover Sample Return Mission and the Cassini Probe.

Geller, Harold A.↗

PIA update: Correlation analyses of mass spectra

The PIA instrument aboard the Giotto spacecraft (a time of flight spectrometer) has been presented elsewhere. The mass spectra used in this analysis were decoded and mass numbers assigned according to the presence of carbon and silver, using the global values for these elements in their spectral absence. The results presented here were obtained using a frequency of occurrence based on analysis which correlated how often mass numbers appear in the mass spectra and which mass numbers tend to occur together in the same spectra; no amplitude information is utilized. The data are presented as plots of mass vs coincident mass for different subsets of the PIA data set, with both axes having units of atomic mass. Frequency contours are plotted at approximately five percent contour intervals, relative to the maximum AMU occurrence in that plot. The plots presented are symmetrical about the matrix diagonal, i.e., every mass is coincident with itself in a given spectra.

Mason, L. W.↗

Mass Spectra Deconvolution of Gaseous Mixtures Containing Volatile Organic Compounds

The Spacecraft Atmosphere Monitor (S.A.M.) analyzes all gaseous pollutants in the 1-150Th mass-to-charge range based on their positive-ion mass spectra. Of particular interest is the Trace Gas Analysis (TGA) mode of operation in which S.A.M detects minute amounts of volatile organic compounds (VOC). Pollutant component of the ambient air is sampled on demand in twenty full mass spectra per second. All spectra is accumulated in two-second intervals by an on-board Field Programmable Gate Arrays (FPGA) unit. Mass spectra represents the number of detected fragment ions in a given mass-to-charge ratio channel. Electron impact ionization of neutral molecules results in creation of numerous fragment ions and most of organic compounds will contribute several identical fragments. Despite the presence of these molecular isobars, we developed the deconvolution algorithm capable of identifying target species based on their characteristic fragmentation patterns. We investigate the efficiency of deconvolution algorithm as a function of mass resolution with which mass spectrum is acquired. Higher the mass resolution, better the chances are to distinguish between stereoisomers using their fragmentation propensities, but also results in higher data volumes to be processed by a set of small footprint software stacks hosted by an on-board computer. Finding the balance between deconvolution accuracy and generated data volume under time constrains and limited computing resources is the main topic of this study.

Darrach, M.↗

Mass spectra of sputtered polyoxymethylene - Implications for comets

Laboratory mass spectra of sputtered polyoxymethylene, POM, reveal a mass pattern similar to that detected by the PICCA experiment on board the Giotto spacecraft. Both commercially available POM and radiation-synthesized POM have been used in the studies. Synthesized POM was identified by its infrared absorption spectra after proton irradiation of H2CO condensed on silicate grains at 20 K. Laboratory results suggest that a similar type of sputtering is a possible mechanism for removing species from cometary grains.

Moore, Marla H.↗

Compound classification by computer treatment of low resolution mass spectra - Application to geochemical and environmental problems.

A description is given of a development of computer analysis of low-resolution chromatographic-mass spectrometric data, which provides a preliminary classification of an unknown spectrum as a listing of candidate classes of compounds. This procedure, referred to as COMSOC (Classification of Mass Spectra on Computers), operates by converting an incoming unknown mass spectrum into a simplified key word which is then compared with each of the key words held in its reference file. The advantages of COMSOC in characterizing complex mixtures are emphasized.

Smith, D. H.↗

Computer programs for the interpretation of low resolution mass spectra: Program for calculation of molecular isotopic distribution and program for assignment of molecular formulas

Two FORTRAN computer programs for the interpretation of low resolution mass spectra were prepared and tested. One is for the calculation of the molecular isotopic distribution of any species from stored elemental distributions. The program requires only the input of the molecular formula and was designed for compatability with any computer system. The other program is for the determination of all possible combinations of atoms (and radicals) which may form an ion having a particular integer mass. It also uses a simplified input scheme and was designed for compatability with any system.

Miller, R. A.↗