Search NASA⌕ Search

SEARCH · Search NASA

Results for “Mass spectrometry (MS)”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Algorithms and file structures to extend and enhance liquid chromatography and ion mobility mass spectrometry workflows (CRADA Final Report)

The purpose of this project was to continue supporting customizations of algorithms and raw data file structures to enhance software workflows for liquid chromatography (LC), mass spectrometry (MS) and ion mobility mass spectrometry (IM-MS)-based protein and metabolite characterization. PNNL worked with Agilent to design, implement, evaluate, and demonstrate new algorithms and integrated them as functionalities into the PNNL-PreProcessor software. The project augmented PNNL’s capabilities to analyze complex proteomics and metabolomics samples. These capabilities are directly beneficial to DOE and PNNL efforts to characterize and analyze these compounds in microbial and plant communities. The project assisted Agilent in further developing improved instrument-software solutions combining liquid chromatography and ion mobility with mass spectrometry for widespread applications in life sciences and other fields.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Applications of Alternate Actinide Calibration on Inductively Coupled Plasma Mass Spectrometry (ICPMS) Analysis of H-Canyon Highly Enriched Uranium Legacy Material at the Savannah River Site (SRS)

The Savannah River National Laboratory (SRNL) uses Inductively Coupled Plasma Mass Spectrometry (ICPMS) to support numerous programs at the Savannah River Site (SRS). As part of an objective to prepare high assay low enriched uranium (HALEU), the SRS H-Canyon needed analysis of legacy uranyl nitrate that is stored at its Outside Facilities (HOF). With the application of a standard practice for alternate actinide calibration on ICP-MS, SRNL has successfully demonstrated its capability to characterize the uranium/actinide composition of the HOF tanks that are intended for consolidation prior to preparation of the HALEU. A comparison of the uranium analytical results between recently upgraded SRNL ICP-MS and Inductively Coupled Plasma Optical Emission Spectrometry (ICP-OES) instrumentation shows the alternate actinide calibration is a valid complementary method when used in conjunction with other analytical techniques (Davies-Gray Potentiometric Titration). The methods, instrumentation, and ongoing developments on ICP-MS at SRNL will be discussed.

Jones, Mark A.↗

Grazer-induced changes in molecular signatures of cyanobacteria

Algal biomass production is an emerging renewable source of fuels, nutrients, manufacturing materials, and pharmaceuticals. Industrial-scale production is predominantly performed in open raceway ponds that are inexpensive to build, operate, and maintain compared to closed bioreactors. However, these open pond systems suffer from increased opportunities for biological contamination from predators, pathogens, and competitors, which result in reduced biomass quality and yields and often the complete destruction of the crop over a short period of time. Early detection of contaminants is a necessary step of integrated pest management for triggering and informing interventions to prevent crop losses. To develop a sensitive method of detection utilizing mass spectrometry (MS), we used three methods – imaging mass spectrometry (imaging MS), liquid chromatography MS/MS (LC-MS/MS) combined with molecular networking, and gas chromatography MS/MS (GC–MS/MS) – to observe and identify molecular signatures from a model predator-prey system of the heterolobosean amoeba HGG1 preying on the filamentous cyanobacterium Anabaena sp. PCC 7120. Imaging MS enabled the association of molecules with the crop, the predator, or the activity of protozoan grazing, while LC-MS/MS-based molecular networking identified a subset of the grazing-specific signals as the chlorophyll breakdown products pyropheophytin, pheophorbide A, and pyropheophorbide. Application of MS techniques to other amoebacyanobacterial predator-prey pairs allowed categorization of grazing signatures as universal or specific to the species of prey, predator, or the prey-predator pairing, indicating that MS-based techniques can distinguish crops from competitors and potentially identify predators. Finally, GCMS/MS was shown to be capable of monitoring novel volatile organic compounds (VOCs), including those predicted to be released through chlorophyll breakdown, in the headspace over algal cultures under predation. Furthermore, these results demonstrate that the combination of multiple MS technologies creates a predictive framework to identify and catalog relevant molecular signatures for informing crop protection strategies.

09 BIOMASS FUELS↗

Algorithms and file structures to enhance software workflows for ion mobility mass spectrometry (IM-MS)

Support customizations of algorithms and raw data file structures to enhance software workflows for liquid chromatography (LC), mass spectrometry (MS) and ion mobility mass spectrometry (IM-MS)-based metabolite characterization. Evaluate and improve the integration of ion mobility to existing MS analysis methods of the Mass Profiler Professional workflow (Mass Profiler, ID Browser and Mass Profiler Professional).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Internal Fragments Generated by Electron Ionization Dissociation Enhance Protein Top-Down Mass Spectrometry

Top-down proteomics by mass spectrometry (MS) involves the mass measurement of an intact protein followed by subsequent activation of the protein to generate product ions. Electron-based fragmentation methods like electron capture dissociation and electron transfer dissociation are widely used for these types of analyses. Recently, electron ionization dissociation (EID), which utilizes higher energy electrons (>20 eV) has been suggested to be more efficient for top-down protein fragmentation compared to other electron-based dissociation methods. In this paper, we demonstrate that the use of EID enhances protein fragmentation and subsequent detection of protein fragments. Protein product ions can form by either single cleavage events, resulting in terminal fragments containing the C-terminus or N-terminus of the protein, or by multiple cleavage events to give rise to internal fragments that include neither the C-terminus nor the N-terminus of the protein. Conventionally, internal fragments have been disregarded, as reliable assignments of these fragments were limited. Here, we demonstrate that internal fragments generated by EID can account for ~20–40% of the mass spectral signals detected by top-down EID-MS experiments. By including internal fragments, the extent of the protein sequence that can be explained from a single tandem mass spectrum increases from ~50 to ~99% for 29 kDa carbonic anhydrase II and 8.6 kDa ubiquitin. When searching for internal fragments during data analysis, previously unassigned peaks can be readily and accurately assigned to confirm a given protein sequence and to enhance the utility of top-down protein sequencing experiments.

59 BASIC BIOLOGICAL SCIENCES↗

Algorithms and file structures to enhance software workflows for ion mobility mass spectrometry (IM-MS): CRADA 410 (Final Report)

This document is the final report for CRADA 410 (Project No. 72496). The purpose of this project was supporting customizations of algorithms and raw data file structures to enhance software workflows for liquid chromatography (LC), mass spectrometry (MS) and ion mobility mass spectrometry (IM-MS)-based metabolite characterization. PNNL worked with Agilent to evaluate and improve the integration of ion mobility into existing MS data analysis methods of Agilent software tools. The project augmented PNNL’s capabilities to analyze complex omics samples. These capabilities are directly beneficial to DOE and PNNL efforts to characterize and analyze compounds in microbial and plant communities. The project assisted Agilent in further developing improved instrument-software solutions combining ion mobility with mass spectrometry for widespread applications in life sciences and other fields.

97 MATHEMATICS AND COMPUTING↗

Spatially Resolved Mass Spectrometry at the Single Cell: Recent Innovations in Proteomics and Metabolomics

Biological systems are composed of heterogeneous populations of cells that intercommunicate to form a functional living tissue. Biological function varies greatly across populations of cells, as each single cell has a unique transcriptome, proteome, and metabolome that translates to functional differences within single species and across kingdoms. Over the past decade, substantial advancements in our ability to characterize omic profiles on a single cell level have occurred, including in multiple spectroscopic and mass spectrometry (MS)-based techniques. Of these technologies, spatially resolved mass spectrometry approaches, including mass spectrometry imaging (MSI), have shown the most progress for single cell proteomics and metabolomics. For example, reporter-based methods using heavy metal tags have allowed for targeted MS investigation of the proteome at the subcellular level, and development of technologies such as laser ablation electrospray ionization mass spectrometry (LAESI-MS) now mean that dynamic metabolomics can be performed in situ. In this Perspective, we showcase advancements in single cell spatial metabolomics and proteomics over the past decade and highlight important aspects related to high-throughput screening, data analysis, and more which are vital to the success of achieving proteomic and metabolomic profiling at the single cell scale. Finally, using this broad literature summary, we provide a perspective on how the next decade may unfold in the area of single cell MS-based proteomics and metabolomics.

59 BASIC BIOLOGICAL SCIENCES↗

The Determination of the Spatial Distribution of Indigenous Lipid Biomarkers in an Immature Jurassic Sediment Using Time-of-Flight–Secondary Ion Mass Spectrometry

The ability to detect and map lipids, including potential lipid biomarkers, within a sedimentary matrix using mass spectrometry (MS) imaging may be critical to determine whether potential lipids detected in samples returned from Mars are indigenous to Mars or are contaminants. Here, we use gas chromatography–mass spectrometry (GC-MS) and time-of-flight–secondary ion mass spectrometry (ToF-SIMS) datasets collected from an organic-rich, thermally immature Jurassic geologic sample to constrain MS imaging analysis of indigenous lipid biomarkers in geologic samples. GC-MS data show that the extractable fractions are dominated by C 27 –C 30 steranes and sterenes as well as isorenieratene derivatives. ToF-SIMS spectra from organic matter-rich laminae contain a strong, spatially restricted signal for ions m/z 370.3, m/z 372.3, and m/z 386.3, which we assign to C 27 sterenes, cholestane (C 27 ), and 4- or 24-methyl steranes (C 28 ), respectively, as well as characteristic fragment ions of isorenieratene derivatives, including m/z 133.1, m/z 171.1, and m/z 237.1. We observed individual steroid spatial heterogeneity at the scale of 10's to 100's of microns. The fine-scale heterogeneity observed implies that indigenous lipid biomarkers concentrated within specific regions may be detectable via ToF-SIMS in samples with even low amounts of organic carbon, including in samples returned from Mars.

59 BASIC BIOLOGICAL SCIENCES↗

Mass Spectrometric Determination of Site-Specific O -Acetylation in Rhamnogalacturonan I Oligomers

O-acetylation, a common modification in rhamnogalacturonan I (RG-I), is critical for various biological processes, including plant growth, stress responses, and pathogen defense. Precise determination of the degree and specific positions of acetylation is therefore essential. To date, nuclear magnetic resonance (NMR) and tandem mass spectrometry have been employed to identify O-acetyl positions in pectin oligosaccharides. Although NMR is effective, it requires pure, high-concentration samples. Tandem mass spectrometry (MS), which uses smaller sample amounts, faces challenges due to O-acetyl migration between monosaccharide positions. The multiple steps in pectin sample analysis can further promote O-acetyl migration, especially near free hydroxyl groups. Moreover, during tandem MS, O-acetyl groups may detach, complicating the accurate tracking. This study presents an approach to lock O-acetyl groups by introducing trideuteroacetyl and propionyl substituents onto free hydroxyls of RG-I or partially acetylated RG-I. By combining matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) MS and electrospray ionization (ESI) MS with MS/MS or tandem mass spectrometry (MSn), we devised a way to determine the monosaccharide sequence in the oligomer and the precise positions of O-acetyl groups in partially acetylated RG-I. This method enables the study of the regiospecificity of recombinant pectin O-acetyltransferases and can be applied to other oligosaccharides to determine acyl positions.

O-acetylation↗

Improved Fundamental Understanding of Aluminum Chemistry and Interactions of Aluminate Anion with Co-Anions: ORNL Project Progress Report

The U.S. Department of Energy (DOE)’s Hanford Site in Washington State houses 177 underground storage tanks containing millions of gallons of nuclear and chemical waste with high aluminum content. Aluminum (Al) salt reactions with strong bases produce aluminum hydroxides, like boehmite (γ-AlOOH), which are main components of insoluble nuclear waste sludge. Understanding the morphology, crystallinity, and dissolution behavior of boehmite under waste tank conditions is necessary for improving waste management and mitigation strategies. The ORNL team uses in situ multimodal analysis strategy to study Al chemistry of simulated tank waste using microfluidic reactors and advanced chemical imaging and mass spectrometry (MS) techniques. Because the SALVI device is vacuum compatible and transferrable among different platforms, we can use it in scanning electron microscopy (SEM), vacuum ultraviolet single photon mass spectrometry (VUV SPI-MS), and time-of-flight secondary ion mass spectrometry (ToF-SIMS) to study the chemical speciation and colloid stability in liquids in this project. Additionally, ex situ transmission electron microscopy (TEM) and x-ray diffraction (XRD) spectroscopy can be used to verify particle phase to further the understanding of the Al-bearing phases. This report gives a summary of the technical progress of the ORNL tasks. A plan for year 2 performance is recommended in the summary.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A combinatorial droplet microfluidic device integrated with mass spectrometry for enzyme screening

Mass spectrometry (MS) enables detection of different chemical species with a very high specificity; however, it can be limited by its throughput. Integrating MS with microfluidics has a tremendous potential to improve throughput and accelerate biochemical research. In this work, we introduce Drop-NIMS, a combination of a passive droplet loading microfluidic device and a matrix-free MS laser desorption ionization technique called nanostructure-initiator mass spectrometry (NIMS). This platform combines different droplets at random to generate a combinatorial library of enzymatic reactions that are deposited directly on the NIMS surface without requiring additional sample handling. The enzyme reaction products are then detected with MS. Drop-NIMS was used to rapidly screen enzymatic reactions containing low (on the order of nL) volumes of glycoside reactants and glycoside hydrolase enzymes per reaction. MS “barcodes” (small compounds with unique masses) were added to the droplets to identify different combinations of substrates and enzymes created by the device. We assigned xylanase activities to several putative glycoside hydrolases, making them relevant to food and biofuel industrial applications. Overall, Drop-NIMS is simple to fabricate, assemble, and operate and it has potential to be used with many other small molecule metabolites.

47 OTHER INSTRUMENTATION↗

Model-based compositional predictions for a differential scanning calorimetry/thermogravimetric analysis-mass spectrometry system used for heat of vaporization measurements

A Differential Scanning Calorimetry/Thermogravimetric Analysis (DSC/TGA) procedure for determination of Heat of Vaporization (HOV) of fuel and surrogate fuel mixtures has been previously utilized for evaluation of oxygenate impacts on spark ignition fuels. This analysis has been further leveraged with mass spectrometry (MS) to elucidate vapor phase compositional changes during evaporation. In this study we focus on a simple system of three compounds (ethanol, n-hexane, and n-octane) to provide a model-based understanding of the evaporation process under these experimental conditions. An Aspen Plus model was set up to provide liquid and vapor phase concentration predictions during mixture evaporation using the initial mixture composition, and measured temperature and mass loss profiles from DSC/TGA experiments. Agreements between the trends of the MS ion count profiles and model composition predictions provide a degree of validation of this modeling approach that can allow the interpretation and extrapolation of DSC/TGA measurements for more complex fuel mixtures.

33 ADVANCED PROPULSION SYSTEMS↗

Direct analysis of cotton swipes for uranium and plutonium isotopic determination by microextraction-ICP-MS

The determination of uranium and plutonium isotopic abundance on environmental samples collected by International Atomic Energy Agency (IAEA) inspectors is vital for the detection of undeclared nuclear activities and material under the international nuclear safeguards regime. Current analytical protocols require time-consuming sample preparation steps prior to subsequent measurement by inorganic mass spectrometry (MS). Recent efforts from this laboratory have focused on developing sample preparation methods for faster analysis, potentially allowing higher sample throughput[1]. Alternative methods including microextraction sampling in conjunction with inductively coupled plasma-mass spectrometry (ICP-MS) have been recently explored. This methodology, microextraction-ICP-MS, was developed such that uranium and plutonium could be extracted from the swipe surface and directed into the ICP-MS for an in-situ measurement, eliminating the need for swipe ashing and digestion. A commercial off-the-shelf microextraction system was customized with an automated movable XY stage that can be programmed to save sampling locations, allowing for automated rapid sampling of swipe surfaces. Additional efforts have focused on the utilization of collision cell technology to the microextraction ICP-MS method. This would eliminate the need for lengthy column chemistry procedures to purify separated uranium and plutonium fractions before analysis. Here, the extracted U/Pu analyte is measured by reacting the uranium ions with CO2 in the collision cell of an ICP-MS, shifting the uranium to UO+, which will not interfere with the plutonium isotopic determination. The developed method utilizing collision cell – ICP-MS technology has demonstrated the ability to measure plutonium isotope ratios in the presence of high uranium concentration on the transient signal from the microextraction system utilizing certified reference materials from JRC-Geel and the New Brunswick Laboratory Program Office.

Bradley, Veronica↗

Exploring new frontiers in type 1 diabetes through advanced mass-spectrometry-based molecular measurements

Type 1 diabetes (T1D) is a devastating autoimmune disease for which advanced mass spectrometry (MS) methods are increasingly used to identify new biomarkers and better understand underlying mechanisms. For example, integration of MS analysis and machine learning has identified multimolecular biomarker panels. In mechanistic studies, MS has contributed to the discovery of neoepitopes, and pathways involved in disease development and identifying therapeutic targets. However, challenges remain in understanding the role of tissue microenvironments, spatial heterogeneity, and environmental factors in disease pathogenesis. Recent advancements in MS, such as ultra-fast ion-mobility separations, and single-cell and spatial omics, can play a central role in addressing these challenges. Here, in this work, we review recent advancements in MS-based molecular measurements and their role in understanding T1D.

60 APPLIED LIFE SCIENCES↗

Analysis of Organophosphorus-Based Nerve Agent Degradation Products by Gas Chromatography-Mass Spectrometry (GC-MS): Current Derivatization Reactions in the Analytical Chemist’s Toolbox

The field of gas chromatography-mass spectrometry (GC-MS) in the analysis of chemical warfare agents (CWAs), specifically those involving the organophosphorus-based nerve agents (OPNAs), is a continually evolving and dynamic area of research. The ever-present interest in this field within analytical chemistry is driven by the constant threat posed by these lethal CWAs, highlighted by their use during the Tokyo subway attack in 1995, their deliberate use on civilians in Syria in 2013, and their use in the poisoning of Sergei and Yulia Skripal in Great Britain in 2018 and Alexei Navalny in 2020. These events coupled with their potential for mass destruction only serve to stress the importance of developing methods for their rapid and unambiguous detection. Although the direct detection of OPNAs is possible by GC-MS, in most instances, the analytical chemist must rely on the detection of the products arising from their degradation. To this end, derivatization reactions mainly in the form of silylations and alkylations employing a vast array of reagents have played a pivotal role in the efficient detection of these products that can be used retrospectively to identify the original OPNA.

sarin↗