Search NASA⌕ Search

SEARCH · Search NASA

Results for “Matrix interferences”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

A Trapping-Micro-LC-FAIMS/dCV-MS Strategy for Ultrasensitive and Robust Targeted Quantification of Protein Drugs and Biomarkers

The sensitivity of LC-MS in quantifying target proteins in plasma/tissues is significantly hindered by co-eluted matrix interferences. While antibody-based immuno-enrichment effectively reduces interferences, developing and optimizing antibodies are often time-consuming and costly. Here, in this study, by leveraging the orthogonal separation capability of Field Asymmetric Ion Mobility Spectrometry (FAIMS), we developed a FAIMS/differential-compensation-voltage (FAIMS/dCV) method for antibody-free, robust, and ultra-sensitive quantification of target proteins directly from plasma/tissue digests. By comparing the intensity-CV profiles of the target vs. co-eluted endogenous interferences, the FAIMS/dCV approach identifies the optimal CV for quantification of each target protein, thus maximizing the signal-to-noise ratio (S/N). Compared to quantification without FAIMS, this technique dramatically reduces endogenous interferences, showing a median improvement of the S/N by 14.8-fold for the quantification of 17 representative protein drugs and biomarkers in plasma or tissues and a 5.2-fold median increase in S/N over conventional FAIMS approach, which uses the peak CV of each target. We also discovered that the established CV parameters remain consistent over months and are matrix-independent, affirming the robustness of the developed FAIMS/dCV method and the transferability of the method across matrices. The developed method was successfully demonstrated in three applications: the quantification of monoclonal antibodies with sub-ng/mL LOQ in plasma, an investigation of the time courses of evolocumab and its target PCSK9 in a preclinical setting, and a clinical investigation of low abundance obesity-related biomarkers. This innovative and easy-to-use method has extensive potential in clinical and pharmaceutical research, particularly where sensitive and high-throughput quantification of protein drugs and biomarkers is required.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Practical benzylation of N,N -substituted ethanolamines related to chemical warfare agents for analysis and detection by Electron Ionization Gas Chromatography-Mass Spectrometry

The benzylation of three, low-molecular weight N,N-disubstituted ethanolamines related to chemical warfare agents (CWAs) to furnish derivatives with improved Gas Chromatography-Mass Spectrometry (GC-MS) profiles is described. Due to their low molecular weight and polar nature, N,N-disubstituted ethanolamines are notoriously difficult to detect by routine GC-MS analyses during Organisation for the Prohibition of Chemical Weapons (OPCW) proficiency tests (PTs), particularly in scenarios when they are present at low levels (~1-10 ppm) amidst more abundant interferences. Our studies revealed that the optimal derivatization conditions involved the treatment of the ethanolamine with benzyl bromide in the presence of an inorganic base (e.g., Na 2 CO 3 ) in dichloromethane at 55 °C for 2 hours. This optimized set of conditions were then successfully applied to the derivatization of N,N-dimethylethanolamine, N,N-diethylethanolamine and N,N-diisopropylethanolamine present separately at 1 and 10 μg/mL concentrations in a glycerol-rich matrix sample featured in the 48 th OPCW PT. The benzylated derivatives of the three ethanolamines possessed retention times long enough to clear the massive glycerol-containing matrix interferences. In conclusion, the protocol herein is introduced as an alternative method for derivatization of these CWA and pharmaceutically important species and should find broad applicability in laboratories where their routine forensic analysis is carried out.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Utilization of the LS-APGD microplasma/orbitrap-FTMS booster system for detection and isotopic analysis of neodymium nanoparticles

Detection and isotopic analysis of particle populations has seen rapid growth across several application areas, including environmental analysis, nuclear forensics, and food safety. The ability to characterize the particles' unique elemental and isotopic fingerprints could provide information related to formation, processing history, and transport. Regarding nuclear forensics, isotopic analysis of particles derived from diverse materials is often used as a tool to trace the origin and processing history. Mass spectrometric-based techniques currently used for particle population analysis often suffer from limited mass resolution, particularly when dealing with real-world samples that are affected by isobaric and polyatomic interferences from the matrix. To address these analytical challenges, we propose a novel method utilizing the liquid sampling-atmospheric pressure glow discharge (LS-APGD) microplasma ionization source coupled to an ultrahigh resolution Orbitrap mass spectrometer, further enhanced with the FTMS X2T Booster data acquisition and processing unit. The FTMS Booster enables acquisition of extended transient times of up to 3 s, significantly improving mass resolution, thereby reducing or even eliminating the need for prior separation of isobaric or polyatomic interferences. Additionally, the detection of low-abundance isotopes was improved by increasing the signal-to-noise (S/N) ratio. As proof of concept, this study demonstrates the feasibility of the LS-APGD/Orbitrap-FTMS X2T Booster platform for direct analysis using a suspension of well-characterized ∼120 nm neodymium particles. The quality of the isotope ratios values obtained from a few hundred particles were in good agreement with those obtained from homogeneous ionic solutions. These results highlight the potential of the LS-APGD/Orbitrap platform for rapid, accurate, and interference-resilient isotope ratio analysis of particle populations without the need for dissolution and subsequent chemical separations, offering significant advantages for nuclear forensics, safeguards, and environmental applications. The effort here also points to further paths forward, hopefully towards single particle (SP) analysis using microplasma ionization and the ultrahigh resolving power of the Orbitrap mass analyzer.

FTMS X2T booster↗

Detection of Br and I as atomic anions using liquid sampling – atmospheric pressure glow discharge/Orbitrap mass spectrometry

The quantification and determination of halogen isotope composition is essential in many fields including geochemistry and nuclear forensics. Detection of the halogen elements is commonly attempted with inductively coupled plasma mass spectrometry (ICP-MS) however, there are multiple challenges faced. Most significantly this includes very poor ionization efficiency and the potential for isobaric interferences from either matrix or plasma species. Thus, sensitivity and accuracy are often limiting issues. Here a liquid sampling-atmospheric pressure glow discharge (LS-APGD) ionization source is coupled with an ultrahigh resolution Orbitrap MS to perform halogen detection of bromine and iodine as initial analytes. This facilitates simple and sensitive detection of these elements as atomic anions from simple aqueous salt solutions. Collision-induced dissociation (CID) and higher-energy collisional dissociation (HCD) energies were optimized to produce the maximum response of Br − and I − . The LS-APGD conditions were optimized using a design of experiments (DOE) approach for Br − and I − concurrently. Response curves for Br − and I − solutions determined limit of detection (LOD) values of 50 pg and 5 pg, respectively, in 20 μL aliquots. The curves indicated response factors of 0.67 for 79 Br − and 0.90 for 127 I − . Br isotope ratios were determined with precision between 0.7 and 7.3% RSD, with the isotope ratios determined with precision 0.8% RSD at concentrations above the limit of quantification. Preliminary tests were conducted to evaluate the effect of different cations (Na + , K + , and Mg 2+ ) on Br − responses, with no discernible impacts observed on the halogen signal responses. This study demonstrates the potential use of the LS-APGD-Orbitrap-MS for the detection of multiple halogens while avoiding interferences, minimizing sample preparation, and overcoming ionization barriers.

Lang, Dehlia A. [Clemson University, SC (United St↗

An Evaluation of Actinide Reactivity with CO 2 , O 2 , and O 2 /He Gases using Inductively Coupled Plasma Tandem Mass Spectrometry: Application to Simultaneous Measurement of 241 Am/ 241 Pu Ratios in Unseparated Complex Matrices

Accurate actinide measurements are critical within the field of nuclear science. Traditional methods for actinide quantification require time-consuming sample processing prior to analysis. There is a need for rapid analytical techniques that still maintain a high degree of accuracy. In this work, actinide reactivity was assessed for multiple oxygen-containing reaction gases using quadrupole inductively coupled plasma tandem mass spectrometry (Q-ICP-MS/MS) to evaluate actinide analysis in complex sample matrices without analyte-matrix separation. A novel method was developed to measure 241 Am/ 241 Pu in complex sample matrices using O 2 /He reaction gas with no matrix removal or analyte pre-concentration. This inline method reduces matrix-derived polyatomic interferences that complicate traditional ICP-MS analyses by mass-shifting to 241 Am 16 O + and 241 Pu 16 O 2 + , allowing Am and Pu to be mass separated for simultaneous analysis. While mass shifting is efficient, a small portion of Am + (<1.3%) and Pu + (<1.4%) react to from AmO 2 + and PuO + , respectively. Therefore, a mass balance approach was used, in combination with reactivity determined from 242 Pu and 243 Am standard solutions, to correct for residual 241 PuO + and 241 AmO 2 + . The method was validated by measuring 241 Am/ 241 Pu in Pu isotope standards CRM-136 and CRM-137 (separated in March/April 1970 and February 2022, respectively) in both neat solutions and complex matrices containing diluted soil (NIST SRM 2711a, >1000 µg·g -1 ). Method detection limits of 15.9 and 9.6 fg·g -1 were determined for 241 Am and 241 Pu, respectively, and 241 Am/ 241 Pu ratios were measured with accuracies within <3.5%. In conclusion, this work presents the first direct analysis of 241 Am/ 241 Pu in unseparated complex matrices, advancing capabilities for rapid actinide measurements.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Single-Particle Isotopic Analysis Using the Liquid Sampling-Atmospheric Pressure Glow Discharge Microplasma Coupled to an Orbitrap Mass Spectrometer

Isotope ratio (IR) determinations on individual particles can provide valuable information relative to the sample, including processing and dating, which could be valuable to geological and nuclear material analysis communities. In comparison to “bulk” measurements, in which all particle information is lost and homogenized within a sample, “particle” measurements allow for fingerprinting and can provide unique insights related to the sample’s nano- and micro- compositions. Furthermore, the complex nature of particles, with potential isobaric interferences from either the matrix or other elements within the same particle, poses a significant analytical challenge for conventional mass spectrometry platforms employed for elemental analysis due to their limited mass resolution. Presented here is the first demonstration of an ultrahigh resolution method for single particle (SP) isotopic analysis using the liquid sampling-atmospheric pressure glow discharge (LS-APGD) microplasma ionization source coupled to an Orbitrap mass spectrometer and FTMS Booster X2T acquisition/processing system. For proof of concept, well-characterized CeO 2 microparticles with a nominal diameter of 1.0 μm were analyzed at a mass resolution of ∼330,000. Important instrumental parameters were optimized to enable the detection of single particles. The 142 Ce/ 140 Ce ratio of individual particles and the population average were determined and compared to an SP inductively coupled plasma time-of-flight mass spectrometry (ICP-TOF-MS) analysis. The isotopic accuracy and precision were determined by two methods and found to be in good agreement with the SP-ICP-TOF-MS method, with the linear regression slope method providing a more accurate ratio, showing a ∼1.4% relative difference from the ratio determined from a particle digest. The encouraging performance of the method was further supported by a determined detection limit of 2.9 fg ( 142 Ce). The developed method is anticipated to overcome many of the challenges posed by isobaric interferences encountered in conventional mass spectrometry techniques when analyzing real-world samples for particle isotopic composition.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Assessing Gas-Phase Ion Reactivity of 50 Elements with NO and the Direct Application for 239 Pu in Complex Matrices Using ICP-MS/MS

Understanding the reactivity of metal cations with various reaction gases in ICP-MS/MS is important to determine the best gas to use for a given analyte/interference pair. In this study, nitric oxide (NO) was investigated as the reaction gas following previous experimental designs. The reactions with 50 elements were investigated to examine periodic trends in reactivity, validate theoretical modeling of reaction enthalpies as a method to screen reactant gases, and provide a baseline for potential in-line gas separation methods. ICP-MS/MS studies involving actinides are typically limited to Th, U and Pu, with analyses of Np and Am rarely reported in the literature. To date, only two previous methods have investigated the use of NO in ICP-MS/MS analyses. To showcase the utility of NO, a method was developed to measure 239 Pu in the presence of environmental matrix constituent and other actinides, like what could be expected from post-detonation debris, with no chemical separation prior to analysis. 239 Pu + was reacted to form 239 Pu 16 O + , eliminating interferences derived from the sample matrix by measuring 239 Pu + intensity at m/z = 255 ( 239 Pu 16 O + ). To validate NO for 238 U 1 H + interference removal in environmental matrices, standard reference materials were diluted to 1 mg per gram of solution and spiked to 0.05 pg/g of 239 Pu and 1 µg/g 238 U (Pu/U = 5 x 10 -8 ). Measured 239 Pu concentrations were within 6% of the spiked value. In conclusion, these results demonstrate that reliable 239 Pu measurements can be made at levels relevant to nuclear forensics without the need for extensive chemical matrix separation prior to analysis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Exploring the interference between the atmospheric and solar neutrino oscillation subamplitudes

The interference between the atmospheric and solar neutrino oscillation subamplitudes is said to be responsible for C P violation () in neutrino appearance channels. More precisely, is generated by the interference between the parts of the neutrino oscillation amplitude that are C P even and C P odd: even or odd when the neutrino mixing matrix is replaced with its complex conjugate. This is the interference term, as it gives a contribution to the oscillation probability, the square of the amplitude, which is opposite in sign for neutrinos and antineutrinos and is unique. For this interference to be nonzero, at least two subamplitudes are required. There are, however, other interference terms, which are even under the above exchange, and these are the C P conserving () interference terms. In this paper, we explore in detail these interference terms and show that they cannot be uniquely defined, as one can move pieces of the amplitude from the atmospheric subamplitude to the solar subamplitude and vice versa. This freedom allows one to move the interference terms around, but does not let you eliminate them completely. We also show that there is a reasonable definition of the atmospheric and solar subamplitudes for the appearance channels such that in neutrino disappearance probability there is no atmospheric-solar interference term. However, with this choice, there is a interference term within the atmospheric sector. Published by the American Physical Society 2025

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Neural simulation-based inference of the Higgs trilinear self-coupling via off-shell Higgs production

One of the forthcoming major challenges in particle physics is the experimental determination of the Higgs trilinear self-coupling. While efforts have largely focused on on-shell double- and single-Higgs production in proton-proton collisions, off-shell Higgs production has also been proposed as a valuable complementary probe. In this article, we design a hybrid neural simulation-based inference (NSBI) approach to construct a likelihood of the Higgs signal incorporating modifications from the Standard Model effective field theory (SMEFT), relevant background processes, and quantum interference effects. It leverages the training efficiency of matrix-element-enhanced techniques, which are vital for robust SMEFT applications, while also incorporating the practical advantages of classification-based methods for effective background estimates. We demonstrate that our NSBI approach achieves sensitivity close to the theoretical optimum and provide expected constraints for the high-luminosity upgrade of the Large Hadron Collider. While we primarily concentrate on the Higgs trilinear self-coupling, we also consider constraints on other SMEFT operators that affect off-shell Higgs production.

Ghosh, Aishik [Univ. of California, Irvine, CA (Un↗

Integrated photonic Galton board and its application for photon counting

The Galton board is a desktop probability machine traditionally used to visualize the principles of statistical physics from classical particles. Here, we demonstrate a photonic Galton board that enables on-chip observation of statistics from single-photon interference. The photonic Galton board consists of a directional coupler matrix terminated by an array of superconducting nanowire detectors to provide spatiotemporal resolution. This design also allows for photon-number-resolving capability, making it suitable for high-speed photon counting. Our results demonstrate the compatibility between single-photon detector array and photonic integrated circuits, paving the way for implementing on-chip large-scale quantum optics experiments and photonic quantum computing.

Qin, Hezheng (ORCID:0009000139348800)↗

Tip‐Enhanced Imaging and Control of Infrared Strong Light‐Matter Interaction

Optical antenna resonators enable control of light‐matter interactions on the nano‐scale via electron–photon hybrid states in strong coupling. Specifically, mid‐infrared (MIR) nano‐antennas coupled to saturable intersubband transitions in multi‐quantum‐well (MQW) semiconductor heterostructures allow for the coupling strength to be tuned through antenna resonance and field intensity. Here, in this study, tip‐enhanced nano‐scale variation of antenna‐MQW coupling across the antenna is demonstrated, with a spatially‐dependent coupling strength $g_{\textrm{aq}}$ varying from 73 (strong coupling) to 24 cm -1 (weak coupling). This behavior is modeled based on the spatially dependent local constructive and destructive interference between tip and antenna fields. Using a quantum‐mechanical density‐matrix model of the MQW system with its designed values of transition dipole moment, doping density, and population decay time, the picosecond IR pulse coupling to intersubband transitions and the associated tip induced strong‐field saturation effects are described. These results present a new regime of nonlinear IR light‐matter control based on the dynamic manipulation of quantum hybrid states on the nanoscale and in the infrared, with a perspective regarding extension to molecular vibrations.

Wang, Yueying↗

Photoredox Catalysis with Spin Magnetic Field Effects: A Scheme for Chiral Resolution

Quantities that break both mirror symmetry and time-reversal symmetry, such as the orbital angular momentum, are known to connect molecular chirality with an applied magnetic field. This concept has led to observations such as magneto-chiral dichroism and chirality-induced spin selectivity (CISS). However, being small, these effects often require additional amplification procedures such as flow chemistry to achieve bulk enantioseparation. In this work, we demonstrate how the magnetic field effect on photogenerated radical pairs, which also breaks time-reversal symmetry, can be harnessed for enantiopurification. Fundamental to this process is the collective decay of the singlet and triplet radical-pair states made possible by an applied magnetic field. Because opposite enantiomers exhibit spin-orbit coupling matrix elements of opposite signs, the singlet and triplet decay channels interfere constructively in one enantiomer. Meanwhile, molecules of the other enantiomer are funnelled into the first enantiomer through excited-state chirality inversion, achieving (dynamic kinetic) chiral resolution. Using an axially chiral binaphthyl derivative and a borane photosensitizer as prototype, we predict an appreciable enantiomeric excess (e.e.) of 90% to be possible at steady state, attained within hundreds of milliseconds when irradiated by a laser. Importantly, our analytical results showcase regimes of perfect enantioselectivity (100% e.e.), accessible by further chemical optimization of the photosensitizer for which general strategies are discussed. Altogether, this work illustrates a so-far untapped but powerful control knob for photoredox catalysis based on spin chemistry principles.

Magnetic properties↗

Element-specific ultrafast lattice dynamics in FePt nanoparticles

Light–matter interaction at the nanoscale in magnetic alloys and heterostructures is a topic of intense research in view of potential applications in high-density magnetic recording. While the element-specific dynamics of electron spins is directly accessible to resonant x-ray pulses with femtosecond time structure, the possible element-specific atomic motion remains largely unexplored. We use ultrafast electron diffraction (UED) to probe the temporal evolution of lattice Bragg peaks of FePt nanoparticles embedded in a carbon matrix following excitation by an optical femtosecond laser pulse. The diffraction interference between Fe and Pt sublattices enables us to demonstrate that the Fe mean square vibration amplitudes are significantly larger that those of Pt as expected from their different atomic mass. Both are found to increase as energy is transferred from the laser-excited electrons to the lattice. Contrary to this intuitive behavior, we observe a laser-induced lattice expansion that is larger for Pt than for Fe atoms during the first picosecond after laser excitation. This effect points to the strain-wave driven lattice expansion with the longitudinal acoustic Pt motion dominating that of Fe.

36 MATERIALS SCIENCE↗

Mass Spectrometer Transient Analysis

This software implements a complete preprocessing pipeline for transient mass spectrometry (MS) data collected during TAP (Temporal Analysis of Products) experiments. It is designed to extract chemically meaningful fluxes from overlapping ion signals by applying a calibrated defragmentation matrix and solving the resulting linear system using non-negative least squares (NNLS) regression. The core script, preprocess_mass_spec.py, performs the following operations: Gain correction: Applies amplifier gain scalars derived from inert-packed calibration pulses to normalize signal intensities across AMUs and acquisition settings. Background subtraction: Removes experiment baselines using user-defined time windows, ensuring compatibility with slow-diffusing species and preventing negative values that would interfere with NNLS. Options to subtract before and after defragmentation. Defragmentation: Constructs a fragmentation matrix A from zeroth moments of calibration pulses (equal molar gas:inert mixtures) and solves Ax=b at each time point, where b is the raw MS signal and x is the estimated species flux. The matrix is normalized to inert signals and accounts for instrument-specific fragmentation behavior. Pulse-mode handling: Supports both averaged and individual pulse modes, enabling statistical treatment of fluxes and calculation of standard deviations. Integration and output: Computes zeroth moments (integrated fluxes) and exports time-resolved and integrated data in CSV format, suitable for downstream kinetic modeling. The software is validated using both virtual TAP simulations (VTAP) and experimental data from propane dehydrogenation (PDH) on CrOx/Al2O3 catalysts. It preserves temporal resolution by applying NNLS point-by-point across the pulse duration (typically 6,000+ time slices per pulse), leveraging the linear superposition principle to reconstruct full flux profiles. The defragmented outputs are compatible with kinetic extraction methods such as the G and Y procedures, which are used to derive rate–concentration relationships from TAP data. The details of these validations are discussed in detail in the supporting manuscript and supporting information. Example data and output files are also included. The methodology is robust to experimental noise and drift, with calibration protocols that account for pulse size effects, MS aging, and inert gas normalization. The software is modular, reproducible, and tailored for high-throughput TAP-MS workflows in catalysis research.

Kristy, Stephen [Idaho National Laboratory (INL), ↗

Photon-odderon interference in exclusive χ c charmonium production at the Electron-Ion Collider

Exclusive C = + 1 scalar, axial-vector, and tensor quarkonium production in high-energy electron-proton scattering requires a C -odd t -channel exchange of a photon or a three-gluon ladder. We derive the expressions for the corresponding amplitudes. The relative phase of the photon vs three-gluon exchange amplitudes is determined by the sign of the light-front matrix element of the eikonal color current operator d a b c J + a J + b J + c at moderate x , and is not affected by small- x QCD evolution. Model calculations predict constructive interference, which is particularly strong for momentum transfer | t | ∼ 1 GeV 2 where the cross section for χ c J production exceeds that for pure photon exchange by up to a factor of 4. Exclusive χ c J electroproduction at the high luminosity Electron-Ion Collider occurs with well measurable rates and measurements of these processes should find evidence for the perturbative odderon exchange. We also compute the total electroproduction cross section as a function of energy and provide first estimates of the number of χ c J events per month at the Electron-Ion Collider design luminosity. Published by the American Physical Society 2024

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Quantitative 14 N NMR with Monte Carlo Uncertainty Analysis of Nitrate/Nitrite in Alkaline Nuclear Waste

While monitoring of nitrate and nitrite concentrations is important for managing corrosion in nuclear waste systems, existing analytical methods are hindered by turbidity, spectral interference, and delays from sample handling. Here, we demonstrate quantitative 14 N nuclear magnetic resonance (qNMR) spectroscopy as a direct, matrix-tolerant approach for nitrate and nitrite detection at natural abundance. Monte Carlo resampling was integrated into the workflow to quantify random error, establish precision–time tradeoffs, and separate noise-limited uncertainty from systematic bias arising from shimming, transmitter offset, or excitation pulse conditions. Quantification of nitrate and nitrite were validated in controlled alkaline matrix challenges and in 18-component Hanford-type simulants. These results establish 14 N qNMR as a practical, uncertainty-bounded tool for monitoring redox-active nitrogen species in chemically complex environments and provide a generalizable framework for quantitative analysis of quadrupolar nuclei.

Graham, Trent R. [Pacific Northwest National Labor↗

Spontaneous Formation of Single-Crystalline Spherulites in a Chiral 2D Hybrid Perovskite

In two-dimensional (2D) chiral metal-halide perovskites (MHPs), chiral organic spacers induce structural chirality and chiroptical properties in the metal-halide sublattice. This structural chirality enables reversible crystalline-glass phase transitions in (S-NEA) 2 PbBr 4 , a prototypical chiral 2D MHP where NEA + represents 1-(1-naphthyl)ethylammonium. Here, in this study, we investigate two distinct spherulite states of (S-NEA) 2 PbBr 4 , exhibiting either radial-like or stripe-like banded patterns depending on the annealing conditions of the amorphous film. Despite similarities in optical absorption and photoluminescence, the stripe-like, banded spherulite exhibits higher crystallinity and improved optical transparency compared to those of radial-like spherulite. X-ray nanoprobe measurements reveal tilting-angle modulations in the octahedral plane of stripe-like spherulites, correlating with the film’s surface geometry. Transfer matrix calculations indicate that the optical contrast in stripe-like patterns, seen in bright-field optical microscopy, arises from optical interference effects, differing from the contrast mechanism observed in polymer spherulites. Ultrafast carrier dynamics experiments suggest that the stripe-like spherulites resemble single crystals more closely than radial-like spherulites, while electrical conductivity measurements show enhanced charge carrier transport in stripe-like spherulites. These findings offer insights into MHP spherulite states with a single composition but different morphologies, previously observed only in polymers, highlighting their potential for optoelectronic applications.

36 MATERIALS SCIENCE↗