Search NASA⌕ Search

SEARCH · Search NASA

Results for “Measured Response”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Development and evaluation of a list mode neutron coincidence collar for spatial response measurements of fresh fuel assemblies

A traditional safeguards neutron coincidence counting system, the Neutron Coincidence Collar, has been modified to incorporate individual preamplifiers on each of its 18 3He tubes in active interrogation mode. When used with list mode data acquisition (LMDA) and analysis, a signal from each 3He tube can be recorded and analyzed to allow a spatial response measurement to be performed on an item based on count rate and 3He tube location within the system. The ultimate goal of this project is to demonstrate the capabilities of a list mode response matrix for the nondestructive assay of fresh nuclear fuel assemblies. To enable partial defect detection of fuel pin locations and absences within an assembly, the project aims to extend well-established correlated neutron analysis techniques on a preexisting Neutron Coincidence Collar by extracting a greater number of useful signatures from the system than are currently generated. LMDA, combined with the addition of multiple preamplifiers, facilitates this capability by increasing the number of simultaneous signals that can be measured; this allows an in-depth analysis of neutron coincidence events to determine a fissioning item’s location based on the measured doubles count rate in various channel logic coincidence combinations. All of this can be done from a single measurement pulse train in offline analysis, which is the major benefit provided by LMDA. Through various stages of development and testing, a Mirion Technologies model JCC-71 Neutron Coincidence Collar has been successfully retrofit with modern electronics designed in-house at Oak Ridge National Laboratory, matching preexisting JAB-01 electronics performance, while maintaining the original system footprint. This paper presents these various stages of development and experimental evaluation of the proof of concept system.

Moore, Angela S.↗

Standoff inspection using geometry-informed full-wavefield response measurements

A vibrometer may measure acoustic responses in portions of a structure along a scan path to acoustic excitation of the structure. A ranging device may measure distances to the portions of the structure along the scan path. A three-dimensional point cloud may be generated based on the acoustic responses in the portions of the structure and the distances to the portions of the structure. The three-dimensional point cloud may include points representing geometry of the portions of the structure. The points may be associated with the acoustic responses in corresponding portions of the structure. One or more properties of the structure may be determined based on an analysis of the three-dimensional point cloud.

Flynn, Eric Brian↗

Crystal response measurement of the x-ray transmission crystals used by the Imaging Spectroscopy Snout at the National Ignition Facility

The Imaging Spectroscopy Snout (ISS) used at the National Ignition Facility is able to simultaneously collect neutron pinhole images, 1D spatially resolved x-ray spectra, and time resolved x-ray pinhole images. To measure the x-ray spectra, the ISS can be equipped with up to four different transmission crystals, each offering different energy ranges from ∼7.5 to ∼12 keV and different resolutions. Characterizing and calibrating such instruments is of paramount importance in order to extract meaningful results from experiments. More specifically, we characterized different ISS transmission-type alpha-Quartz crystals by measuring their responses as a function of photon energy, from which we inferred the angle-integrated reflectivity for each crystal’s working reflections. These measurements were made at the Lawrence Livermore National Laboratory calibration station dedicated to the characterization of x-ray spectrometers. The sources used covered a wide x-ray range—from a few to 30 keV; the source diameter was ∼0.6 mm. The experimental results are discussed alongside theoretical calculations using the pyTTE model.

Dozieres, M. (ORCID:0000000286401459)↗

PV module spectral response measurements - Data and Resources

"This dataset includes spectral response curves for 12 commercial silicon module types that are deployed at SNL in Albuquerque. The modules chosen for evaluation were originally purchased by SNL for the PV Lifetime project (renamed to Systems Long-Term Evaluation [SLTE]). The majority of those modules are deployed outdoors for long-term evaluation, but several modules of each type were placed in storage for future comparison purposes. One stored module of each type was sent to NREL for the spectral response measurements. NREL used the recently developed Module Quantum Efficiency (QE) test bed. What makes this system unique is that it scans the entire module automatically, taking one or more measurements on each cell. Using the mean of these measurements at each wavelength leads to improvements in spectral mismatch correction and module power measurements but having the individual measurements also makes it possible to identify outlier cells, which could be useful for investigating underperforming modules. All measurements were performed nominally at 25°C"

14 SOLAR ENERGY↗

Method and system for microwave mixer phase response measurement

A system, method and apparatus for mixer phase response measurement comprises a vector network analyzer connectable to a device under test, an additional device connected to the analyzer the additional device configured to have an equal phase response to that of the device under test, a local oscillator connected to the device under test and the additional device, a series of switches connecting the device under test and the additional device to a vector voltmeter, and a reference generator connected to the vector voltmeter.

Frolov, Daniil↗

Global horizontal spectral irradiance and module spectral response measurements: an open dataset for PV research

This report describes the creation process and final content of a spectral irradiance dataset for Albuquerque, New Mexico accompanied by a set of spectral response measurements for modules deployed at the same location. The spectral irradiance measurements were made using horizontally mounted spectroradiometers; therefore, they represent global horizontal irradiance. The dataset combines non-continuous spectroradiometer and weather measurements from a two-year period into a single calendar year. The data files are accompanied by extensive metadata as well as example calculations and graphs to demonstrate the potential uses of this database. The spectral response measurements were carried out by the National Renewable Energy Laboratory using 12 commercial silicon modules types that are undergoing long-term evaluation at Sandia National Laboratories in Albuquerque.

14 SOLAR ENERGY↗

Impulse response measurements of fast scintillator-based current mode detectors

In this study, experimental measurements were performed to characterize the impulse response of seven different gamma ray detector prototypes being considered to be fielded as a current mode diagnostic for neutron-diagnosed subcritical experiments at the Nevada National Security Site (NNSS). For such experiments, the impulse response of the fielded detector is required to have a full-width half-maximum (FWHM) of approximately 5 ns or less and a low amplitude tail. Each of the detector prototypes evaluated in this work were selected based on the potential to meet this performance requirement. An impulse of bremsstrahlung x-rays created from 2 MeV electrons from the NNSS’s Transformational Diagnostics and Imaging, Los Alamos, linear accelerator was measured with each detector. The measured impulse response was evaluated for each detector configuration. A comparison of these impulse responses revealed a relationship between fast timing performance and scintillator material, geometry, surface reflectivity conditions, and photomultiplier tube (PMT) selection. The detector configuration yielding an impulse response with the shortest FWHM of 3.82 ± 0.11 ns and possessing a low amplitude tail was a 5-inch (12.7-cm) diameter, 5-inch (12.7-cm) height cylindrical EJ-399-17-VI liquid scintillator in a black-painted housing coupled to an Adit D798B 5-inch (12.7-cm) PMT by means of a 0.079-inch (0.2-cm) EJ-560 optical coupling pad.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Orbit response measurements with oscillating trajectories

Optical properties of components in a linac can be reconstructed from analysis of the orbit response matrix, composed from responses of BPMs to changes in currents of dipole correctors. An efficient way to record such response, discussed in this note, is to excite the corrector current with a sine wave and record its Fourier component of the BPM spectrum. Because of a narrow band of the excitation signal, response to multiple correctors can be recorded at the same time without significantly affecting the signal-to-noise ratio. For that, the correctors are oscillated at different frequencies, and the corresponding BPM Fourier components are recorded. In an ion (non-relativistic) linac, similar measurements can be performed for the longitudinal plane as well. Examples of measurements at the PIP2IT test linac are shown.

43 PARTICLE ACCELERATORS↗

Assessing impact of real-world aging on Cu-redox half cycles of a Cu-SSZ-13 SCR catalyst via transient response measurements and kinetic modeling

We report that the SCR reaction on Cu-SSZ-13 is a redox process consisting of a reduction half-cycle (RHC) and an oxidation half-cycle (OHC). Despite extensive efforts to understand hydrothermal aging and sulfur poisoning, the impact of real-world aging on the SCR activity of Cu-SSZ-13 has not been reported. This work employs a transient response methodology consisting of experiments and kinetic models to investigate the SCR redox cycles at intra-catalyst locations of commercial Cu-SSZ-13 monolith catalysts in their degreened and real-world aged states, in the temperature range of 200–450 °C. Moreover, H 2 -TPR, NH 3 -TPD, SO 2 -TPD, ICP-OES and solid-state NMR were performed to investigate the catalyst properties. Sulfur aging and dealumination caused by real-world exposure decreased the reducible Cu density and SCR performance. Real-world aging was found to selectively slow OHC more than RHC, mainly due to lower mobility of the Cu ions coordinated to sulfur-related species leading to decreased formation of Cu-dimers necessary for OHC.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Inverse modeling of circular lattices via orbit response measurements in the presence of degeneracy

The number and location of beam position monitors (BPMs) and steerers with respect to the quadrupoles in a circular lattice can lead to degeneracy in the context of fitting linear optics and extracting lattice information from measured closed orbits. Furthermore, the measurement uncertainties due to the imperfection of BPMs and steerers can be propagated by the fitting process in ways that prohibit the successful extraction of discrepancies between lattice elements in the real machine and their description in the corresponding model. We systematically studied the influence of the placement of BPMs and steerers on the reconstruction of linear optics and corresponding lattice information. The derivative of orbit response coefficients with respect to the quadrupole strengths, the Jacobian, is derived as an analytical formula. This analytical version of the Jacobian is used to further derive the theoretical limitations of fitting linear optics from closed orbits in terms of the placement of BPMs and steerers. It is further demonstrated that when evaluating the Jacobian during the fitting procedure, the analytical version can be used in place of the conventional finite-difference computation. This allows for greatly improved efficiency when computing the Jacobian during each iteration of the fitting procedure. The approach is tested with large-scale simulations and the findings are verified by measurement data taken on SIS18 synchrotron at GSI Helmholtz Centre for Heavy Ion Research. The presented methods are of general nature and can be applied to other accelerator lattices as well. The fitting procedure by using the analytical Jacobian is tested in conjunction with various methods for mitigating quasidegeneracy and the results agree with those obtained by using the conventional Jacobian via finite-difference approximation.

47 OTHER INSTRUMENTATION↗

Case study: Accounting for response measurement error in fitting a regression model

This article presents a case study motivated by a plot of data that suggested an emerging trend that the authors were faced with explaining. When the measurement error of the data is accounted for, it turns out there was no real trend. Furthermore, this article shows how to use a Bayesian modeling approach to account for the measurement error.

42 ENGINEERING↗

Integral Nuclear Data and Benchmarking Needs for Fusion Energy Systems

Fusion energy systems are currently being designed and optimized using radiation transport codes. To deal with the unique environment inside a fusion-based system, many of these designs incorporate novel materials able to withstand the high radiation fields, ensure adequate cooling and thermal protection, and produce tritium. Validation plays a vital role in building trust in the predictive power of these models and computational methods. Validation of a code consists of modeling documented real-world experiments and comparing the code-predicted response to the measured response. Adequate validation requires measured responses from real-world experiments, also known as integral data, that mimic the system being designed, including materials, impinging radiation, and temperature, among other variables. The most trusted integral data are experimental responses that have been through a rigorous benchmarking process that develops a recommended computational model and evaluates all experimental uncertainties. Finally, there are a few research groups around the world that have been producing integral data for fusion applications, but a substantial investment is needed to address the unique validation needs of the fusion community.

Fusion↗

High power density soft x-ray GaAs photodiodes with tailored spectral response

GaAs photodiode arrays have been designed for non-destructive monitoring of x-ray beam position in soft coherent beamline front ends in synchrotron light sources. A shallow p-on-n junction was employed to reduce the device photocurrent density to optimize the operation with beam power densities up to 20 W mm -2 , mainly coming from hard x-rays. With this approach, the photocurrent is primarily defined by the excess carriers generated by low-energy x-ray photons absorbed near the detector surface. The p–n junction structures were grown by molecular beam epitaxy and processed into 64-element linear photodiode arrays. The devices were characterized first in the visible range with a high-power Ar-ion laser and then tested in the soft and hard x-ray regions up to 10 keV at two beamlines of the National Synchrotron Light Source II. The responsivity was measured to be 0.16 A W -1 at 0.7 keV and 0.05 A W -1 at 6 keV in agreement with modeling. At higher x-ray energies the measured responsivity was lower than predicted in the framework of the carrier diffusion model; a possible explanation is discussed.

36 MATERIALS SCIENCE↗

Measuring thermomechanical response of large-format printed polymer composite structures via digital image correlation

Large-format additive manufacturing (LFAM) is a branch of additive manufacturing (AM) research with the ability to create large structures typically measuring several meters in scale. LFAM is advantageous for tooling applications, not only because it offers the ability to create complex geometries not easily made using subtractive manufacturing processes, but the cost savings of pelletized feedstock used by these systems result in larger parts printed at faster speeds than traditional AM systems. Fiber reinforced polymer (FRP) is a commonly used feedstock material in LFAM structures because it reduces the distortion experienced during printing. However, FRP introduces highly anisotropic thermomechanical properties and contributes to a nonhomogeneous microstructure that can result in critical distortion of dimensions during tooling. Measuring the global thermomechanical response of LFAM structures requires a more representative method that accounts for not only anisotropic properties but also the nonhomogeneous nature of the final part. This is where traditional techniques to measure thermomechanical response, such as thermomechanical analysis (TMA), fall short as they assume homogeneity. This study evaluated the coefficient of thermal expansion (CTE) of LFAM structures as measured by TMA as compared to a novel digital image correlation oven (DIC Oven) system. The LFAM structures were made from 20 % by weight carbon fiber reinforced acrylonitrile butadiene styrene (CF-ABS). TMA measurements showed significant variations in CTE across a single LFAM bead, confirming the need for a global technique that captures overall thermomechanical response. The CTE values measured using the DIC Oven compared well to average TMA values obtained from localized measurements across the sample. The DIC Oven was also used to quantify the effects of different layer orientations on thermomechanical properties, which cannot be easily captured using TMA. A predictive model was also developed by using localized TMA values across an LFAM bead to predict the overall thermomechanical response of an LFAM structure.

36 MATERIALS SCIENCE↗

Predicting System Response at Unmeasured Locations

Traditional techniques to derive dynamic specification for components have a great deal of uncertainty. One of the major sources of uncertainty is that the number of response measurements in the operational system environment is insufficient to determine the component motion. This inadequacy is due to logistical limitations for data recording in field testing and space limitations for accelerometers, strain gages and associated wiring. Available measurements are often some distance from the component and therefore do not represent component motion. Typical straight-line envelopes of these unrepresentative measurements guarantee an increase in the uncertainty. In this paper multiple methods are attempted to expand a sparse set of field test measurements on a system to responses of interest that cannot be measured in the field due to the limitations. Proof of concept is demonstrated on the Modal Analysis Test Vehicle (MATV). The responses of interest, known as “truth responses”, are measured in a system vibration environment along with an optimized sparse set of 30 field responses. Methods to expand the field responses to the truth responses are demonstrated by comparing the acceleration spectral density of the expanded response to the measured response. Two methods utilize a validated finite element model of the MATV. One is developed from purely experiment based frequency response functions of a laboratory pre-test. Finally, these approaches are designed to drastically reduce the uncertainty of the component in-service motion as a basis for developing specifications that are guaranteed to be conservative with a known (instead of unknown) conservatism.

42 ENGINEERING↗