Search NASA⌕ Search

SEARCH · Search NASA

Results for “Measurement by laser beam”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Determination of Cross-Sectional Area of Focused Picosecond Gaussian Laser Beam

Measurement of the waist diameter of a focused Gaussian-beam at the 1/e(sup 2) intensity, also referred to as spot size, is key to determining the fluence in laser processing experiments. Spot size measurements are also helpful to calculate the threshold energy and threshold fluence of a given material. This work reports an application of a conventional method, by analyzing single laser ablated spots for different laser pulse energies, to determine the cross-sectional area of a focused Gaussian-beam, which has a nominal pulse width of approx. 10 ps. Polished tungsten was used as the target material, due to its low surface roughness and low ablation threshold, to measure the beam waist diameter. From the ablative spot measurements, the ablation threshold fluence of the tungsten substrate was also calculated.

Ledesma, Rodolfo↗

Measurement of ion beam profiles in a superconducting linac with a laser wire

A laser wire ion beam profile monitor system has been developed at the Spallation Neutron Source accelerator complex. The laser wire system uses a single laser source to measure the horizontal and vertical profiles of a pulsed hydrogen ion (H{sup -}) beam along a 230 m long superconducting linac, which accelerates H{sup -} from 200 MeV to 1 GeV. In this paper, we describe the laser optics requirement for the system, the performance of the profile measurement, and the effects of laser parameters on the measurement reliability. The result provides a practical guideline for the development of a large-scale, operational, laser-based diagnostics in accelerator facilities.

43 PARTICLE ACCELERATORS↗

Refractive index measured by laser beam displacement at {lambda}=1064 nm for solvents and deuterated solvents

The refractive index of a liquid is determined with 0.0003 accuracy from measurements of laser beam displacement by a liquid-filled standard 10 mm spectrophotometer cell. The apparatus and methods are described and the results of measurements at {lambda}=1064 nm and T=25.0 deg. C for 30 solvents and deuterated solvents are presented. Several sources of potential systematic errors as large as 0.003 are identified, the most important being the curvature of the liquid cell windows. The measurements are analyzed accounting for the significant imperfections of the apparatus.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Beam Emittance Measurement with Laser Wire Scanners in the ILC Beam Delivery System

Accurate measurement of the beam phase-space is essential for the next generation of electron accelerators. A scheme for beam optics optimization and beam matrix reconstruction algorithms for the diagnostics section of the beam delivery system of the International Linear Collider based on laser-wire beam profile monitors are discussed. Possible modes of operation of the laser-wire system together with their corresponding performance are presented. Based on these results, prospects for reconstructing the ILC beam emittance from representative laser-wire beam size measurements are evaluated.

43 PARTICLE ACCELERATORS↗

Imprinting a Focused X-Ray Laser Beam to Measure Its Full Spatial Characteristics

The new generation of x-ray free-electron lasers opens up unique avenues for exploring matter under exotic and extreme conditions. Extensive spatial characterization of focused, typically (sub)micron-sized, laser beams is indispensable but, nevertheless, difficult to be accomplished due to excessive radiation intensities. Methods exist allowing indirect or semidirect focus characterization from a safe distance far from the focal point. Here, in this study, we present a direct method of in-focus numerical phase recovery exploiting multishot desorption imprints in poly(methyl methacrylate). Shapes of the imprints serve as input data for the newly developed code PhaRe (phase recovery), inspired by the iterative Gerchberg-Saxton algorithm. A procedure of dynamic input-output mixing guarantees that the algorithm always converges to a self-consistent paraxial Helmholtz equation solution, which is thereafter optimized for transverse spatial coherence. Very good agreement with single-shot ablation imprints in lead tungstate (PbWO 4 ) is found. The experiment is carried out at the Linac Coherent Light Source with a focused beam monochromatized at 800 eV. The results of the coherence optimization indicate that the act of monochromatization may have an effect on otherwise very good transverse coherence of free-electron laser beams.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Beam splitting target reflector based compensation for angular drift of laser beam in laser autocollimation of measuring small angle deviations

Beam splitting target reflector based compensation for the angular drift of laser beam in laser autocollimation is proposed in this article to improve the measurement accuracy and stability of small angle deviations. A beam splitting target reflector is used to replace the plane mirror in laser autocollimation to generate a reference beam when returning the measurement beam. The reference beam and measurement beam have the same angular drift, but have different sensitivities to the rotation angle of the reflector due to the unique characteristics of the reflector. Thus, the angular drift of laser beam in laser autocollimation can be compensated in real time by using the drift of reference beam. Experimental results indicate that an output stability of 0.085 arc sec in 2 h can be achieved after compensation. And a measurement accuracy of {+-}0.032 arc sec can be obtained over the range of {+-}1190 arc sec with an effective resolution of 0.006 arc sec. It is confirmed that the compensation method for the angular drift of laser beam is necessary for improving the measurement accuracy and stability in laser autocollimation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A spin-optoelectronic detector for the simultaneous measurement of the degree of circular polarization and intensity of a laser beam

Simultaneous measurement of the degree of circular polarization and intensity of a laser beam is essential in advanced photonic applications. However, it is not feasible with conventional helicity dependent detectors where an additional detector is needed to measure the intensity. Here, we report the development of a spin-optoelectronic detector that can measure the degree of circular polarization and the intensity of a laser beam simultaneously. The principle of operation of device is based on the two independent fundamental phenomena occurring in Au/InP hybrid structures, namely, Inverse Spin Hall Effect (ISHE) and the Photo-Voltaic (PV) Effect. The magnitude of ISHE and PV signals is simultaneously measured across the two pairs of contacts that are made on the top of device. No cross talk is observed between the two detectors made on the same chip. The all-electronic compact device is fast, operates at room temperature, and opens up the possibility of many applications in an integrated optoelectronic platform.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Magnetically Controlled Plasma Waveguide For Laser Wakefield Acceleration

An external magnetic field applied to a laser plasma is shown produce a plasma channel at densities relevant to creating GeV monoenergetic electrons through laser wakefield acceleration. Furthermore, the magnetic field also provides a pressure to help shape the channel to match the guiding conditions of an incident laser beam. Measured density channels suitable for guiding relativistic short-pulse laser beams are presented with a minimum density of 5 x 10{sup 17} cm{sup -3} which corresponds to a linear dephasing length of several centimeters suitable for multi-GeV electron acceleration. The experimental setup at the Jupiter Laser Facility, Lawrence Livermore National Laboratory, where a 1-ns, 150 J 1054 nm laser will produce a magnetically controlled channel to guide a < 75 fs, 10 J short-pulse laser beam through 5-cm of 5 x 10{sup 17} cm{sup -3} plasma is presented. Calculations presented show that electrons can be accelerated to 3 GeV with this system. Three-dimensional resistive magneto-hydrodynamic simulations are used to design the laser and plasma parameters and quasi-static kinetic simulations indicate that the channel will guide a 200 TW laser beam over 5-cm.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Beam profile measurement of a solar-pumped iodine laser

Beam profile measurements have been made as a function of time within the laser pulse and C2F5I pressure. Measurements indicate that the profile is determined directly by the optical excitation volume, produced by the solar simulator, and that media distortion plays a minor role compared to the build up of quenching species during the lasing pulse.

De Young, Russell J.↗

Laser beam manifold and particle photography system for use in fluid velocity measurements

A laser beam manifold and particle photography system has been developed for use in fluid velocity measurements. The laser manifold is a device which transforms a single laser beam into several uniform parallel beams. By orienting two manifolds mutually perpendicular, an optical grid can be formed which acts as a reference for fluid velocity measurements. This optical grid is for all practical purposes totally nonperturbing to the flow. Tracer particles moving in the plane of the grid are then photographed to yield fluid velocities that can be measured relative to the optical grid. System construction and theory are presented.

Owen, R. B.↗

Laser beam collimation using a phase conjugate Twyman-Green interferometer

This paper presents an improved technique for testing laser beam collimation using a phase conjugate Twyman-Green interferometer. The technique is useful for measuring laser beam divergence. It is possible using this technique to detect the defocusing of the order of one micrometer for a well corrected collimating lens. A relation is derived for the defocusing that can be detected by the phase conjugate interferometer.

Shukla, R. P.↗

Influence of laser beam size on measurement sensitivity of thermophysical property gradients in layered structures using thermal-wave techniques

The influence of the photothermal laser source beam size on the measurement sensitivity of layered systems using photothermal radiometry (PTR) is presented. Based on an appropriate theoretical model, widely different behaviors of the photothermal amplitude and phase in terms of combinations of thermophysical properties (i.e., thermal conductivity and thermal diffusivity) between a thin coating and the substrate are observed. The beam size effect on PTR measurement sensitivity is theoretically examined and experimentally demonstrated using a carbonitrided C1018 steel sample. The experimental results of using a variable size laser beam for the carbonitrided C1018 sample validate the theoretical prediction, in which an expanded beam exhibits a much larger magnitude change in both amplitude and phase as a function of frequency than measurements with a focused beam. The fitted thermal conductivity and thermal diffusivity based on the assumed industrially relevant range of effective hardness case depth gives the approximate range of the change in thermal conductivity and thermal diffusivity of C1018 steels after the carbonitriding process.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗