Search NASA⌕ Search

SEARCH · Search NASA

Results for “Medical compression”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Medical Image Compression Using a New Subband Coding Method

A recently introduced iterative complexity- and entropy-constrained subband quantization design algorithm is generalized and applied to medical image compression. In particular, the corresponding subband coder is used to encode Computed Tomography (CT) axial slice head images, where statistical dependencies between neighboring image subbands are exploited. Inter-slice conditioning is also employed for further improvements in compression performance. The subband coder features many advantages such as relatively low complexity and operation over a very wide range of bit rates. Experimental results demonstrate that the performance of the new subband coder is relatively good, both objectively and subjectively.

Kossentini, Faouzi↗

Dynamic Countermeasure Fabrics for Post-Spaceflight Orthostatic Intolerance

Aerospace orthostatic intolerance garments (OIG) have historically been pneumatic (e.g., NASA’s antigravity suit), an approach that inhibits mobility and requires connection to an air supply. Elastic compression garments, an alternative technology, are difficult to don/doff and cannot be worn in a noncompressive state, resulting in discomfort and usability challenges. This research evaluates a novel technology—contractile shape memory alloy (SMA) knitted actuators—that can enable low-profile, dynamic compression for an aerospace OIG. To characterize the functional capabilities of SMA knitted actuators, displacement control testing was conducted on 10 actuator samples with a range of geometric design parameters. Inactive (FI) and actuated forces (FA) were observed by repeatedly thermally cycling each sample at 0%, 15%, 30%, and 45% structural strain. Compression capabilities were approximated using medical compression hosiery standards and anthropometric data from a representative aerospace population (ANSUR 2012). Dynamic compression predictions reached 52 mmHg (single layer fabric) and 105 mmHg (double layer fabric) at the ankle. Low, inactive pressures (p, 20 mmHg) demonstrate that compression is controllable and can be dynamically increased upon actuation up to 33 mmHg in a single layer system and up to 67 mmHg in a double layer system. The results highlight the potential of SMA knitted actuators to enable low-profile, dynamic compression garments that can reach medically therapeutic pressures on an aerospace population to counteract OI symptoms. In addition to astronautic applications, this technology demonstrates widespread terrestrial medical and high-performance aircraft applicability.

Orthostatic intolerance↗

Mechanical Ventilator Milano (MVM): A Novel Mechanical Ventilator Designed for Mass Scale Production in Response to the COVID-19 Pandemics

We present here the design of the Mechanical Ventilator Milano (MVM), a novel mechanical ventilator designed for mass scale production in response to the COVID-19 pandemics, to compensate for the dramatic shortage of such ventilators in many countries. This ventilator is an electro-mechanical equivalent of the old, reliable Manley Ventilator. Our design is optimized to permit large sale production in short time and at a limited cost, relying on off-the-shelf components, readily available worldwide from hardware suppliers. Operation of the MVM requires only a source of compressed oxygen (or compressed medical air) and electrical power. The MVM control and monitoring unit can be connected and networked via WiFi so that no additional electrical connections are necessary other than the connection to the electrical power. At this stage the MVM is not a certified medical device. Construction of the first prototypes is starting with a team of engineers, scientists and computing experts. The purpose of this paper is to disseminate the conceptual design of the MVM broadly and to solicit feedback from the scientific and medical community to speed the process of review, improvement and possible implementation.

Galbiati, C.↗

Dictionary Approaches to Image Compression and Reconstruction

This paper proposes using a collection of parameterized waveforms, known as a dictionary, for the purpose of medical image compression. These waveforms, denoted as lambda, are discrete time signals, where y represents the dictionary index. A dictionary with a collection of these waveforms Is typically complete or over complete. Given such a dictionary, the goal is to obtain a representation Image based on the dictionary. We examine the effectiveness of applying Basis Pursuit (BP), Best Orthogonal Basis (BOB), Matching Pursuits (MP), and the Method of Frames (MOF) methods for the compression of digitized radiological images with a wavelet-packet dictionary. The performance of these algorithms is studied for medical images with and without additive noise.

Ziyad, Nigel A.↗

Dictionary Approaches to Image Compression and Reconstruction

This paper proposes using a collection of parameterized waveforms, known as a dictionary, for the purpose of medical image compression. These waveforms, denoted as phi(sub gamma), are discrete time signals, where gamma represents the dictionary index. A dictionary with a collection of these waveforms is typically complete or overcomplete. Given such a dictionary, the goal is to obtain a representation image based on the dictionary. We examine the effectiveness of applying Basis Pursuit (BP), Best Orthogonal Basis (BOB), Matching Pursuits (MP), and the Method of Frames (MOF) methods for the compression of digitized radiological images with a wavelet-packet dictionary. The performance of these algorithms is studied for medical images with and without additive noise.

Ziyad, Nigel A.↗

Space Flight Orthostatic Intolerance Protection

This paper summarizes investigations conducted on different orthostatic intolerance protection garments. This paper emphasizes on the engineering and operational aspects of the project. The current Shuttle pneumatic Anti-G Suit or AGS at 25 mmHg (0.5 psi) and customized medical mechanical compressive garments (20-30 mmHg) were tested on human subjects. The test process is presented. The preliminary results conclude that mechanical compressive garments can ameliorate orthostatic hypotension in hypovolemic subjects. A mechanical compressive garment is light, small and works without external pressure gas source; however the current garment design does not provide an adjustment to compensate for the loss of mass and size in the lower torso during long term space missions. It is also difficult to don. Compression garments that do not include an abdominal component are less effective countermeasures than garments which do. An early investigation conducted by the Human Adaptation and Countermeasures Division at Johnson Space Center (JSC) has shown there is no significant difference between the protection function of the AGS (at 77 mmHg or 1.5 psi) and the Russian anti-g suit, Kentavr (at 25 mmHg or 0.5 psi). Although both garments successfully countered hypovolemia-induced orthostatic intolerance, the Kentavr provided protection by using lower levels of compression pressure. This more recent study with a lower AGS pressure shows that pressures at 20-30 mmHg is acceptable but protection function is not as effective as higher pressure. In addition, a questionnaire survey with flight crewmembers who used both AGS and Kentavr during different missions was also performed.

Luty, Wei↗

Fast Lossless Compression of Multispectral-Image Data

An algorithm that effects fast lossless compression of multispectral-image data is based on low-complexity, proven adaptive-filtering algorithms. This algorithm is intended for use in compressing multispectral-image data aboard spacecraft for transmission to Earth stations. Variants of this algorithm could be useful for lossless compression of three-dimensional medical imagery and, perhaps, for compressing image data in general.

Klimesh, Matthew↗

NASA: Biomedical applications team

The status of projects involving the adaptation of NASA technologies for medical purposes is reviewed. Devices for the measurement of joint deformation of arthritic hands, the development of an artificial pancreas, provision of an auditory signal to avert epileptic seizures, are described along with the control of medication levels, a compressed air tank to supply power for field dentistry, and an electroencephalogram monitor. The use of the Lixiscope as a portable fluoroscope, thermal laminates for hand and foot warmers for patients with Raynaud's syndrome, and the use of absorptive coatings for instruments for controlling medication levels are described. The applicability of occupation health and safety practices to industry, computerized patient scheduling, impregnation of the common facial tissue with an agent for killing respiratory viruses, commercial applications of anthropometric data, and multispectral image analysis of the skin as a diagnostic tool are reviewed.

Source record↗

The novel Mechanical Ventilator Milano for the COVID-19 pandemic

This paper presents the Mechanical Ventilator Milano (MVM), a novel intensive therapy mechanical ventilator designed for rapid, large-scale, low-cost production for the COVID-19 pandemic. Free of moving mechanical parts and requiring only a source of compressed oxygen and medical air to operate, the MVM is designed to support the long-term invasive ventilation often required for COVID-19 patients and operates in pressure-regulated ventilation modes, which minimize the risk of furthering lung trauma. The MVM was extensively tested against ISO standards in the laboratory using a breathing simulator, with good agreement between input and measured breathing parameters and performing correctly in response to fault conditions and stability tests. The MVM has obtained Emergency Use Authorization by U.S. Food and Drug Administration (FDA) for use in healthcare settings during the COVID-19 pandemic and Health Canada Medical Device Authorization for Importation or Sale, under Interim Order for Use in Relation to COVID-19. Furthermore, following these certifications, mass production is ongoing and distribution is under way in several countries. The MVM was designed, tested, prepared for certification, and mass produced in the space of a few months by a unique collaboration of respiratory healthcare professionals and experimental physicists, working with industrial partners, and is an excellent ventilator candidate for this pandemic anywhere in the world

60 APPLIED LIFE SCIENCES↗

Digital mammography, cancer screening: Factors important for image compression

The use of digital mammography for breast cancer screening poses several novel problems such as development of digital sensors, computer assisted diagnosis (CAD) methods for image noise suppression, enhancement, and pattern recognition, compression algorithms for image storage, transmission, and remote diagnosis. X-ray digital mammography using novel direct digital detection schemes or film digitizers results in large data sets and, therefore, image compression methods will play a significant role in the image processing and analysis by CAD techniques. In view of the extensive compression required, the relative merit of 'virtually lossless' versus lossy methods should be determined. A brief overview is presented here of the developments of digital sensors, CAD, and compression methods currently proposed and tested for mammography. The objective of the NCI/NASA Working Group on Digital Mammography is to stimulate the interest of the image processing and compression scientific community for this medical application and identify possible dual use technologies within the NASA centers.

Clarke, Laurence P.↗

Improvements for Image Compression Using Adaptive Principal Component Extraction (APEX)

The issues of image compression and pattern classification have been a primary focus of researchers among a variety of fields including signal and image processing, pattern recognition, data classification, etc. These issues depend on finding an efficient representation of the source data. In this paper we collate our earlier results where we introduced the application of the. Hilbe.rt scan to a principal component algorithm (PCA) with Adaptive Principal Component Extraction (APEX) neural network model. We apply these technique to medical imaging, particularly image representation and compression. We apply the Hilbert scan to the APEX algorithm to improve results

Ziyad, Nigel A.↗

An Efficient, Lossless Database for Storing and Transmitting Medical Images

This research aimed in creating new compression methods based on the central idea of Set Redundancy Compression (SRC). Set Redundancy refers to the common information that exists in a set of similar images. SRC compression methods take advantage of this common information and can achieve improved compression of similar images by reducing their Set Redundancy. The current research resulted in the development of three new lossless SRC compression methods: MARS (Median-Aided Region Sorting), MAZE (Max-Aided Zero Elimination) and MaxGBA (Max-Guided Bit Allocation).

Fenstermacher, Marc J.↗

Multimode Data-Compression System

Data-compression system developed to satisfy need for high-speed, high-performance compression of data from sources as diverse as medical images, high-definition television images, audio signals, readouts from scientific instruments, and binary data files. Maximum data-transmission capability of communication channel or storage capacity of storage device multiplied by approximately compression ratio. Various combinations of lossless and lossy compression chosen to suit various data streams.

Fang, Wai-Chi↗

Comparison of Bystander Cardiopulmonary Resuscitation (BCPR) Performance in the Absence and Presence of Timing Devices for Coordinating Delivery of Ventilatory Breaths and Cardiac Compressions in a Model of Adult Cardiopulmonary Arrest

Astronaut crew medical officers (CMO) aboard the International Space Station (ISS) receive 40 hours of medical training during the 18 months preceding each mission. Part of this training ilncludes twoperson cardiopulmonary resuscitation (CPR) per training guidelines from the American Heart Association (AHA). Recent studies concluded that the use of metronomic tones improves the coordination of CPR by trained clinicians. Similar data for bystander or "trained lay people" (e.g. CMO) performance of CPR (BCPR) have been limited. The purpose of this study was to evailuate whether use of timing devices, such as audible metronomic tones, would improve BCPR perfomance by trained bystanders. Twenty pairs of bystanders trained in two-person BCPR performled BCPR for 4 minutes on a simulated cardiopulmonary arrest patient using three interventions: 1) BCPR with no timing devices, 2) BCPR plus metronomic tones for coordinating compression rate only, 3) BCPR with a timing device and metronome for coordinating ventilation and compression rates, respectively. Bystanders were evaluated on their ability to meet international and AHA CPR guidelines. Bystanders failed to provide the recommended number of breaths and number of compressions in the absence of a timing device and in the presence of audible metronomic tones for only coordinating compression rate. Bystanders using timing devices to coordinate both components of BCPR provided the reco number of breaths and were closer to providing the recommended number of compressions compared with the other interventions. Survey results indicated that bystanders preferred to use a metronome for delivery of compressions during BCPR. BCPR performance is improved by timing devices that coordinate both compressions and breaths.

Hurst, Victor, IV↗

Effect of lattice orientation on compressive properties of selective laser sintered nylon lattice coupons

As AM lattices become more popular in medical devices, it is important to consider how lattice design parameters affect the mechanical integrity and performance of a device. This research investigated the effect of lattice orientation on the compressive mechanical response of five common lattice geometries: Hexagonal Honeycomb (Hex), Diamond, Voronoi Tessellation Method (VTM), sheet-based Gyroid, and Face-Centered-Cubic (FCC). Samples were tested at two relative densities and eight orientations, printed in Nylon 12 (PA2200) on an EOS P396. The mechanical response was compared to simulated finite element analysis (FEA) response for Hex and FCC lattices. Hex lattices displayed significant orientation dependance. Diamond lattices demonstrated some orientation dependance when at a lower relative density. Gyroid, FCC, and VTM all displayed minimal orientation dependance. Increasing lattice relative density appeared to reduce anisotropy among tested orientations of all lattice geometries except Hex. FEA simulations were able to produce a trend response that matched the mechanical response trends based on the investigated orientations. Furthermore, these results support the need for multi axial lattice mechanical test considerations. It also bolsters the need for lattice FEA models to have a sufficient comparator when identifying “worst-case” lattice test scenarios.

36 MATERIALS SCIENCE↗

ACTS Satellite Telemammography Network Experiments

The Satellite Networks and Architectures Branch of NASA's Glenn Research Center has developed and demonstrated several advanced satellite communications technologies through the Advanced Communications Technology Satellite (ACTS) program. One of these technologies is the implementation of a Satellite Telemammography Network (STN) encompassing NASA Glenn, the Cleveland Clinic Foundation. the University of Virginia, and the Ashtabula County Medical Center. This paper will present a look at the STN from its beginnings to the impact it may have on future telemedicine applications. Results obtained using the experimental ACTS satellite demonstrate the feasibility of Satellite Telemammography. These results have improved teleradiology processes and mammography image manipulation, and enabled advances in remote screening methodologies. Future implementation of satellite telemammography using next generation commercial satellite networks will be explored. In addition, the technical aspects of the project will be discussed, in particular how the project has evolved from using NASA developed hardware and software to commercial off the shelf (COTS) products. Development of asymmetrical link technologies was an outcome of this work. Improvements in the display of digital mammographic images, better understanding of end-to-end system requirements, and advances in radiological image compression were achieved as a result of the research. Finally, rigorous clinical medical studies are required for new technologies such as digital satellite telemammography to gain acceptance in the medical establishment. These experiments produced data that were useful in two key medical studies that addressed the diagnostic accuracy of compressed satellite transmitted digital mammography images. The results of these studies will also be discussed.

Kachmar, Brian A.↗

Flow Measurements in Pressurized Helium Gas Cooling Channels: Rev. 1

Compressed helium gas is used to cool the NorthStar Medical Radioisotope (NMR) target system, also called the trident, chosen due to its superior heat transfer capabilities and its inability to react with Molybdenum-100 (Mo-100) during irradiation. To test the housing and NMR target stack at Los Alamos National Laboratory (LANL), two sets of helium gas flow loop facilities have been set-up and tested. One system is used for bench-top experiments to systematically investigate individual components of the NMR target, and the other, larger system is more representative of the system at NMR and is used for testing the full NMR target stack.

43 PARTICLE ACCELERATORS↗

Digital storage and analysis of color Doppler echocardiograms

Color Doppler flow mapping has played an important role in clinical echocardiography. Most of the clinical work, however, has been primarily qualitative. Although qualitative information is very valuable, there is considerable quantitative information stored within the velocity map that has not been extensively exploited so far. Recently, many researchers have shown interest in using the encoded velocities to address the clinical problems such as quantification of valvular regurgitation, calculation of cardiac output, and characterization of ventricular filling. In this article, we review some basic physics and engineering aspects of color Doppler echocardiography, as well as drawbacks of trying to retrieve velocities from video tape data. Digital storage, which plays a critical role in performing quantitative analysis, is discussed in some detail with special attention to velocity encoding in DICOM 3.0 (medical image storage standard) and the use of digital compression. Lossy compression can considerably reduce file size with minimal loss of information (mostly redundant); this is critical for digital storage because of the enormous amount of data generated (a 10 minute study could require 18 Gigabytes of storage capacity). Lossy JPEG compression and its impact on quantitative analysis has been studied, showing that images compressed at 27:1 using the JPEG algorithm compares favorably with directly digitized video images, the current goldstandard. Some potential applications of these velocities in analyzing the proximal convergence zones, mitral inflow, and some areas of future development are also discussed in the article.

NASA Discipline Cardiopulmonary↗