Search NASA⌕ Search

SEARCH · Search NASA

Results for “Mesh Tally”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Using Tally Values to Add a Third Dimension when Viewing Planar Mesh Tallies - Paper 95

Mesh tallies show a calculated quantity, such as radiation flux or dose rate, in cells of a rectangular, cylindrical, or spherical mesh. Mesh tallies are useful when the spatial distribution of the quantity is of interest. They are usually displayed in two dimensional (2D) plots with the tally values represented by color coding. Geometry outlines and/or contour lines may be included. Three dimensional (3D) views of rectangular tallies often show a set of tally planes within the geometry. We describe here a new 3D mesh tally plot where the third dimension of a rectangular mesh tally plane is determined by the tally value in each mesh cell. We refer to such plots as elevated mesh tally plots. These plots may aid in analysis and presentation of the results of a transport calculation. The results shown here were calculated with the Monte Carlo transport code MCNPX2.7. The plots were made with the White Rock Science visualization and geometry editing program Moritz. The elevated mesh tally plots have been implemented within Moritz. The elevation method is, at present, only applicable to rectangular mesh tallies. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

Monte Carlo mesh tallies based on a Kernel Density Estimator approach using integrated particle tracks

A new Monte Carlo mesh tally based on a Kernel Density Estimator (KDE) approach using integrated particle tracks is presented. We first derive the KDE integral-track estimator and present a brief overview of its implementation as an alternative to the MCNP fmesh tally. To facilitate a valid quantitative comparison between these two tallies for verification purposes, there are two key issues that must be addressed. The first of these issues involves selecting a good data transfer method to convert the nodal-based KDE results into their cell-averaged equivalents (or vice versa with the cell-averaged MCNP results). The second involves choosing an appropriate resolution of the mesh, since if it is too coarse this can introduce significant errors into the reference MCNP solution. After discussing both of these issues in some detail, we present the results of a convergence analysis that shows the KDE integral-track and MCNP fmesh tallies are indeed capable of producing equivalent results for some simple 3D transport problems. In all cases considered, there was clear convergence from the KDE results to the reference MCNP results as the number of particle histories was increased. (authors)

97 MATHEMATICS AND COMPUTING↗

$χ$-$MeRA$: Computationally efficient adaptive mesh refinement of Monte Carlo mesh based tallies

Here, the reactor physics community is always focused on reducing the computational time and memory required for simulations. $χ$-$MeRA$, which stands for flux-based-($χ$)-Mesh tally Refinement Adaptively, was built to reduce the computational time and memory required to solve the neutronics side of a multiphysics problem when compared to traditional methods for mesh based tallies in Monte Carlo (MC) simulations. $χ$-$MeRA$ couples a MC code with an adaptive mesh refinement (AMR) algorithm to take advantage of the accuracy of a MC code and the efficiency of an AMR algorithm. Also developed within $χ$-$MeRA$ was a set of metrics to assess the effects of the refinement on various parameters in the simulation space. For a plutonium sphere, $χ$-$MeRA$ shows a reduction in memory usage and computation time when compared to a fully refined mesh by a factor of 14.7 and 6.7, respectively. When compared to an unstructured mesh, improvement of 1.3 and 4.8 was achieved for memory usage and computation time. The development of $χ$-$MeRA$ helps solve the neutronics side of a multiphysics problem in a faster, more computationally efficient manner than traditional methods, and the final mesh created contains accurate results that can be passed onto the next physics code.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

SIMULTANEOUS OPTIMIZATION OF TALLIES; IN DIFFICULT SHIELDING PROBLEMS

Monte Carlo is quite useful for calculating specific quantities in complex transport problems. Many variance reduction strategies have been developed that accelerate Monte Carlo calculations for specific tallies. However, when trying to calculate multiple tallies or a mesh tally, users have had to accept different levels of relative uncertainty among the tallies or run separate calculations optimized for each individual tally. To address this limitation, an extension of the CADIS (Consistent Adjoint Driven Importance Sampling) method, which is used for difficult source/detector problems, has been developed to optimize several tallies or the cells of a mesh tally simultaneously. The basis for this method is the development of an importance function that represents the importance of particles to the objective of uniform Monte Carlo particle density in the desired tally regions. This method utilizes the results of a forward discrete ordinates solution, which may be based on a quick, coarse-mesh calculation, to develop a forward-weighted source for the adjoint calculation. The importance map and the biased source computed from the adjoint flux are then used in the forward Monte Carlo calculation to obtain approximately uniform relative uncertainties for the desired tallies. This extension is called forward-weighted CADIS, or FW-CADIS.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

KIPT ADS Target Cooling Analyses by MCNP/Fluent

This report presents multi-physics analyses of the target cooling system of the accelerator driven system (ADS) of the Kharkiv Institute of Physics and Technology (KIPT) using MCNP and Fluent computer programs. MCNP has been used to transport electrons, gammas, and neutrons, and to calculate the energy deposition in the target using a mesh-tally. The mesh-tally data have been imported in Fluent by a C subroutine that has been compiled and linked to Fluent as a user defined function. The KIPT ADS is in operation and Fluent used the CAD model from the manufacturing process of the target. The Fluent results for the reference case match very well the literature results obtained by STAR-CCM+ during the design phase. Other cases that differ from the reference one have been analyzed; in these cases, it is assumed a malfunction of the electron accelerator control or the primary water coolant pump. The target cooling system operates normally for all the analyzed cases except when the inlet water mass flow rate is decreased. If the water coolant mass flow decreases to 25%, the water maximum temperature exceeds the boiling point. However, the transient analysis showed that the target cooling system can operate for 180 seconds when the inlet water mass flow rate is decreased down by 50%.

42 ENGINEERING↗

Verification of the 3-Region Advanced Test Reactor MCNP Model

The verification of the 3-region homogenized fuel Advanced Test Reactor MCNP model. The 3-region model was compared to the 19-plate model found in the 94-CIC report. Flux tallies, energy deposition tallies, and quarter core mesh tallies were used to compare the two models. The 3-region model needed updating in order to make good comparisons between the models. The percent error from the flux and energy deposition tallies data shows that experiment positions inside the flux trap have higher errors than positions outside the fuel ring. The standard deviation data obtained from the mesh tallies shows that the two models agree within two standard deviations throughout the reactor. It is concluded that the model works adequately for what it is used for.

99 GENERAL AND MISCELLANEOUS↗

Verification of the 3-Region Advanced Test Reactor MCNP Model

The verification of the 3-region homogenized fuel Advanced Test Reactor MCNP model. The 3-region model was compared to the 19-plate model found in the 94-CIC report. Flux tallies, energy deposition tallies, and quarter core mesh tallies were used to compare the two models. The 3-region model needed updating in order to make good comparisons between the models. The percent error from the flux and energy deposition tallies data shows that experiment positions inside the flux trap have higher errors than positions outside the fuel ring. The standard deviation data obtained from the mesh tallies shows that the two models agree within two standard deviations throughout the reactor. It is concluded that the model works adequately for what it is used for.

99 GENERAL AND MISCELLANEOUS↗

Methods for Detector Placement and Analysis of Criticality Accident Alarm Systems

Determining the optimum placement to minimize the number of detectors for a criticality accident alarm system (CAAS) in a large manufacturing facility is a complex problem. There is typically a target for the number of detectors that can be used over a given zone of the facility. A study to optimize detector placement typically begins with some initial guess at the placement of the detectors and is followed by either predictive calculations of accidents at specific locations or adjoint calculations based on preferred detector locations. Within an area of a facility, there may be a large number of potential criticality accident sites. For any given placement of the detectors, the list of accident sites can be reduced to a smaller number of locations at which accidents may be difficult for detectors to detect. Developing the initial detector placement and determining the list of difficult accident locations are both based on the practitioner's experience. Simulations following fission particles released from an accident location are called 'forward calculations.' These calculations can be used to answer the question 'where would an alarm be triggered?' by an accident at a specified location. Conversely, 'adjoint calculations' start at a detector site using the detector response function as a source and essentially run in reverse. These calculations can be used to answer the question 'where would an accident be detected?' by a specified detector location. If the number of accidents, P, is much less than the number of detectors, Q, then forward simulations may be more convenient and less time-consuming. If Q is large or the detectors are not placed yet, then a mesh tally of dose observed by a detector at any location must be computed over the entire zone. If Q is much less than P, then adjoint calculations may be more efficient. Adjoint calculations employing a mesh tally can be even more advantageous because they do not rely on a list of specific difficult-to-detect accident sites, which may not have included every possible accident location. Analog calculations (no biasing) simply follow particles naturally. For sparse buildings and line-of-sight calculations, analog Monte Carlo (MC) may be adequate. For buildings with internal walls or large amounts of heavy equipment (dense geometry), variance reduction may be required. Calculations employing the CADIS method use a deterministic calculation to create an importance map and a matching biased source distribution that optimize the final MC to quickly calculate one specific tally. Calculations employing the FW-CADIS method use two deterministic calculations (one forward and one adjoint) to create an importance map and a matching biased source distribution that are designed to make the MC calculate a mesh tally with more uniform uncertainties in both high-dose and low-dose areas. Depending on the geometry of the problem, the number of detectors, and the number of accident sites, different approaches to CAAS placement studies can be taken. These are summarized in Table I. SCALE 6.1 contains the MAVRIC sequence, which can be used to perform any of the forward-based approaches outlined in Table I. For analog calculations, MAVRIC simply calls the Monaco MC code. For CADIS and FW-CADIS, MAVRIC uses the Denovo discrete ordinates (SN) deterministic code to generate the importance map and biased source used by Monaco. An adjoint capability is currently being added to Monaco and should be available in the next release of SCALE. An adjoint-based approach could be performed with Denovo alone - although fine meshes, large amounts of memory, and long computation times may be required to obtain accurate solutions. Coarse-mesh SN simulations could be employed for adjoint-based scoping studies until the adjoint capability in Monaco is complete. CAAS placement studies, especially those dealing with mesh tallies, require some extra utilities to aid in the analysis. Detectors must receive a minimum dose rate in order to alarm; therefore, a simple yes/no plot could be more useful to the analyst than a standard dose rate contour plot. Alarm systems that require several detectors to alarm simultaneously for a given accident would need to combine several yes/no plots in order to show accident sites where multiple detectors would be triggered. This could require a plot of 'areas of coverage' that is mapped over the building geometry. Several new utilities (which will be part of SCALE 6.2) were created to help with CAAS analysis.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Analysis of dpa rates in the HFIR reactor vessel using a hybrid Monte Carlo/deterministic method

The Oak Ridge High Flux Isotope Reactor (HFIR), which began full-power operation in 1966, provides one of the highest steady-state neutron flux levels of any research reactor in the world. An ongoing vessel integrity analysis program to assess radiation-induced embrittlement of the HFIR reactor vessel requires the calculation of neutron and gamma displacements per atom (dpa), particularly at locations near the beam tube nozzles, where radiation streaming effects are most pronounced. In this study we apply the Forward-Weighted Consistent Adjoint Driven Importance Sampling (FW-CADIS) technique in the ADVANTG code to develop variance reduction parameters for use in the MCNP radiation transport code. We initially evaluated dpa rates for dosimetry capsule locations, regions in the vicinity of the HB-2 beamline, and the vessel beltline region. We then extended the study to provide dpa rate maps using three-dimensional cylindrical mesh tallies that extend from approximately 12 below to approximately 12 above the axial extent of the core. The mesh tally structures contain over 15,000 mesh cells, providing a detailed spatial map of neutron and photon dpa rates at all locations of interest. Relative errors in the mesh tally cells are typically less than 1%.

Blakeman, Edward↗

Comparison Of Hybrid Methods For Global Variance Reduction In Shielding Calculations

For Monte Carlo shielding problems that calculate a mesh tally over the entire problem, the relative uncertainties computed for each voxel can vary widely. This can lead to unacceptably long run times in order to reduce the uncertainties in all areas of the problem to a reasonably low level. Hybrid methods using estimates from deterministic calculations to create importance maps for variance reduction in Monte Carlo calculations have been successfully used to optimize the calculation of specific tallies. For the global problem, several methods have been proposed that create importance maps that distribute Monte Carlo particles in such a way as to achieve a more uniform distribution of relative uncertainty across the problem. The goal is to compute a mesh tally with nearly the same relative uncertainties in the low flux/dose areas as in the high flux/dose areas. Methods based on only forward deterministic estimates and methods using both forward and adjoint deterministic methods have been implemented the SCALE/MAVRIC package and have been compared against each other by computing global mesh tallies on several representative shielding problems. Methods using both forward and adjoint estimates provide better performance for computing more uniform relative uncertainties across a global mesh tally.

FW-CADIS↗

Comparison of hybrid methods for global variance reduction in shielding calculations

For Monte Carlo shielding problems that calculate a mesh tally over the entire problem, the statistical uncertainties computed for each voxel can vary widely. This can lead to unacceptably long run times in order to reduce the uncertainties in all areas of the problem to a reasonably low level. Hybrid methods - using estimates from deterministic calculations to create importance maps for variance reduction in Monte Carlo calculations - have been successfully used to optimize the calculation of specific tallies. For the global problem, several methods have been proposed to create importance maps that distribute Monte Carlo particles in such a way as to achieve a more uniform distribution of relative uncertainty across the problem. The goal is to compute a mesh tally with nearly the same relative uncertainties in the low flux/dose areas as in the high flux/dose areas. Methods based on only forward deterministic estimates and methods using both forward and adjoint deterministic methods have been implemented in the SCALE/MAVRIC package and have been compared against each other by computing global mesh tallies on several representative shielding problems. Methods using both forward and adjoint estimates provide better performance for computing more uniform relative uncertainties across a global mesh tally. (authors)

97 MATHEMATICS AND COMPUTING↗

A Comparison of the FW-CADIS and MR-CADIS Variance Reduction Methods

The Consistent Adjoint Driven Importance Sampling (CADIS) method, which uses an adjoint deterministic estimate for making variance reduction parameters that optimize Monte Carlo (MC) shielding calculations, was introduced in 1998. This method was designed to optimize a single tally, typically an integrated response such as a detector count rate or a dose rate. Because both deterministic and stochastic methods are employed, CADIS is referred to as a hybrid method. In 2007, the forward-weighted CADIS (FW-CADIS) method was introduced to optimize several tallies at once, giving more uniform relative uncertainties among the tallies for both high-flux and low-flux areas of the problem. This method can be used for several small detectors, for semi-global problems (mesh tally over a large fraction of the problem), or for global problems (mesh tally over the entire problem). Optimization can be done for an integrated response such as a dose rate D(r) as a function of position, the total flux {phi}(r) as a function of position, or the space/energy flux {phi}(r,E). Both the CADIS and FW-CADIS methods have been in the MAVRIC sequence of SCALE for three versions (6.0 in 2009, 6.1 in 2011, and 6.2 in 2016). The ADVANTG package released in 2015 uses the CADIS and FW-CADIS methods to accelerate MCNP neutron/photon shielding calculations. In 2014, the multi-response CADIS (MR-CADIS) method was presented as a way to obtain even more uniform relative uncertainties for problems with multiple tallies than those obtained with FW-CADIS. The method does not use a forward deterministic calculation but instead uses one adjoint calculation for every tally to be optimized in the Monte Carlo calculation. This work compares the above methods.

42 ENGINEERING↗

Review of Hybrid (Deterministic/Monte Carlo) Radiation Transport Methods, Codes, and Applications at Oak Ridge National Laboratory

This paper provides a review of the hybrid (Monte Carlo/deterministic) radiation transport methods and codes used at the Oak Ridge National Laboratory and examples of their application for increasing the efficiency of real-world, fixed-source Monte Carlo analyses. The two principal hybrid methods are (1) Consistent Adjoint Driven Importance Sampling (CADIS) for optimization of a localized detector (tally) region (e.g., flux, dose, or reaction rate at a particular location) and (2) Forward Weighted CADIS (FW-CADIS) for optimizing distributions (e.g., mesh tallies over all or part of the problem space) or multiple localized detector regions (e.g., simultaneous optimization of two or more localized tally regions). The two methods have been implemented and automated in both the MAVRIC sequence of SCALE 6 and ADVANTG, a code that works with the MCNP code. As implemented, the methods utilize the results of approximate, fast-running 3-D discrete ordinates transport calculations (with the Denovo code) to generate consistent space- and energy-dependent source and transport (weight windows) biasing parameters. These methods and codes have been applied to many relevant and challenging problems, including calculations of PWR ex-core thermal detector response, dose rates throughout an entire PWR facility, site boundary dose from arrays of commercial spent fuel storage casks, radiation fields for criticality accident alarm system placement, and detector response for special nuclear material detection scenarios and nuclear well-logging tools. Substantial computational speed-ups, generally O(102-4), have been realized for all applications to date. This paper provides a brief review of the methods, their implementation, results of their application, and current development activities, as well as a considerable list of references for readers seeking more information about the methods and/or their applications.

97 MATHEMATICS AND COMPUTING↗

TRIPOLI-4{sup R} version 9 Shielding for the Shielding Community: Overview, Relevant Benchmarking for Shielding and Licensing Policy - Paper 49

This is a review paper of the Shielding only version of TRIPOLI-4. TRIPOLI-4 and TRIPOLI-4 S: TRIPOLI{sup R} represents a family of radiation transport codes using the Monte Carlo method (1,2). It has been continuously developed at CEA since the mid 60's. TRIPOLI-4{sup R}, being the fourth generation, has been developed starting from the mid 90's in C++. It tracks neutrons from 20 MeV down to 10{sup -5} eV, photons, electrons and positrons from 100 MeV to 1 keV, in 3D arbitrary geometries either in TRIPOLI{sup R} proprietary format or ROOT(4) format. It reads its continuous energy nuclear data from any evaluation in ENDF format, including but not limited to JEFF-3.1.1 and ENDF/BVII.0. It has various simulation modes, fixed-source (with or without fission), criticality, or both of them chained. A variety of tallies are available: averaged flux in a volume (track length and collision estimators), surface flux and current, point flux, reaction rates, deposited energy, dpa, pka, gamma spectroscopy, mesh tallies, tallies for criticality (k{sub eff}, beta eff, kinetic parameters). It provides the user with embedded response functions from IRDF and EAF as well. Several variance reduction techniques (3), including automated ones, make it particularly suitable to deep penetration problems (implicit capture, Russian roulette, exponential biasing with automatic estimation of the importance map). It may run in parallel, on single multi-core machines as well as heterogeneous networks of stations or massively parallel machines. It comes with productivity tools designed to speed-up the elaboration and verification of the input deck as well as the output analysis: 2D interactive display of geometry; 2D display of mesh tallies and collision sites; 3D input deck modeler; compatibility with ROOT tools to post-process TRIPOLI{sup R} outputs. Its V and V test base is made of more than 1000 internationally accepted benchmarks from ICSBEP and SINBAD (REPLICA, ASPIS, NESDIP) and covers all its application domains, including several shielding cases which will be detailed in the talk. TRIPOLI-4{sup R} is the reference Monte Carlo code for CEA, EDF, and also for AREVA for a number of applications. A 'Shielding-only' version has been designed to specifically answer the needs of the shielding community. It is distributed through the NEA Databank with a license for R and D, covering the fusion applications, whose terms are detailed in the paper.

61 RADIATION PROTECTION AND DOSIMETRY↗

Algorithmic Improvements to MCNP5 for High-Resolution Fusion Neutronics Analyses

Neutronics analyses of the ITER experimental fusion reactor rely on increasingly complex geometry models and estimates of energy-dependent neutron flux and radiation dose-rate distributions generated at ever higher resolutions. There are significant practical challenges with applying the Monte Carlo N-Particle (MCNP) continuous-energy transport code to high-resolution analyses. For models consisting of more than 100 000 surfaces and cells, geometry initialization can take several hours, thus slowing down model integration and transport analysis efforts. In multithreaded simulations, the amount of memory consumed by superimposed mesh tally data increases in proportion to the number of threads. This behavior limits either the tally resolution or the number of processor cores that can be utilized in the simulation. This paper describes algorithmic improvements that were implemented in a modified version of MCNP5 to overcome these limitations. These improvements are referred to as the Oak Ridge National Laboratory Transformative Neutronics (ORNL-TN) upgrade. Here, a comparison of the performance and memory usage of both MCNP5 and ORNL-TN on several relevant fusion neutronics models is presented. In these tests and in actual high-resolution neutronics analyses, ORNL-TN reduces geometry processing times from hours to a few seconds and increases in-memory mesh tally capacity from the order of 10 8 to 10 10 space-energy bins.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗