Fixed-Bed Columns for Adsorption of C2H2 in Metal Organic Frameworks for Hydrogen Recovery in Long-Duration Human Space Flight

To live and work in space, astronauts must have a breathable atmosphere. Current life support system technology utilizes the electrolysis of water to recover O2 as the main method of Oxygen recovery. In addition, the Sabatier Reaction is used to recover H2O from the CO2 produced by human respiration. The current atmosphere revitalization architecture onboard the International Space Station (ISS) has an efficiency of approximately 54% oxygen recovery. Therefore, these systems require substantial resupplies of water to sustain this environment, which make long-duration space flight missions, such as Martian transit, expensive and difficult. In order to support these missions, oxygen recovery must exceed 75-90% efficiency. Additional research has shown that with the addition of a Plasma Pyrolysis system, CH4 produced by the Sabatier reaction may be broken down into H2 and C2H2 and the H2 may be recycled. However, the Hydrogen must be separated from the highly volatile C2H2. There are many potential separation methods. A promising method includes the adsorption of the C2H2 into Metal Organic Frameworks (MOFs) using Vacuum Swing Adsorption. Due to the fragile nature of the MOFs and hazards present in producing C2H2, the columns must have a design that is compatible to both materials and that has the potential to operate in extraterrestrial environments. Successful design and testing of this Hydrogen separation system would allow the PPA to be fully integrated into the current oxygen regeneration system, resulting in a theoretical O2 recovery of 91.3%.

Hannah K Davis↗

Evaluation of Low-Energy Hydrogen Separation Method Using Metal-Organic Frameworks (MOFs) for Closed-Loop ECLSS Air Revitalization (CLEAR)

The State-of-the-Art (SOA) air revitalization architecture onboard the International Space Station (ISS) recovered approximately 50% of the oxygen (O 2 ) from metabolic carbon dioxide (CO 2 ) via the Sabatier process from 2011 to 2017. O 2 recovery is currently constrained by the limited availability of reactant hydrogen (H 2 ) preventing complete conversion of CO 2 to H 2 O. Increasing O 2 recovery within Closed-Loop ECLSS is essential to reducing resupply mass for long-duration manned missions; specifically focusing on water (H 2 O) which supplies H 2 for Sabatier via water electrolysis. Past ground test endeavors at Marshall Space Flight Center (MSFC) have attempted to recover H 2 from Sabatier-produced CH 4 using technologies such as carbon vapor deposition (CVD) and plasma pyrolysis. The byproducts of these technologies can act as a catalyst poison or reactor deadload to the Sabatier reactor. Hydrogen separation techniques must be utilized to maintain the Sabatier catalyst during gas recycling and must be scalable, non-energy intensive, and safe to operate in a habitation setting. Research indicated that metal-organic frameworks (MOFs) could meet these criteria and were tested for their capability to capture the various carbon-based gaseous products of CVD and plasma pyrolysis such as acetylene (C 2 H 2 ), ethylene (C 2 H 4 ), ethane (C 2 H 6 ), and carbon monoxide (CO) which would purify the hydrogen gas stream passing through the MOF. A sub-scale adsorption column was developed by Marshall Space Flight Center to test three MOF candidates against a synthetic gas mixture comprised of process-relevant carbonous gases and hydrogen to evaluate the separation capability of the MOFs. The results of the hydrogen separation capability, isothermal desorption capability, and demonstrated cyclic reuse of the MOF are presented in this paper.

Kagen Crawford↗

Closed Environment Air Revitalization System Based on Metal Organic Framework Adsorbents

This project utilized a systems engineering methodology to develop a vacuum swing adsorption system with full Labview automated control. The project was successful and provided students with an introduction to systems engineering and air revitalization. Specifically, two stainless steel adsorption beds were custom designed and manufactured and a sequence of computer controlled valves were used to deliver CO 2 laden, humid air, to the adsorbent where the CO 2 was removed from the air stream. Runs were completed using 13X zeolite and bed timing and switching was controlled by the computer based on the data output of a CO 2 detector. Adsorption runs using the MOF have not been completed upon the writing of this report; however, the MOF material is currently being synthesized and the runs will be completed upon receipt of the material. A follow up meeting with NASA has been tentatively planned to discuss the output of these experiments. Consistent with systems engineering practice, an end of project assessment of the class was conducted with the students and several items were realized. Specifically, the short period of performance of this grant makes it necessary to maintain a narrowly focused scope on the project such that multiple experiments after systems development (T&E) need to be limited to ensure timely completion of the proposed tasks. Also, procurement of parts may need to be moved forward in time to allow for delivery delays, and it may be necessary to request SDR, PDR, and CDR dates from NASA that are ahead of the NASA anticipated schedule. These types of lessons provided valuable to both the PI and the students and ultimately illustrate the necessity of proper systems engineering schedule risk assessment. The class met the objectives of the project and provided an introduction to systems engineering to undergraduate students. As a metric of that success, the lead engineer of the undergraduate design team acquired a job with an aerospace defense contractor, which he attributed to his knowledge of systems engineering concepts that were acquired via the X-Hab class.

T. Grant Glover↗

Simulation of Acetylene Adsorption Columns for Regenerative Life Support Systems

In oxygen recovery systems using Sabatier reactors, hydrogen (H 2 ) is the limiting factor in the Sabatier reaction. Aboard the International Space Station, electrolysis of water produces H 2 . However, additional H 2 can be provided by plasma pyrolysis of hydrocarbons, increasing the amount of H 2 available to the Sabatier reaction.

Regenerative Life Support↗