Search NASA⌕ Search

SEARCH · Search NASA

Results for “Micro Ion Spectrometer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Phase I (Final Report)

The focus of this proposal was the development of a new instrument capable of in-situ, spatially resolved, measurement of the energy spectra of ions in the edge of a tokamak plasma. The energy spectra of the ions determines the rates of sputtering and erosion of the plasma facing surfaces. The ion spectra in the edge is not easily determined spectroscopically and must be measured in situ since the ions are confined by the strong magnetic fields of the tokamak. Conventional energy analyzers are too large and expensive to install in multiple locations around the tokamak torus. The probes to be developed in this project are compact, low cost, and small enough to be placed inside of specially prepared wall tiles – essentially creating a “smart” plasma facing surface in a tokamak. Phase 1 of this project successfully demonstrated that two key elements of the instrument, the collimator and the energy analyzer, could be fabricated on a single silicon wafer and the combination functioned as designed when tested with an electron beam.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

INSPIRE Phase I Development

Sandia National Laboratories (Sandia) and Makel Engineering, Inc developed a pathway towards an advanced multi-modal sensor system suitable for in-situ analysis of exhaled volatile organic compounds (VOCs) for pilots, divers and field patients. Our proposed In-Mask Sensors for Physiological Investigation of Respiratory Exhalation - INSPIRE, will combine micro-gas chromatograph (microGC) and miniature ion mobility spectrometer (IMS) for detection of trace amounts of exhaled breath VOCs with miniature solid state sensors for inorganic compounds found in breath such as oxygen, carbon dioxide, moisture and the inert gases nitrogen, argon and helium. To develop clear developmental pathway towards that goal Sandia demonstrated a new version of its ion-mobility spectrometer detection technology for VOC detection, while Makel demonstrated detection of inorganics and concepts for mask integration. Sandia demonstrated detection of many compounds from the EPA TO-15 Test Mixture, which is representative of many classes of compounds found in air, and can be purchased as a gas standard from a variety of suppliers. The work demonstrated for phase I was sufficient to move the team into phase II of the program, where a full prototype unit will be developed. This CRADA provided clear value to the taxpayer by allowing a US small business to continue to phase II of a competitive STTR proposal for the Air Force. This process will help to transition Sandia’s technology into the marketplace to address a clear DoD requirement.

Moorman, Matthew↗

Micro-spectrometer for fusion plasma boundary measurements

In situ probes are being developed to make direct, spatially resolved measurements of the ion energy spectra in the edge of tokamak plasmas while being easily replaced and requiring minimal resources. The ion spectrometers will consist of a combined collimator and energy analyzer fabricated from silicon and mated to a detector to yield a form factor of approximately 2.0 cm × 1.5 cm × 0.2 cm. Results of fabrication and testing of the combined collimator and energy analyzer element are presented.

47 OTHER INSTRUMENTATION↗

Linear instabilities in the hot-ion regime in a high-field spherical tokamak

Abstract The present operating high-field compact spherical tokamak ST40 is an important step toward an ST-based fusion reactor (Gryaznevich and Asunta 2017 Fusion Eng. Des. 123 177; McNamara 2023 Nucl. Fusion 63 054002). Temperature and density profiles and their uncertainties in recent hot ion ST40 plasmas with central ion temperatures exceeding 8.6 keV, have been inferred using an integrated analysis of several diagnostics including line-of-sight integration and volume average measurements, as well as limited profile information from a charge-exchange-recombination spectrometer. A linear gyrokinetic stability analysis has been carried out to identify the most unstable micro-instabilities in these hot ion plasmas. In one of these plasmas, it is found that linear growth rates of both ion- and electron-scale ( k θ ρ s ⩾ 0.2 where k θ is the poloidal wavenumber and ρ s is the ion gyro-radius with sound speed) modes decrease from the edge toward the core of the plasma (i.e. from ρ = 0.8 to 0.3 where ρ is the square root of the normalized magnetic flux), while the change of linear growth rates at k θ ρ s < 0.2 is non-monotonic. In particular, at ρ = 0.3 no unstable mode was found at k θ ρ s > 5 , and about an order of magnitude reduction in the maximum linear growth rate in the ion-scale wavenumber range of 0.2 ⩽ k θ ρ s < 1 is seen at ρ = 0.3 compared with the ρ = 0.8 location. It is found through parametric scans that while the ion temperature gradient (ITG) mode/trapped electron mode (TEM) and kinetic ballooning mode (KBM)/kinetic shear Alfvén (KSA) mode are more important in the plasma core, ubiquitous mode (UM) is found to be the important ion-scale instability at ρ ⩾ 0.6 . At ρ = 0.8, two instabilities are found at the electron scale, with one being the typical electrostatic electron temperature gradient (ETG) mode at ρ e scale and beyond and the other being an unidentified low-real-frequency instability (at the intermediate scale between electron and ion gyroradii) which can propagate in the ion direction and is driven by ETG. The existence of UM at the ion scale and the low-real-frequency instability and ETG mode at the electron scale at ρ = 0.8 is supported by an extensive linear gyrokinetic stability analysis of another ST40 hot ion plasma in a wider parametric range, taking into account the uncertainties in the experimental profiles.

ubiquitous mode↗

CAMP@FLASH: an end-station for imaging, electron- and ion-spectroscopy, and pump–probe experiments at the FLASH free-electron laser

The non-monochromatic beamline BL1 at the FLASH free-electron laser facility at DESY was upgraded with new transport and focusing optics, and a new permanent end-station, CAMP, was installed. This multi-purpose instrument is optimized for electron- and ion-spectroscopy, imaging and pump–probe experiments at free-electron lasers. It can be equipped with various electron- and ion-spectrometers, along with large-area single-photon-counting pnCCD X-ray detectors, thus enabling a wide range of experiments from atomic, molecular, and cluster physics to material and energy science, chemistry and biology. Here, an overview of the layout, the beam transport and focusing capabilities, and the experimental possibilities of this new end-station are presented, as well as results from its commissioning.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Mass-Spectrometric Observation of C{sup +} Ions during Electrospray with In-Source Atomization

Carbon C{sup +} ions formed in a mass-spectrometric electrospray source with controlled in-source fragmentation and atomization interface have been observed for the first time. The measurements were performed in a special MI-20 LowMass mass spectrometer (MS-Bio LLC) using aqueous methanol solutions of lithium and beryllium salts. The peak of C{sup +} ions was substantially broadened as compared to the peaks of metal ions. A model is proposed that explains the formation of C{sup +} ions due to charge exchange immediately at the high-vacuum boundary near the skimmer output.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Micro-Thermionic Ionization Source for Chemical Detection

The major goal of this project was to develop an ionization-based detector that could be integrated into the portable gas chromatography systems currently produced by Defiant Technologies. This new detector would allow Defiant to analyze a broader range of analytes and enter new markets. There was also an interest in testing the new ionization source in an ion mobility spectrometer (IMS) that is produced by Sandia National Laboratories. Not only could this eliminate the need for a radioactive material in the IMS, it would offer Defiant the opportunity to add a whole new product line to their chemical analysis systems. Significant progress was made in the development of a thermionic ionization source (TIS) and detector. Using a MEMs heater was an attractive concept, but it proved to be an unfruitful approach because of the fragility of the devices at elevated temperatures. A rugged alternative heater was developed using nichrome wire and alumina tubes. These heaters are simple to make, and, for low quantity production, will be considerably cheaper to construct than MEMs devices. This work has provided a firm basis for follow-on projects. There is now a solid concept for constructing heater elements where, prior to this work, there was only the hope that MEMs heaters would work. In addition, the electrometer that was developed works better than the commercial rack-mounted system that was originally used in this study. Overcoming these two obstacles provides a clear technical approach for product development. There will be follow on efforts at Defiant Technologies to refine the development of the thermal ionization detector. Designs are being made to combine the TIS and electrometer electronics into a single package with a simple-to-replace TIS element. Further work will also focus on integrating this new detector into portable gas chromatography products and testing to optimize the performance.

47 OTHER INSTRUMENTATION↗

Perturbative analysis of low-frequency instabilities in high-field ST40 experiments

Abstract Linear and nonlinear perturbative analyses of low-frequency instabilities are presented for ST40 spherical torus high field plasmas, with simultaneous neutral beam heating due to two tangential sources at 25 keV and 55 keV. Initial plasma profiles on which the TRANSP and NUBEAM codes were based were obtained using an integrated analysis of several diagnostics including line-of-sight integrated and volume average measurements, as well as limited profile information from a charge-exchange-recombination spectrometer. Magnetohydrodynamics (MHD) analysis using the NOVA/NOVA-K codes suggests that the modes in the experiments are core-localized n = 1 eigenmodes with mixed acoustic and electromagnetic Alfvénic polarization. The global transport combined with the perturbative mode analysis indicates that there is greater tendency for bursty chirping response as the level of background micro-turbulence decreases in time and those predictions are shown to be consistent with the experimental data. This finding is interpreted in terms of the suppression of coherent phase-space structures that support chirping when the resonant fast ion dynamics is dominated by frequent stochastic, orbit-decorrelating events.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Compact high repetition rate Thomson parabola ion spectrometer

Here, we present the development of a compact Thomson parabola ion spectrometer capable of characterizing the energy spectra of various ion species of multi-MeV ion beams from >10 20 W/cm 2 laser produced plasmas at rates commensurate with the highest available from any of the current and near-future PW-class laser facilities. This diagnostic makes use of a polyvinyl toluene based fast plastic scintillator (EJ-260), and the emitted light is collected using an optical imaging system coupled to a thermoelectrically cooled scientific complementary metal–oxide–semiconductor camera. This offers a robust solution for data acquisition at a high repetition rate, while avoiding the added complications and nonlinearities of micro-channel plate based systems. Different ion energy ranges can be probed using a modular magnet setup, a variable electric field, and a varying drift-distance. We have demonstrated operation and data collection with this system at up to 0.2 Hz from plasmas created by irradiating a solid target, limited only by the targeting system. With the appropriate software, on-the-fly ion spectral analysis will be possible, enabling real-time experimental control at multi-Hz repetition rates.

47 OTHER INSTRUMENTATION↗

Vibrational signatures of HNO 3 acidity when complexed with microhydrated alkali metal ions, M + ∙(HNO 3 )(H 2 O) n =5 (M = Li, K, Na, Rb, Cs), at 20 K

The speciation of strong acids like HNO 3 under conditions of restricted hydration is an important factor in the rates of chemical reactions at the air-water interface. Here we explore the trade-offs in play when HNO 3 is attached to alkali ions (Li + -Cs + ) with four water molecules in their primary hydration shells. This is achieved by analyzing the vibrational spectra of the M + ∙(HNO 3 )(H 2 O) 5 clusters cooled to about 20 K in a cryogenic photofragmentation mass spectrometer. The local acidity of the acidic OH group is estimated by the extent of the red shift in its stretching frequency when attached to a single water molecule. Here, the persistence of this local structural motif (HNO 3 -H 2 O) in all of these alkali metal clusters enables us to determine the competition between the effect of the direct complexation of the acid with the cation, which acts to enhance acidity, and the role of the water network in the first hydration shell around the ions, which acts to counter (screen) the intrinsic effect of the ion. Analysis of the vibrational features associated with the acid molecule as well as those of the water network reveal how cooperative interactions in the micro hydration regime conspire to effectively offset the intrinsic enhancement of HNO 3 acidity afforded by attachment to the smaller cations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Open Source Visualization and Analysis Platform for 3D Reconstructions of Materials by Transmission Electron Microscopy

Three-dimensional characterization of materials at the nano- and meso-scale has become possible with transmission and scanning transmission electron microscopes (S/TEM). Its importance has extended to a wide class of nanomaterials such as hydrogen fuel cells, solar cells, industrial catalysts, new battery materials and semiconductor devices, as well as spanning high-tech industry, universities, and national labs. While capable instrumentation is abundant, this rapidly expanding demand for high-resolution tomography is bottlenecked by software that is instead tailored for lower-dose, biological applications and not optimized for higher-resolution materials applications. Existing tomography fails to utilize the chemical information provided by S/TEM spectrometers. To address this problem, this project delivered a scalable, fully functional, freely-distributable, open Source materials tomography package with a modern user interface that enables automated acquisition, alignment, and real-time reconstruction of raw tomography data, and provides advanced segmentation, three-dimensional chemical visualization and analysis optimized for materials applications. It has established an extendable framework capable of automation for high-throughput for the tomography of materials from data acquisition to visualization. Phase I and II delivered a full-featured, cross-platform, clean and integrated application for S/TEM materials tomography. It can read projection data from the microscope, with graphical tools for alignment of data, tomographic reconstruction, segmentation, and visualization of the reconstructed 3D volume. The entire pipeline can be saved to an XML state file, enabling fully reproducible data processing and analysis with a full Python environment for the development of custom algorithms, processing, and analysis requirements. Phase IIB extended the application to provide real-time tomographic reconstruction, "live updates" as data is processed, analysis of big data, and multi-channel tomography. Here, quantitative assessment of nanomaterials can occur as data is being recorded on a 3D visualization platform that accommodates additional information from multiple channels. We provide unmatched high-throughput tomography, where the complete tomographic pipeline from measurement to 3D visualization can occur rapidly. The project was extended to offer capabilities for micro-CT, X-ray, neutron, focused ion beam, atomic electron tomography and atom probe tomography. With over 600 transmission electron microscopes worldwide and approximately 50 coming online each year, the demand and impact of an open-source tomography tool is large. Significant opportunities exist in high-tech industry, universities, and national labs to enable or enhance three-dimensional imaging at the nanoscale and bring automated high-throughput approaches that will accelerate progress in materials characterization and metrology. The project supports a service based business model by enabling lab-specific acquisition and processing customization and integration-support and development that will be provided into Phase III and beyond.

36 MATERIALS SCIENCE↗

Single-Particle Isotopic Analysis Using the Liquid Sampling-Atmospheric Pressure Glow Discharge Microplasma Coupled to an Orbitrap Mass Spectrometer

Isotope ratio (IR) determinations on individual particles can provide valuable information relative to the sample, including processing and dating, which could be valuable to geological and nuclear material analysis communities. In comparison to “bulk” measurements, in which all particle information is lost and homogenized within a sample, “particle” measurements allow for fingerprinting and can provide unique insights related to the sample’s nano- and micro- compositions. Furthermore, the complex nature of particles, with potential isobaric interferences from either the matrix or other elements within the same particle, poses a significant analytical challenge for conventional mass spectrometry platforms employed for elemental analysis due to their limited mass resolution. Presented here is the first demonstration of an ultrahigh resolution method for single particle (SP) isotopic analysis using the liquid sampling-atmospheric pressure glow discharge (LS-APGD) microplasma ionization source coupled to an Orbitrap mass spectrometer and FTMS Booster X2T acquisition/processing system. For proof of concept, well-characterized CeO 2 microparticles with a nominal diameter of 1.0 μm were analyzed at a mass resolution of ∼330,000. Important instrumental parameters were optimized to enable the detection of single particles. The 142 Ce/ 140 Ce ratio of individual particles and the population average were determined and compared to an SP inductively coupled plasma time-of-flight mass spectrometry (ICP-TOF-MS) analysis. The isotopic accuracy and precision were determined by two methods and found to be in good agreement with the SP-ICP-TOF-MS method, with the linear regression slope method providing a more accurate ratio, showing a ∼1.4% relative difference from the ratio determined from a particle digest. The encouraging performance of the method was further supported by a determined detection limit of 2.9 fg ( 142 Ce). The developed method is anticipated to overcome many of the challenges posed by isobaric interferences encountered in conventional mass spectrometry techniques when analyzing real-world samples for particle isotopic composition.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Summertime Aerosol across the North Slope of Alaska Field Campaign Report

The Summertime Aerosol across the North Slope of Alaska U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) Climate Research Facility field campaign, a collaborative effort between the University of Michigan and Baylor University, was focused on chemically characterizing sources of summertime aerosol impacting the Utqiagvik (Barrow, NSA) and the Oliktok Point (AMF3) ARM sites. This campaign was co-funded by a grant from the National Oceanic and Atmospheric Administration (NOAA, PI: Kerri Pratt, Co-I: Rebecca Sheesley) titled “Assessment of Atmospheric Aerosols Resulting from Oil and Gas Extraction Activities near the North Slope of Alaska”. The ARM field campaign took place on the North Slope of Alaska (NSA) from August 21 to September 30, 2015 and August 12 to September 20, 2016, with filter sampling occurring both years at both the NSA Barrow and AMF3 Oliktok Point sites. Online intensive measurements occurred at Barrow in 2015 and at Oliktok Point in 2016, coordinated with the arrival of the ARM Aerosol Observing System (AOS) in August 2016 at Oliktok Point. During 2015, the University of Michigan deployed the newly constructed aerosol time-of-flight mass spectrometer (ATOFMS), as well as a microanalysis particle sampler (MPS) to collect particles for offline analysis by computer-controlled scanning electron microscopy with energy-dispersive x-ray spectroscopy (CCSEM-EDX). Unfortunately, an issue with the time-of-flight mass spectrometer on the ATOFMS limited the number of particles that produced mass spectra during the 2015 study. This issue was subsequently fixed for the 2016 deployment. During 2016, the ATOFMS was deployed to the AMF3 at the Oliktok Point field site, in addition to a micro-orifice uniform deposition impactor (MOUDI) to collect particles for offline analysis by CCSEM-EDX. Notably, these measurements, to our knowledge, represent the first real-time, single-particle chemical characterization (aerosol mixing state) measurements at Utqiagvik and Oliktok Point. Online aerosol measurements also included: PM2.5 (particulate matter <2.5 μm) black carbon mass concentrations (aethalometer; Baylor) and size-resolved (0.013-20 μm) number concentrations (scanning mobility particle sizer, SMPS, and aerodynamic particle sizer, APS; Michigan). Baylor conducted filter sampling at both the Utqiagvik and Oliktok Point locations during both intensive operational periods (IOPs). Baylor deployed a total suspended particulate matter (TSP) sampler to Oliktok Point, and continuous one-week samples were collected in 2015 for a total of seven samples; during 2016, continuous 3-7 day samples were collected, for a total of 13 filters. Baylor deployed a TSP sampler and a PM1.0 sampler at Utqiagvik, Alaska; continuous 4-7 day filter samples were collected in 2015 for a total of eight samples. To supplement this campaign, PI Sheesley had a simultaneous DOE ARM field campaign at Utqiagvik and Oliktok Point (https://www.arm.gov/research/ campaigns/amf2016bbc), the goal of which was to collected continuous one-week TSP samples at both sites from June 2016 to September 2017. These results provide better context in terms of annual trends and for year-to-year variability and a final report with data was already submitted by PI Sheesley for that project. Analysis by Baylor focuses on TSP samples because of the extremely low PM loading on the PM1.0 sampler. Michigan deployed a three-stage impactor (0.07-5 μm PM collection) at Utqiagvik and a 10-stage impactor (0.056-10 μm PM collection) at Oliktok Point, during the 2015 and 2016 campaigns, respectively.

Arctic processes, North Slope of Alaska, Barrow, O↗