Search NASA⌕ Search

SEARCH · Search NASA

Results for “Microfluidics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Perspectives on Microfluidics for the Study of Asphaltenes in Upstream Hydrocarbon Production: A Minireview

The utilization of microfluidics has generated deep insights into asphaltene precipitation mechanisms and oil–water emulsion stabilization. Agglomeration and precipitation of asphaltenes can cause flow assurance problems during the extraction and transportation of crude oil. Change in temperature, pressure, reservoir conditions, and solvents can change the local environment, leading to asphaltene precipitation. Understanding asphaltene properties and precipitation pathways becomes critical in devising mitigation methods, demulsifiers, and suitable conditions during hydrocarbon processing. Microfluidics has helped in high throughput measurement studies, understanding critical processing conditions, fast demulsifier screening, and the effect of solvent concentration on deposition, generating useful information for utilization at the point of resource extraction facilitating improved resource management. It has become possible to capture the porous, complex nature of reservoir formations and the interaction of chemicals during precipitation through integrated analytics and visualization studies available only through microfluidics. The use of droplet microfluidics, with optical microscopy and high-speed imaging to study the oil–water interface, has resulted in greater understanding of the role of asphaltenes in interfacial properties and emulsion stabilization. Here, this minireview highlights the crucial aspects of microfluidics that have been used to understand physicochemical behavior and dynamics of asphaltene deposition. Some of the unique devices have been presented focusing on the key elements of microfluidics design, fabrication, and analysis, as the insight obtained from microfluidics strongly depends on the device design and the controllability of the experimental parameters. Successful implementation of microfluidics for efficient and controlled experiments, short analysis time scales and rapid screening, and generation of high-quality, reliable data that convey asphaltene deposition issues and interface behavior in emulsions shows the importance of microsystems for advancing knowledge in hydrocarbon production and processing.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Liquid–Liquid Microfluidic Flows for Ultrafast 5-Hydroxymethyl Furfural Extraction

We study the effects of liquid–liquid flow patterns on the extraction of 5-hydroxymethyl furfural from the aqueous phase into an organic phase (methyl isobutyl ketone, ethyl acetate, and 2-pentanol) at ultrashort residence times of 0.2–20 s in a coiled capillary microchannel. Slug, droplet, slug-droplet, dispersed, parallel, annular, and irregular two-phase flow patterns are generated. We evaluate the extraction efficiency and the volumetric mass transfer coefficient via experiments and computational fluid dynamics (CFD). The CFD predictions are in quantitative agreement with the experimental data. The convective and diffusive contributions to the mass transfer of different flow patterns are analyzed. For all solvent pairs, the extraction efficiency varies irregularly with increasing flow rate due to changes in the mass transfer mechanism caused by a transition between flow regimes. Overall, we demonstrate >90% extraction efficiencies with high volumetric mass transfer coefficients ranging from 0.006 to 2.17 s–1. Furthermore, a merit index is defined to assess the trade-off between the fast mass transfer and the pressure drop in biphasic microchannels. In general, the mass transfer rate increases significantly at high flow rates at the expense of a high-pressure drop. Furthermore, the ethyl acetate/water irregular flow pattern is optimal due to a large throughput, extraction efficiency, and mass transfer coefficient, with a minimal pressure drop.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Enhanced Stability and Sensitivity for CA-125 Detection Under Microfluidic Shear Flow Using Polyethylene Glycol-Coated Biosensor

The microfluidic-based point-of-care (POC) diagnostic tool has garnered significant interest in recent years, offering rapid and cost-effective disease detection. There is a growing trend toward integrating microfluidic platforms with biosensors, aligning lab-on-a-chip technologies with POC diagnostic devices. Despite numerous efforts to incorporate biosensors into microfluidic systems, researchers have performed very limited investigations on the stability of biomarker detection when biosensors operate under microfluidic shear flow conditions. Gold nanoparticles (AuNPs) are a widely employed material in capacitive biosensors for antibody immobilization and sensitivity enhancement. However, AuNPs have limitations in providing stable detection of biomarkers within microfluidic shear flow due to their agglomeration nature. This study addresses these limitations by employing 2 kDa polyethylene glycol (PEG) as an intermediate biofunctional layer to immobilize CA-125 antibodies on gold-interdigitated electrodes for the stable and accurate detection of CA-125 antigens. The stabilities and sensitivities of AuNPs and PEG-coated biosensors are evaluated under both static drop and microfluidic shear flow conditions for CA-125 antigen detection. The experimental results demonstrate a capacitive signal response (5660 pF at 10 kHz) 2.2 times higher using the PEG-coated biosensor than the signal (2551 pF at 10 kHz) measured by the AuNP-coated biosensor in the detection of CA-125 antigen–antibody conjugation under static drop conditions, indicating the higher sensitivity of the PEG-coated biosensor. Additionally, the PEG-coated biosensor exhibits better consistency for the CA-125 antigen detection between static drop and microfluidic shear flow conditions (Cp decrease in percentage (ΔCp%↓) = 2.9% at 10 kHz) compared to the electrical signals measured using the AuNP-coated biosensor (ΔCp%↓ = 32.4% at 10 kHz), which suggests that the PEG-coated biosensor demonstrates higher stability for CA-125 antigen detection under microfluidic shear flow conditions. With these significant improvements brought by the PEG-coated biosensor, especially under microfluidic conditions, a substantial hurdle in developing electrical biosensors for POC diagnostic applications has been overcome, expediting further advancements in the field.

36 MATERIALS SCIENCE↗

Perspectives on Polyolefin Catalysis in Microfluidics for High-Throughput Screening: A Minireview

Polyolefins are the largest produced plastics in the world which traditionally employ continuous stirred tank reactors and fluidized bed reactors for commercial production. The operating condition, reaction kinetics, and molecular interactions inside the reactor strongly affect the polyolefin properties, which require stringent process control in conventional procedures. Understanding the catalytic pathway, behavior of polymer particles and effect of reactor conditions are essential for designing specific polymer properties, namely the molecular weight, chain length, polydispersity, etc. Microfluidics can play a significant role in designing polymers tailored to the user needs. Smaller channel dimensions help obtain uniform reaction conditions over the length of the microfluidic reactor in a controlled environment. With real-time monitoring techniques in microfluidics, even single particle growth of polymer can be studied to understand the parameters affecting the polymer properties. High throughput microfluidics can help catalyst screening in a short duration with less consumption of reagents generating less waste. When supplemented with efficient machine learning algorithms, automated high throughput microfluidics has the potential to rapidly optimize the process and develop new knowledge even with a limited data set. When trained on data sets generated using microfluidic experiments that are designed efficiently with working knowledge of the process, machine learning algorithms can provide the relationship between the multivariable parameters space and polymer properties, which is not possible with the traditional statistical methods and interpolation techniques. Here, the rise in the utilization of microfluidics, with the advancement of machine learning algorithms, for polyolefin catalysis, highlights the importance of microfluidics for catalyst discovery, parameter optimization, and understanding reaction pathway for producing polymers with specific properties for specialized applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

High-temperature high-pressure microfluidic system for rapid screening of supercritical CO 2 foaming agents

CO 2 foam helps to increase the viscosity of CO 2 flood fluid and thus improve the process efficiency of the anthropogenic greenhouse gas’s subsurface utilization and sequestration. Successful CO 2 foam formation mandates the development of high-performance chemicals at close to reservoir conditions, which in turn requires extensive laboratory tests and evaluations. This work demonstrates the utilization of a microfluidic reservoir analogue for rapid evaluation and screening of commercial surfactants (i.e., Cocamidopropyl Hydroxysultaine, Lauramidopropyl Betaine, Tallow Amine Ethoxylate, N,N,N' Trimethyl-N'-Tallow-1,3-diaminopropane, and Sodium Alpha Olefin Sulfonate) based on their performance to produce supercritical CO 2 foam at high salinity, temperature, and pressure conditions. The microfluidic analogue was designed to represent the pore sizes of the geologic reservoir rock and to operate at 100 °C and 13.8 MPa. Values of the pressure drop across the microfluidic analogue during flow of the CO 2 foam through its pore network was used to evaluate the strength of the generated foam and utilized only milliliters of liquid. The transparent microfluidic pore network allows in-situ quantitative visualization of CO 2 foam to calculate its half-life under static conditions while observing if there is any damage to the pore network due to precipitation and blockage. The microfluidic mobility reduction results agree with those of foam loop rheometer measurements, however, the microfluidic approach provided more accurate foam stability data to differentiate the foaming agent as compared with conventional balk testing. The results obtained here supports the utility of microfluidic systems for rapid screening of chemicals for carbon sequestration or enhanced oil recovery operations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Continuous Counter‐Current Microfluidic Liquid–Liquid Extraction Achieved Using a Pair of Wettable Screen Meshes

Continuous counter‐current microfluidic liquid–liquid extraction performs separations by flowing immiscible liquids in opposing directions within a single flow channel. In principle, this flow arrangement enables a large number of theoretical separation units in a small footprint, without using interstage valving, pumping, and phase separation. Despite its potential for excellent separation performance, this microfluidic scheme rarely appears in literature due to the requirement for capillary forces to be greater than hydrodynamic forces for stable flow. We present a novel microfluidic device and flow approaches that overcome this force‐balance challenge, enabling stable, long‐duration continuous counter‐current flow. Additionally, we cover a suite of methodologies for quantifying the performance of the microfluidic device, revealing the number of theoretical equilibrium stages achieved. The enabling technologies include a woven mesh screen‐based microfluidic device architecture that is easily fabricated outside of a clean room, surface functionalization strategies to promote conjugate (organic/aqueous) wettability, flow approaches to eliminate bubbles and carryover, and computer‐aided flow automation with optical measurement of extraction performance. The reported experiments lasted for over 36 h, terminated only at experiment conclusion, where the device still exhibited good performance. Automated Raman spectroscopy was used for solute quantitation of the ternary system tert‐butanol in a toluene/water matrix, a ternary system that was specifically chosen to analyze the device's performance with a small solute partition ratio and to enable in‐line Raman measurements of solute concentrations in both phases. The microfluidic device possessed a 55 mm contact length and a 38.5 µL internal volume. During counter‐current flow, we observed approximately 37 equilibrium stages (37 ± 13) based on a best‐fit of the solute fraction remaining in the aqueous phase using a Kremser Group Method analysis.

36 MATERIALS SCIENCE↗

Aerosol jet printing of surface acoustic wave microfluidic devices

Abstract The addition of surface acoustic wave (SAW) technologies to microfluidics has greatly advanced lab-on-a-chip applications due to their unique and powerful attributes, including high-precision manipulation, versatility, integrability, biocompatibility, contactless nature, and rapid actuation. However, the development of SAW microfluidic devices is limited by complex and time-consuming micro/nanofabrication techniques and access to cleanroom facilities for multistep photolithography and vacuum-based processing. To simplify the fabrication of SAW microfluidic devices with customizable dimensions and functions, we utilized the additive manufacturing technique of aerosol jet printing. We successfully fabricated customized SAW microfluidic devices of varying materials, including silver nanowires, graphene, and poly(3,4-ethylenedioxythiophene) polystyrene sulfonate (PEDOT:PSS). To characterize and compare the acoustic actuation performance of these aerosol jet printed SAW microfluidic devices with their cleanroom-fabricated counterparts, the wave displacements and resonant frequencies of the different fabricated devices were directly measured through scanning laser Doppler vibrometry. Finally, to exhibit the capability of the aerosol jet printed devices for lab-on-a-chip applications, we successfully conducted acoustic streaming and particle concentration experiments. Overall, we demonstrated a novel solution-based, direct-write, single-step, cleanroom-free additive manufacturing technique to rapidly develop SAW microfluidic devices that shows viability for applications in the fields of biology, chemistry, engineering, and medicine.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Automated control of microfluidic devices based on machine learning

A system is provided to automatically monitor and control the operation of a microfluidic device using machine learning technology. The system receives images of a channel of a microfluidic device collected by a camera during operation of the microfluidic device. Upon receiving an image, the system applies a classifier to the image to classify the operation of the microfluidic device as normal, in which no adjustment to the operation is needed, or as abnormal, in which an adjustment to the operation is needed. When an image is classified as normal, the system may make no adjustment to the microfluidic device. If, however, an image is classified as abnormal, the system may output an indication that the operation is abnormal, output an indication of a needed adjustment, or control the microfluidic device to make the needed adjustment.

Giera, Brian↗

Controlling matric potential in microfluidics to examine microbial dynamics in unsaturated porous media

The use of microfluidics for the study of soil microbial ecology is an emerging field. Most microfluidic studies of biological systems, however, have been performed under fully saturated conditions that are not representative of natural soil. Therefore, while microfluidics offer many unique capabilities that other methodologies cannot, they are not currently suited to address the effects of matric potential, an important variable defining the microbial moisture niche. Here, a methodology is presented that allows the user to control the aqueous conditions within microfluidic networks by manipulating matric potential using a hanging water column. The method relies on hydrophilic surface treatment of the microfluidic device using polyvinyl alcohol (PVA) and incorporating a bed of small pores at the network boundaries, which serve as a porous ceramic plate analogue (PPA). The method was validated on a simple capillary bundle and then on a more complex pore network. A water retention curve, exhibiting hysteresis, was generated for the pore network over a narrow matric potential range of 0 to – 5 kPa. Both the drainage and wetting curves were reproducible, as were the spatial configuration and the number of fragmented moisture niches in the pore network, particularly on the drainage curve. In contrast, the wetting curve exhibited greater variability in spatial configuration due to the “ink bottle effect,” where capillarity was interrupted by wider pore bodies. Ultimately, the methodology provides realistic pore-scale moisture conditions that can be easily manipulated and maintained, enabling new opportunities to explore soil biophysics and microbial biogeography in unsaturated porous media. As a brief example, images showing the localization of fluorescently tagged Pantoea sp. YR343 at −4.3 kPa are presented, highlighting bacterial distributions in water films and air-water interfaces.

59 BASIC BIOLOGICAL SCIENCES↗

Robotic automation of droplet microfluidics

Droplet microfluidics enables powerful analytic capabilities but often requires workflows involving macro- and microfluidic processing steps that are cumbersome to perform manually. Here, we demonstrate the automation of droplet microfluidics with commercial fluid-handling robotics. The workflows incorporate common microfluidic devices including droplet generators, mergers, and sorters and utilize the robot's native capabilities for thermal control, incubation, and plate scanning. The ability to automate microfluidic devices using commercial fluid handling will speed up the integration of these methods into biological workflows.

59 BASIC BIOLOGICAL SCIENCES↗

Fungi-on-a-Chip: microfluidic platforms for single-cell studies on fungi

Abstract This review highlights new advances in the emerging field of ‘Fungi-on-a-Chip’ microfluidics for single-cell studies on fungi and discusses several future frontiers, where we envisage microfluidic technology development to be instrumental in aiding our understanding of fungal biology. Fungi, with their enormous diversity, bear essential roles both in nature and our everyday lives. They inhabit a range of ecosystems, such as soil, where they are involved in organic matter degradation and bioremediation processes. More recently, fungi have been recognized as key components of the microbiome in other eukaryotes, such as humans, where they play a fundamental role not only in human pathogenesis, but also likely as commensals. In the food sector, fungi are used either directly or as fermenting agents and are often key players in the biotechnological industry, where they are responsible for the production of both bulk chemicals and antibiotics. Although the macroscopic fruiting bodies are immediately recognizable by most observers, the structure, function, and interactions of fungi with other microbes at the microscopic scale still remain largely hidden. Herein, we shed light on new advances in the emerging field of Fungi-on-a-Chip microfluidic technologies for single-cell studies on fungi. We discuss the development and application of microfluidic tools in the fields of medicine and biotechnology, as well as in-depth biological studies having significance for ecology and general natural processes. Finally, a future perspective is provided, highlighting new frontiers in which microfluidic technology can benefit this field.

59 BASIC BIOLOGICAL SCIENCES↗

INVESTIGATION OF ROCK-FLUID INTERACTIONS USING GEOMATERIAL MICROFLUIDICS

Illite and Illite-Smectite clays are reportedly the Caney Shale's most prevalent clay minerals. The swelling and fines migration of clays may occur when water-based fluids contact the clay minerals. This may result in the reduction of pore space and permeability, and wettability alteration. Therefore, we quantified the swelling potentials, fines migration and wettability alteration of Illite and Illite-Smectite clays upon exposure to model brines and a produced water, and a model oil and a crude oil. We measured density, viscosity, pH, TDS, and interfacial tension as they are important in multiphase flow and displacement characteristics. Geomaterial microfluidics is recently being used to study physicochemical interactions of solid-fluid systems. It facilitates visualizing the surface behavior upon exposure to various fluids. This study includes preparation and characterization of Illite-Smectite clay-coated glass capillary tubes. Illite and Illite-Smectite clay-coated geomaterial microfluidic surfaces were prepared to investigate the effects of first contact fluid, brine salinity, and aging on wettability. In this work, advancing and receding contact angles of model brine-air, model oil-air, produced water-air, crude oil-air, model brine-model oil systems, and produced water-crude oil systems have been measured in the untreated, and clay-coated microfluidic channels of 1000 µm width and 50 µm depth. The aging effect was studied by retaining the non-aqueous and aqueous solutions in the corresponding microfluidic channels for approximately 24 h in the case of channels first contacted by aqueous and non-aqueous solutions, respectively. The advancing and receding contact angles of Caney shale-crude oil-produced water systems were also measured. The experimental findings indicate the swelling potential, fines migration, and wettability alteration of Illite and Illite-Smectite clays. The results signify the influence of first contact fluid, brine salinity, and aging on wettability of the untreated and clay-coated microfluidic surfaces. The experiments also demonstrate the wetting nature of the Caney shale samples from reservoir and non-reservoir zones.

02 PETROLEUM↗

A versatile and low-cost chip-to-world interface: enabling ICP-MS characterization of isotachophoretically separated lanthanides on a microfluidic device

Microfluidics offer novel and state-of-the-art pathways to process materials. Microfluidic systems drastically reduce timeframes and costs associated with traditional lab-scale efforts in the area of analytical sample preparations. The challenge arises in effectively connecting microfluidics to off-chip analysis tools to accurately characterize samples after treatment on-chip. Here, a fused silica microfluidic device (MFD) is connected to a fused-silica capillary in order to create a world-to-chip connection between the MFD and an inductively coupled plasma mass spectrometer (ICP-MS). Specifically, this is demonstrated by utilizing isotachophoresis (ITP) on a microfluidic chip to separate samples containing up to 14 lanthanides into elementally pure bands. The separated sample is successfully transferred across a 7 nL dead space at the microchip-capillary junction, such that separation resolution is maintained and even increased through the interface and into the ICP-MS, where the elemental composition of the separated sample is analysed. Lanthanide samples of varying composition are detected using ICP-MS, demonstrating this versatile and cost-effective approach that does not degrade the separation quality achieved on the MFD. This simple and inexpensive connection enables fast, low-cost sample preparation immediately prior to injection into an ICP-MS or other analytical instruments.

Lackey, Hope E.↗

Enhanced Laser-Induced Graphene Microfluidic Integrated Sensors (LIGMIS) for On-Site Biomedical and Environmental Monitoring

The convergence of microfluidic and electrochemical biosensor technologies offers significant potential for rapid, in-field diagnostics in biomedical and environmental applications. Traditional systems face challenges in cost, scalability, and operational complexity, especially in remote settings. Addressing these issues, laser-induced graphene microfluidic integrated sensors (LIGMIS) are presented as an innovative platform that integrates microfluidics and electrochemical sensors both comprised of laser-induced graphene. This study advances the LIGMIS concept by resolving issues of uneven fluid transport, increased hydrophobicity during storage, and sensor biofunctionalization challenges. Key innovations include Y-shaped reservoirs for consistent fluid flow, hydrophilic polyethyleneimine coatings to maintain wettability, and separable microfluidic and electrochemical components enabling isolated electrode nanoparticle metallization and biofunctionalization. Multiplexed electrochemical detection of the neonicotinoid imidacloprid and nitrate ions in environmental water samples yields detection limits of 707 nm and 10 -5.4 m with wide sensing ranges of 5–100 µm and 10 -5 –10 -1 m, respectively. Similarly, uric acid and calcium ions are detected in saliva, demonstrating detection limits of 217 nm and 10 -5.3 m with sensing ranges of 10–50 µm, and 10 -5 –10 -2.5 m, respectively. Overall, this biosensing demonstrates the capability of the LIGMIS platform for multiplexed detection in biologically complex solutions, with applications in environmental water quality monitoring and oral cancer screening.

environmental monitoring↗

Multiphasic droplet microfluidics platform for controlled bacteria and mammalian cell co-culture

Microfluidics has revolutionized high-throughput miniaturized biological assays. However, co-culture of mammalian cells and bacteria remains challenging in microfluidic systems due to incompatible growth requirements, limited spatial control, and the requirement for a mammalian cell adhesion matrix. Here, we present a microfluidic platform that generates multiphasic droplets which encapsulate mammalian and bacterial cells, enabling their direct and indirect co-culture. By combining photopolymerizable hydrogels with polymer phase separation, we generate core–shell droplets composed of a liquid and a hydrogel compartment. The hydrogel compartment supports mammalian cell adhesion and culture, while the liquid compartment sustains bacterial growth. We demonstrate two droplet architectures that allow physical bacteria–mammalian cell contacts or enforce complete physical separation, representing direct and indirect co-culture. Our multiphasic droplets are stable, customizable, able to sustain co-culture for over 24 hours, and compatible with fluorescence-based cell sorting technologies. Overall, our multiphasic droplet microfluidic platform provides a scalable and versatile tool for high-throughput co-culture and screening of host–microbe interactions.

59 BASIC BIOLOGICAL SCIENCES↗

Data collection from crystals grown in microfluidic droplets

Protein crystals grown in microfluidic droplets have been shown to be an effective and robust platform for storage, transport and serial crystallography data collection with a minimal impact on diffraction quality. Single macromolecular microcrystals grown in nanolitre-sized droplets allow the very efficient use of protein samples and can produce large quantities of high-quality samples for data collection. However, there are challenges not only in growing crystals in microfluidic droplets, but also in delivering the droplets into X-ray beams, including the physical arrangement, beamline and timing constraints and ease of use. Here, the crystallization of two human gut microbial hydrolases in microfluidic droplets is described: a sample-transport and data-collection approach that is inexpensive, is convenient, requires small amounts of protein and is forgiving. It is shown that crystals can be grown in 50–500 pl droplets when the crystallization conditions are compatible with the droplet environment. Local and remote data-collection methods are described and it is shown that crystals grown in microfluidics droplets and housed as an emulsion in an Eppendorf tube can be shipped from the US to the UK using a FedEx envelope, and data can be collected successfully. Details of how crystals were delivered to the X-ray beam by depositing an emulsion of droplets onto a silicon fixed-target serial device are provided. After three months of storage at 4°C, the crystals endured and diffracted well, showing only a slight decrease in diffracting power, demonstrating a suitable way to grow crystals, and to store and collect the droplets with crystals for data collection. This sample-delivery and data-collection strategy allows crystal droplets to be shipped and set aside until beamtime is available.

59 BASIC BIOLOGICAL SCIENCES↗

Advancing radioactive material research method: the development of a novel in situ particle-attached microfluidic electrochemical cell

This study aims to develop a microgram-scale microfluidic electrochemical cell (E-cell) for investigating the redox behavior of uranium oxide (UO 2 ). The traditional bulk electrochemical methods may require shielded facilities to investigate the hazardous materials, e.g., spent nuclear fuel, due to high radiation levels. Microfluidic E-cells offer advantages such as reduced radiation exposure, control over fluid flow rates, and high-throughput capabilities. Methods: The design of the E-cell considers electrode morphology, adhesion to a thin membrane, electrode configuration, and vacuum compatibility. Three techniques, including FIB-SEM lift-out, Au coating, and polyvinylidene fluoride (PVDF) binder, are explored for fabricating and attaching microgram quantities of UO 2 as working electrodes. The PVDF binder method proves to be the most effective, enabling the creation of a vacuum-compatible microfluidic E-cell. Results and discussion: The PVDF binder method demonstrates successful electrochemical responses and allows for real-time monitoring of UO 2 electrode behavior at the microscale. It offers chemical imaging capabilities using in situ SEM/EDS analysis. The technique provides consistent redox outcomes similar to bulk electrochemical analysis. Conclusion: The development of a microgram-scale microfluidic electrochemical cell using the PVDF binder technique enables the investigation of UO 2 redox behavior. It offers a low-risk approach with reduced radiation exposure and high-throughput capabilities. The technique provides real-time monitoring and chemical imaging capabilities, making it valuable for studying spent nuclear fuel systems and material characterization.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Less Is More: Oligomer Extraction and Hydrothermal Annealing Increase PDMS Adhesion Forces for Materials Studies and for Biology-Focused Microfluidic Applications

Cues in the micro-environment are key determinants in the emergence of complex cellular morphologies and functions. Primary among these is the presence of neighboring cells that form networks. For high-resolution analysis, it is crucial to develop micro-environments that permit exquisite control of network formation. This is especially true in cell science, tissue engineering, and clinical biology. We introduce a new approach for assembling polydimethylsiloxane (PDMS)-based microfluidic environments that enhances cell network formation and analyses. We report that the combined processes of PDMS solvent-extraction and hydrothermal annealing create unique conditions that produce high-strength bonds between solvent-extracted PDMS (E-PDMS) and glass—properties not associated with conventional PDMS. Extraction followed by hydrothermal annealing removes unbound oligomers, promotes polymer cross-linking, facilitates covalent bond formation with glass, and retains the highest biocompatibility. Herein, our extraction protocol accelerates oligomer removal from 5 to 2 days. Resulting microfluidic platforms are uniquely suited for cell-network studies owing to high adhesion forces, effectively corralling cellular extensions and eliminating harmful oligomers. We demonstrate the simple, simultaneous actuation of multiple microfluidic domains for invoking ATP- and glutamate-induced Ca 2+ signaling in glial-cell networks. These E-PDMS modifications and flow manipulations further enable microfluidic technologies for cell-signaling and network studies as well as novel applications.

36 MATERIALS SCIENCE↗