Search NASA⌕ Search

SEARCH · Search NASA

Results for “Microplasma”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Construction of a Compact Array of Microplasma Jet Devices and Its Application for Random Mutagenesis of Rhodosporidium toruloides

A small and efficient DNA mutation-inducing machine was constructed with an array of microplasma jet devices (7 × 1) that can be operated at atmospheric pressure for microbial mutagenesis. Using this machine, we report disruption of a plasmid DNA and generation of mutants of an oleaginous yeast Rhodosporidium toruloides. Specifically, a compact-sized microplasma channel (25 × 20 × 2 mm 3 ) capable of generating an electron density of greater than 10 13 cm –3 was constructed to produce reactive species (N 2 *, N 2 +, O, OH, and H α ) under helium atmospheric conditions to induce DNA mutagenesis. The length of microplasma channels in the device played a critical role in augmenting both the volume of plasma and the concentration of reactive species. First, we confirmed that microplasma treatment can linearize a plasmid by creating nicks in vitro. Second, we treated R. toruloides cells with a jet device containing 7 microchannels for 5 min; 94.8% of the treated cells were killed, and 0.44% of surviving cells showed different colony colors as compared to their parental colony. Microplasma-based DNA mutation is energy-efficient and can be a safe alternative for inducing mutations compared to conventional methods using toxic mutagens. In conclusion, this compact and scalable device is amenable for industrial strain improvement involving large-scale mutagenesis.

59 BASIC BIOLOGICAL SCIENCES↗

Data for Construction of a Compact Array of Microplasma Jet Devices and Its Application for Random Mutagenesis of Rhodosporidium toruloides

A small and efficient DNA mutation-inducing machine was constructed with an array of microplasma jet devices (7 × 1) that can be operated at atmospheric pressure for microbial mutagenesis. Using this machine, we report disruption of a plasmid DNA and generation of mutants of an oleaginous yeast Rhodosporidium toruloides . Specifically, a compact-sized microplasma channel (25 × 20 × 2 mm3) capable of generating an electron density of greater than 1013 cm–3 was constructed to produce reactive species (N2*, N2+, O, OH, and Hα) under helium atmospheric conditions to induce DNA mutagenesis. The length of microplasma channels in the device played a critical role in augmenting both the volume of plasma and the concentration of reactive species. First, we confirmed that microplasma treatment can linearize a plasmid by creating nicks in vitro. Second, we treated R. toruloides cells with a jet device containing 7 microchannels for 5 min; 94.8% of the treated cells were killed, and 0.44% of surviving cells showed different colony colors as compared to their parental colony. Microplasma-based DNA mutation is energy-efficient and can be a safe alternative for inducing mutations compared to conventional methods using toxic mutagens. This compact and scalable device is amenable for industrial strain improvement involving large-scale mutagenesis.

Conversion↗

CH 3 Radical Generation in Microplasmas for Up-Conversion of Methane

The conversion of methane, CH 4 , into higher value chemicals using low temperature plasmas is challenged by both improving efficiency and selectivity. One path towards selectivity is capturing plasma produced methyl radicals, CH 3 , in a solvent for aqueous processing. Due to the rapid reactions of methyl radicals in the gas phase, the transport distance from production of the CH 3 to its solvation should be short, which then motivates the use of microplasmas. The generation of CH 3 in Ar/CH 4 /H 2 O plasmas produced in nanosecond pulsed dielectric barrier discharge microplasmas is discussed using results from a computational investigation. The microplasma is sustained in the channel of a microfluidic chip in which the solvent flows along one wall or in droplets. CH 3 is primarily produced by electron-impact of and dissociative excitation transfer to CH 4 , as well as CH 2 reacting with CH 4 . CH 3 is rapidly consumed to form C 2 H 6 which, in spite of being subject to these same dissociative processes, accumulates over time, as do other stable products including C 3 H 8 and CH 3 OH. The gas mixture and electrical properties were varied to assess their effects on CH 3 production. CH 3 production is largest with 5% CH 4 in the Ar/CH 4 /H 2 O mixture due to an optimal balance of electron-impact dissociation, which increases with CH 4 percentage, and dissociative excitation transfer and CH 2 reacting with CH 4 , which decrease with CH 4 percentage. Design parameters of the microchannels were also investigated. Increasing the permittivity of the dielectrics in contact with the plasma increased the ionization wave intensity which increased CH 3 production. Increased energy deposition per pulse generally increased CH 3 production as does lengthening pulse length up to a certain point. The arrangement of the solvent flow in the microchannel can also affect the CH 3 density and fluence to the solvent. The fluence of CH 3 to the liquid solvent is increased if the liquid is immersed in the plasma as a droplet or is a layer on the wall where the ionization wave terminates. The solvation dynamics of CH 3 with varying numbers of droplets was also examined. Here, the maximum density of solvated methyl radicals CH 3aq occurs with a large number of droplets in the plasma. However, the solvated CH 3aq density can rapidly decrease due to desolvation, emphasizing the need to quickly react the solvated species in the solvent.

03 NATURAL GAS↗

One-step atmospheric microplasma synthesis of an NMC-type lithium-ion battery cathode

The manufacture of battery cathode materials is the most energy-intensive step in the production of commercial lithium-ion batteries; specifically, the synthesis of the widely used transition metal oxide cathodes can require tens of hours at temperatures exceeding 700 °C. Attempts to limit the reaction time and energy required to form crystalline cathode materials often still include a heating or calcination step. This communication aims to highlight a nascent yet novel synthesis route: a one-step atmospheric microplasma process for synthesizing cathode particles in less than one second. The hollow-tube reactor employed produces crystalline particles measuring 0.1–3 μm in diameter, displays narrow XRD peaks corresponding to the 003, 104, and 101 planes, and exhibits anodic redox behavior at 3.75 V vs. lithium—characteristic of transition-metal oxide cathode materials—all without requiring an additional calcination step.

25 ENERGY STORAGE↗

Single-Particle Isotopic Analysis Using the Liquid Sampling-Atmospheric Pressure Glow Discharge Microplasma Coupled to an Orbitrap Mass Spectrometer

Isotope ratio (IR) determinations on individual particles can provide valuable information relative to the sample, including processing and dating, which could be valuable to geological and nuclear material analysis communities. In comparison to “bulk” measurements, in which all particle information is lost and homogenized within a sample, “particle” measurements allow for fingerprinting and can provide unique insights related to the sample’s nano- and micro- compositions. Furthermore, the complex nature of particles, with potential isobaric interferences from either the matrix or other elements within the same particle, poses a significant analytical challenge for conventional mass spectrometry platforms employed for elemental analysis due to their limited mass resolution. Presented here is the first demonstration of an ultrahigh resolution method for single particle (SP) isotopic analysis using the liquid sampling-atmospheric pressure glow discharge (LS-APGD) microplasma ionization source coupled to an Orbitrap mass spectrometer and FTMS Booster X2T acquisition/processing system. For proof of concept, well-characterized CeO 2 microparticles with a nominal diameter of 1.0 μm were analyzed at a mass resolution of ∼330,000. Important instrumental parameters were optimized to enable the detection of single particles. The 142 Ce/ 140 Ce ratio of individual particles and the population average were determined and compared to an SP inductively coupled plasma time-of-flight mass spectrometry (ICP-TOF-MS) analysis. The isotopic accuracy and precision were determined by two methods and found to be in good agreement with the SP-ICP-TOF-MS method, with the linear regression slope method providing a more accurate ratio, showing a ∼1.4% relative difference from the ratio determined from a particle digest. The encouraging performance of the method was further supported by a determined detection limit of 2.9 fg ( 142 Ce). The developed method is anticipated to overcome many of the challenges posed by isobaric interferences encountered in conventional mass spectrometry techniques when analyzing real-world samples for particle isotopic composition.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Argon metastable density and temperature of a 94 GHz microplasma

Laser diode absorption spectroscopy is used to experimentally measure Ar(1s 5 ) metastable density and translational gas temperature within a 94 GHz microplasma. A square two-dimensional photonic crystal (PhC) at this resonance frequency serves to ignite and sustain the plasma from 20 to 200 Torr (2.7 × 10 3 –2.7 × 10 4 Pa) by using millimeter wave power from 300 to 1000 mW. Metastable density within the plasma is estimated from the absorption line shape of the laser traversing the PhC. The metastable density reaches an order of 10 19 m –3 at lower pressure and decreases as pressure increases. From the Lorentzian line shape of the absorption profile at 811.53 nm, the gas temperature is extracted and found to increase from 500 K at 20 Torr to 1300 K at 200 Torr. Furthermore, these data are analyzed and compared with a zero-dimensional plasma model and with previous experimental plasma results at 43 GHz.

42 ENGINEERING↗

Could Microplasma Ionization and Ultrahigh Mass Resolution Alleviate Chemical Separations for Elemental and Isotopic Analysis?

At the extremes, all analytical spectrometric measurements are limited by the resolution of the spectrometer system. Spectral overlaps, isobars in the case of mass spectrometry, can lead to the implementation of complex and time-consuming chemical separations to alleviate those interferences. In the area of elemental/isotopic mass spectrometry, use of sector-field instruments can provide a mass resolution of ~10,000, but still necessitate chemical separations. Described here is the coupling of the liquid sampling-atmospheric pressure glow discharge (LS-APGD) microplasma to ultra-high resolution Orbitrap mass analyzer systems to yield mass resolution values ranging from 70k to 1M. Resolution of this order, with commensurate improvements in precision and accuracy, holds the promise to affect elemental/isotopic determinations without the need for chemical separations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Hollow cathode startup using a microplasma discharge

Attention is given to a microplasma discharge to initiate a hollow cathode discharge for such applications as plasma flow experiments, the electric propulsion of space vehicles, and as a replacement for filament cathodes in neutral beam injector ion sources. The technique results in a cathode that is easy to start, simple in design, and which does not require external RF exciters, inserts or heating elements. Future applications may include ion beam milling and ion implantation.

Aston, G.↗

Analysis of an irradiated uranium sample for source attribution without chemical separation using microplasma ionization and ultrahigh resolution mass spectrometry

The use of element isotope ratios has great potential in not only determining the reactor type used to produce plutonium (Pu) but also in determining the burnup and the time since irradiation. While a powerful nuclear forensic technique, determining element isotope ratios is complicated by severe isobaric interferences when performed on typical inductively coupled plasma mass spectrometers. Such analyses require extensive chemical separations prior to analysis to alleviate the inter-elemental isobars. Ultrahigh mass resolution spectrometry provides a potential alternative, greatly reducing the complexity of sample preparation and turnaround times for these critical measurements. To demonstrate the power of the approach, a sample of irradiated, depleted uranium was analyzed with the liquid sampling—atmospheric pressure glow discharge ion source coupled to an Orbitrap mass spectrometer. The Orbitrap is augmented with an external data acquisition system, Spectroswiss’s FTMS-Booster X2T, allowing collection of extended ion transients, providing higher mass resolution. In using this approach, the 150 Sm/ 149 Sm and 152 Sm/ 149 Sm isotope ratios were found to be within 20% of predicted values without any chemical separations and without mass bias corrections. In addition, the 240 Pu/ 239 Pu isotope ratio was determined, free from the 238 UH + interferences common to the ICP-MS platforms, while at the same time allowing for the determination of U isotopic signatures. While these demonstrative results are from a single sample, the advantages of the microplasma/ultrahigh mass resolution approach to intra-element isotope ratio determinations are clear.

Fuel burnup↗

Generating and Sustaining Microplasma with Microwaves (Final Report)

Plasma can be generated in spaces ranging in size from astronomical down to the microscopic. The physics that describes the gas breakdown is different at each size scale. The dominant physical phenomenon also depends on the type of electromagnetic field that drives the breakdown – static, AC, RF, microwave, visible. This project, staffed by undergraduate researchers and their mentor, focused on plasma generated in the size range of 10 to 500 micrometers using microwave energy. This project was motivated by the prior observation that plasma can only be generated in microgaps when the gas is above a certain gap-dependent pressure, here called the transition pressure. A microwave-driven microgap was designed and constructed in this project and then used to measure the electric field required to initiate plasma over a wide range of pressures from 0.1 Torr to 760 Torr (1 atmosphere).

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Exploring the THz Frontier of Experimental Microplasma (Final Report)

This is the final report for a three-year program to explore photonic crystals as a scalable medium for creating extremely high frequency plasma. The plasmas are then experimentally characterized and modeled. The conclusion of this work is that the photonic crystal is an attractive mode for creating plasma devices that extend into the THz band.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Utilization of the LS-APGD microplasma/orbitrap-FTMS booster system for detection and isotopic analysis of neodymium nanoparticles

Detection and isotopic analysis of particle populations has seen rapid growth across several application areas, including environmental analysis, nuclear forensics, and food safety. The ability to characterize the particles' unique elemental and isotopic fingerprints could provide information related to formation, processing history, and transport. Regarding nuclear forensics, isotopic analysis of particles derived from diverse materials is often used as a tool to trace the origin and processing history. Mass spectrometric-based techniques currently used for particle population analysis often suffer from limited mass resolution, particularly when dealing with real-world samples that are affected by isobaric and polyatomic interferences from the matrix. To address these analytical challenges, we propose a novel method utilizing the liquid sampling-atmospheric pressure glow discharge (LS-APGD) microplasma ionization source coupled to an ultrahigh resolution Orbitrap mass spectrometer, further enhanced with the FTMS X2T Booster data acquisition and processing unit. The FTMS Booster enables acquisition of extended transient times of up to 3 s, significantly improving mass resolution, thereby reducing or even eliminating the need for prior separation of isobaric or polyatomic interferences. Additionally, the detection of low-abundance isotopes was improved by increasing the signal-to-noise (S/N) ratio. As proof of concept, this study demonstrates the feasibility of the LS-APGD/Orbitrap-FTMS X2T Booster platform for direct analysis using a suspension of well-characterized ∼120 nm neodymium particles. The quality of the isotope ratios values obtained from a few hundred particles were in good agreement with those obtained from homogeneous ionic solutions. These results highlight the potential of the LS-APGD/Orbitrap platform for rapid, accurate, and interference-resilient isotope ratio analysis of particle populations without the need for dissolution and subsequent chemical separations, offering significant advantages for nuclear forensics, safeguards, and environmental applications. The effort here also points to further paths forward, hopefully towards single particle (SP) analysis using microplasma ionization and the ultrahigh resolving power of the Orbitrap mass analyzer.

FTMS X2T booster↗

Laser Ablation Plasmas and Spectroscopy for Nuclear Applications

The development of measurement methodologies to detect and monitor nuclear-relevant materials remains a consistent and significant interest across the nuclear energy, nonproliferation, safeguards, and forensics communities. Optical spectroscopy of laser-produced plasmas is becoming an increasingly popular diagnostic technique to measure radiological and nuclear materials in the field without sample preparation, where current capabilities encompass the standoff, isotopically resolved and phase-identifiable (e.g., UO and UO[Formula: see text]) detection of elements across the periodic table. These methods rely on the process of laser ablation (LA), where a high-powered pulsed laser is used to excite a sample (solid, liquid, or gas) into a luminous microplasma that rapidly undergoes de-excitation through the emission of electromagnetic radiation, which serves as a spectroscopic fingerprint for that sample. This review focuses on LA plasmas and spectroscopy for nuclear applications, covering topics from the wide-area environmental sampling and atmospheric sensing of radionuclides to recent implementations of multivariate machine learning methods that work to enable the real-time analysis of spectrochemical measurements with an emphasis on fundamental research and development activities over the past two decades. Background on the physical breakdown mechanisms and interactions of matter with nanosecond and ultrafast laser pulses that lead to the generation of laser-produced microplasmas is provided, followed by a description of the transient spatiotemporal plasma conditions that control the behavior of spectroscopic signatures recorded by analytical methods in atomic and molecular spectroscopy. High-temperature chemical and thermodynamic processes governing reactive LA plasmas are also examined alongside investigations into the condensation pathways of the plasma, which are believed to serve as chemical surrogates for fallout particles formed in nuclear fireballs. Laser-supported absorption waves and laser-induced shockwaves that accompany LA plasmas are also discussed, which could provide insights into atmospheric ionization phenomena from strong shocks following nuclear detonations. Furthermore, the standoff detection of trace radioactive aerosols and fission gases is reviewed in the context of monitoring atmospheric radiation plumes and off-gas streams of molten salt reactors. Finally, concluding remarks will present future outlooks on the role of LA plasma spectroscopy in the nuclear community.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Breakdown Degradation Associated with Elementary Screw Dislocations in 4H-SiC P(+)N Junction Rectifiers

It is well-known that SiC wafer quality deficiencies are delaying the realization of outstandingly superior 4H-SiC power electronics. While efforts to date have centered on eradicating micropipes (i.e., hollow core super-screw dislocations with Burgers vector greater than 2c), 4H-SiC wafers and epilayers also contain elementary screw dislocations (i.e., Burgers vector = lc with no hollow core) in densities on the order of thousands per sq cm, nearly 100-fold micropipe densities. This paper describes an initial study into the impact of elementary screw dislocations on the reverse-bias current-voltage (I-V) characteristics of 4H-SiC p(+)n diodes. First, Synchrotron White Beam X-ray Topography (SWBXT) was employed to map the exact locations of elementary screw dislocations within small-area 4H-SiC p(+)n mesa diodes. Then the high-field reverse leakage and breakdown properties of these diodes were subsequently characterized on a probing station outfitted with a dark box and video camera. Most devices without screw dislocations exhibited excellent characteristics, with no detectable leakage current prior to breakdown, a sharp breakdown I-V knee, and no visible concentration of breakdown current. In contrast devices that contained at least one elementary screw dislocation exhibited a 5% to 35% reduction in breakdown voltage, a softer breakdown I-V knee, and visible microplasmas in which highly localized breakdown current was concentrated. The locations of observed breakdown microplasmas corresponded exactly to the locations of elementary screw dislocations identified by SWBXT mapping. While not as detrimental to SiC device performance as micropipes, the undesirable breakdown characteristics of elementary screw dislocations could nevertheless adversely affect the performance and reliability of 4H-SiC power devices.

Neudeck, P. G.↗

Round Robin Analysis of Uranium Isotopics on Cotton Swipes Measured Using Microextraction-Based Sampling Versus Conventional Bulk Analysis

A comparison of microextraction sampling methods to directly analyze uranium isotopics on cotton swipes was performed concurrently with traditional bulk-processing methods. For the microextraction sampling approach, two different detection platforms were evaluated, a quadrupole-based inductively coupled plasma mass spectrometer (ICP-MS) and the liquid sampling-atmospheric pressure glow discharge (LS-APGD) coupled to an Orbitrap mass spectrometer. Results presented from this innovative sampling approach (i.e., microextraction) are compared with a more traditional approach employed for analysis of cotton-based environmental swipes, namely bulk ashing/digestion, separation, and subsequent analysis by high-precision multi-collector ICP-MS. Overall, the microextraction approach proved to be a reliable and accurate means to determine isotopic ratios of uranium collected on cotton swipes. The ICP-MS-based detection had relative standard deviations of <0.65% for the major isotopic determinations, whereas the LS-APGD-Orbitrap method had relative standard deviations of <3%. The percent relative difference for the 235 U/ 238 U ratios, in comparison to the expected values, was <1% for ICP-MS and <4% for the microplasma-Orbitrap method. Additionally, the microextraction ICP-MS accurately (<2%) and precisely (<5%) determined the minor isotopic compositions (i.e., 234 U/ 238 U and 236 U/ 238 U).

ICP-MS↗