Search NASA⌕ Search

SEARCH · Search NASA

Results for “Microscopy Module”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Probing the Mechanical Properties of 2D Materials via Atomic‐Force‐Microscopy‐Based Modulated Nanoindentation

Abstract As the field of low‐dimensional materials (1D or 2D) grows and more complex and intriguing structures are continuing to be found, there is an emerging need for techniques to characterize the nanoscale mechanical properties of all kinds of 1D/2D materials, in particular in their most practical state: sitting on an underlying substrate. While traditional nanoindentation techniques cannot accurately determine the transverse Young's modulus at the necessary scale without large indentations depths and effects to and from the substrate, herein an atomic‐force‐microscopy‐based modulated nanomechanical measurement technique with Angstrom‐level resolution (MoNI/ÅI) is presented. This technique enables non‐destructive measurements of the out‐of‐plane elasticity of ultra‐thin materials with resolution sufficient to eliminate any contributions from the substrate. This method is used to elucidate the multi‐layer stiffness dependence of graphene deposited via chemical vapor deposition and discover a peak transverse modulus in two‐layer graphene. While MoNI/ÅI has been used toward great findings in the recent past, here all aspects of the implementation of the technique as well as the unique challenges in performing measurements at such small resolutions are encompassed.

2D materials↗

Impacts of irradiation-induced nanostructure on phonon linewidths and thermal conductivity in U-Zr alloy

Ion irradiation can significantly change material properties. Thermal conductivity degradation of reactor fuel is detrimental to safety and efficiency—driving research on how irradiation impacts heat-carrying phonons. Here, we report the measurements of phonon dispersion and lifetimes (inverse linewidths) in freestanding irradiated crystals and reveal the relationship between thermal conductivity and proton irradiation induced nanostructures in UZr 2.6 using inelastic x-ray scattering, electron microscopy, modulated thermoreflectance, and first-principles calculations. Irradiation results in more significant increases in phonon linewidths and decreased thermal conductivity in the basal plane than that along the c axis, decreasing thermal conductivity anisotropy. Furthermore, microscopy reveals that this results from irradiation induced nanoprecipitates and metastable phase separation. Surprisingly, irradiation leads to smaller phonon linewidths near some zone boundaries, which we attribute to irradiation induced short-range order.

36 MATERIALS SCIENCE↗

Multicolor multifocal 3D microscopy using in-situ optimization of a spatial light modulator

Abstract Multifocal microscopy enables high-speed three-dimensional (3D) volume imaging by using a multifocal grating in the emission path. This grating is typically designed to afford a uniform illumination of multifocal subimages for a single emission wavelength. Using the same grating for multicolor imaging results in non-uniform subimage intensities in emission wavelengths for which the grating is not designed. This has restricted multifocal microscopy applications for samples having multicolored fluorophores. In this paper, we present a multicolor multifocal microscope implementation which uses a Spatial Light Modulator (SLM) as a single multifocal grating to realize near-uniform multifocal subimage intensities across multiple wavelength emission bands. Using real-time control of an in-situ-optimized SLM implemented as a multifocal grating, we demonstrate multicolor multifocal 3D imaging over three emission bands by imaging multicolored particles as well as Escherichia coli ( E. coli ) interacting with human liver cancer cells, at $$\sim 2.5$$ ∼ 2.5 multicolor 3D volumes per second acquisition speed. Our multicolor multifocal method is adaptable across SLM hardware, emission wavelength band locations and number of emission bands, making it particularly suited for researchers investigating fast processes occurring across a volume where multiple species are involved.

47 OTHER INSTRUMENTATION↗

Electrochemically modulated single-molecule localization microscopy for in vitro imaging cytoskeletal protein structures

A new concept of electrochemically modulated single-molecule localization super-resolution imaging is developed. Applications of single-molecule localization super-resolution microscopy have been limited due to insufficient availability of qualified fluorophores with favorable low duty cycles. The key for the new concept is that the “On” state of a redox-active fluorophore with unfavorable high duty cycle could be driven to “Off” state by electrochemical potential modulation and thus become available for single-molecule localization imaging. The new concept was carried out using redox-active cresyl violet with unfavorable high duty cycle as a model fluorophore by synchronizing electrochemical potential scanning with a single-molecule localization microscope. The two cytoskeletal protein structures, the microtubules from porcine brain and the actins from rabbit muscle, were selected as the model target structures for the conceptual imaging in vitro. The super-resolution images of microtubules and actins were obtained from precise single-molecule localizations determined by modulating the On/Off states of single fluorophore molecules on the cytoskeletal proteins via electrochemical potential scanning. Importantly, this method could allow more fluorophores even with unfavorable photophysical properties to become available for a wider and more extensive application of single-molecule localization microscopy.

electrochemical modulation↗

Photovoltaic module antireflection coating degradation survey using color microscopy and spectral reflectance

Abstract Commercial antireflective coatings (ARCs) on photovoltaic (PV) module glass can improve module power by 2.5%–3.0%, but their long‐term field performance requires additional study. In this paper, we investigate ARC performance on fielded modules using two nondestructive techniques: reflectance spectroscopy and RGB microscopy, finding a large variation in coating durability and performance. For new coatings, the fleet average nominal power enhancement is 2.8%. This power enhancement is observed to degrade at approximately −0.05%/year absolute over the first 8 years of fielding in arrays that are not regularly cleaned. Interferometry and imaging results imply that coating loss for these modules is due to slow chemical thinning of the initial 125 nm thick coating by 1.4 to 5.0 nm/year. Due to the physics of interference coatings, the performance loss is projected to accelerate as the coating is further thinned, resulting in a coating lifetime (time to 80% of initial performance) of 7.5 to 25 years. At the higher 5.0 nm/year coating loss rates, we estimate that −0.14%/year power degradation of the module can be attributed solely to ARC degradation over the first 20 years. Extreme coating loss is observed on some modules where after 8 years fielding, the coating can be completely removed with a single wet wipe with a lens tissue. A case study is also presented comparing ARC and noncoated modules installed at a single site in 2013. We find that the ARC modules have a 2.6% higher soiling power loss than the noncoated modules; this exceeds the ARC power enhancement of 2.4% and leads to the surprising conclusion that the ARC lowers production for modules in this location due to increased soiling. These results demonstrate that RGB microscopy is a powerful, field‐capable, and quantitative characterization technique for assessing degradation of PV module ARCs.

Karin, Todd↗

Transmission Electron Microscopy Study on Microstructure of Degraded CdTe Mini-Modules

In this paper, we employ transmission electron microscopy coupled with energy-dispersive X-ray spectrometry (EDS) to study the structure and chemistry of cadmium telluride (CdTe) thin-film solar cells with different extents of degradation. The studied regions originate from the same photovoltaic mini-module, which was subjected to one-sun light exposure at a temperature of 100 degrees C for 400 h to induce light and heat degradation. EDS maps reveal a discontinuous CdS layer and particles rich in O and S but Te-depleted within the CdTe absorber layer after the light and heat stress. These features could act as enhanced recombination centers, resulting in decreased photovoltaic conversion efficiency. Additionally, the most degraded CdTe sample shows a strong accumulation of Na precisely localized in the discontinuous part of the CdS layer. The local Na concentration is determined to be ~16 at.%. In addition, appreciable Na accumulation is observed at the soda-lime glass/transparent conductive oxide interface in both degraded CdTe solar cells. The microstructure of the baseline CdTe mini-module with no stress was also investigated to demonstrate that the structure difference was caused by the light- and heat-induced degradation, instead of module fabrication. These results highlight the need to control the distribution of Na in fielded CdTe modules to sustain long-term high-power output.

14 SOLAR ENERGY↗

Electrochemical Frequency Modulation, Electrochemical Noise, and Atomic Force Microscopy Studies on Corrosion Inhibition Behavior of Benzothiazolone for Steel API X100 in 10% HCl Solution

In this work, electrochemical and surface techniques were applied to study the corrosion inhibition effects of benzothiazolone. 10% HCl was used to simulate the oil and gas well-acidizing fluid. Electrochemical frequency modulation and potentiodynamic polarization indicated that this material has excellent inhibiting features in very low concentrations. The influence of DC trend on electrochemical noise data was evaluated by polynomial fitting, and the optimum polynomial order m = 4 was obtained. After detrending, the charge of corrosion reaction obtained by electrochemical noise decreased with increasing inhibitor concentrations. In addition, the inhibition efficiencies from electrochemical noise were in agreement with data obtained by other electrochemical methods. Surface studies illustrated that the corroded surface was smoother in the presence of benzothiazolone. Electrochemical impedance and noise showed that benzothiazolone blocked the electrode surface by adsorption obeying Langmuir isotherm. According to quantum calculation, S atom in benzothiazolone indicated more tendencies for electrophilic attack in adsorption process. The main reason for high inhibition efficiencies in very low concentrations was the planar and simplicity of inhibitor structure which led to increasing the efficiency of adsorption by functional group especially sulfur.

36 MATERIALS SCIENCE↗

Quantitative Electromechanical Atomic Force Microscopy

The ability to probe a materials electromechanical functionality on the nanoscale is significant to applications from energy storage and computing to biology and medicine. Voltage modulated atomic force microscopy (VM-AFM) has become a mainstay characterization tool for investigating these materials due to its ability to locally probe electromechanically responsive materials with spatial resolution from microns to nanometers. However, with the wide popularity of VM-AFM techniques such as piezoresponse force microscopy (PFM) and electrochemical strain microscopy (ESM) there has been a rise in reports of nanoscale electromechanical functionality, including hysteresis, in materials that should be incapable of exhibiting piezo- or ferroelectricity. Explanations for the origins of unexpected nanoscale phenomena have included new material properties, surface-mediated polarization changes and/or spatially resolved behavior that is not present in bulk measurements. At the same time, it is well known that VM-AFM measurements are vulnerable to numerous forms of crosstalk and, despite efforts within the AFM community, a global approach for eliminating this has remained elusive. Here, we develop a method for easily demonstrating the presence of hysteretic ( i.e. “false ferroelectric”) long-range interactions between the sample and cantilever body. This approach should be easy to implement in any VM-AFM measurement. We then go on to demonstrate fully quantitative and repeatable nanoelectromechanical characterization using an interferometer. These quantitative measurements are critical for a wide range of devices including mems actuators and sensors, memristor, energy storage and memory.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Quantitative measurement of pebble fuel anisotropy using generalized ellipsometry

The renewed development of high-temperature gas-cooled reactors has created a need to modernize pebble fuel quality control methods. One important specification in these methods is the coefficient of thermal expansion (CTE) anisotropy, which reflects graphite grain alignment and affects fuel performance. This study investigates the feasibility of using two-modulator generalized ellipsometry microscopy (2-MGEM) as a potential surrogate metric for CTE anisotropy. Graphite matrix compacts with controlled levels of anisotropy were fabricated by varying pre-pressures during forming and were subsequently characterized using both optical dilatometry and 2-MGEM. Measured responses were compared to an isotropic reference pebble produced using an industrial manufacturing process to provide a practical baseline. The resulting measurements revealed a strong quantitative correlation between the CTE anisotropy ratio and the corresponding diattenuation ratio. However, propagated measurement uncertainties in the optical method were found to limit definitive pass/fail discrimination, highlighting the need for improved precision before qualification as a quality control tool. Still, the results establish a quantitative relationship between optical and CTE anisotropy and support further development of 2-MGEM as a potential surrogate method for evaluating graphite matrix anisotropy in pebble fuel manufacturing.

Raftery, Alicia [ORNL] (ORCID:0000000259076427)↗

Ferroelectric or non-ferroelectric: Why so many materials exhibit “ferroelectricity” on the nanoscale

Here, ferroelectric materials have remained one of the major focal points of condensed matter physics and materials science for over 50 years. In the last 20 years, the development of voltage-modulated scanning probe microscopy techniques, exemplified by Piezoresponse force microscopy (PFM) and associated time- and voltage spectroscopies, opened a pathway to explore these materials on a single-digit nanometer level. Consequently, domain structures and walls and polarization dynamics can now be imaged in real space. More generally, PFM has allowed studying electromechanical coupling in a broad variety of materials ranging from ionics to biological systems.

36 MATERIALS SCIENCE↗

Ion movement in thin Nafion films under an applied electric field

In this study, the electromechanical response of Nafion films with and without an ionic liquid (1-ethyl-3-methylimidazolium bis(trifluoromethylsulfonyl)imide) ([emim]Tf 2 N) additive were characterized under an applied electric field in situ using neutron reflectometry (NR) and voltage modulated atomic force microscopy (VM-AFM). NR showed that pure Nafion films exhibited no response under field strengths of ~0.18 V/μm, while VM-AFM measurements showed a minimal response at higher field strengths (~200 V/μm), which is ascribed to the residual water presence in the films. The addition of ionic liquid resulted in clear electroresponsiveness seen in both NR and VM-AFM. NR results indicated mass migration away from the cathodic interface driven by the [emim] + movement in the direction of the electric field. The lack of ionic liquid accumulation at the electrode interfaces contrasts the bulk electromechanical behavior of similar systems reported in the literature. VM-AFM measurements were able to resolve the relative contributions of the [emim] + cation and Tf 2 N - anion to film deformation by alternating the direction of the applied field and support the [emim] + dominant migration seen in the NR results. Lastly, the findings presented here emphasize the need for the nanoscale analysis of material properties of electroresponsive thin film systems and demonstrate the potential for probing electric field effects using in situ techniques.

36 MATERIALS SCIENCE↗

Towards nanoscale electrical measurements in liquid by advanced KPFM techniques: a review

Fundamental mechanisms of energy storage, corrosion, sensing, and multiple biological functionalities are directly coupled to electrical processes and ionic dynamics at solid–liquid interfaces. In many cases, these processes are spatially inhomogeneous taking place at grain boundaries, step edges, point defects, ion channels, etc and possess complex time and voltage dependent dynamics. This necessitates time-resolved and real-space probing of these phenomena. In this review, we discuss the applications of force-sensitive voltage modulated scanning probe microscopy (SPM) for probing electrical phenomena at solid–liquid interfaces. We first describe the working principles behind electrostatic and Kelvin probe force microscopies (EFM & KPFM) at the gas–solid interface, review the state of the art in advanced KPFM methods and developments to (i) overcome limitations of classical KPFM, (ii) expand the information accessible from KPFM, and (iii) extend KPFM operation to liquid environments. We briefly discuss the theoretical framework of electrical double layer (EDL) forces and dynamics, the implications and breakdown of classical EDL models for highly charged interfaces or under high ion concentrations, and describe recent modifications of the classical EDL theory relevant for understanding nanoscale electrical measurements at the solid–liquid interface. We further review the latest achievements in mapping surface charge, dielectric constants, and electrodynamic and electrochemical processes in liquids. Lastly, we outline the key challenges and opportunities that exist in the field of nanoscale electrical measurements in liquid as well as providing a roadmap for the future development of liquid KPFM.

36 MATERIALS SCIENCE↗

Optical functions of uniaxial rutile and anatase (TiO 2 ) revisited

In this study, the optical functions of uniaxial rutile and anatase (TiO2) were determined from 200 to 850 nm (6.2 to 1.46 eV) using several of four optical techniques: (1) standard spectroscopic two-modulator generalized ellipsometry (2-MGE), (2) near-normal-incidence two-modulator generalized ellipsometry microscopy (2-MGEM), (3) Mueller matrix transmission of rutile, and (4) polarized transmission of rutile. The 2-MGE measurements yielded highly accurate values of the dielectric functions and error estimates from 1.46 to 6.2 eV, whereas the polarization-dependent transmission yielded more accurate values of the absorption coefficient below the band edge of rutile. The 2-MGEM also measured the diattenuation, which is related to the birefringence, and other parameters but at near-normal incidence at a single wavelength (577 nm).

36 MATERIALS SCIENCE↗

Optical functions of crystalline and amorphous TeO2

The optical functions of crystalline paratellurite (α-TeO2) and amorphous TeO2 were determined using several optical techniques: (1) standard spectroscopic two-modulator generalized ellipsometry (2-MGE) of paratellurite (200–850 nm, 6.2–1.46 eV), (2) near-normal-incidence two-modulator generalized ellipsometry microscopy (2-MGEM) of paratellurite (577 nm, 2.15 eV), (3) Mueller matrix transmission of paratellurite (320–798 nm, 3.87–1.55 eV), and (4) polarized transmission of paratellurite (323.6–334.3 nm, 3.83–3.71 eV). The 2-MGE measurements yielded highly accurate values of the dielectric functions and error estimates from 1.46 to 6.2 eV for both paratellurite and amorphous TeO2, whereas the polarization-dependent transmission yielded more accurate values of the absorption coefficient below the band edge of paratellurite. The 2-MGEM measured the diattenuation of paratellurite, which is related to the birefringence. Mueller matrix transmission measurements of paratellurite of a (001) cut crystal as a function of angle of incidence were used to determine both the birefringence and the rotary power as a function of photon energy.

Jellison Jr, Gerald [ORNL]↗