Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Frontier system-on-chip (SoC) technology for microwave diagnostics (invited)

The next generation of fusion reactors, exemplified by projects such as the Demonstration Power Plant following the International Thermonuclear Experimental Reactor, faces the monumental challenge of proving the viability of generating electricity through thermonuclear fusion. This pursuit introduces heightened complexities in diagnostic methodologies, particularly in microwave-based diagnostics. The increased neutron fluence necessitates significant reductions in vessel penetrations and the elimination of internal diagnostics, posing substantial challenges. SoC technology offers a promising solution by enabling the miniaturization, modularization, integration, and enhancing the reliability of microwave systems. After seven years of research, our team successfully pioneered the V- and W-band system-on-chip approach, leading to the development of active transmitters and passive receiver modules applied in practical settings, notably within the DIII-D tokamak project. Arrays of these modules have supported microwave imaging diagnostics. New physics measurement results from the Electron Cyclotron Emission Imaging system on DIII-D provide compelling evidence of improved diagnostics following the adoption of SoC technology. Furthermore, we achieved a breakthrough in developing an F-band SoC, advancing higher frequency capabilities for fusion devices. These achievements represent a significant leap forward in fusion diagnostic technology, marking substantial progress toward establishing reliable and efficient plasma diagnostics for future fusion reactors.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

System-on-Chip approach microwave diagnostics development for burning plasma

System-on-chip (SoC) millimeter wave integrated circuit technology has been developed and employed in chip heterodyne radiometers in Electron Cyclotron Emission Imaging (ECEI) and Microwave Imaging Reflectometer (MIR) on the DIII-D tokamak for 2D electron temperature and density fluctuation diagnostics. The W-band (75-110 GHz) ECEI system has been employed with 20 poloidal horn receiver modules with customized monolithic integrated circuit chips and internal local oscillator coupling path. The new SoC approach demonstrates > 30 dB additional gain on the receiver and 95% electronics noise suppression compared to the previous Schottky diode mixer array . An F-band (110-140 GHz) receiver chip has been developed to measure MHD and turbulence behavior on the DIII-D high-field side, such as Alfven eigenmodes. Furthermore, it can image pedestal structure evolution on fusion facilities with stronger magnetic fields, such as ASDEX-U, EAST, HL-2M, and LHD. The F-band chip performance has been tested in the laboratory. Also, V-band (55-75 GHz) transmitter and receiver modules (55-75 GHz) have been developed for DIII-D and NSTX-U Furthermore, microwave Imaging Reflectometer (MIR) application suitability for 2D density fluctuation imaging on the pedestal region.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Microwave diagnostic for the determination of the electron temperature of a low density shock-heated argon plasma

The diffraction, defocusing and beam bending effects of microwaves transmitted through a bounded shock-heated argon plasma with low electron density are investigated with the purpose of developing an accurate method for electron temperature (Te) determination. This report describes the evaluation technique and presents results for an argon plasma with pressure between 3 and 10 torr, and T2 between 5500 and 9500 K. The electron temperature values obtained have a range of uncertainty between -20% and +10% only. The electron temperature is equal or lower by approximately 1000 K in comparison to the heavy particle temperature (T2).

Schneider, C. P.↗

Plasma confinement state classification via FPP relevant microwave diagnostics

We present a parsimonious and robust machine learning approach for identifying plasma confinement states in fusion power plants (FPPs) where reliable identification of the low-confinement and high-confinement regimes is critical for safe and efficient operation. Unlike research-oriented devices, FPPs must operate with a severely constrained set of diagnostics. To address this challenge, we demonstrate that a minimalist model, using only electron cyclotron emission (ECE) signals, can achieve accurate and reliable state classification. ECE provides electron temperature profiles without the engineering or survivability issues of in-vessel probes, making it a primary candidate for FPP-relevant diagnostics. Our framework employs ECE as input, extracts features using radial basis functions, and applies a gradient boosting classifier, achieving a test accuracy of 96% (correct predictions). Robustness analysis and feature importance analyzes confirm the approach’s reliability. These results demonstrate that state-of-the-art performance is attainable from a restricted diagnostic set, paving the way for minimalist yet resilient plasma control architectures for FPPs.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Microwave diagnostics and passive sensors for pipeline, well-bore, and boiler-tube monitoring

Materials, methods of making, and methods of using an integrated wireless detector for real time interrogating metallic tubular structures comprising: an RF patch antenna; a passive surface acoustic wave (SAW) sensor; and data analytic methodologies. An embodiment relates to interrogating a metallic structure having a uniform cross section using an antenna which launches electromagnetic radiation. A sensor may be located within the structure is configured to re-emit electromagnetic radiation modified depending on parameters for which the sensor has been functionalized. An antenna may receive radiation as modified by the sensor, or may receive the transmitted or backscattered radiation directly, without use of a sensor. The antenna then communicates wirelessly with an interrogator providing data which may be used to understand the operational status of the structure in real-time.

Ohodnicki, Paul R.↗

The co-located arrangement of ECEI and MIR microwave imaging diagnostics on EAST tokamak

The co-located configuration of Passive Electron Cyclotron Emission Imaging (ECEI) and active Microwave Imaging Reflectometry (MIR) diagnostics systems has been successfully implemented on the EAST fusion reactor. These advanced 2D microwave diagnostic tools offer 10–20 mm poloidal spatial resolution through large aperture quasi optics. This arrangement not only optimizes the utilization of limited observation windows but also facilitates concurrent measurements of plasma density and electron temperature at specific toroidal positions. Furthermore, this co-located setup holds great promise for enhancing research into electron heat transport and other pivotal plasma phenomena.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Electron density profile and associated fluctuation measurements using a microwave reflectometry diagnostic on Helically Symmetric eXperiment (HSX)

Abstract A dual-band frequency-modulated reflectometry is employed on the Helically Symmetric eXperiment (HSX) stellarator. This system equips a fast PIN switch to alternate the frequency source between two voltage-controlled oscillators, providing an operational frequency range from 14.5 GHz to 25.5 GHz. A monostatic antenna geometry and an ellipsoidal mirror are implemented in the vessel of HSX, where the polarization of the transmitted microwave can be switched between O- and X-mode to accommodate the magnetic field and plasma density. Although the original system was designed for density fluctuation measurement, significant efforts have been undertaken to improve the system performance and to realize the density profile inversion. Recent improvements of the system reported here include calibration of the dispersion in the transmission line, optimization of the waveform, and implementation of the Choi-Williams time–frequency distribution for spectral analysis. In this paper, we present the optimization of the reflectometry system along with first experimental measurements of the density profile and observations of fluctuations during gas puffing experiments.

Han, X. (ORCID:0000000184986433)↗

The 140 GHz notch filter development for millimeter-wave diagnostics protection on the stellarator Wendelstein 7-X

The notch filter plays a crucial role as a protective component in microwave diagnostics, primarily by addressing issues related to catastrophic interference. Designed for millimeter-wave diagnostics on the stellarator Wendelstein 7-X (W7-X), a WR-6 waveguide-based notch filter has been successfully developed to effectively isolate leakage from auxiliary heating gyrotrons operating at 140 GHz. The filter incorporates cylindrical cavities resonating at 140 GHz for the TE11p mode, with coupling structures that are designed and optimized for high-efficiency coupling. This configuration simplifies fabrication, thereby ensuring high-yield production. Experimental fabrication and in-house characterization confirm the notch filter's exceptional performance, with over 60 dB rejection in the vicinity of 140 GHz and low insertion loss (< 2 dB) above and below the notch frequency across a broad frequency bandwidth (121–138 GHz, 142–163 GHz). Furthermore, the utilization of this high-frequency structure fabrication technology can be applied to millimeter-wave diagnostics on other machines. In addition to the design elements of the notch filter, this paper also provides a detailed discussion of the fabrication process and methodology.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Diagnostics: Chapter 8 of the special issue: on the path to tokamak burning plasma operation

This chapter presents the activity conducted by the ITPA topical group (TG) on Diagnostics over about the last 15 years. Following a general introduction of the ITER Diagnostics led by their measurement roles, the document is organized in several subchapters detailing the design support, research and development activity conducted by each of the specialist working groups (WGs) of the TG. Please note that the magnetic diagnostics were supported at the TG without a specific WG. Their status is included in the general introduction. In the following some highlights of the subchapter’s contents are provided. Recent advances in ITER first wall (FW) diagnostics for the measurements of plasma-metallic wall interaction in support of the ITER research plan are reported. An InfraRed imaging Video Bolometer for ITER has been developed and tested on several tokamaks to measure the radiated power loss. A laser-induced breakdown spectroscopy (LIBS) technique which utilizes a pulsed laser beam to ablate locally by forming a crater, will measure local tritium inventory in the FW material. Real-time Residual Gas Analyzers will measure the neutral gas composition in a divertor port and an equatorial port during plasma operation. Due to the full metallic FW environment, the plasma-wall interaction in ITER will face several challenges such as the compromised radiated power and divertor heat flux measurements by reflection. Ray tracing and analysis codes have been developed to eliminate and correct the effects of reflection in the measurements. The characteristics of the reflecting surfaces depending on the roughness and angle of the incidence have been measured by dedicated experiments, and the results were applied to the reflection elimination. For the measurement of the metallic impurity radiation induced by eroded metallic atoms, a vacuum ultraviolet spectrometer has been developed and tested. An extensive thermonuclear diagnostic suite will be required to support the operation of ITER and the planned experimental program for future burning plasma experiments. Due to the harsh environmental conditions, the implementation of diagnostic systems in ITER is a major challenge. These conditions include high levels of neutron and gamma fluxes, neutron heating, particle bombardment. Therefore, the selection and design of diagnostic systems must take into account a number of phenomena previously unseen in diagnostic design. For this reason, the measurement of neutrons and confined or lost fast ions, with particular emphasis on alpha particles, is critical to ITER. The diagnostics associated with these measurements will be important for future plasma-burning experiments at ITER. The high neutron emission and very large plasma size in ITER make neutron diagnostics the main diagnostic method used to measure plasma parameters such as fusion power, fusion power density, ion temperature, energy of fast ions and their spatial distributions in the plasma core. Active spectroscopy techniques are methods where a neutral particle beam is injected into the plasma and information on plasma parameters is extracted from the measurement of line emission resulting from the beam-plasma interaction, either by plasma ions or by beam atoms. Spatial localization is achieved by crossing the beamline and multiple observation lines. The ITER plasma will be a high temperature, moderately dense, fully ionized collisional plasma. The plasma facing surfaces are principally metallic being fashioned from beryllium or tungsten but many other elements, arising from either structural or from operational needs, may enter this plasma. The energy range of the emitted photons range from meV (infra-red) to multi keV (x-rays) and originate from all areas of the plasma volume. The primary role of passive emission diagnostics is to identify what is in the plasma from spectral signatures. Extracting quantitative information from these measurements such as impurity content, ion temperature, rotation, degree of detachment and radiated power depends on calibrated instruments, a physics model of the atomic and molecular processes and plasma transport and an analysis workflow that takes into account environmental effects such as reflections. The particular needs for ITER have prompted a multi-machine, many-year effort to address all these aspects and this chapter reviews the work on diagnostic design, experiments and new analysis techniques. An overview of the laser diagnostics to be implemented on ITER is also provided in this paper. This includes descriptions of the Thomson scattering in the core, edge and divertor regions, polarimetry and interferometry diagnostics used for measuring plasma density and also measurements of helium density in the divertor using Laser Induced Flourescence. Techniques which can allow improvements on current measurements are also addressed in particular expanding poloidal polarimetry measurements to measure field fluctuations and proposed use of dispersion interferometery which has a number of advantages over existing methods. This paper identifies particular areas where further research and testing on existing tokamaks is useful even at this advanced stage to inform the design of diagnostics for ITER. Outstanding areas of concern for the implementation of laser diagnostics, in particular with a view to reliable operation are identified. An overview of the latest developments of microwave diagnostic systems and techniques is given. The primary focus is the contributions for ITER—the next step burning plasma experiment—which is supplemented by describing recent progress of techniques applicable for fusion experiments beyond ITER. The contributions are intentionally kept concise, and are being supplemented by a rich list of references for further studies. Radiation induced effects are receiving continuous and well-deserved attention of the ITER diagnostic community and they are in many cases one of the primary design drivers of the ITER diagnostic systems. The paper summarizes recent progress in this area focusing primarily on the ITER diagnostics but in some cases provides also outlook for the possible solutions for even more demanding radiation environment of fusion reactors beyond ITER. Despite advancements in the area of modeling and simulation of various radiation induced effects, experimental testing in a nuclear environment as close as possible to the target one is still seen as unavoidable for proper qualification of particular diagnostic functional elements. Recent advancement within three diagnostic areas: optical diagnostics, magnetics and bolometers is covered. Encouraging results on qualification of silica glass vacuum window assemblies are presented. In the area of magnetic sensors, progress of irradiation tests performed on ITER in-vessel LTCC inductive sensors is presented with outlook for novel technological approaches to inductive sensors utilizing thick printing and photolithography technologies being highlighted. Summary of advancements in the area of steady state magnetic field sensors based on Hall effect is given. New results of neutron irradiation test of the ITER borosilicate glass inserts for vacuum electrical feedthroughs are summarized finding negligible swelling at target level of neutron fluence. Off-line irradiation tests of fiber optic current sensors for plasma current measurement demonstrated that both for gamma doses up to 5 MGy and a total neutron fluence up to 10 15 cm −2 , radiation induced changes are still compatible with required measurement accuracy on ITER. The ITER bolometers are given as an example how considering radiation effects may influence the diagnostic design. Finally, outlook for future main R&D directions is outlined. All optical and laser-based diagnostics in ITER will be using mirrors to guide plasma radiation toward detectors, cameras and sensors. In the hostile plasma, radiation and particle environment the optical characteristics of diagnostic mirrors will degrade directly affecting the entire performance of involved diagnostic systems. An assessment of factors affecting mirror performance is provided. Among the prime adverse factors are deposition of plasma impurities, sputtering of mirror surface and steam ingress in the vicinity of mirrors. Within the International Tokamak Physics Activity with active support by ITER central team and domestic agencies, the structured research and development (R&D) program on mitigation of risks for diagnostic mirrors is underway. Within this program the mirror material development, the passive mitigation of mirror degradation by using diagnostic ducts and shutters along with an active mirror recovery program comprising the in-situ mirror cleaning and calibration is underway. Recent developments in diagnostic mirror R&D are described in this Chapter along with an example of their implementation of R&D solutions in ITER Infrared Thermography diagnostic. An assessment of still open engineering and physics questions, considerations on mirror risks during an early phase of ITER operation are given along with an overview of diagnostic mirror evolution in the late ITER operation stage toward the demonstration fusion power plant. Several crucial areas of diagnostic R&D outlined in ITER Research Plan are addressed. The basic control groups in a fusion reactor can be broken-down in five categories: (1) plasma position, magnetic configuration, and plasma current control, (2) profile control and confinement optimization, (3) MHD control and suppression, (4) edge dissipation control, radiation and plasma exhaust control and (5) break-down optimization. These categories are coupled via the physics (a control action in one domain will affect the other domains) and via shared actuators (e.g. ECRH for impurity accumulation avoidance, current density distribution control and MHD suppression). Consequently, a supervisory control system should determine the priority of the various control tasks, their couplings, and the interfaces with the safety and interlock system. For the systematic development of the various controllers taking the complexity of the plasma and the control system into account, a model-based approach is required. A short historical overview is given of the developments in systems and control theory and control engineering with special emphasis on those developments that are most relevant for Nuclear Fusion research and operation. An overview is given of the state of the field of fusion plasma control for the control categories. It will be shown how synthetic diagnostics are being developed in ITER and how they are used in diagnostic design and design validation and how they can be in model-based controller synthesis using relatively simple models. In modern control methods, multiple diagnostics are used to constrain relatively simple models. The constrained models provide an estimate for the state. This opens the route to state controllers, such as model predictive control. A major challenge in nuclear fusion research is the coherent combination of data from heterogeneous diagnostics and modeling codes for machine control and safety as well as physics studies. Measured data from different diagnostics often provide information about the same subset of physical parameters. Additionally, information provided by some diagnostics might be needed for the analysis of other diagnostics. A joint analysis of complementary and redundant data allows, e.g. to improve the reliability of parameter estimation, to increase the spatial and temporal resolution of profiles, to obtain synergistic effects, to consider diagnostics interdependencies and to find and resolve data inconsistencies. Physics-based modeling and parameter relationships provide additional information improving the treatment of ill-posed inversion problems. A coherent combination of all kind of available information within a probabilistic framework allows for improved data analysis results. The concept of integrated data analysis (IDA) in the framework of Bayesian probability theory is outlined and contrasted with conventional data analysis. Components of the probabilistic approach are summarized and specific ingredients beneficial for data analysis at fusion devices are discussed.

ITER↗

Coherent microwave scattering for diagnostics of small plasma objects: A review

Measurements of parameters of small-size plasmas are very challenging because many traditional diagnostic approaches cannot be used. Constructive coherent microwave scattering (CMS) offers a convenient diagnostic solution for such small plasmas. This work reviews the development and applications of constructive coherent microwave scattering by the Electric Propulsion and Plasma Laboratory at Purdue University. It presents fundamentals of CMS with an emphasis on Thomson, collisional, and Rayleigh scattering in short, thin, unmagnetized plasma media. Additionally, we review examples of CMS application for diagnostics of temporally resolved plasma dynamics and electron decay, photoionization rates, electron momentum-transfer collision frequencies, and number densities of selective species in gaseous mixtures. These applications are relevant for various research fields including strong field and femtosecond filamentation physics, plasma-assisted ignition and combustion, and combustion and spacecraft electric propulsion diagnostics.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Photoionization of seeded combustion products as a method of enhancing the efficiency of magnetohydrodynamic power generators

Here, in this study, we performed an experimental and computational investigation into the feasibility of utilizing photoionization to enhance the electrical conductivity of seeded oxy-fuel combustion products and improve the performance of magnetohydrodynamic (MHD) power generators. We applied a variety of optical and microwave diagnostics to study the ionization and recombination processes of potassium excited by an excimer laser in a high-velocity oxy-fuel free jet. Computational fluid dynamic (CFD) simulations were performed to model the thermophysical properties and species densities of the free jet. The CFD results were validated with position-dependent potassium concentration measurements. Electron recombination exponential lifetimes were measured through time-resolved microwave transmission. The experimental electron lifetimes were compared with lifetimes calculated from CFD-predicted species densities and literature recombination rates. It was determined that K + or O 2 are the most likely recombination partners for photoionized electrons. Time-resolved fluorescence measurements provided evidence of an ionization pathway involving a two-photon ionization of KOH . Finally, a zero-dimensional chemical kinetic model was developed to assess the fundamental viability of inducing a non-equilibrium electron population to provide a net energy return in combustion-driven MHD power generators. We determined that a high energy return is feasible for targeting electrode boundary layers with ultraviolet photoionization. We also found that photoionization could potentially lower the required temperature of the bulk gas flow.

20 FOSSIL-FUELED POWER PLANTS↗

Electron Cyclotron Emission–Based Separatrix Identification in ITER with OMFIT Synthetic Modeling

Accurate determination of the separatrix location is essential for understanding edge plasma behavior and optimizing confinement in tokamaks, especially in next-generation devices such as ITER. In this study, a synthetic microwave diagnostics module was developed and implemented in the OMFIT framework to assess the feasibility of an electron cyclotron emission–based separatrix detection method in ITER plasmas. Simulations were carried out using ITER H-mode equilibrium scenarios with different plasma density profiles and different pedestal widths. Here, the results show that the electron emission temperature profiles consistently exhibit an inversion pattern near the edge, with a well-defined minimum point that could serve as a proxy for the separatrix location. However, unlike in the DIII-D, the minimum point in ITER is systematically offset by approximately 2 cm into the scrape-off layer, independent of density or pedestal width, which is within the radial resolution range (2 to 5 cm) determined by the 500-MHz channel spacing. While the method does not provide the exact separatrix location, it offers a reliable indicator of the boundary region and has potential applications for real-time boundary monitoring in ITER and other future fusion devices.

Electron cyclotron emission↗

Momentum transfer interaction of a laser-produced plasma with a low-pressure background.

The expansion of a laser-produced metallic plasma into a photoionized hydrogen background has been experimentally studied. Langmuir probe and microwave diagnostics have detected an interaction front which decelerates with a dependence on background density and time consistent with a momentum coupling between the laser plasma and the ionized fraction of the background. An ion percursor has also been observed. Calculations of scattering cross sections indicate that multiple-encounter Coulomb scattering will dominate collisional momentum transfer. The leading edge of the laser plasma contains multiply charged ions of charge state z greater than or equal to 5, and collisional effects appear adequate to explain the principal features of the momentum coupling. The ion precursor may have a collisionless origin.

Koopman, D. W.↗

High-beta effects and anomalous diffusion in plasmas expanding into magnetic fields

A metallic laser-produced plasma is allowed to expand transversely into an applied magnetic field, under conditions where the typical ion cyclotron radius is much larger, and the electron cyclotron radius much smaller, than the experimental dimensions. A stationary background plasma may also be present. Initially, the flow energy density exceeds (B squared/8 times pi), where B is the ambient magnetic field. Magnetic coil probes, Langmuir probes, and microwave diagnostics are used to study the plasma-field interaction. Field compression at the leading edge and field exclusion within the expanding plasma are seen. The diagnostic measurements and comparison with a theoretical model demonstrate plasma turbulence and anomalously high diffusion of field into the expanding plasma.

Koopman, D. W.↗