Search NASASearch

SEARCH · Search NASA

Results for “Microwave Radiometer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

QS ATMS Calibration Data Book Government Version: Pre-Launch Version

The Advanced Technology Microwave Sounder (ATMS) SN301 is an instrument onboard the QuickSounder Satellite System, QuickSounder mission (renamed QS). Throughout this document the mission may be referred to as QuickSounder or QS. The purpose of this document is to provide information needed to interpret and process QS ATMS science data. The contents of the data book incorporate results from pre-launch subsystem-level and instrument-level testing as well as post-launch testing performed during instrument commissioning. Major milestones include instrument thermal vacuum (TVAC) testing in May 2024 and observatory TVAC testing in 2026. QS launch will be no earlier than Feb. 15, 2027.

Microwave Radiometer

The Hyperspectral Microwave Photonic Instrument (HyMPI) and its NEDT Performance

This work presents an overview of a hyperspectral microwave-photonic spectrometer and demonstrates the system end-to-end noise equivalent delta temperature (NEDT) performance. The system aims at augmenting the remote sensing capability from space, with a focus on the Earth’s planetary boundary layer (PBL) thermal microwave (MW) spectral region (0-200 GHz). Combining a Photonic Integrated Circuit (PIC) channelizer and an application-specific integrated circuit (ASIC) spectrometer, the PIC & ASIC (PICASIC) module is capable of processing 40 GHz spectra at hyperspectral (4 MHz) resolution. The photonic technology is agnostic to the spectral region and multiple photonic modules can cover the entire 200 GHz spectrum. Measured results of the end-to-end system NEDT agree with predicted values confirming that the NEDT is primarily dominated by the noise figure of the MW front-end, with the optical link adding no significant noise. The data also demonstrate that a single module enables simultaneous super- and hyper-spectral resolution channel analysis across a 40 GHz range.

spectrometer

The Canadian Galactic Emission Mapper (CGEM) A Cosmic Microwave Foreground Experiment

The Canadian Galactic Emission Mapper (CGEM) is a 4-meter single-dish radio telescope located at the Dominion Radio Astrophysical Observatory (DRAO) in Penticton, Canada. CGEM is designed to map polarized Galactic synchrotron emission across the entire northern sky at 8-10 GHz with 1 MHz frequency resolution and ∼ 0.5 degree angular resolution. Its goal is to obtain high-fidelity, low-noise maps of polarized Galactic synchrotron radiation, at frequencies where synchrotron dominates, in order to provide a reliable template for CMB B−mode foreground cleaning. We will show on sky performance of CGEM’s single-pixel azimuthally-symmetric telescope, its coherent, dual-polarized radiometer, and show maps made from commissioning data from the first few months of operation.

Cosmic microwave background

NASA Scatterometer Oceanic Wind Measurement System

Satellite scatterometers are active microwave radars designed to yield measurements of near surface horizontal wind velocity over the ocean. Scatterometers are unique in that they are the only existing microwave remote sensing instruments that allow measurements of both wind speed and wind direction. NASA will fly a scatterometer, NSCAT, aboard the Navy Ocean Remote Sensing System (N-ROSS) mission starting in late 1990. N-ROSS is a spaceborne ocean remote sensing system with a planned mission life of three years. In addition to the NSCAT, N-ROSS will have three other microwave instruments mounted on a single satellite flying in a near polar orbit: an altimeter; a special sensor microwave/imager (SSM/I); and a low frequency microwave radiometer. The NSCAT to be flown on N-ROSS is described.

M Freilich

Updated global and regional trends of stratospheric ozone profiles

We present updated evaluation of stratospheric ozone profile trends in the 60° S–60°N latitude range using long-term ground-based and satellite climate data records, as well as simulations by chemistry-climate models. The trends are evaluated using the LOTUS (Long-term Ozone Trends and Uncertainties in the Stratosphere) regression model. Analyses of satellite data confirm the statistically significant positive ozone trends in the period 2000–2024 in the upper stratosphere of ~1–3% per decade, with larger trends at mid-latitudes compared to the tropics. The trends are slightly positive or close to zero in the middle stratosphere, and mostly negative, -1 to -2% per decade, in the lower stratosphere, but they are not statistically significant. The morphology and magnitude of ozone trends are similar to previous analyses (2000–2020 trends). Ozone trends in 2000–2024 predicted by chemistry-climate model simulations are in good agreement with combined satellite trends. In the upper stratosphere, models predict a slightly stronger ozone recovery than observations. In the lower stratosphere, both models and satellite observations report negative trends in the tropics, while modelled ozone trends are slightly positive at mid-latitudes. Ozone profile trends over several stations estimated from ground-based records capture the same overall vertical pattern of ozone trends as merged gridded satellite datasets. Analyses of regional ozone profile trends in 2003–2024 using merged satellite datasets confirmed the previous observations of a longitudinal structure in ozone trends in the NH mid-latitude stratosphere, with positive trends over Scandinavia and negative trends over Siberia. However, the magnitude of this dipole-like structure is reduced compared to previous analyses.

trends

Operational Correction for the Temperature Dependence of A Class of Hyperspectral Radiometers

The correction for temperature response of optical radiometers implies access to their working temperature (i.e., either the internal or ambient one with the radiometers in thermal equilibrium). With specific reference to a class of widely used hyperspectral radiometers lacking a thermistor to measure the internal temperature, this work investigated the potential for operational corrections relying on the ambient temperature derived from the radiometer dark digital counts. With the objective to keep within approximately 1% the uncertainty for radiometric corrections in the 400–800-nm spectral range, findings showed the applicability of the method for ambient temperatures higher than approximately 30°C. The alternative use of an ambient temperature proxy, determined from the air temperature incremented by a few degrees Celsius, was shown a valid solution to constrain the uncertainty of radiometric corrections to within 1% over the entire 0°–40°C interval.

Giuseppe Zibordi

Incremental Learning for Passive Microwave Precipitation Retrievals using Advanced Technology Microwave Sounder

Spaceborne passive microwave (PMW) radiometry is central to global precipitation monitoring, yet retrieval uncertainties remain substantial, particularly for cross-track sounders whose variable footprints and channel configurations are optimized for atmospheric temperature and moisture profiling rather than precipitation. Consequently, existing operational products often exhibit angular-dependent biases, limited effective swath utilization, unrealistic rainfall probability distributions, and systematic misclassification of precipitation phase. These limitations are further compounded by the scarcity of globally accurate and representative precipitation observations, as training data from the Dual-frequency Precipitation Radar (DPR) and the Cloud Profiling Radar (CPR) are spatially sparse, lack uniform global coverage, and exhibit heterogeneous error characteristics across precipitation regimes. To address these challenges, this study presents a supervised retrieval algorithm that incrementally trains an ensemble of extreme gradient-boosted decision trees by augmenting base learners with pre-training on reanalysis data and post-training on coincident DPR and CPR observations matched with the Advanced Technology Microwave Sounder (ATMS). By transferring prior information from reanalysis to posterior constraints from radar observations and adopting a sequential detection–estimation strategy for precipitation phase and rate retrieval, the proposed approach yields retrievals across the full ATMS swath that are largely free from persistent deficiencies in current Global Precipitation Measurement (GPM) passive microwave operational products. In particular, the method resolves bimodal artifacts in rainfall retrievals and mitigates systematic high-latitude snowfall biases, including overestimation across the Arctic and underestimation across the Antarctic. Validation against independent Multi-Radar Multi-Sensor (MRMS) data over the Contiguous United States (CONUS) further demonstrates improved performance in precipitation phase detection and rate estimation relative to both reanalysis and current GPM PMW products.

Mahyar Garshasbi

Integrated optical frequency division for microwave and mmWave generation

Abstract The generation of ultra-low-noise microwave and mmWave in miniaturized, chip-based platforms can transform communication, radar and sensing systems 1–3 . Optical frequency division that leverages optical references and optical frequency combs has emerged as a powerful technique to generate microwaves with superior spectral purity than any other approaches 4–7 . Here we demonstrate a miniaturized optical frequency division system that can potentially transfer the approach to a complementary metal-oxide-semiconductor-compatible integrated photonic platform. Phase stability is provided by a large mode volume, planar-waveguide-based optical reference coil cavity 8,9 and is divided down from optical to mmWave frequency by using soliton microcombs generated in a waveguide-coupled microresonator 10–12 . Besides achieving record-low phase noise for integrated photonic mmWave oscillators, these devices can be heterogeneously integrated with semiconductor lasers, amplifiers and photodiodes, holding the potential of large-volume, low-cost manufacturing for fundamental and mass-market applications 13 .

Science & Technology - Other Topics

Systematic Construction of Time-Dependent Hamiltonians for Microwave-Driven Josephson Circuits

Time-dependent electromagnetic drives are fundamental for controlling complex quantum systems, including superconducting Josephson circuits. In these devices, accurate time-dependent Hamiltonian models are imperative for predicting their dynamics and designing high-fidelity quantum operations. Existing numerical methods, such as black-box quantization (BBQ) and energy-participation ratio (EPR), excel at modeling the static Hamiltonians of Josephson circuits. However, these techniques do not fully capture the behavior of driven circuits stimulated by external microwave drives, nor do they include a generalized approach to account for the inevitable noise and dissipation that enter through microwave ports. Here, we introduce numerical techniques that leverage classical microwave simulations, efficiently executable in finite-element solvers, to obtain the time-dependent Hamiltonian of microwave-driven superconducting circuits with arbitrary geometries under charge, flux, or mixed electromagnetic modulation. Importantly, our techniques do not rely on a lumped-element description of the superconducting circuit, in contrast to previous approaches to tackling this problem. We demonstrate the versatility of our approach by characterizing the driven properties of realistic circuit devices in complex electromagnetic environments, including coherent dynamics due to charge and flux modulation, as well as drive-induced relaxation and dephasing. Our techniques offer a powerful toolbox for optimizing circuit designs and advancing practical applications in superconducting quantum computing.

Lu, Yao [Yale U.; Yale U. (main); Fermilab] (ORCID

The Thermal and Kinematic Sunyaev–Zeldovich Effect in Galaxy Clusters and Filaments Using Multifrequency Temperature Maps of the Cosmic Microwave Background A399–A401 Cluster Pair Case Study

We present a multifrequency and multi-instrument methodology to study the physical properties of galaxy clusters and cosmic filaments using cosmic microwave background observations. Our approach enables simultaneous measurement of both the thermal (tSZ) and kinematic Sunyaev–Zeldovich (kSZ) effects, incorporates relativistic corrections, and models astrophysical foregrounds such as thermal dust emission. We do this by jointly fitting a single physical model across multiple maps from multiple instruments at different frequencies, rather than fitting a model to a single Compton-y map. We demonstrate the success of this method by fitting the A399–A401 galaxy cluster pair and filament system using archival data from the Planck satellite and new, targeted deep data from the Atacama Cosmology Telescope, covering 11 different frequencies over 14 maps from 30 GHz to 545 GHz. Our tSZ results are consistent with previous work using Compton-y maps. We measure the line-of-sight peculiar velocities of the cluster–filament system using the kSZ effect and find statistical uncertainties on individual cluster peculiar velocities of ≲600 km s −1 , which are competitive with current state-of-the-art measurements. Additionally, we measure the optical depth of the filament component with a signal-to-noise of 8.5σ and reveal hints of its morphology. This modular approach is well-suited for application to future instruments across a wide range of millimeter and submillimeter wavebands.

Ajay S Gill

Introduction to the JPSS-2 Advanced Technology Microwave Sounder (ATMS) Government Calibration Data Book (GCDB)

The third Advanced Technology Microwave Sounder (ATMS) is an instrument onboard the Joint Polar Satellite System (JPSS), JPSS-2 (renamed NOAA-21 in orbit) mission. This report is to introduce the JPSS-2 Government Calibration Data Book (J2 GCDB) for ATMS, SN 304. This J2 GCDB document contains key information generated during the calibration testing campaign that is driving parameters for radiometric performance. This document also contains supporting data that augments the calibration results. The values in this document are utilized by ATMS’s calibration packet which is, in turn, an integral component in the interpretation of science data. The calibration data in this report was collected from tests such as shelf-level testing, antenna testing, instrument thermal vacuum (TVAC) testing; satellite TVAC testing; and JPSS-2 post-launch tests. JPSS-2 was launched on November 10, 2022. In the subsequent years, the Government will release an ATMS GCDB for each JPSS mission. We expect that all public users can download these ATMS GCDBs from the NOAA operational Integrated Calibration and Validation System (ICVS) website, see more discussions below. The goal of this GCDB is to demonstrate how to characterize ATMS measurements using JPSS-2 ATMS on-orbit operational data and to provide relevant explanations. This document serves as a primary public domain reference for calibrating operational ATMS Raw Data Records (RDR) science data, as used in the current operational Interface Data Processing Segment (IDPS) system. This same RDR science data is distributed through direct broadcast (DB) to DB users for use in their ground processing systems. This J2 GCDB provides the results of the ATMS system radiometric calibration, the antenna flat reflector emissivity [1], the antenna pattern measurements, the antenna pattern corrected brightness temperature [2], the brightness temperature of the lunar disk [3], Lunar Intrusion (LI) correction algorithm [4], receiver spectral parameters, and mechanical alignment on-orbit pointing results, and the striping effect appeared significantly in S-NPP on-orbit radiance data when the data are compared to the Radiative Transfer Model (RTM) simulation in numerical weather prediction (NWP) system [5]. It also provides the parameters required for conversion of telemetry counts to engineering units, for radiometric calibration, and for antenna beam geo-location. Moreover, it provides JPSS-2 ATMS Spectral Response Functions data, some additional information related to ATMS on-orbit performance, on-orbit lunar intrusion correction parameters and Earth contamination bias, and on how to derive ATMS RDR, antenna Temperature Data Records (TDR), and Sensor Data Records (SDR). Furthermore, an introduction of NOAA operational Integrated Calibration and Validation System (ICVS) website and services is added in this J2 GCDB. This ICVS hosts a long-term monitoring system which allows to visualization and comparison of data from JPSS missions, NOAA legacy Polar Operational Environmental Satellites (POES), and Geostationary Operational Environmental Satellites (GOES). From NOAA Comprehensive Large Array-data Stewardship System (CLASS), the public users can download all JPSS ATMS data products for all JPSS missions.

Microwave Sounder

The Canadian Galactic Emission Mapper: A New 8-10 GHz Telescope To Map the Polarization of the Northern Sky

The Canadian Galactic Emission Mapper (CGEM) radio telescope is mapping polarized Galactic foregrounds from 8-10 GHz to aid in the search for B-modes in the Cosmic Microwave Background (CMB). Here we describe the design and early on-sky characterization of the CGEM optics. CGEM employs an on-axis, hat feed optical design that is a body of revolution (BOR) and exhibits excellent intrinsic polarization purity. We describe how we have optimized the optics with a novel framework that can directly minimize simulated intensity to polarized intensity (T → P) leakage in angular power spectrum space. The optimized optics exhibit simulated T → P leakage that is orders of magnitude below anticipated CℓBB for r = 10 −3 when scaled from 8-10 GHz to the CMB observing window near 95 GHz. We go on to describe the mechanical design of the optics, including a novel secondary mirror support made from Astroquartz composite that has low loss, low dielectric constant, and preserves the BOR symmetry of the optics. We then showcase the early on-sky performance of the optics with observations of the Sun and satellites, which probe the beam to 40dB down from the peak. A beam model for the deployed CGEM optics based on electromagnetic simulations is in excellent agreement with the on-sky data.

cosmic microwave background

Toward Large Field-of-view X-ray Spectrometers with Magnetic Microcalorimeters

A future X-ray telescope mission like Lynx, a X-ray flagship mission concept, requires a large field of view, high energy resolution, and high spatial resolution. The Magnetic Microcalorimeter (MMC) detectors we are developing for such a mission feature a 5-arcminute field of view, approximately 100,000 pixels, each spanning 0.5–1 arcsecond. These detectors require the readout of 8,000 sensors. Three different array types have been designed to meet scientific goals, two of which utilize thermal multiplexing to reduce the number of readout channels in a scheme called “Hydra.” We are currently fabricating detectors on a recently completed buried wiring wafer with connections to every sensor. The sensors are read out using a microwave multiplexer (μMUX) with flux ramp modulation. A single μMUX can read out approximately 1,000 sensors with only two feed lines. We will report on the test of the first two-dimensional μMUX chip, consisting of 78 resonators. μMUX chips that pass screening will be directly bonded to MMC array chips using indium bump bonding. In parallel, we have tested a kinetic inductance traveling wave parametric amplifier (KI-TWPA) to amplify signals at low temperatures. The KI-TWPA exhibits extremely low internal noise, approaching the standard quantum limit. Since the energy resolution of an MMC is primarily limited by the readout system, the KI-TWPA is an ideal amplifier for MMCs with μMUX readout. We recently measured the readout noise of a μMUX with a KI-TWPA, demonstrating its capability for reading out MMC arrays. We present the design and fabrication of the latest MMC detectors, along with its readout performance.

Magntic Microcalorimeters

The Telecommunications and Data Acquisition Progress Report 42-74

This publication reports on developments in programs managed by JPL's office of Telecommunications and Data Acquisition (TDA). In space communications, radio navigation, radio science, and ground based radio astronomy, it reports on activities of the Deep Space Network (DSN) and its associated Ground Communications Facility (GCF) in planning, in supporting research and technology, in implementation and in operations. In geodynamics, the publication reports on the application of radio interferometry at microwave frequencies for geodynamic measurements. This publication also reports on implementation and operations for searching the microwave spectrum.

E C Posner

Nonequilibrium dynamics of two-level systems directly after cryogenic alternating bias

Two-level systems (TLSs) are a dominant decoherence mechanism in superconducting qubits, microwave kinetic inductance detectors, and quantum dots. TLSs are tunneling states commonly found in amorphous materials and interfaces, which interact electromechanically, leading to energy loss. Fluctuations in the frequency of the TLSs are a significant problem for qubit operation and force recalibration every few hours. In this study, we probe the effect of alternating bias at cryogenic temperatures on TLSs in a purpose-built LC oscillator. When an in situ alternating bias is applied, the steady-state spectra of the TLSs disappear. Spectroscopy reveals transient behavior, in which the TLS frequency fluctuates on the order of minutes. Thermal cycling above 10 K reverses these effects, restoring the TLS spectrum to its original state. Importantly, the intrinsic loss tangent of the LC oscillator remains unchanged before and after the application of the alternating bias. We propose that the disappearance of the steady-state spectrum is caused by nonequilibrium energy buildup from strain in the oxide film introduced by the pulsed voltage-bias sequence. Understanding this nonequilibrium energy could shed light on TLS fluctuations and reduce the calibration requirements for qubits.

general physics

Evidence for large baryonic feedback at low and intermediate redshifts from kinematic Sunyaev-Zel’dovich observations with ACT and DESI photometric galaxies

Recent advances in cosmological observations have provided an unprecedented opportunity to investigate the distribution of baryons relative to the underlying matter. In this work, we show that the gas is more extended than the dark matter, and the amount of baryonic feedback at $z \lesssim 1$ disfavors low-feedback models such as that of state-of-the-art hydrodynamical simulation IllustrisTNG compared with high-feedback models such as that of the original Illustris simulation. This has important implications for bridging the gap between theory and observations and understanding galaxy formation and evolution. Furthermore, a better grasp of the baryon-dark matter link is critical to future cosmological analyses, which are currently impeded by our limited knowledge of baryonic feedback. Here, we measure the kinematic Sunyaev-Zel'dovich (kSZ) effect from the Atacama Cosmology Telescope (ACT), stacked on the luminous red galaxy (LRG) sample of the Dark Energy Spectroscopic Instrument (DESI) imaging survey. This is the first analysis to use photometric redshifts for reconstructing galaxy velocities. Due to the large number of galaxies comprising the DESI imaging survey, this is the highest signal-to-noise stacked kSZ measurement to date: we detect the signal at 13$σ$, finding strong evidence that the gas is more spread out than the dark matter, as well as a preference for larger feedback compared to some commonly used state-of-the-art hydrodynamical simulations. Here, our work opens up the possibility of recalibrating large hydrodynamical simulations using the kSZ effect. In addition, our findings highlight the importance of properly accounting for baryonic feedback with future surveys such as LSST through direct probes such as the kSZ, and shed light on long-standing enigmas in astrophysics, such as the “missing baryon” problem.

79 ASTRONOMY AND ASTROPHYSICS

Radio Metric Errors Due to Mismatch and Offset Between a DSN Antenna Beam and the Beam of a Troposphere Calibration Instrument

Two components of the error of a troposphere calibration measurement were quantified by theoretical calculations. The first component is a beam mismatch error, which occurs when the calibration instrument senses a conical volume different from the cylindrical volume sampled by a Deep Space Network (DSN) antenna. The second component is a beam offset error, which occurs if the calibration instrument is not mounted on the axis of the DSN antenna. These two error sources were calculated for both delay (e.g., VLBI) and delay rate (e.g., Doppler) measurements. The beam mismatch error for both delay and delay rate drops rapidly as the beamwidth of the troposphere calibration instrument (e.g., a water vapor radiometer or an infrared Fourier transform spectrometer) is reduced. At a 10-deg elevation angle, the instantaneous beam mismatch error is 1.0 mm for a 6-deg beamwidth and 0.09 mm for a 0.5-deg beam (these are the full angular widths of a circular beam with uniform gain out to a sharp cutoff). Time averaging for 60-100 sec will reduce these errors by factors of 1.2-2.2. At a 20-deg elevation angle, the lower limit for current Doppler observations, the beam-mismatch delay rate error is an Allan standard deviation over 100 sec of 1.1 x 10 -14 with a 4-deg beam and 1.3 x 10 -15 for a 0.5-deg beam. A 50-m beam offset would result in a fairly modest (compared to other expected error sources) delay error (less than or equal to 0.3 mm for 60-sec integrations at any elevation angle is greater than or equal to 6 deg). However, the same offset would cause a large error in delay rate measurements (e.g., an Allan standard deviation of 1.2 x 10 -14 over 100 sec at a 20-deg elevation angle), which would dominate over other known error sources if the beamwidth is 2 deg or smaller. An on-axis location is essential for accurate troposphere calibration of delay rate measurements. A half-power beamwidth (for a beam with a tapered gain profile) of 1.2 deg or smaller is desired for calibration of all types of radio metrics. A water-vapor radiometer calibration beam of this size with very low sidelobes would require a clear aperture antenna with a diameter of at least 1.5 m if the primary water vapor sensing channel were in the 20-22 GHz range.

R P Linfield