Search NASA⌕ Search

SEARCH · Search NASA

Results for “Microwave imaging diagnostics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

The co-located arrangement of ECEI and MIR microwave imaging diagnostics on EAST tokamak

The co-located configuration of Passive Electron Cyclotron Emission Imaging (ECEI) and active Microwave Imaging Reflectometry (MIR) diagnostics systems has been successfully implemented on the EAST fusion reactor. These advanced 2D microwave diagnostic tools offer 10–20 mm poloidal spatial resolution through large aperture quasi optics. This arrangement not only optimizes the utilization of limited observation windows but also facilitates concurrent measurements of plasma density and electron temperature at specific toroidal positions. Furthermore, this co-located setup holds great promise for enhancing research into electron heat transport and other pivotal plasma phenomena.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Microwave Imaging and Holographic Diagnostic to Antennas in Cylindrical Near-Field Measurement

In this paper, the issues pertaining to microwave imaging and holographic diagnostic to antennas in cylindrical near-field measurements are addressed. The theoretical approach is based on expanding the work in [1] and [2] where a cylindrical wave expansion of the field on a cylindrical near-field surface is given. The sampling probe is modeled by its equivalent aperture current (idealized circular aperture) and incorporated into the near-field to far-field transformation. The method of steepest decent is applied to obtain the far-field. In its implementation, however, one could specify directly the angular spectrum at which the far-field is desired to be calculated without resorting to interpolation. The microwave imaging and holographic diagnostic is based on back projection where a plane wave expansion of the far-field is obtained. This approach necessitates the knowledge of the far-field at exact angular spectrum resulting from application of 2-D FFT. Hence, we were able to construct simply the near-field on a plane not necessarily on the aperture plane of the test antenna but also on planes perpendicular to the aperture plane [3]. And a 3-D high resolution and high precision antenna imaging of the test antenna is obtained from cylindrical near-field simulated measurements. In addition microwave holographic diagnostic of large NASA scatterometer radar antenna obtained from measured near-field on a cylindrical surface will be given if time permits.

Microwave Imaging Holographic↗

Frontier system-on-chip (SoC) technology for microwave diagnostics (invited)

The next generation of fusion reactors, exemplified by projects such as the Demonstration Power Plant following the International Thermonuclear Experimental Reactor, faces the monumental challenge of proving the viability of generating electricity through thermonuclear fusion. This pursuit introduces heightened complexities in diagnostic methodologies, particularly in microwave-based diagnostics. The increased neutron fluence necessitates significant reductions in vessel penetrations and the elimination of internal diagnostics, posing substantial challenges. SoC technology offers a promising solution by enabling the miniaturization, modularization, integration, and enhancing the reliability of microwave systems. After seven years of research, our team successfully pioneered the V- and W-band system-on-chip approach, leading to the development of active transmitters and passive receiver modules applied in practical settings, notably within the DIII-D tokamak project. Arrays of these modules have supported microwave imaging diagnostics. New physics measurement results from the Electron Cyclotron Emission Imaging system on DIII-D provide compelling evidence of improved diagnostics following the adoption of SoC technology. Furthermore, we achieved a breakthrough in developing an F-band SoC, advancing higher frequency capabilities for fusion devices. These achievements represent a significant leap forward in fusion diagnostic technology, marking substantial progress toward establishing reliable and efficient plasma diagnostics for future fusion reactors.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development of intelligent control module for the J-TEXT electron cyclotron emission imaging system

An Electron Cyclotron Emission Imaging (ECEI) system has been developed on the J-TEXT tokamak and employed for the multi-dimensional electron temperature fluctuation imaging measurement in 2019 campaign. The intelligent control module has been developed and been used to flexibly setup the 256-channel ECEI system configurations for different plasma scenarios. The adjustments of key parameters are merged in this module including size and position of the geometric observation window, and the dynamic range of the signal and image resolution. The user-friendly interface is also developed for the tokamak operator to set the ECEI system focusing on physics interested region. Furthermore, this module is installed close to the diagnostic system around the J-TEXT tokamak, which can be remotely controlled by authorized operators in the control room. It significantly improves ECEI flexibility and stability, and also keeps the operation technician away from the harsh radiation environment.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Progress in ITER ECE diagnostic design and integration

The ITER electron cyclotron emission (ECE) diagnostic system has primary roles in providing measurements of the core electron temperature profile and the electron temperature fluctuation associated with the neoclassical tearing modes. The ITER ECE system includes a radial and oblique line-of-sight. Four 43-meter long low-loss transmission lines (TLs) are designed to transmit millimeter wave power in the frequency range of 70–1000 GHz in both X- and O-mode polarization from the port plug to the ECE instrumentation room in the diagnostic building. The measurement instrumentation includes two Fourier transform spectrometer (FTS) systems and two radiometer systems. The Indian Domestic Agency (IN-DA) and United States Domestic Agency share the responsibility. The IN-DA scope excluding instrumentation and control has passed its preliminary design review and is progressing towards the final design review (FDR). In parallel, the diagnostic integration in different areas is ongoing. Furthermore, several captive components for the TLs have passed FDR and will be manufactured for installation in the tokamak building soon. A peer review meeting has been held on the prototype hot calibration source, and its integration and new thermal analysis in the diagnostic shield module are continuing. A prototype TL is being tested. A prototype polarizing Martin-Puplett type FTS, operating in the frequency range 70–1000 GHz, features an in-vacuo fast scanning mechanism and a cryo-cooled dual-channel THz detector system. Its performance has been assessed in detail against ITER requirements.

47 OTHER INSTRUMENTATION↗

System-on-Chip approach microwave diagnostics development for burning plasma

System-on-chip (SoC) millimeter wave integrated circuit technology has been developed and employed in chip heterodyne radiometers in Electron Cyclotron Emission Imaging (ECEI) and Microwave Imaging Reflectometer (MIR) on the DIII-D tokamak for 2D electron temperature and density fluctuation diagnostics. The W-band (75-110 GHz) ECEI system has been employed with 20 poloidal horn receiver modules with customized monolithic integrated circuit chips and internal local oscillator coupling path. The new SoC approach demonstrates > 30 dB additional gain on the receiver and 95% electronics noise suppression compared to the previous Schottky diode mixer array . An F-band (110-140 GHz) receiver chip has been developed to measure MHD and turbulence behavior on the DIII-D high-field side, such as Alfven eigenmodes. Furthermore, it can image pedestal structure evolution on fusion facilities with stronger magnetic fields, such as ASDEX-U, EAST, HL-2M, and LHD. The F-band chip performance has been tested in the laboratory. Also, V-band (55-75 GHz) transmitter and receiver modules (55-75 GHz) have been developed for DIII-D and NSTX-U Furthermore, microwave Imaging Reflectometer (MIR) application suitability for 2D density fluctuation imaging on the pedestal region.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Global analyses of water vapor, cloud and precipitation derived from a diagnostic assimilation of SSM/I geophysical retrievals

An analytical approach is described for diagnostically assimilating moisture data from Special Sensor Microwave Imager (SSM/I) into a global analysis of water vapor, cloud content, and precipitation. In this method, 3D fields of wind and temperature values taken from ECMWF gridded analysis are used to drive moisture conservation equations with parameterized microphysical treatment of vapor, liquid, and ice; the evolving field of water vapor is periodically updated or constrained by SSM/I retrievals of precipitable water. Initial results indicate that this diagnostic model can produce realistic large-scale fields of cloud and precipitation. The resulting water vapor analyses agree well with SSM/I and have an additional advantage of being synoptic.

Robertson, Franklin R.↗

Vertical Profiles of Latent Heat Release and Their Retrieval for TOGA COARE Convective Systems Using a Cloud Resolving Model, SSM/I, and Ship-borne Radar Data

Latent heating profiles associated with three (TOGA COARE) Tropical Ocean and Global Atmosphere Coupled Ocean Atmosphere Response Experiment active convective episodes (December 10-17 1992; December 19-27 1992; and February 9-13 1993) are examined using the Goddard Cumulus Ensemble (GCE) Model and retrieved by using the Goddard Convective and Stratiform Heating (CSH) algorithm . The following sources of rainfall information are input into the CSH algorithm: Special Sensor Microwave Imager (SSM/1), Radar and the GCE model. Diagnostically determined latent heating profiles calculated using 6 hourly soundings are used for validation. The GCE model simulated rainfall and latent heating profiles are in excellent agreement with those estimated by soundings. In addition, the typical convective and stratiform heating structures (or shapes) are well captured by the GCE model. Radar measured rainfall is smaller than that both estimated by the GCE model and SSM/I in all three different COARE IFA periods. SSM/I derived rainfall is more than the GCE model simulated for the December 19-27 and February 9-13 periods, but is in excellent agreement with the GCE model for the December 10-17 period. The GCE model estimated stratiform amount is about 50% for December 19-27, 42% for December 11-17 and 56% for the February 9-13 case. These results are consistent with large-scale analyses. The accurate estimates of stratiform amount is needed for good latent heating retrieval. A higher (lower) percentage of stratiform rain can imply a maximum heating rate at a higher (lower) altitude. The GCE model always simulates more stratiform rain (10 to 20%) than the radar for all three convective episodes. SSM/I derived stratiform amount is about 37% for December 19-27, 48% for December 11-17 and 41% for the February 9-13 case. Temporal variability of CSH algorithm retrieved latent heating profiles using either GCE model simulated or radar estimated rainfall and stratiform amount is in good agreement with that diagnostically determined for all three periods. However, less rainfall and a smaller stratiform percentage estimated by radar resulted in a weaker (underestimated) latent heating profile and a lower maximum latent heating level compared to those determined diagnostically. Rainfall information from SSM/I can not retrieve individual convective events due to poor temporal sampling. Nevertheless, this study suggests that a good 4r, rainfall retrieval from SSM/I for a convective event always leads to a good latent heating retrieval. Sensitivity testing has been performed and the results indicate that the SSM/I derived time averaged stratiform amount may be underestimated for December 19-27. Time averaged heating profiles derived from SSM/I, however, are not in bad agreement with those derived by soundings for the December 10-17 convective period. The heating retrievals may be more accurate for longer time scales provided there is no bias in the sampling.

Tao, Wei-Kuo↗

NASA Tech Briefs, November 2009

Topics covered include: Cryogenic Chamber for Servo-Hydraulic Materials Testing; Apparatus Measures Thermal Conductance Through a Thin Sample from Cryogenic to Room Temperature; Rover Attitude and Pointing System Simulation Testbed; Desktop Application Program to Simulate Cargo-Air-Drop Tests; Multimodal Friction Ignition Tester; Small-Bolt Torque-Tension Tester; Integrated Spacesuit Audio System Enhances Speech Quality and Reduces Noise; Hardware Implementation of a Bilateral Subtraction Filter; Simple Optoelectronic Feedback in Microwave Oscillators; Small X-Band Oscillator Antennas; Free-Space Optical Interconnect Employing VCSEL Diodes; Discrete Fourier Transform Analysis in a Complex Vector Space; Miniature Scroll Pumps Fabricated by LIGA; Self-Assembling, Flexible, Pre-Ceramic Composite Preforms; Flight-speed Integral Image Analysis Toolkit; Work Coordination Engine; Multi-Mission Automated Task Invocation Subsystem; Autonomously Calibrating a Quadrupole Mass Spectrometer; Determining Spacecraft Reaction Wheel Friction Parameters; Composite Silica Aerogels Opacified with Titania; Multiplexed Colorimetric Solid-Phase Extraction; Detecting Airborne Mercury by Use of Polymer/Carbon Films; Lattice-Matched Semiconductor Layers on Single Crystalline Sapphire Substrate; Pressure-Energized Seal Rings to Better Withstand Flows; Rollerjaw Rock Crusher; Microwave Sterilization and Depyrogenation System; Quantifying Therapeutic and Diagnostic Efficacy in 2D Microvascular Images; NiF2/NaF:CaF2/Ca Solid-State High-Temperature Battery Cells; Critical Coupling Between Optical Fibers and WGM Resonators; Microwave Temperature Profiler Mounted in a Standard Airborne Research Canister; Alternative Determination of Density of the Titan Atmosphere; Solar Rejection Filter for Large Telescopes; Automated CFD for Generation of Airfoil Performance Tables; Progressive Classification Using Support Vector Machines; Active Learning with Irrelevant Examples; A Data Matrix Method for Improving the Quantification of Element Percentages of SEM/EDX Analysis; Deployable Shroud for the International X-Ray Observatory; Improved Model of a Mercury Ring Damper; Optoelectronic pH Meter: Further Details; X-38 Advanced Sublimator; and Solar Simulator Represents the Mars Surface Solar Environment.

Source record↗

Multiscale and multidimensional modeling of particle acceleration and transport in solar flares

Multi-messenger, multi-viewpoint, and time-resolved observations of solar flares are now providing unprecedented constraints on particle acceleration sites, energy conversion, and energy transport. The interpretation of current observations, including microwave imaging spectroscopy from EOVSA, hard x-ray (HXR) imaging from Solar Orbiter/STIX, gamma-ray diagnostics from Fermi, and in situ measurements from Parker Solar Probe and Solar Orbiter, collectively demands modeling frameworks that go beyond traditional spatially unresolved, one-zone models or single-mechanism descriptions. This review surveys multiscale and multidimensional modeling approaches, including kinetic, magnetohydrodynamic (MHD), and macroscopic particle models, that are being developed to meet the need. Kinetic simulations reveal that three-dimensional (3D) effects, including field-line chaos and self-generated turbulence, are essential for sustained power-law particle acceleration. MHD simulations now capture flux-rope eruptions, plasmoid-unstable current sheets, and turbulent flare regions in realistic magnetic topologies. Macroscopic models coupling MHD with energetic-particle models produce spatially resolved electron distributions and synthetic HXR and microwave emissions for direct comparison with observations. Despite these advances, outstanding challenges remain in bridging kinetic and global scales, improving MHD simulations and macroscopic particle models, and achieving quantitative model-observation closure.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Millimeter-Wave Imaging Technology Development for Real-Time 2D and 3D Fusion Plasma Diagnostics

Including a one year No-Cost Extension, The University of California, Davis has been funded since 2020 to advance innovative millimeter-wave diagnostics for fusion plasma research. This work includes: (1) Developing and applying cutting-edge System-on-Chip millimeter wave Integrated Circuit (IC) technology for Electron Cyclotron Emission Imaging (ECEI) and Microwave Imaging Reflectometry (MIR) on the DIII-D tokamak and the NSTX-U spherical tokamak. (2) Development of radiation-hardened millimeter-wave chip for diagnostics in harsh environments, utilizing wide bandgap Gallium Nitride (GaN) semiconductors. (3) Integrating forward-modeling synthetic diagnostics to enable advanced, real-time plasma prediction and feedback control. Originally planned as a three-year program (2020–2023), the project was granted a one-year no-cost extension, extending its duration through the end of 2024.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

System-on-chip integrated circuit technology applications on the DIII-D tokamak for multi-field measurements

Several mm-wave diagnostics on the DIII-D tokamak provide multi-scale and multi-dimensional measurements of plasma profile evolution and turbulence fluctuations. Mm-wave fusion plasma diagnostics that adopt system-on-chip integrated circuit technology can provide better space utilization, flexible installation, and improved sensitivity. In order to further extend this technology for additional fusion facilities with a higher toroidal magnetic field, V-band (55–75 GHz) and F-band (90–140 GHz) chips for Microwave Imaging Reflectometer (MIR) and Electron Cyclotron Emission Imaging (ECEI) instruments are developed and tested in the Davis Millimeter Wave Research Center (DMRC). Current measurement data show that correlation between these SoC-based diagnostic instruments with other state-of-the-art diagnostics enables co-located multi-field turbulence fluctuation measurement.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Planned improvements to the Owens Valley frequency-agile interferometer

Three small antennas will be added to the OVRO interferometer to form a five-element solar-dedicated array. This would provide up to 7 or 10 baselines (compared to the present 1 or 3). This would be sufficient to apply microwave diagnostics to most active region and burst sources. By using frequency-synthesis it would also provide an imaging capability comparable to that of an approximately 100 baseline interferometer. Expansion of the array is discussed.

Hurford, Gordon J.↗

Polarimetry in X- and Gamma-Ray Astronomy: The Ultimate Dimension

Polarization has been a powerful diagnostic tool in radio, microwave, and visible astronomy, providing details of photonproduction mechanisms on much smaller scales than can bedirectly imaged or deduced from photon intensity and energyalone. While polarimetry at other these wavebands (radio,microwave, and optical) is an established technique, highenergy astrophysics lags far behind in this respect. Yet polarizationanalysis has the potential of revealing many detailsabout the magnetic fields, geometries, and emission mechanismsfound in high energy emitting sources. Deviations fromspherical symmetry and/or the presence of ordered magneticfields give rise to polarized radiation: some examples includeanisotropy in solar flares, the presence of jets in microquasarsand blazars, accretion disks around stellar and massive blackholes, accreting and rotation-powered pulsars, and beams ingamma-ray bursts. In addition, null polarization detectionsfrom gamma-ray bursts at x-ray energies have been usedas a test of fundamental physics by placing limits on the possibleviolation of Lorentz invariance.

Hunter, Stanley D.↗

Design of microwave broadband CMOS transmitter and receiver circuits for MIR and ECEI plasma diagnostics

To efficiently determine the plasma electron density fluctuations using the MIR diagnostic technique, a 55–75 GHz 65 nm-CMOS transmitter has been developed where four separate intermediate frequency (IF) signals are up-converted, amplified, and then combined to generate an 8-tone RF output; a broadband 90 nm-CMOS receiver has also been constructed, which consists of an RF-low noise amplifier (LNA), mixer, and IF amplifier. The circuits and their corresponding modules will soon be deployed on the DIII-D and NSTX-U fusion devices. A 110–140 GHz 65 nm-CMOS receiver has also been designed, which is suitable for measuring the deep-core temperature fluctuations in the DIII-D tokamak using the electron cyclotron emission imaging diagnostic system. In addition to the RF-LNA/balun, mixer, and IF amplifier, an LO balun/tripler and driving amplifier are now included in this highly integrated circuit chip. By adopting the microwave and millimeterwave system-on-chip concept in the front-end system design, this paper demonstrates that compact transmitter and receiver modules can be easily built, which, in turn, facilitates array implementation and maintenance.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

System-on-chip upgrade of millimeter-wave imaging diagnostics for fusion plasma

Monolithic, millimeter wave “system-on-chip” technology has been employed in chip heterodyne radiometers in a newly developed Electron Cyclotron Emission Imaging (ECEI) system on the DIII-D tokamak for 2D electron temperature and fluctuation diagnostics. The system employs 20 horn-waveguide receiver modules each with customized W-band (75–110 GHz) monolithic microwave integrated circuit chips comprising a W-band low noise amplifier, a balanced mixer, a ×2 local oscillator (LO) frequency doubler, and two intermediate frequency amplifier stages in each module. Compared to previous quasi-optical ECEI arrays with Schottky mixer diodes mounted on planar antennas, the upgraded W-band array exhibits >30 dB additional gain and 20× improvement in noise temperature; an internal eight times multiplier chain is used to provide LO coupling, thereby eliminating the need for quasi-optical coupling. The horn-waveguide shielding housing avoids out-of-band noise interference on each module. The upgraded ECEI system plays an important role for absolute electron temperature and fluctuation measurements for edge and core region transport physics studies. An F-band receiver chip (up to 140 GHz) is under development for additional fusion facilities with a higher toroidal magnetic field. Visualization diagnostics provide multi-scale and multi-dimensional data in plasma profile evolution. Finally, a significant aspect of imaging measurement is focusing on artificial intelligence for science applications.

47 OTHER INSTRUMENTATION↗

The Impact of the Evolving Satellite Data Record on Reanalysis Water and Energy Fluxes During the Past 30 Years

Retrospective analyses (reanalyses) use a fixed assimilation model to take diverse observations and synthesize consistent, time-dependent fields of state variables and fluxes (e.g. temperature, moisture, momentum, turbulent and radiative fluxes). Because they offer data sets of these quantities at regular space / time intervals, atmospheric reanalyses have become a mainstay of the climate community for diagnostic purposes and for driving offline ocean and land models. Of course, one weakness of these data sets is the susceptibility of the flux products to uncertainties because of shortcomings in parameterized model physics. Another issue, perhaps less appreciated, is the fact that the discreet changes in the evolving observational system, particularly from satellite sensors, may also introduce artifacts in the time series of quantities. In this paper we examine the ability of the NASA MERRA (Modern Era Retrospective Analysis for Research and Applications) and other recent reanalyses to determine variability in the climate system over the satellite record (~ the last 30 years). In particular we highlight the effect on reanalyses of discontinuities at the junctures of the onset of passive microwave imaging (Special Sensor Microwave Imager) in late 1987 as well as improved sounding and imaging with the Advanced Microwave Sounding Unit, AMSU-A, in 1998. We examine these data sets from two perspectives. The first is the ability to capture modes of variability that have coherent spatial structure (e.g. ENSO events and near-decadal coupling to SST changes) and how these modes are contained within trends in near global averages of key quantities. Secondly, we consider diagnostics that measure the consistency in energetic scaling in the hydrologic cycle, particularly the fractional changes in column-integrated water vapor versus precipitation as they are coupled to radiative flux constraints. These results will be discussed in the context of implications for science objectives and priorities of the NASA Energy and Water Cycle Study, NEWS.

Robertson, Franklin R.↗

Combined microwave and laser Rayleigh scattering diagnostics for pin-to-pin nanosecond discharges

In this work, the temporal decay of electrons produced by an atmospheric pin-to-pin nanosecond discharge operating in the spark regime was measured via a combination of microwave Rayleigh scattering (MRS) and laser Rayleigh scattering (LRS). Due to the initial energy deposition of the nanosecond pulse, a variation in the local gas density occurs on the timescale of electron decay. Thus, the assumption of a constant collisional frequency is no longer applicable when electron number data are extracted from MRS measurements. Furthermore, to recalibrate MRS measurements throughout the electron decay period, temporally resolved LRS measurements of the local gas density were performed over the event duration. The local gas density was calculated to be 30% of the ambient level during the later stages of electron decay, and it recovers at about 1 ms after discharge. A shock front traveling approximately 500 m/s was additionally observed. Coupled with plasma volume calibration via temporally resolved intensified charge-coupled device imaging, the corrected decay curves of the electron number and electron number density are presented with a measured peak electron number density of 4.5 × 1015 cm -3 and a decay rate of ~(0.1–0.35) × 10 7 s -1 . A hybrid MRS and LRS diagnostic technique can be applied for a broad spectrum of atmospheric-pressure microplasmas where a variation in the gas number density is expected due to energy deposition in the discharge.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗