Search NASA⌕ Search

SEARCH · Search NASA

Results for “Microwaves”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Insights into Designing an Efficient and Reliable Microwave-Assisted Methane Dehydroaromatization Process: Effect of Microwave Absorber on Catalyst Performance

Microwave-assisted methane dehydroaromatization has the potential to address challenges of traditional dehydroaromatization reactions. However, catalysts for microwave-enhanced reaction systems require effective coupling of fields with the catalyst to produce heat and reach reaction temperatures. Here, this work presents an in-depth understanding of the effect of the addition of silicon carbide as a microwave absorber on catalyst performance among other variables, the viability of the microwave reactor configuration, and insights into designing an effective and reliable microwave-based methane dehydroaromatization process. The effect of other parameters including temperature, weight hourly space velocity, role of microwave absorber, and methane concentration during microwave-assisted methane dehydroaromatization reaction are studied. Mo/ZSM-5 was found to suffer from low permittivity and nonuniform heating under microwave conditions. Mixing silicon carbide powder as a microwave absorber with the catalyst was found to provide more uniform heating. When assessing the catalytic performance of the mixture, it was found that higher methane partial pressures at 2000 cc/g cat .h and a temperature range of 500-600°C produced the highest amount of benzene. The formation of graphitic carbon on the spent catalyst increased with temperature, gas-solid contact period, and methane concentration, which resulted in higher methane conversion and benzene selectivity. The study indicates that under microwave heating the presence of localized carbon enhanced catalyst life by coupling with microwave energy, leading to localized heating, and improving benzene selectivity.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Light-induced microwave noise in superconducting microwave-optical transducers

Microwave-to-optical transducers are integral to the future of superconducting quantum computing, as they would enable scaling and long-distance communication of superconducting quantum processors through optical-fiber links. However, optically induced microwave noise poses a significant challenge in achieving quantum transduction between microwave and optical frequencies. In this work, we study light-induced microwave noise in an integrated electro-optical transducer harnessing the Pockels effect of thin-film lithium niobate. We reveal three sources of added noise with distinctive time constants ranging from sub-100 ns to milliseconds. Furthermore, our results provide insights into the mechanisms and corresponding mitigation strategies for light-induced microwave noise in superconducting microwave-optical transducers and pave the way toward realizing the ultimate goal of quantum transduction.

42 ENGINEERING↗

Final Report on Development of Microwave Resonant Cavity Transducer for Fluid Flow Sensing: Development of Microwave Cavity Flow Meter for Advanced Reactor High Temperature Fluids

We are investigating a microwave resonant cavity transducer for flow sensing in the vessel of a high temperature fluid advanced reactor (AR), such as a molten salt cooled reactor (MSCR) or a sodium fast reactor (SFR). This transducer is a hollow metallic cylindrical cavity, with one of the flat walls of the cylinder flexible enough to undergo microscopic deflection due to dynamic fluid pressure. Membrane deflection leads to a shift in the microwave resonant frequency, which can be detected with a spectrum analyzer. We have developed a continuum electromechanics model of the microwave resonant cavity transducer performance. The deflection of the membrane is calculated using equations from the theory of plates and shells for deflection of radially constrained thin circular disk under uniform load. The microwave frequency shift is calculated using the equations from the microwave cavity perturbation theory. The transducer model was validated with proof-of-concept experimental data of water flow sensing with a Brass 360 right circular cylinder with 22.2mm diameter and 203µm thick wall. The cavity was excited through a subwavelength hole in TE 011 mode with resonant frequency f ≈ 17.8GHz. Subsequently, we have performed a preliminary proof-of-principle test of flow sensing in high temperature liquid sodium in environment. For this test, we have developed a cylindrical resonator with the same dimensions as for the Brass 360 cavity. The resonator for high temperature liquid sodium test was machined from stainless steel 316 and electroplated with silver on the interior surfaces. We have also developed and insertion probe consisting of a 50cm WR-42 brass waveguide enclosed in a protective SS316 tube. The cavity was excited through a subwavelength hole on the side of the wall of the cylinder in the TE 011 mode with resonant frequency f ≈ 17.8GHz. The liquid sodium setup consists of a cylindrical vessel with a center feed line, where a transducer inserted through the top cap of the vessel measures velocity of the impinging liquid jet. The sodium flow sensing study was performed in a liquid sodium vessel at 340°C temperature and ambient pressure. The flow rate was changed by varying sodium pump power, and a frequency shift of several hundred kHz was observed. The transducer was removed after 70 days of testing. No visual damage was observed, and the electromagnetic response remained the same. As a calibration experiment, we have assembled a water vessel with a center feed, and with dimensions similar to those of the liquid sodium setup. Water flow sensing was performed before and after liquid sodium test. The responses in both cases are similar and agree with COMSOL computer simulations. Because long-term (multi-year) experimental tests of transducer resilience to harsh environment are not practical, we have developed a probabilistic model of creep to estimate transducer resilience to the harsh environment. The probabilistic model considers diffusion creep under the condition of high temperature and low stress, where the stress and temperature are allowed to be random variables with Gaussian distributions. Using the probabilistic model, we estimate inelastic membrane deflections due to creep for several temperature ranges. We conclude that for temperatures less than 650°C, creep has negligible long-term effect on the transducer performance.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Cloud Liquid Water Path Comparisons from Passive Microwave and Solar Reflectance Satellite Measurements: Assessment of Sub-Field-of-View Cloud Effects in Microwave Retrievals

Satellite observations of the cloud liquid water path (LWP) are compared from special sensor microwave imager (SSM/I) measurements and GOES 8 imager solar reflectance (SR) measurements to ascertain the impact of sub-field-of-view (FOV) cloud effects on SSM/I 37 GHz retrievals. The SR retrievals also incorporate estimates of the cloud droplet effective radius derived from the GOES 8 3.9-micron channel. The comparisons consist of simultaneous collocated and full-resolution measurements and are limited to nonprecipitating marine stratocumulus in the eastern Pacific for two days in October 1995. The retrievals from these independent methods are consistent for overcast SSM/I FOVS, with RMS differences as low as 0.030 kg/sq m, although biases exist for clouds with more open spatial structure, where the RMS differences increase to 0.039 kg/sq m. For broken cloudiness within the SSM/I FOV the average beam-filling error (BFE) in the microwave retrievals is found to be about 22% (average cloud amount of 73%). This systematic error is comparable with the average random errors in the microwave retrievals. However, even larger BFEs can be expected for individual FOVs and for regions with less cloudiness. By scaling the microwave retrievals by the cloud amount within the FOV, the systematic BFE can be significantly reduced but with increased RMS differences of O.046-0.058 kg/sq m when compared to the SR retrievals. The beam-filling effects reported here are significant and are expected to impact directly upon studies that use instantaneous SSM/I measurements of cloud LWP, such as cloud classification studies and validation studies involving surface-based or in situ data.

Greenwald, Thomas J.↗

Microwave remote sensing: Active and passive. Volume 1 - Microwave remote sensing fundamentals and radiometry

The three components of microwave remote sensing (sensor-scene interaction, sensor design, and measurement techniques), and the applications to geoscience are examined. The history of active and passive microwave sensing is reviewed, along with fundamental principles of electromagnetic wave propagation, antennas, and microwave interaction with atmospheric constituents. Radiometric concepts are reviewed, particularly for measurement problems for atmospheric and terrestrial sources of natural radiation. Particular attention is given to the emission by atmospheric gases, clouds, and rain as described by the radiative transfer function. Finally, the operation and performance characteristics of radiometer receivers are discussed, particularly for measurement precision, calibration techniques, and imaging considerations.

Ulaby, F. T.↗

Mission Analysis for LEO Microwave Power-Beaming Station in Orbital Launch of Microwave Lightcraft

A detailed mission analysis study has been performed for a 1 km diameter, rechargeable satellite solar power station (SPS) designed to boost 20m diameter, 2400 kg Micr,oWave Lightcraft (MWLC) into low earth orbit (LEO) Positioned in a 476 km daily-repeating oi.bit, the 35 GHz microwave power station is configured like a spinning, thin-film bicycle wheel covered by 30% efficient sola cells on one side and billions of solid state microwave transmitter elements on the other, At the rim of this wheel are two superconducting magnets that can stor,e 2000 G.J of energy from the 320 MW, solar array over a period of several orbits. In preparation for launch, the entire station rotates to coarsely point at the Lightcraft, and then phases up using fine-pointing information sent from a beacon on-board the Lightcraft. Upon demand, the station transmits a 10 gigawatt microwave beam to lift the MWLC from the earth surface into LEO in a flight of several minutes duration. The mission analysis study was comprised of two parts: a) Power station assessment; and b) Analysis of MWLC dynamics during the ascent to orbit including the power-beaming relationships. The power station portion addressed eight critical issues: 1) Drag force vs. station orbital altitude; 2) Solar pressure force on the station; 3) Station orbital lifetime; 4) Feasibility of geo-magnetic re-boost; 5) Beta angle (i..e., sola1 alignment) and power station effective area relationship; 6) Power station percent time in sun vs, mission elapsed time; 7) Station beta angle vs.. charge time; 8) Stresses in station structures.. The launch dynamics portion examined four issues: 1) Ascent mission/trajecto1y profile; 2) MWLC/power-station mission geometry; 3) MWLC thrust angle vs. time; 4) Power station pitch rate during power beaming. Results indicate that approximately 0 58 N of drag force acts upon the station when rotated edge-on to project the minimum frontal area of 5000 sq m. An ion engine or perhaps an electrodynamic thruster (i.e., geomagnetic re-boost) station-keeping system can maintain the orbit altitude. The rate at which the power station s superconducting magnetic energy storage system (SMES) is 'charged' directly relates to the beta angle since the station is operating in the edge-on attitude. The maximum charge rate occurs when the beta angle is at its maximum because time in the sun and projected area of the station are, too, at their maximums For the maximum charge of 2000 G.J with a maximum beta angle of 52 degrees, approximately 3 hours (2 orbital revolutions) are required to reach the full charge, while about 16 hours (10.3 revolutions) are required when the beta angle is 10 degrees. Overall, the LEO station concept appears to be a viable candidate fo1 the formidable power-beaming infrastructure needed to boost MWLC into low earth orbit.

Myrabo, L. N.↗

Incremental Learning for Passive Microwave Precipitation Retrievals using Advanced Technology Microwave Sounder

Spaceborne passive microwave (PMW) radiometry is central to global precipitation monitoring, yet retrieval uncertainties remain substantial, particularly for cross-track sounders whose variable footprints and channel configurations are optimized for atmospheric temperature and moisture profiling rather than precipitation. Consequently, existing operational products often exhibit angular-dependent biases, limited effective swath utilization, unrealistic rainfall probability distributions, and systematic misclassification of precipitation phase. These limitations are further compounded by the scarcity of globally accurate and representative precipitation observations, as training data from the Dual-frequency Precipitation Radar (DPR) and the Cloud Profiling Radar (CPR) are spatially sparse, lack uniform global coverage, and exhibit heterogeneous error characteristics across precipitation regimes. To address these challenges, this study presents a supervised retrieval algorithm that incrementally trains an ensemble of extreme gradient-boosted decision trees by augmenting base learners with pre-training on reanalysis data and post-training on coincident DPR and CPR observations matched with the Advanced Technology Microwave Sounder (ATMS). By transferring prior information from reanalysis to posterior constraints from radar observations and adopting a sequential detection–estimation strategy for precipitation phase and rate retrieval, the proposed approach yields retrievals across the full ATMS swath that are largely free from persistent deficiencies in current Global Precipitation Measurement (GPM) passive microwave operational products. In particular, the method resolves bimodal artifacts in rainfall retrievals and mitigates systematic high-latitude snowfall biases, including overestimation across the Arctic and underestimation across the Antarctic. Validation against independent Multi-Radar Multi-Sensor (MRMS) data over the Contiguous United States (CONUS) further demonstrates improved performance in precipitation phase detection and rate estimation relative to both reanalysis and current GPM PMW products.

Mahyar Garshasbi↗

Microwave radiation hazards around large microwave antenna.

The microwave radiation hazards associated with the use of large antennas become increasingly more dangerous to personnel as the transmitters go to ever higher powers. The near-field area is of the greatest concern. It has spill over from subreflector and reflections from nearby objects. Centimeter waves meeting in phase will reinforce each other and create hot spots of microwave energy. This has been measured in front of and around several 26-meter antennas. Hot spots have been found and are going to be the determining factor in delineating safe areas for personnel to work. Better techniques and instruments to measure these fields are needed for the evaluation of hazard areas.

Klascius, A.↗

Microwave integrated circuit radiometer front-ends for the Push Broom Microwave Radiometer

Microwave integrated circuit front-ends for the L-band, S-band and C-band stepped frequency null-balanced noise-injection Dicke-switched radiometer to be installed in the NASA Langley airborne prototype Push Broom Microwave Radiometer (PBMR) are described. These front-ends were developed for the fixed frequency of 1.413 GHz and the variable frequencies of 1.8-2.8 GHz and 3.8-5.8 GHz. Measurements of the noise temperature of these units were made at 55.8 C, and the results of these tests are given. While the overall performance was reasonable, improvements need to be made in circuit losses and noise temperatures, which in the case of the C-band were from 1000 to 1850 K instead of the 500 K specified. Further development of the prototypes is underway to improve performance and extend the frequency range.

Harrington, R. F.↗

Sea ice effective microwave emissivities from satellite passive microwave and infrared observations

Near-simultaneous images from the temperature-humidity IR radiometer and dual-polarization scanning multichannel microwave radiometer of the Nimbus 7 satellite are used to investigate microwave sea ice emissivities on a global scale. Emissivities in several Arctic region study areas are found to be approximately constant during a nine-month pereiod covering the fall, winter and spring months, in the cases of both first-year and multiyear ice. During the onset of summer, emissivity increases of about 30 percent are observed at 37 GHz in multiyear ice. A multichannel cluster analysis over very large study areas during winter indicates considerable variability in emissivities of consolidated ice clusters at 37 GHz, and only 1/3 as much variability at 18 GHz. If the variability within each cluster is quantified and taken into account by means of multispectral analysis, data on ice thickness and surface characteristics may also be obtained.

Comiso, J. C.↗

Utilization of active microwave roughness measurements to improve passive microwave soil moisture estimates over bare soils

Multisensor aircraft data were used to establish the potential of the active microwave sensor response to be used to compensate for roughness in the passive microwave sensor's response to soil moisture. Only bare fields were used. It is found that the L-band radiometer's capability to estimate soil moisture significantly improves when surface roughness is accounted for with the scatterometers.

Theis, S. W.↗

Utilization of active microwave roughness measurements to improve passive microwave soil moisture estimates over bare soils

Multisensor aircraft data were used to establish the potential of the active microwave sensor response to be used to compensate for roughness in the passive microwave sensor's response to soil moisture. Only bare fields were used. It is found that the L-band radiometer's capability to estimate soil moisture significantly improves when surface roughness is accounted for with the scatterometers.

Theis, S. W.↗

Preliminary separation of galactic and cosmic microwave emission for the COBE Differential Microwave Radiometer

Preliminary models of microwave emission from the Milky Way Galaxy based on COBE and other data are constructed for the purpose of distinguishing cosmic and Galactic signals. Differential Microwave Radiometer (DMR) maps, with the modeled Galactic emission removed, are fitted for a quadrupole distribution. Autocorrelation functions for individual Galactic components are presented. When Galactic emission is removed from the DMR data, the residual fluctuations are virtually unaffected, and therefore they are not dominated by any known Galactic emission component.

Bennet, C. L.↗

Microwave AeroGel Volatile Collector (MAGVC) Aerogel and Microwave Radiation Study

The MAGVC is a volatile extraction system that uses microwave radiation to sublimate and collect water trapped in regolith on the lunar surface It is comprised of: - Microwave source (magnetron) - Aerogel-insulated chamber (depicted as a dome) - Volatile storage system (depicted as 4 tanks) - Autonomous operating system

Aerogel↗