Search NASA⌕ Search

SEARCH · Search NASA

Results for “Missing value replacement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

HDG-1 Experiment Irradiation Monitoring Data Qualification Final Report

SUMMARY The U.S. Department of Energy (DOE) Advanced Reactor Technologies (ART) Graphite Research and Development (GRD) Program is conducting a series of six experiments to quantify the effects of irradiation on nuclear-grade graphite. This report documents the qualification of irradiation monitoring data for the fifth experiment, High Dose Graphite-1 (HDG-1). Qualified monitoring data are required by the ART program to support the design and licensing of the first high-temperature reactor (HTR) nuclear plant. Data are classified as Qualified if they meet the usage requirements described in the experiment planning and quality assurance (QA) documents, Failed if they do not meet those requirements and provide no usable information, or Trend if they do not fully meet all requirements but still provide useful information subject to an assessment of how any deficiencies may affect a particular use of the data. HDG-1 irradiation began with Advanced Test Reactor (ATR) Cycle 168B on August 24, 2020, and concluded after Cycle 173C on January 27, 2025. The HDG-1 capsule was removed from the reactor core twice—during core internal change (CIC) Cycle 170A and powered axial locator mechanism (PALM) Cycle 172A—to prevent overheating of the graphite specimens during high-power PALM cycles. The capsule was therefore irradiated during a total of seven normal ATR cycles: 168B, 169A, 171A, 171B, 173A, 173B, and 173C. Irradiation monitoring data evaluated in this report include thermocouple (TC) temperature, gas flow rate, gas moisture, gas pressure, specimen load, and graphite stack displacement. Temperature. A total of 14,508,065 TC temperature records were captured. Of these, 13,901,785 (95.8%) are Qualified and 606,280 (4.2%) are Failed. The principal source of failed temperature data was the instrument failure of TC-9 (Zone 2) on June 24, 2024, and TC-10 (Zone 1) on July 5, 2024, near the end of Cycle 173A, which resulted in 595,554 Failed readings. An additional 379 missing values and 10,347 slightly negative values from TC-13 during ATR outages are also Failed. Neither TC-9 nor TC-10 was used as a temperature-control TC, and their failures did not compromise capsule condition monitoring. Correlation analysis of all 13 TCs found no evidence of virtual junction formation. Control chart analysis revealed clear downward drift of approximately 80°C for TC-6 (Zone 3) relative to other stable TCs, and possible downward drift of approximately 60°C for TC-13 relative to the Zone 5 control TC (TC-1), though TC-13 remained consistent with the Zone 2 control TC (TC-12). Gas flow. A total of 20,088,090 gas flow rate records were captured. Of these, 19,941,463 (99.3%) are Qualified and 146,627 (0.7%) are Failed due to missing values. All argon, helium, and total gas flow data were within expected ranges throughout the irradiation. Gas moisture. A total of 1,116,005 outlet gas moisture values were captured. Of these, 1,101,421 (98.7%) are Qualified and 14,584 (1.3%) are Failed, comprising 14,556 out-of-range values and 28 missing values. The out-of-range moisture values exceeded 22,000 ppmv for approximately 1 week at the beginning of Cycle 173A, when accumulated moisture evaporated after the capsule was retrieved from water storage during PALM Cycle 172A and reinserted into the east flux trap. Moisture levels returned to below 25 ppmv for the remaining three cycles, and the transient high-moisture event did not affect the integrity of specimen irradiation. Gas pressure. A total of 7,812,035 gas pressure values were captured. Of these, 6,642,048 (85.0%) are Qualified and 1,169,987 (15.0%) outlet pressure values are Failed, comprising 718,537 zero outlet pressure values due to sensor failure from Cycle 168B through Cycle 171B, 54,550 missing values, and 396,900 too-low outlet pressure values, ranging from 1.1 to 1.6 psia after sensor replacement during Cycle 173A. Load. A total of 6,696,030 load values were captured. Of these, 6,694,580 (99.98%) are Qualified and 1,450 (0.02%) are Failed due to missing values. Applied loads to the six specimen stacks were stable throughout the irradiation. Stack displacement. A total of 6,696,030 displacement values were captured. Of these, 5,713,297 (85.32%) are Qualified and 3,781 (0.06%) are Failed due to missing values. Stack displacement increased consistently throughout the irradiation, reaching approximately 3.08 in. for Channels 5 and 6 by the end of irradiation. 978,952 (14.62%) substantially elevated displacements observed for Channel 6 beginning in Cycle 171A and for Channel 5 beginning in Cycle 173A are assigned Trend status. Raising pressure. A total of 1,115,999 raising pressure values were captured. Of these, 1,115,430 (99.95%) are Qualified and 569 (0.05%) are Failed due to missing values. Ram pressure. A total of 6,696,030 ram pressure values were captured. Of these, 6,692,249 (99.95%) are Qualified and 3,484 (0.05%) are Failed due to missing values. Stack raising was perf

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Two dimensional convolute integers for machine vision and image recognition

Machine vision and image recognition require sophisticated image processing prior to the application of Artificial Intelligence. Two Dimensional Convolute Integer Technology is an innovative mathematical approach for addressing machine vision and image recognition. This new technology generates a family of digital operators for addressing optical images and related two dimensional data sets. The operators are regression generated, integer valued, zero phase shifting, convoluting, frequency sensitive, two dimensional low pass, high pass and band pass filters that are mathematically equivalent to surface fitted partial derivatives. These operators are applied non-recursively either as classical convolutions (replacement point values), interstitial point generators (bandwidth broadening or resolution enhancement), or as missing value calculators (compensation for dead array element values). These operators show frequency sensitive feature selection scale invariant properties. Such tasks as boundary/edge enhancement and noise or small size pixel disturbance removal can readily be accomplished. For feature selection tight band pass operators are essential. Results from test cases are given.

Edwards, Thomas R.↗

Electric Field Data from the North Slope of Alaska

File contains raw as well as calibrated electric field values (V/m) from two CS110 electric field meters. The file also contains raw 2-m U and V winds at the same site. The sampling rate is 1Hz. All files contain raw electric field data, as well as calibrated values to a one week ground-based calibration setup. During this week, simultaneous upward-facing ground based electric field measurements were taken alongside the two downward facing instruments on the pole (CS110-3 at 2m and CS110-2 at 5m). Slopes and intercepts were calculated and applied to the values influenced by the pole to convert the raw data to calibrated values. These calibrated values are absolute electric field measurements. There are no missing data codes. The missong data is not included in the files, and thus any files with missing data will be shorter than the normal 86,400 values. In July 2023, the CS110-3 was replaced with an identical instrument named CS110-8, and the CS110-2 was replaced with an identical instrument called CS110-9. All the variable names remained consistent and the same.

54 ENVIRONMENTAL SCIENCES↗

NASA Controller Acceptability Study 1(CAS-1) Experiment Description and Initial Observations

This paper describes the Controller Acceptability Study 1 (CAS-1) experiment that was conducted by NASA Langley Research Center personnel from January through March 2014 and presents partial CAS-1 results. CAS-1 employed 14 air traffic controller volunteers as research subjects to assess the viability of simulated future unmanned aircraft systems (UAS) operating alongside manned aircraft in moderate-density, moderate-complexity Class E airspace. These simulated UAS were equipped with a prototype pilot-in-the-loop (PITL) Detect and Avoid (DAA) system, specifically the Self-Separation (SS) function of such a system based on Stratway+ software to replace the see-and-avoid capabilities of manned aircraft pilots. A quantitative CAS-1 objective was to determine horizontal miss distance (HMD) values for SS encounters that were most acceptable to air traffic controllers, specifically HMD values that were assessed as neither unsafely small nor disruptively large. HMD values between 0.5 and 3.0 nautical miles (nmi) were assessed for a wide array of encounter geometries between UAS and manned aircraft. The paper includes brief introductory material about DAA systems and their SS functions, followed by descriptions of the CAS-1 simulation environment, prototype PITL SS capability, and experiment design, and concludes with presentation and discussion of partial CAS-1 data and results.

Chamberlain, James P.↗

Predicting Missing Regions in Charged Particle Tracks Using a Sparse 3D Convolutional Neural Network

The 2x2 Demonstrator is a prototype detector for the Deep Underground Neutrino Experiment (DUNE)'s Near Detector. Both the 2x2 Demonstrator and the Near Detector itself will have inactive regions wherein there is no sensitivity to charge deposition and light signals that arise from charged particle interactions with liquid argon. In the 2x2, these inactive regions are positioned in-between the active detector modules, which introduces the challenge of inferring what charge signals ought to look like in these regions. This study explores the use of a Sparse 3D Convolutional Neural Network (ConvNet) to infer missing regions in charged particle tracks. Hits corresponding to energy depositions are voxelized into a three-dimensional (3D) grid for each track. Inactive regions within the tracks are replaced with a dense, rectangular 3D grid of voxels, ensuring consistent step sizes in X, Y, and Z directions. Voxels in these dense regions are initialized with an energy value of -1, indicating nonphysical energy or charge. The model is trained to predict which voxels should activate as part of the track and which should not, with the goal of eventually inferring the missing charge or energy values in these voxels. Results indicate that the model accurately predicts track voxels within ±1 unit in X, Y, or Z directions and effectively identifies non-track voxels, despite some overprediction. The approach shows promise in prediction of missing track regions with some accuracy.

43 PARTICLE ACCELERATORS↗

Predicting Missing Regions in Charged Particle Tracks Using a Sparse 3D Convolutional Neural Network

The 2x2 Demonstrator is a prototype detector for the Deep Underground Neutrino Experiment (DUNE)'s Near Detector. Both the 2x2 Demonstrator and the Near Detector itself will have inactive regions wherein there is no sensitivity to charge deposition and light signals that arise from charged particle interactions with liquid argon. In the 2x2, these inactive regions are positioned in-between the active detector modules, which introduces the challenge of inferring what charge signals ought to look like in these regions. This study explores the use of a Sparse 3D Convolutional Neural Network (ConvNet) to infer missing regions in charged particle tracks. Hits corresponding to energy depositions are voxelized into a three-dimensional (3D) grid for each track. Inactive regions within the tracks are replaced with a dense, rectangular 3D grid of voxels, ensuring consistent step sizes in X, Y, and Z directions. Voxels in these dense regions are initialized with an energy value of -1, indicating nonphysical energy or charge. The model is trained to predict which voxels should activate as part of the track and which should not, with the goal of eventually inferring the missing charge or energy values in these voxels. Results indicate that the model accurately predicts track voxels within 1 unit in X, Y, or Z directions and effectively identifies non-track voxels, despite some overprediction. The approach shows promise in prediction of missing track regions with some accuracy.

Utaegbulam, Hilary↗

Direct preemptive stabilization of $m,n$ = 2,1 neoclassical tearing modes by electron cyclotron current drive in the DIII-D low-torque ITER baseline scenario

We report the first preemptive direct stabilization of $m,n$ = 2,1 neoclassical tearing modes (NTMs) in DIII-D low-torque ITER baseline scenario plasmas by electron cyclotron waves. These experiments strongly support that the observed stabilization is achieved by replacing the missing bootstrap current in the island by electron cyclotron current drive (ECCD). These plasmas (with and without ECCD) are stable to 2,1 NTMs when the differential rotation between the q = 1 and q = 2 surfaces (Δf 1,2 ) is sustained above a critical value (Δf CRIT ≈ 1 kHz), but those evolving to low differential rotation (Δf 1,2 < Δf CRIT ) routinely develop a disruptive 2,1 island at the time and frequency of a sawtooth precursor. Preemptive, local and direct stabilization by ECCD is tested by scanning the current drive amplitude and location inside and outside of the q = 2 rational surface shot by shot. Analysis of only low differential rotation time windows, i.e. when stabilization from Δf 1,2 is absent, shows focused ECCD at q = 2 prevents the onset of 2,1 NTMs. These results are important, as they give the first demonstration of disruptive NTM control by ECCD in the plasma scenario planned for ITER.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Mathematical Morphological Filtering with a Self-Adaptive Reconstruction Technique and Application to Local Seismic Data

Recorded seismic data are generally contaminated by noise from different sources, which masks the signals of interest. In the seismology community, frequency filtering (FF) is the standard method for noise suppression. However, when the signal of interest and noise share the same frequency band, the latter cannot be filtered out without infringing on the former. We implemented a noise suppression approach based on the mathematical morphology theorem. The method involves compound operations of dilation and erosion using structuring elements of varying lengths and decomposes an input noisy waveform into several time functions with differing characteristics. Further, the filtered waveform is constructed from the time functions using a self-adaptive reconstruction technique. Application to a data set of >4700 local waveforms suggests that the implemented mathematical morphological filtering (MMF) approach is efficient for data with low signal-to-noise ratio (SNR) and significantly outperforms FF in that SNR range. For most of the dataset, FF, machine learning (ML) denoising, and continuous wavelet transform (CWT) thresholding result in higher SNR values compared with the MMF method. However, for ~42% of the waveforms, MMF outperforms FF, and the SNR gain achieved with MMF is as large as ~23 dB. Compared to ML denoising and CWT thresholding, this proportion drops to only ~10%–14%. Our results suggests that in an operational setting, MMF cannot replace the other noise suppression methods; however, signal detection can be improved if MMF is used to supplement them in some scenarios. MMF could help detect signals in problematic low-SNR data, which are currently being missed particularly when using FF alone.

58 GEOSCIENCES↗

Refinement of the Robert-Bonamy Formalism: Considering Effects from the Line Coupling

Since it was developed in 1979, the Robert-Bonamy (RB) formalism has been widely used in calculating pressure broadened half-widths and induced shifts for many molecular systems. However, this formalism contains several approximations whose applicability has not been thoroughly justified. One of them is that lines of interest are well isolated. When these authors developed the formalism, they have relied on this assumption twice. First, in calculating the spectral density F(ω), they have only considered the diagonal matrix elements of the relaxation operator. Due to this simplification, effects from the line mixing are ignored. Second, when they applied the linked cluster theorem to remove the cutoff, they have assumed the matrix elements of the operator exp(-iS(sub 1) - S(sub 2)) can be replaced by the exponential of the matrix elements of -iS(sub 1) - S(sub 2). With this replacement, effects from the line coupling are also ignored. Although both these two simplifications relied on the same approximation, their validity criteria are completely different and the latter is more stringent than the former. As a result, in many cases where the line mixing becomes negligible, significant effects from the line coupling have been completely missed. In the present study, we have developed a new method to evaluate the matrix elements of exp(-iS(sub 1) - S(sub 2)) and have refined the RB formalism such that line coupling can be taken into account. Our numerical calculations of the half-widths for Raman Q lines of the N(sub 2)-N(sub 2) pair have demonstrated that effects from the line coupling are important. In comparison with values derived from the RB formalism, new calculated values for these lines are significantly reduced. A recent study has shown that in comparison with the measurements and the most accurate close coupling calculations, the RB formalism overestimates the half-widths by a large amount. As a result, the refinement of the RB formalism goes in the right direction and these new calculated half-widths become closer to the "true" values.

spectra↗

Ultraviolet extinction to 10.8 inverse microns

UV extinction curves that represent observed variations i diffuse clouds (Zeta Oph, Xi Per, and Sigma Sco) have been derived by combining IUE and Voyager data and have been modeled by a multicomponent size distribution of silicate and carbonaceous giants. We have used theoretical model atmospheres as our reddening-free standards, and, in the case of Zeta Oph, also compare with the use of a stellar standard. An attempt was made to classify the UV spectra via theoretical spectral indices, but still missing line opacity appears to limit the use of this method at the present. The modeling includes five possible grain ingrediants, largge (0.015-0.25 micrometers) and small (0.005 micrometers) silicate grains, similarly large and small carbonaceous grains, and polycyclic aromatic hydrocarbons (PAHs). The observed extinction curves are fitted by the model via nonlinear Chi-square-minimization, varying the fractional amount of cosmic Si and C that are locked up in each igredient. The observed variation from 'steep' to 'flat' UV extinction curves is found to correspond to a modest model variation in the lower limit of the power-law size distribution of the large grains. Graphite is found to be necessary grain ingredient that cannot be replaced by the laboratory amorphous carbon materials. Carbonaceous mantles on the larger silicate grains provide no good fits to the observed curves. Using absorption properties of neutral laboratory PAHs limits PAHs to a few percent of the cosmic C abundance for acceptable fits that also give values for R(sub V) close to the observed values.

Aannestad, Per A.↗

QA/QC-ed Groundwater Level Time Series in PLM-1 and PLM-6 Monitoring Wells, East River, Colorado (2016-2022)

This data set contains QA/QC-ed (Quality Assurance and Quality Control) water level data for the PLM1 and PLM6 wells. PLM1 and PLM6 are location identifiers used by the Watershed Function SFA project for two groundwater monitoring wells along an elevation gradient located along the lower montane life zone of a hillslope near the Pumphouse location at the East River Watershed, Colorado, USA. These wells are used to monitor subsurface water and carbon inventories and fluxes, and to determine the seasonally dependent flow of groundwater under the PLM hillslope. The downslope flow of groundwater in combination with data on groundwater chemistry (see related references) can be used to estimate rates of solute export from the hillslope to the floodplain and river. QA/QC analysis of measured groundwater levels in monitoring wells PLM-1 and PLM-6 included identification and flagging of duplicated values of timestamps, gap filling of missing timestamps and water levels, removal of abnormal/bad and outliers of measured water levels. The QA/QC analysis also tested the application of different QA/QC methods and the development of regular (5-minute, 1-hour, and 1-day) time series datasets, which can serve as a benchmark for testing other QA/QC techniques, and will be applicable for ecohydrological modeling. The package includes a Readme file, one R code file used to perform QA/QC, a series of 8 data csv files (six QA/QC-ed regular time series datasets of varying intervals (5-min, 1-hr, 1-day) and two files with QA/QC flagging of original data), and three files for the reporting format adoption of this dataset (InstallationMethods, file level metadata (flmd), and data dictionary (dd) files).QA/QC-ed data herein were derived from the original/raw data publication available at Williams et al., 2020 (DOI: 10.15485/1818367). For more information about running R code file (10.15485_1866836_QAQC_PLM1_PLM6.R) to reproduce QA/QC output files, see README (QAQC_PLM_readme.docx). This dataset replaces the previously published raw data time series, and is the final groundwater data product for the PLM wells in the East River. Complete metadata information on the PLM1 and PLM6 wells are available in a related dataset on ESS-DIVE: Varadharajan C, et al (2022). https://doi.org/10.15485/1660962. These data products are part of the Watershed Function Scientific Focus Area collection effort to further scientific understanding of biogeochemical dynamics from genome to watershed scales. 2022/09/09 Update: Converted data files using ESS-DIVE’s Hydrological Monitoring Reporting Format. With the adoption of this reporting format, the addition of three new files (v1_20220909_flmd.csv, V1_20220909_dd.csv, and InstallationMethods.csv) were added. The file-level metadata file (v1_20220909_flmd.csv) contains information specific to the files contained within the dataset. The data dictionary file (v1_20220909_dd.csv) contains definitions of column headers and other terms across the dataset. The installation methods file (InstallationMethods.csv) contains a description of methods associated with installation and deployment at PLM1 and PLM6 wells. Additionally, eight data files were re-formatted to follow the reporting format guidance (er_plm1_waterlevel_2016-2020.csv, er_plm1_waterlevel_1-hour_2016-2020.csv, er_plm1_waterlevel_daily_2016-2020.csv, QA_PLM1_Flagging.csv, er_plm6_waterlevel_2016-2020.csv, er_plm6_waterlevel_1-hour_2016-2020.csv, er_plm6_waterlevel_daily_2016-2020.csv, QA_PLM6_Flagging.csv). The major changes to the data files include the addition of header_rows above the data containing metadata about the particular well, units, and sensor description. 2023/01/18 Update: Dataset updated to include additional QA/QC-ed water level data up until 2022-10-12 for ER-PLM1 and 2022-10-13 for ER-PLM6. Reporting format specific files (v2_20230118_flmd.csv, v2_20230118_dd.csv, v2_20230118_InstallationMethods.csv) were updated to reflect the additional data. R code file (QAQC_PLM1_PLM6.R) was added to replace the previously uploaded HTML files to enable execution of the associated code. R code file (QAQC_PLM1_PLM6.R) and ReadMe file (QAQC_PLM_readme.docx) were revised to clarify where original data was retrieved from and to remove local file paths.

54 ENVIRONMENTAL SCIENCES↗

Demonstration and Evaluation of the Human-Technology Integration Guidance for Plant Modernization

The significance of nuclear power in its role producing carbon-free electricity to the U.S. cannot be overstated. However, with changes in the energy market coupled with changes in incentives given to certain resources like solar and wind, the operating and maintenance costs for these sources have seen a significant reduction, which has consequently negatively impacted the economic viability of the existing U.S. nuclear power plant fleet. Digital instrumentation and control (I&C) and control room modernization is a major critical work domain to reduce operating and maintenance costs. Existing nuclear power plants are commonly configured with mostly legacy analog I&C as well as isolated pockets of digital I&C (a plant process computer, digital recorders, etc.). One challenge with this analog I&C is that replacement parts are becoming prohibitively more expensive and difficult to obtain. Moreover, a significant challenge with the existing analog I&C is that the way in which plants are currently operated and maintained is no longer competitive with other electricity generating sources, like natural gas, where advanced digital I&C technologies are commonplace. This gap between the waynuclear power plants are operated compared to other electricity generating sources significantly challenges the economic viability of the nuclear industry. Indeed, digital I&C systems can fundamentally change the way the plant is operated (i.e., the concept of operation). The introduction of digital I&C technologies offers a wealth of benefits to the nuclear industry. However, it is important to emphasize that, to realize these benefits, a careful understanding of how to integrate technology in a collaborative way that leverages the capabilities of people and technologies is necessary. Human-technology integration applies human factors engineering methods and tools to ensure the safe and reliable use of these technologies while ensuring that the inherent features of the technologies that provide economic value are not missed. The scope of this work documents the demonstration of the recently developed human and technology integration methodology, as applied to developing a new vision and concept of operations for a major U.S. nuclear power plant fleet. This report focuses on the methodological aspects of developing a vision and concept of operations. This report shares the tools, activities, and lessons learned during a modernization currently underway for industry as a whole to consider when planning any significant digital modification and developing a new vision and concept of operations.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

EVA Planning: Using Neutral Buoyancy Laboratory (NBL) Training to Predict in-Flight Energy Expenditure

Metabolic rate (“met rate”) is the amount of energy expended over a period of time and is influenced by many factors including body composition, level of physical activity, resting metabolic rate, sex, age, and food intake. Met rate is measured during Extravehicular Activity (EVA) training at the Neutral Buoyancy Laboratory (NBL) and during in-flight EVAs through indirect calorimetry, calculating energy expenditure from respiratory measurements of O 2 consumption and/or CO 2 production. During Extravehicular Activity (EVA) planning, metabolic cost is important to consider and is used to inform EVA duration based on spacesuit consumables associated with life support systems. Currently, NBL and previous ISS EVA met rate data for specified crewmembers are utilized to predict in-flight EVA metabolic costs based on a proposed EVA timeline. Timeline data collected during training is used to relate met rates to specific EVA activities, which are in turn assigned to more generalized EVA task categories, categorizing by both task type and restraint type. EVA task categories include EVA Setup/Cleanup, Worksite Setup/Cleanup, Cable Routing, Bolts, Fluid Connectors, Electrical Connectors, R&R Work, Miscellaneous Work, Incapacitated Crew Rescue (being rescued or performing), Assisted Crew Rescue (being assisted or performing), and Translation. Restraint types consist of Free-Float, Body Restraint Tether (BRT), Articulating Portable Foot Restraint (APFR), and Space Station Remote Manipulator System (SSRMS). From a crewmember’s historical data, individualized 10th, 50th and 90th percentile met rate estimates are generated for each task category and used to estimate the proposed EVA timeline metabolic cost. In-flight metabolic data (“As-Executed”) from recent ISS US EVAs 85-88 (totaling eight EVA crewmember met rates) was compared with their predicted metabolic cost (“As-Planned”) to evaluate the accuracy of the current met rate estimation method. Across the four EVAs, As-Executed Cumulative EVA Total Metabolic Cost (M = 5893.78 BTU, SD = 816.60) was not significantly different compared to As-Planned Cumulative EVA Total Metabolic Cost (M = 6106.60 BTU, SD = 826.62; t(7) = 0.751 , p = .477). Though not a significant difference, generally, As-Planned total estimates were slightly higher than As-Executed total metabolic cost. Relative Error for Cumulative EVA Total Metabolic Cost ranged from -33% to 14.7%, depending on the crewmember and EVA. When comparing As-Planned to A-Executed EVA task categories for Bolts, Electrical Connectors, EVA Cleanup, EVA Setup, Miscellaneous Work, Translation, Worksite Cleanup, and Worksite Setup during these EVAs, no significant differences were observed, however, there was a significant difference in As-Planned (M = 783.71 BTU, SD = 408.88) compared to As-Executed (M = 608.87 BTU, SD = 425.29) metabolic cost for the task category of Repair-and-Replace (R&R) Work (t(17) = 3.21 , p = .005). Looking closer within the R&R Work task category, As-Executed R&R Work with Free-Float restraint type (M = 706.17 BTU, SD = 352.18) was significantly less than As-Planned R&R Work with Free-Float restraint type (M= 887.96 BTU, SD = 381.42; t(12) = 2.59, p < .024). As-Executed R&R Work with SSRMS Restraint type (M = 355.89 BTU, SD = 534.65) was not significantly different from As-Planned values (M = 512.69 BTU, SD = 383.34; t(4) = 1.88, p = 0.132). These findings suggest that the energy expended performing R&R Work (Free-Float) is lower in flight than predicted. Accurate predictions of the metabolic cost of EVA are essential for planning and executing successful ISS EVAs. Overall, the current met rate prediction method is similar to actual in-flight values, slightly erring on the side of overestimation. Future work includes analysis of more historical in-flight EVA data to increase the power of the analysis, evaluating the NBL-ISS met rate conversion factor between NBL and ISS tasks, as well as exploring methods of substitution when crewmembers are missing prior task category data.

Lauren Cox↗

Dissolved Inorganic Carbon and Dissolved Organic Carbon Data for the East River Watershed, Colorado (2015-2025)

This data package contains mean values for dissolved organic carbon (DOC) and dissolved inorganic carbon (DIC) for water samples taken from the East River Watershed in Colorado. The East River is part of the Watershed Function Scientific Focus Area (WFSFA) located in the Upper Colorado River Basin, United States. DOC and DIC concentrations in water samples were determined using a TOC-VCPH analyzer (Shimadzu Corporation, Japan). DOC was analyzed as non-purgeable organic carbon (NPOC) by purging HCl-acidified samples with carbon-free air to remove DIC prior to measurement. After the acidified sample has been sparged, it is injected into a combustion tube filled with oxidation catalyst heated to 680 oC. The DOC in samples is combusted to CO2 and measured by a non-dispersive infrared (NDIR) detector. The peak area of the analog signal produced by the NDIR detector is proportional to the DOC concentration of the sample. DIC was determined by acidifying the samples with HCl first, and then purging with carbon-free air to release CO2 for analysis by NDIR detector. Total dissolved nitrogen (TDN) was analyzed using a Shimadzu Total Nitrogen Module (TNM-L) combined with the TOC-L analyzer (Shimadzu Corporation, Japan). TNM-L is a non-specific measurement of total nitrogen (TN). All nitrogen species in samples are combusted to nitrogen monoxide and nitrogen dioxide, then reacted with ozone to form an excited state of nitrogen dioxide. Upon returning to ground state, light energy is emitted. Then, TDN is measured using a chemiluminescence detector. All data reported are the mean values upon minimum of three replicate measurements, with a relative standard deviation < 3%. All samples were analyzed under a rigorous quality assurance and quality control (QA/QC) process. This data package contains (1) a zip file (dic_npoc_data_2014-2025.zip) containing a total of 337 files: 336 data files of DIC and NPOC data from across the Lawrence Berkeley National Laboratory (LBNL) Watershed Function Scientific Focus Area (SFA) which is reported in .csv files per location and a locations.csv (1 file) with latitude and longitude for each location; (2) a file-level metadata (v6_20250901_flmd.csv) file that lists each file contained in the dataset with associated metadata; (3) a data dictionary (v6_20250901_dd.csv) file that contains terms/column_headers used throughout the files along with a definition, units, and data type; and (4) PDF and docx files for the determiniation of Method Detection Limits (MDLs) for DIC and NPOC data, which has been updated in 2026-08. Missing values within the anion data files are noted as either "-9999" or "0.0" for not detectable (N.D.) data. There are a total of 113 locations containing DIC/NPOC data. Update on 2020-10-07: Updated the data files to remove times from the timestamps, so that only dates remain. The data values have not changed. Update on 2021-04-11: Added Determination of Method Detection Limits (MDLs) for DIC, NPOC and TDN Analyses document, which can be accessed as a PDF or with Microsoft Word.Update on 6/10/2022: versioned updates to this dataset was made along with these changes: (1) updated dissolved inorganic carbon and dissolved organic carbon data for all locations up to 2021-12-31, (2) removal of units from column headers in datafiles, (3) added row underneath headers to contain units of variables, (4) restructure of units to comply with CSV reporting format requirements, (5) added -9999 for empty numerical cells, and (6) the addition of the file-level metadata (flmd.csv) and data dictionary (dd.csv) were added to comply with the File-Level Metadata Reporting Format. Update on 2022-09-09: Updates were made to reporting format specific files (file-level metadata and data dictionary) to correct swapped file names, add additional details on metadata descriptions on both files, add a header_row column to enable parsing, and add version number and date to file names (v2_20220909_flmd.csv and v2_20220909_dd.csv). Update on 2023-08-08: Updates were made to both the data files and reporting format specific files. New available anion data was added, up until 2023-01-05. The file level metadata and data dictionary files were updated to reflect the additional data added. Update on 2024-03-11: Updates were made to both the data files and reporting format specific files. New available anion data was added, up until 2023-11-21. Further, revisions to the data files were made to remove incorrect data points (from 1970 and 2001). The reporting format specific files were updated to reflect the additional data added. Revised versions of the PDF and docx files for determination of MDLs for DIC and NPOC were added to replace previous versions. Update on 2025-05-15: Updates were made to both the data files and reporting format specific files. New available DIC and NPOC data was added, up until the end of WY2024 (September 30, 2024). International Generic Sample Numbers (IGSNs), when registered, were added to the data files. The reporting format specific files were updated to reflect the additional data added. Update on 2026-09-01: Updates were made to both the data files and reporting format specific files. New available DIC and NPOC data was added, up until the end of WY2025 (September 30, 2025). Updated versions, as of 2026-08-10, of the PDF and docx files for determination of MDLs for DIC and NPOC data were added to this dataset.

54 ENVIRONMENTAL SCIENCES↗

Total Dissolved Nitrogen and Ammonia Data for the East River Watershed, Colorado (2015-2025)

This data package contains mean values for total dissolved nitrogen (TDN) and ammonia concentrations for water samples taken from the East River Watershed in Colorado. The East River is part of the Watershed Function Scientific Focus Area (WFSFA) located in the Upper Colorado River Basin, United States. TDN was analyzed using a Shimadzu Total Nitrogen Module (TNM-1) combined with the TOC-VCSH analyzer (Shimadzu Corporation, Japan). TNM-1 is a non-specific measurement of total nitrogen (TN). All nitrogen species in samples are combusted to nitrogen monoxide and nitrogen dioxide, then reacted with ozone to form an excited state of nitrogen dioxide. Upon returning to ground state, light energy is emitted. Then, TDN is measured using a chemiluminescence detector. Ammonia was determined using a Lachat's QuikChem 8500 Series 2 Flow Injection Analysis System (LACHAT Instruments, QuckChem 8500 series 2, Automated Ion Analyzer, Loveland, Colorado). When ammonia in water samples is heated (60 degrees C) with salicylate and hypochlorite in an alkaline phosphate buffer, an emerald green color is produced which is proportional to the ammonia concentration. The color is intensified by the addition of nitroprusside. Ethylenediaminetetraacetic acid (EDTA) is added to the buffer to prevent the interference of metal ions (Ca, Mg, and Fe etc.). Ammonia-N is then determined by LACHAT flow injection and a colorimetric assay at an absorbance wavelength 660 nm. (Reference: LACHAT Instruments: QuickChem Method 90-107-06-3-A, Determination of Ammonia by Flow Injection Analysis (High Throughput, Salicylate Method/DCIC) (Multi Matrix method). Written by Lynn Egan (Application group), February 08, 2011.) All files are labeled by location and variable, and data reported are the mean values upon replicate measurements. All samples were analyzed under a rigorous quality assurance and quality control (QA/QC) process as detailed in the methods. This data package contains (1) a zip file (tdn_ammonia_data_2015-2025.zip) containing a total of 299 files: 298 data files of ammonia and TDN data from across the Lawrence Berkeley National Laboratory (LBNL) Watershed Function Scientific Focus Area (SFA) which is reported in .csv files per location and a locations.csv (1 file) with latitude and longitude for each location; (2) a file-level metadata (v7_20260901_flmd.csv) file that lists each file contained in the dataset with associated metadata; (3) a data dictionary (v7_20260901_dd.csv) file that contains terms/column_headers used throughout the files along with a definition, units, and data type; (4) PDF and docx files for the determination of Method Detection Limits (MDLs) for TDN data, which has been updated in 2026-08; and (5) PDF and docx files for the detemination of Method Detection Limits (MDLs) for Ammonia and the Interferences by LACHAT Flow Injection Analysis. Missing values within the anion data files are noted as either "-9999" or "0.0" for not detectable (N.D.) data. There are a total of 105 locations containing TDN and Ammonia-N data. Update 2020-10-07: Updated the data files to remove times from the timestamps, so that only dates remain. The data values have not changed. Update 2021-04-11: Added Determination of Method Detection Limits (MDLs) for DIC, NPOC and TDN Analyses and Determination of Method Detection Limit for Ammonia and the Interferences by LACHAT Flow Injection Analysis documents, which can be accessed as PDFs or with Microsoft Word.Update on 6/10/2022: versioned updates to this dataset was made along with these changes: (1) updated total dissolved nitrogen and ammonia data for all locations up to 2021-12-31, (2) removal of units from column headers in datafiles, (3) added row underneath headers to contain units of variables, (4) restructure of units to comply with CSV reporting format requirements, (5) added -9999 for empty numerical cells, and (6) the addition of the file-level metadata (flmd.csv) and data dictionary (dd.csv) were added to comply with the File-Level Metadata Reporting Format. Update on 2022-09-09: Updates were made to reporting format specific files (file-level metadata and data dictionary) to correct swapped file names, add additional details on metadata descriptions on both files, add a header_row column to enable parsing, and add version number and date to file names (v2_20220909_flmd.csv and v2_20220909_dd.csv). Update on 2022-12-20: Updates were made to both the data files and reporting format specific files. Units were listed incorrectly, but have been fixed to reflect correct units (ug/L). File level metadata (flmd) and data dictionary (dd) files were updated to reflect the updated versions of these files. Available data was added up until 2022-06-01. Update on 2023-08-08: Updates were made to both the data files and reporting format specific files. New available anion data was added, up until 2023-01-05. The file level metadata and data dictionary files were updated to reflect the additional data added. Update on 2024-03-11: Updates were made to both the data files and reporting format specific files. New available anion data was added, up until 2023-10-27. Further, revisions to the data files were made to remove incorrect data points (from 1970 and 2001). The reporting format specific files were updated to reflect the additional data added. Revised versions of the PDF and docx files for determination of MDLs for TDN were added to replace previous versions. Update on 2025-05-15: Updates were made to both the data files and reporting format specific files. New available TDN and Ammonia-N data was added, up until the end of WY2024 (September 30, 2024). International Generic Sample Numbers (IGSNs), when registered, were added to the data files. The reporting format specific files were updated to reflect the additional data added. Update on 2026-09-01: Updates were made to both the data files and reporting format specific files. New available TDN and Ammonia-N data was added, up until the end of WY2025 (September 30, 2025). Updated versions, as of 2026-08-10, of the PDF and docx files for determination of MDLs for TDN data were added to this dataset.

54 ENVIRONMENTAL SCIENCES↗