Segmentation and tracking in echocardiographic sequences: active contours guided by optical flow estimates

This paper presents a method for segmentation and tracking of cardiac structures in ultrasound image sequences. The developed algorithm is based on the active contour framework. This approach requires initial placement of the contour close to the desired position in the image, usually an object outline. Best contour shape and position are then calculated, assuming that at this configuration a global energy function, associated with a contour, attains its minimum. Active contours can be used for tracking by selecting a solution from a previous frame as an initial position in a present frame. Such an approach, however, fails for large displacements of the object of interest. This paper presents a technique that incorporates the information on pixel velocities (optical flow) into the estimate of initial contour to enable tracking of fast-moving objects. The algorithm was tested on several ultrasound image sequences, each covering one complete cardiac cycle. The contour successfully tracked boundaries of mitral valve leaflets, aortic root and endocardial borders of the left ventricle. The algorithm-generated outlines were compared against manual tracings by expert physicians. The automated method resulted in contours that were within the boundaries of intraobserver variability.

Non-NASA Center↗

Fast interactive real-time volume rendering of real-time three-dimensional echocardiography: an implementation for low-end computers

Real-time three-dimensional echocardiography (RT3DE) is an innovative cardiac imaging modality. However, partly due to lack of user-friendly software, RT3DE has not been widely accepted as a clinical tool. The object of this study was to develop and implement a fast and interactive volume renderer of RT3DE datasets designed for a clinical environment where speed and simplicity are not secondary to accuracy. Thirty-six patients (20 regurgitation, 8 normal, 8 cardiomyopathy) were imaged using RT3DE. Using our newly developed software, all 3D data sets were rendered in real-time throughout the cardiac cycle and assessment of cardiac function and pathology was performed for each case. The real-time interactive volume visualization system is user friendly and instantly provides consistent and reliable 3D images without expensive workstations or dedicated hardware. We believe that this novel tool can be used clinically for dynamic visualization of cardiac anatomy.

NASA Discipline Cardiopulmonary↗

Automated assessment of noninvasive filling pressure using color Doppler M-mode echocardiography

Assessment of left ventricular filling pressure usually requires invasive hemodynamic monitoring to follow the progression of disease or the response to therapy. Previous investigations have shown accurate estimation of wedge pressure using noninvasive Doppler information obtained from the ratio of the wave propagation slope from color M-mode (CMM) images and the peak early diastolic filling velocity from transmitral Doppler images. This study reports an automated algorithm that derives an estimate of wedge pressure based on the spatiotemporal velocity distribution available from digital CMM Doppler images of LV filling.

Non-NASA Center↗

Pulmonary venous flows reflect changes in left atrial hemodynamics during mitral balloon valvotomy

Patients with mitral stenosis have usually blunted pulmonary venous (PV) flow, because of decreased mitral valve area and diastolic dysfunction. The authors compared changes in Doppler PV velocities by using transesophageal echocardiography (TEE) against hemodynamics parameters before and after mitral balloon valvotomy to observe relevance of PV velocities and endsystolic left atrial (LA) pressure-volume relationship. In 25 patients (aged 35 +/- 17 years) with mitral stenosis in sinus rhythm, changes in LA pressure and volumes were compared with PV velocities before and after valvotomy. Mitral valve area, mitral gradients, and deceleration time were obtained. Mitral valve area and mitral gradients changed from 1 +/- 0.2 cm2 and 14.6 +/- 5.4 mmHg to 1.9 +/- 0.3 cm2 and 6.3 +/- 1.7 mmHg, respectively (p<0.001). AR peak reverse flow velocity and AR duration decreased from 29 +/- 13 cm/s and 110 =/- 30 msec to 19 +/- 6 cm/s and 80 +/- 29 msec respectively (p<0.001). Transmitral Doppler E wave deceleration time decreased from 327 +/- 85 to 209 +/- 61 s and cardiac output increased from 4.2 +/- 1.0 to 5.2 +/- 1.1 L/minute (p<0.001). The changes in LA pressure were correlated with changes in S/D (r=0.57, p<0.05). The changes in endsystolic LA pressure-volume relationship were also correlated with changes in S/D (r=0.52, p<0.05). Endsystolic LA pressure-volume relationship decreased after mitral balloon valvotomy, as a result of a large decrease in pressure. PV systolic/diastolic (S/D) waves ratio reflects endsystolic LA pressure-volume relationship and may be used as another indicator of successful valvotomy.

Non-NASA Center↗

Application of color Doppler flow mapping to calculate orifice area of St Jude mitral valve

BACKGROUND: The effective orifice area (EOA) of a prosthetic valve is superior to transvalvular gradients as a measure of valve function, but measurement of mitral prosthesis EOA has not been reliable. METHODS AND RESULTS: In vitro flow across St Jude valves was calculated by hemispheric proximal isovelocity surface area (PISA) and segment-of-spheroid (SOS) methods. For steady and pulsatile conditions, PISA and SOS flows correlated with true flow, but SOS and not PISA underestimated flow. These principles were then used intraoperatively to calculate cardiac output and EOA of newly implanted St Jude mitral valves in 36 patients. Cardiac output by PISA agreed closely with thermodilution (r=0.91, Delta=-0.05+/-0.55 L/min), but SOS underestimated it (r=0.82, Delta=-1.33+/-0.73 L/min). Doppler EOAs correlated with Gorlin equation estimates (r=0.75 for PISA and r=0.68 for SOS, P<0.001) but were smaller than corresponding in vitro EOA estimates. CONCLUSIONS: Proximal flow convergence methods can calculate forward flow and estimate EOA of St Jude mitral valves, which may improve noninvasive assessment of prosthetic mitral valve obstruction.

NASA Discipline Cardiopulmonary↗

Quantification of mitral regurgitation by automated cardiac output measurement: experimental and clinical validation

OBJECTIVES: To develop and validate an automated noninvasive method to quantify mitral regurgitation. BACKGROUND: Automated cardiac output measurement (ACM), which integrates digital color Doppler velocities in space and in time, has been validated for the left ventricular (LV) outflow tract but has not been tested for the LV inflow tract or to assess mitral regurgitation (MR). METHODS: First, to validate ACM against a gold standard (ultrasonic flow meter), 8 dogs were studied at 40 different stages of cardiac output (CO). Second, to compare ACM to the LV outflow (ACMa) and inflow (ACMm) tracts, 50 normal volunteers without MR or aortic regurgitation (44+/-5 years, 31 male) were studied. Third, to compare ACM with the standard pulsed Doppler-two-dimensional echocardiographic (PD-2D) method for quantification of MR, 51 patients (61+/-14 years, 30 male) with MR were studied. RESULTS: In the canine studies, CO by ACM (1.32+/-0.3 liter/min, y) and flow meter (1.35+/-0.3 liter/min, x) showed good correlation (r=0.95, y=0.89x+0.11) and agreement (deltaCO(y-x)=0.03+/-0.08 [mean+/-SD] liter/min). In the normal subjects, CO measured by ACMm agreed with CO by ACMa (r=0.90, p < 0.0001, deltaCO=-0.09+/-0.42 liter/min), PD (r=0.87, p < 0.0001, deltaCO=0.12+/-0.49 liter/min) and 2D (r=0.84, p < 0.0001, deltaCO=-0.16+/-0.48 liter/min). In the patients, mitral regurgitant volume (MRV) by ACMm-ACMa agreed with PD-2D (r= 0.88, y=0.88x+6.6, p < 0.0001, deltaMRV=2.68+/-9.7 ml). CONCLUSIONS: We determined that ACM is a feasible new method for quantifying LV outflow and inflow volume to measure MRV and that ACM automatically performs calculations that are equivalent to more time-consuming Doppler and 2D measurements. Additionally, ACM should improve MR quantification in routine clinical practice.

Non-NASA Center↗