Search NASA⌕ Search

SEARCH · Search NASA

Results for “Mixer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Comparison of nanocomposite dispersion and distribution for several melt mixers

Breakup (dispersion) and distribution of nanoparticles are the chief hurdles towards taking advantage of nanoparticles in polymer nanocomposites for reinforcement, flame retardancy, conductivity, chromaticity, and other properties. Microscopy is often used to quantify mixing, but it has a limited field of view, does not average over bulk samples, and fails to address nano-particle hierarchical structures. Ultra-small-angle X-ray scattering (USAXS) can provide a macroscopic statistical average of nanoscale dispersion (breakup) and emergent hierarchical structure, as well as the distribution on the nanoscale. Here, this work compares several common mixer geometries for carbon black-polystyrene nanocomposites. Two twin-screw extruder geometries, typical for industrial processing of melt blends, are compared with a laboratory-scale single screw extruder and a Banbury mixer. It is found that for a given mixer, nanoscale distribution increases following a van der Waals function using accumulated strain as an analogue for temperature while macroscopic distribution/dispersion, using microscopy, does not follow this dependency. Breakup and aggregation in dispersive mixing follow expected behavior on the nanoscale. Across these drastically different mixing geometries an unexpected dependency is observed for nanoscale distributive mixing (both nano and macroscopic) as a function of accumulated strain that may reflect a transition from distributive turbulent to dispersive laminar mixing as the mixing gap is reduced.

36 MATERIALS SCIENCE↗

Infrared compatible rapid mixer to probe millisecond chemical kinetics

Fast microfluidic mixers are a valuable tool for studying solution-phase chemical reaction kinetics and molecular processes with spectroscopy. However, microfluidic mixers that are compatible with infrared vibrational spectroscopy have seen only limited development due to the poor infrared transparency of the current microfabrication material. We describe the design, fabrication, and characterization of CaF2-based continuous flow turbulent mixers, which are capable of measuring kinetics in the millisecond time window with infrared spectroscopy, when integrated into an infrared microscope. Kinetics measurements demonstrate the ability to resolve relaxation processes with 1 millisecond time resolution, and straightforward improvements are described that should result in sub-100 µs time-resolution.

Instruments & Instrumentation↗

Millisecond timescale reactions observed via X-ray spectroscopy in a 3D microfabricated fused silica mixer

Determination of electronic structures during chemical reactions remains challenging in studies which involve reactions in the millisecond timescale, toxic chemicals, and/or anaerobic conditions. Here, a three-dimensionally (3D) microfabricated microfluidic mixer platform that is compatible with time-resolved X-ray absorption and emission spectroscopy (XAS and XES, respectively) is presented. This platform, to initiate reactions and study their progression, mixes a high flow rate (0.50–1.5 ml min –1 ) sheath stream with a low-flow-rate (5–90 µl min –1 ) sample stream within a monolithic fused silica chip. The chip geometry enables hydro­dynamic focusing of the sample stream in 3D and sample widths as small as 5 µm. The chip is also connected to a polyimide capillary downstream to enable sample stream deceleration, expansion, and X-ray detection. In this capillary, sample widths of 50 µm are demonstrated. Further, convection–diffusion-reaction models of the mixer are presented. The models are experimentally validated using confocal epifluorescence microscopy and XAS/XES measurements of a ferricyanide and ascorbic acid reaction. The models additionally enable prediction of the residence time and residence time uncertainty of reactive species as well as mixing times. Residence times (from initiation of mixing to the point of X-ray detection) during sample stream expansion as small as 2.1 ± 0.3 ms are also demonstrated. Importantly, an exploration of the mixer operational space reveals a theoretical minimum mixing time of 0.91 ms. The proposed platform is applicable to the determination of the electronic structure of conventionally inaccessible reaction intermediates.

3D microfabrication↗

Effects of gamma, electron beam, and X-ray irradiation on the plastic components of a universal bone cement mixer medical device

Due to market and regulatory pressures, many healthcare manufacturers are considering alternatives to cobalt-60 gamma radiation, including accelerator-based electron beam (E-beam) and X-ray radiation for product sterilization. In this work, the effects of irradiation on a representative medical product, comprised of eight distinct polymer materials, were directly compared for three radiation technologies – cobalt-60 gamma, E-beam, and X-ray – at four dose levels (15, 25, 50, and 70 kGy). The objective was to determine how radiation effects (deleterious or beneficial) are influenced by source and dose level, with the specific goal of determining whether E-beam radiation and/or X-ray radiation could be viable alternatives to gamma radiation for device sterilization. Here, the specific product considered is a single-use medical device for orthopedic surgery, the Stryker Instruments MixeVac III bone cement mixer, which is currently sterilized using gamma radiation from cobalt-60 sources. Following ASTM International standards and input from the manufacturer, we characterized the effects of the three radiation sources on product functionality as well as on the mechanical and optical properties of the constituent polymers. Results indicate that although measurable differences in properties between the standard gamma irradiated materials and the alternative E-beam and X-ray irradiated materials were observed, those differences were small. Statistically significant differences were noted in the case of yellowness index for polyvinyl chloride, high-density polyethylene, and polycarbonate, and in the case of tensile elongation at break for high impact polystyrene and polyvinyl chloride. In general, the results of this study support the viability of E-beam and X-ray radiation as alternative options to cobalt-60 gamma radiation for sterilization of Stryker single-use universal bone cement mixer medical devices.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fast jet tagging with MLP-Mixers on FPGAs

We explore the innovative use of MLP-Mixer models for real-time jet tagging and establish their feasibility on resource-constrained hardware like FPGAs. MLP-Mixers excel in processing sequences of jet constituents, achieving state-of-the-art performance on datasets mimicking Large Hadron Collider conditions. By using advanced optimization techniques such as High-Granularity Quantization and Distributed Arithmetic, we achieve unprecedented efficiency. These models match or surpass the accuracy of previous architectures, reduce hardware resource usage by up to 97%, double the throughput, and half the latency. Additionally, non-permutation-invariant architectures enable smart feature prioritization and efficient FPGA deployment, setting a new benchmark for machine learning in real-time data processing at particle colliders.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fuel injector including a lobed mixer and vanes for injecting alternate fuels in a gas turbine

A fuel injector for injecting alternate fuels having a different energy density in a gas turbine is provided. A first fuel supply channel (18) may be fluidly coupled to a radial passage (22) in a plurality of vanes (20) that branches into passages (24) (e.g., axial passages) to inject a first fuel without jet in cross-flow injection. This may be effective to reduce flashback in fuels having a relatively high flame speed. A mixer (30) with lobes (32) for injection of a second fuel may be arranged at the downstream end of a fuel delivery tube (12). A fuel-routing structure (38) may be configured to route the second fuel within a respective lobe so that fuel injection of the second fuel takes place radially outwardly relative to a central region of the mixer. This may be conducive to an improved (e.g., a relatively more uniform) mixing of air and fuel.

42 ENGINEERING↗

Replaceable Paddle Tip Fabrication and Testing for Saltstone Production Facility (SPF) Mixer (FY2020 Update)

Details of the operations and issues related to the paddles used in the Saltstone Production Facility (SPF) employing the 10-inch READCO ™ -Kurimoto co-rotating dual shaft continuous mixer are provided in SRNL-ST1-2019-00142, Based on a recent effort performed by the Savannah River National Laboratory (SRNL) and funded by Savannah River Remediation (SRR), eight different replaceable paddle designs were proposed and the angled notched design was selected for this study. This design was selected over the other designs due to its simplicity and its ability to meet the fitness of duty requirements. There are two types of angled notched replaceable tip designs, one being flat and the other helical. Either of these designs can be used for blending the premix with the salt solution. Stress calculations performed on this design (the use of the bolts and connections) are documented in M-CLC-Z-00137 showing it was suitable for use.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Utilizing Commercial Submersible Mixer Pumps for Sludge Removal in Savannah River Site's Tank 26 - 20289

The Savannah River Site (SRS) Liquid Waste System (LWS) safely manages, stores, treats, and dispositions liquid radioactive waste. The LWS consists of 51 underground waste storage tanks (eight of which are operationally closed and filled with grout), waste evaporators, treatment facilities, and solidification facilities, known as the Defense Waste Processing Facility (DWPF) and Saltstone Production Facility (SPF). One of the waste storage tanks, Tank 26, was placed into service in 1980 as an F Tank Farm (FTF) Evaporator Feed Tank. From 1980 to 2013, Tank 26 received F Canyon receipts and dilute supernate that was then transferred to the 242-16F FTF Evaporator for volume reduction. In 2013, the steam tube bundle failed in the FTF Evaporator, and the decision was made not to repair/resume evaporator operation. During operation of Tank 26, solids built up to a level of 2.03 m in the tank with a volume of 1062.9 kL. Due to the evaporator failure and subsequent shutdown, the solids in Tank 26 were selected to feed Sludge Batch 10, which is collected and prepped prior to being sent to DWPF for final disposition. To accomplish solids removal, Commercial Submersible Mixer Pumps (CSMPs) were selected to slurry the solids in preparation to be sent to Tank 51. Four CSMPs were installed in Tank 26 with each one installed in a separate quadrant of Tank 26. This work would mark the first deployment of CSMPs in an SRS waste tank. The CSMPs were developed in response to operational issues from previous mixing pumps and budgetary constraints. The CSMPs use the concept of modifying commercially available equipment for nuclear waste applications. The CSMPs consist of a 230-horsepower submersible mixing pump (manufactured by GPM, Inc.) joined to a mast fabricated at SRS. For this application, Savannah River Remediation (SRR) design services was challenged to provide a mast design that required no steel superstructure support system on top of Tank 26. Also, SRR design services provided a simplified Tank 26 riser interface that did not require extensive machine parts to adjust height of the suction screen of the CSMP within the tank. Other design improvements include no requirements for tank top radiation monitors and no requirements for flushing of the CSMPs during startup/shutdown operations. The CSMPs were operated at an initial height of 2.29 m above the Tank 26 bottom for 10 days. After sludge sounding, the CSMPs were lowered to a height of 1.52 m with no issues due to proper work planning and the simplified riser interface. With the CSMPs lowered to a level of 1.52 meters above the tank bottom, the CSMPs were operated for 12 days and another sounding was performed. The sounding level came back matching the disturbance depth results of the first pump run. Chemistry samples were analyzed while the tank was left to settle. The analysis revealed enough weight percent solids to provide good feed to Sludge Batch 10. Also, the results revealed the supernate within the mixture would provide good salt solution feed to Salt Waste Processing Facility (SWPF) Salt Batch 3. So, the plan was modified to let the disturbed solids settle and decant the salt solution for addition to SWPF Salt Batch 3. Then water will be added back to Tank 26, and the CSMPs run in order to wash the solids to decrease settling time prior to being sent to Tank 51 for Sludge Batch 10. Utilizing CSMPs for waste removal in an SRS Tank has provided a cost-effective means for further waste removal efforts. In addition, the CSMPs are easier to operate by utilizing a robust and simplified design. The CSMPs performed quite well with no process shutdown or delays during operation. As a result, CSMPs are integral to the future of removing radioactive waste from storage tanks at SRS. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

In‐situ Analysis of Paste Properties in Resonant Acoustic Mixers for Quality Monitoring

Formulation control is key to achieving consistent target properties of energetic materials, as feedstock variations and slight deviations in the ratios of different ingredients can have major effects on final product properties, particularly in dense pastes with high particle loading >65 vol.%. In large‐scale operations, it is imperative to either correct or remove batches of material that perform outside baseline property specifications as early as possible to avoid unnecessary processing of suboptimal material. Quality monitoring is the practice of measuring material properties during processing using process analytical technologies as opposed to only testing the properties of the final product; it is a key principle in the quality‐by‐design frameworks used for designing formulations and manufacturing processes. Herein, a process analytical technology method for correlating material properties of dense pastes directly after mixing in a Resonant Acoustic Mixer to motor data is developed and used to detect differences in the particle content of dense paste formulations. This method was also capable of detecting variations in powder feedstock properties, such as particle packing efficiency, and is sensitive enough to detect changes of 2 wt.% in the total solids content of the formulation. The techniques presented herein show excellent promise for use as a process analytical technology capable of quantifying formulation effects on material movement modes during resonant acoustic mixing.

Materials science↗

On the competition between mixing rate and uniformity in a coaxial hydrodynamic focusing mixer

Fast microfluidic mixers for use with line-of-sight integrating detection schemes pose unique challenges. Such detectors typically cannot discriminate signal from slow moving (e.g. near internal walls) and fast-moving portions of the fluid stream. This convolves reaction rate dynamics with fluid flow residence time dynamics. Further, the small cross sections of typical three-dimensional hydrodynamic focusing devices lead to lower detection signals. The current study focuses on achieving both small time scales of mixing and homogenous residence times. This is achieved by injecting sample through a center capillary and hydrodynamically focusing using a sheath flow within a tapered second capillary. The current design also features a third, larger coaxial capillary. The mixed stream flows into the large cross-section of this third capillary to decelerate and expand the stream by up to 14-fold to improve line-of-sight signal strength of reaction products. Hydrodynamic focusing, mixing, and expansion are studied using analytical and numerical models and also studied experimentally using a fluorescein-iodide quenching reaction. The experimentally validated models are used to explore trade-offs between mixing rate and uniformity. For the first time, this work presents detailed analysis of the Lagrangian time history of species transport during mixing inside coaxial capillaries to measure mixing nonuniformity. The mixing region enables order 100 μs mixing times and residence time widths of the same order (140 μs).

42 ENGINEERING↗

Gamma, electron beam and X-ray irradiation effects on polymers in an advanced bone cement mixer device

The medical device industry has been investigating ways to increase the use of alternatives to cobalt-60 gamma radiation and ethylene-oxide gas sterilization, such as electron beam (E-beam) and X-ray radiation, due to regulatory and market pressures. One impediment to switching to E-beam or X-ray technology for sterilization is the lack of data on the effects of these radiation sources on medical device polymers. To provide such data this work considers irradiation and testing of a common single-use medical bone cement mixing system, the Stryker Advanced Cement Mixer (ACM®), that is composed of seven polymer materials. The ACM® devices considered here were processed to sterilization-relevant doses (15, 25, 50, and 70 kGy) using three radiation technologies: gamma, E-beam, and X-ray. The system and its polymer components were tested for product functionality, as well as mechanical and visual properties to determine how exposure effects may be influenced by radiation technology and dose level. We found that although there were instances of statistically significant differences in effects between the gamma-irradiated products and those irradiated with E-beam and X-ray, those effects were negligible in terms of retained functionality of the product and retained mechanical properties of the polymer components. Overall, results of this study demonstrate that, for of the effects studied, E-beam and X-ray are viable alternatives to cobalt-60 gamma radiation for sterilization of the polymer-based device investigated.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Freedom of the mixer rotation axis improves performance in the quantum approximate optimization algorithm

Variational quantum algorithms such as the quantum approximate optimization algorithm (QAOA) are particularly attractive candidates for implementation on near-term quantum processors. As hardware realities such as error and qubit connectivity will constrain achievable circuit depth in the near future, new ways to achieve high performance at low depth are of great interest. In this work, we present a modification to QAOA that adds additional variational parameters in the form of freedom of the rotation axis in the XY plane of the mixer Hamiltonian. Here, via numerical simulation, we show that this leads to a drastic performance improvement over standard QAOA at finding solutions to the MaxCut problem on graphs of up to seven qubits. Furthermore, we explore the Z-phase error mitigation properties of our modified Ansatz, its performance under a realistic error model for a neutral atom quantum processor, and the class of problems it can solve in a single round.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Advanced Multi-Tube Mixer Combustion for 65% Efficiency (Final Report)

This project targeted advanced low NOx combustion for advanced gas turbines capable of 65%, or greater, efficiency in combined cycle application. This technology advancement has further potential to benefit gas turbines used in coal based IGCC applications with pre-combustion carbon capture and hydrogen as the resulting fuel. The program developed and synthesized the most advanced combustion system capable of achieving low NOX emissions up to turbine inlet temperatures of 3100F while also supporting the load-following needs of a modern grid. The combustion system contributes to the overall gas turbine efficiency goal by setting the maximum cycle temperature achievable for a given NOX level and by minimizing the through-combustor air flow pressure drop. Focus areas for this project targeted maximizing the turbine inlet temperature entitlement, as constrained by emissions considerations. The design also minimized parasitic air flow pressure drop by using advanced cooling techniques and performance materials selections and by minimizing hot surface area. These two technology objectives (maximum, emissions-compliant cycle temperature and minimum air flow pressure drop) were integrated into a prototype design. The primarily analytical project sought to identify the most promising technologies to meet these objectives. Additional critical “jugular” data were obtained from multi-tube mixer tests to realize the potential of leveraging “micro flames” for minimizing overall hot surface area. This data was used, in conjunction with an understanding of advanced material and cooling design technologies, to analytically develop multiple design concepts. Phase I focused on in-depth engineering analysis and design, with minimal supporting laboratory testing to enable a selection of the top three combustion architectures for achieving these overall objectives. Phase II of the program developed the selected design through a combination of sub-scale testing and analytical efforts. Early tests included a cold-flow cascade to establish aerodynamic performance characteristics and a sub-scale fired test at GE Global Research in Niskayuna, NY, to establish cooling and heat transfer characteristics in conjunction with combustion performance. The data from these tests validated the analytical models to ultimately design a full-scale, test article to evaluate at prototypical pressure and temperature conditions at GE Gas Power’s Gas Turbine Technology Laboratory in Greenville, SC. GE Gas Power also developed, tested, and recommended a suitable seal design to be applied to the unique features of the combustor. To assess the technology challenges from prospective future production of the combustor from a ceramic matrix composite material, screening tests of Environmental Barrier Coatings were completed.

20 FOSSIL-FUELED POWER PLANTS↗

Method and system for microwave mixer phase response measurement

A system, method and apparatus for mixer phase response measurement comprises a vector network analyzer connectable to a device under test, an additional device connected to the analyzer the additional device configured to have an equal phase response to that of the device under test, a local oscillator connected to the device under test and the additional device, a series of switches connecting the device under test and the additional device to a vector voltmeter, and a reference generator connected to the vector voltmeter.

Frolov, Daniil↗

Main mixer in an axial staged combustor for a gas turbine engine

A main mixer including a swirler along an axis, the swirler including an outer swirler with a multiple of outer vanes, and a center swirler with a multiple of center vanes and a swirler hub along the axis, the swirler hub including a fuel manifold and an inner swirler with a multiple of inner vanes that support a centerbody, the multiple of inner vanes interconnect the fuel manifold and the centerbody.

Dai, Zhongtao↗